Professional Documents
Culture Documents
FINISH TOWERS
TONY HAGSTROM
04/20/2023
CONSULTANT:
CLIENT:
U.S. CELLULAR
8410 W. BRYN MAWR AVE.
SUITE 700
CHICAGO, IL 60631
BOWLING ST. SW
WILSON (293406)
SITE PLAN
SUBMITTAL:
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
PROJECT
NUMBER
31336
NOTES:
SET
TYPE
FINAL
1. AERIAL IMAGERY FROM GOOGLE EARTH.
2. NORTH ARROW SHOWN AS APPROXIMATE.
3. SITE PHOTOS PROVIDED BY EDGE CONSULTING ENGINEERS, INC.
SHEET
4. NO SURVEY AVAILABLE. SITE LAYOUT BASED ON FIELD
NUMBER C-101
MEASUREMENTS AND SITE PHOTOS.
CONSULTANT:
CLIENT:
U.S. CELLULAR
8410 W. BRYN MAWR AVE.
SUITE 700
CHICAGO, IL 60631
EXISTING FENCED
BRUSH COMPOUND
WILSON (293406)
SEE T-502 FOR DETAILS
EXISTING RACK-MOUNTED
ANCILLARY EQUIPMENT;
TO BE REMOVED
SEE A-101 FOR DETAILS
B
EXISTING MULTI-METER
UTILITY RACK
B COMPOUND OVERVIEW
EXISTING 4' WIDE MAN GATE EXISTING 4' WIDE MAN GATE
SUBMITTAL:
C
I:\31300\31336\Design\CAD\CD\Plot\C-102.dgn
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
PROJECT
NOTES: NUMBER
31336
C ICE BRIDGE
4. NO SURVEY AVAILABLE. SITE LAYOUT BASED ON FIELD
MEASUREMENTS, UAS-DRONE PHOTOGRAMMETRY, AND SITE PHOTOS.
SCALE: 11" x 17" - 1" = 5' NUMBER C-102
22" x 34" - 1" = 2.5'
CONSULTANT:
)
N.
TYPE "N" CONNECTOR FROM
MI
CABLE TO ANTENNA; NUT (TYP.)
6"CLEAR (
TWINE THE WATERPROOFING
AND ANTI-AGING ADHESIVE TAPE
U.S. CELLULAR
TO PROTECT THE JOINT 8410 W. BRYN MAWR AVE.
SUITE 700
CHICAGO, IL 60631
GROUND TERMINAL
TOOTH WASHER
GPS MOUNTING BRACKET;
SEE DETAIL BELOW
GPS CABLE
SITE DETAILS
WILSON (293406)
STANDOFF KIT
WHERE REQUIRED
SECURE GPS CABLE WITH 7/8"SNAP-IN
HANGER AND UNIVERSAL BARREL
CUSHION ALONG ENTIRE CABLE ROUTE
0.76"
MOUNTING PIPE
0.22"
2.68"
(2) ANTENNA MAST
1.72"
MOUNTING BRACKETS
3.1"
3.9"
LABEL
0.20" DIA. HOLE
(TYP. OF 4)
PLAN VIEW SIDE VIEW
0.59"
AND CABLE CLAMP END
2.8" DIA.
CLAMP BRACKETS
I:\31300\31336\Design\CAD\CD\Plot\C-501.dgn
CHECKED
(2) ANTENNA POST BY
MRM
2.05" MOUNTING BRACKETS
(4) M8 x 45 HEX BOLTS
(4) M8 FLAT WASHERS PLOT
2.76" DATE
6/9/2022
(4) M8 LOCK WASHERS
(4) M8 HEX NUTS
PROJECT
NUMBER
31336
BOTTOM VIEW FRONT VIEW ISOMETRIC VIEW
SET
TYPE
FINAL
GPS ANTENNA GPS MOUNTING BRACKET AUB MOUNTING HARDWARE KIT
D E F SHEET
NUMBER C-501
CONSULTANT:
MANUFACTURER:RAYCAP
MODEL: RUSDC-1176-PDU-48 (BREAKERS NOT INCLUDED)
RUSDC-1176-PDU-48-AMCB-1240 (12 x 40A BREAKERS INCLUDED)
DIMENSIONS:18.99" x 19.00" x 3.48" (D x W x H)
WEIGHT:22 LBS (WITHOUT BREAKERS)
624 WATER STREET
PRAIRIE DU SAC, WI 53578
OPTIONAL ACCESSORIES 608.644.1449 VOICE
12 BREAKER KIT FOR ERICSSON RADIO SET: AMCB-48-1225-KIT 608.644.1549 FAX
9 BREAKER KIT FOR NOKIA RADIO SET: AMCB-48-0640-0325-KIT www.edgeconsult.com
EXISTING POWER/FIBER JUNCTION BOX ; CONDUIT FROM 6120 RADIO CABINET TO JUNCTION
TO REMAIN BOX FOR POWER AND FIBER JUMPERS;
SEE A-501 FOR SIZE AND QUANTITY
PROPOSED GPS ANTENNA
FUTURE ERICSSON 6630 BASEBAND UNIT (BBU)
MOUNTED TO POST;
TO BE INSTALLED IN PROPOSED RADIO CABINET
TO REPLACE EXISTING RAYCAP POWER DISTRIBUTION UNIT (PDU)
BY ICI VENDOR
SEE C-501 FOR DETAIL
B
SUBMITTAL:
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
PROJECT
NUMBER
31336
SET
TYPE
FINAL
OUTDOOR EQUIPMENT LAYOUT
A SCALE: 11" x 17" - 3/8" = 1'-0" SHEET
22" x 34" - 3/4" = 1'-0" D EXISTING RACK-MOUNTED RADIO UNITS NUMBER A-101
CONSULTANT:
HYBRID CABLE TO HYBRID CABLE TO HYBRID CABLE TO
FIBER JUMPERS TO BE ROUTED IN 1-1/4" (1.66" O.D.) LIQUID-TIGHT
SECTOR RAYCAP SPD SECTOR RAYCAP SPD SECTOR RAYCAP SPD
FLEXIBLE METALLIC CONDUIT FROM JUNCTION BOX TO RAYCAP SPD;
(1) CONDUIT FOR EACH RAYCAP SPD
BASEBAND UNIT IN (2) 2" (2-3/8" O.D.) LIQUID-TIGHT SPD SPD SPD
1 RACK UNIT FLEXIBLE METALLIC CONDUIT TO
#1 #2 #3 CLIENT:
(IF REQUIRED) BASEBAND UNIT
(IF APPLICABLE) (IF APPLICABLE)
U.S. CELLULAR
8410 W. BRYN MAWR AVE.
SUITE 700
BASEBAND UNIT CHICAGO, IL 60631
1 RACK UNIT
POWER JUMPERS TO BE
GROUND KIT (TYP.);
ROUTED IN (2) 2" (2-3/8" O.D.)
SEE 5-501 FOR DETAILS
LIQUID-TIGHT FLEXIBLE
METALLIC CONDUIT TO
LTE EQUIPMENT CABINET
COLLECTOR 1" (1-1/4" O.D.) LIQUID-TIGHT FLEXIBLE
GROUND BAR METALLIC CONDUIT FROM LTE EQUIPMENT
BLOCK DIAGRAM
CABINET PLINTH FOR GPS CABLING
BATTERY BACKUP CABINET
K
AN
T BL
F
LE
LY
AL
ON
SUBMITTAL:
CE
PA
TJT 03/02/22 REV. B
ISS
TH BJN 06/09/22 REV. 0
I:\31300\31336\Design\CAD\CD\Plot\A-501.dgn
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
PROJECT
NUMBER
31336
SET
TYPE
FINAL
SHEET
NUMBER A-501
CONSULTANT:
CLIENT:
U.S. CELLULAR
8410 W. BRYN MAWR AVE.
SUITE 700
CHICAGO, IL 60631
ANTENNA SPECIFICATIONS
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
PROJECT
NUMBER
31336
SET
TYPE
FINAL
ANTENNA SPECIFICATIONS
A SHEET
NUMBER T-001
CONSULTANT:
MANUFACTURER: ERICSSON MANUFACTURER: ERICSSON MANUFACTURER:ERICSSON
MODEL: RADIO 4449 MODEL: RADIO 4480 44B2/B25 44B66A C MODEL:RADIO 4478
DIMENSIONS:17.9" x 13.2" x 9.4" (H x W x D) DIMENSIONS:21.8" x 15.7" x 5.8" (H x W x D) DIMENSIONS:18.1" x 13.5" x 7.8" (H x W x D)
WEIGHT:70.5 LBS WEIGHT:70.5 LBS WEIGHT:56.2 LBS
PLAN VIEW
PLAN VIEW
18.1"
EQUIPMENT SPECIFICATIONS
ERICSSON
ERICSSON RADIO 4449 ERICSSON RADIO 4480(MB) WITH FAN UNIT ERICSSON RADIO 4478
A B C
MANUFACTURER: RAYCAP
MODEL: RUSDC-6267-PF-48
DIMENSIONS:20.6" x 18.9" x 5.8" (H x W x D)
WEIGHT:19.95 LBS
MOUNTING BRACKET
INCLUDED; V-CLAMP FOR
REMOVE BRACKET AND USE MOUNTING TO POLE
E
ENCLOSURE MOUNTS FOR H-
L
FRAME OR WALL MOUNT BOTTOM VIEW
B
A
A
IC
IC
L
L
P
P
P
P
A
A
18.9" 5.8"
T
SUBMITTAL:
O
O
INT. DATE: DESCRIPTION:
N
N
IL
IL
BJN 01/27/22 REV. A
A
A
TJT 03/02/22 REV. B
T
T
E
E
D
D
BJN 06/09/22 REV. 0
IS
IS
H
H
18.9"
T
20.6"
I:\31300\31336\Design\CAD\CD\Plot\T-002.dgn
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
PROJECT
31336
FRONT VIEW SIDE VIEW NUMBER
SET
TYPE
FINAL
RAYCAP SURGE PROTECTOR DEVICE (SPD) CBRS NOT PRESENT mmWAVE NOT PRESENT
D E F SHEET
NUMBER T-002
CONSULTANT:
MANUFACTURER: RAYCAP MANUFACTURER:ERICSSON
MODEL: MOUNTING BRACKET MODEL:SXK 109 1973/2
WEIGHT:3.75 LBS
INCLUDED WITH RAYCAP SPD.
BRACKET FOR ATTACHING TWO STANDARD OR
HEAVY ERS UNITS WITH A HOLE PATTERN OF 624 WATER STREET
MOUNTING PIPE PRAIRIE DU SAC, WI 53578
CC 30 MM AND/OR CC 80 MM., EITHER TO A 608.644.1449 VOICE
POLE, WALL, ANGLE TOWER OR SQUARE TUBE. 608.644.1549 FAX
www.edgeconsult.com
U.S. CELLULAR
8410 W. BRYN MAWR AVE.
3.15" SUITE 700
CHICAGO, IL 60631
1.18"
4.33"
HOLES FOR
MOUNTING
HARDWARE
LOCK WASHER
BOLT
MOUNTING SPECIFICATIONS
5.12"
NUT
WILSON (293406)
WASHER
HOLES FOR
MOUNTING
HARDWARE ISOMETRIC VIEW
RAYCAP SURGE PROTECTOR DEVICE (SPD) MOUNT DUAL ERS BRACKET NR RADIO ON DUAL ERS BRACKET
A B C
K
AN
T BL
F
LE
LY
AL
ON
SUBMITTAL:
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
PROJECT
NUMBER
31336
SET
TYPE
FINAL
SHEET
NUMBER T-003
CONSULTANT:
12'-0"
12'-0"
(3) BIAS-T(S) TO BE REMOVED; SEE T-301 & T-501 FOR LAYOUT 8410 W. BRYN MAWR AVE.
ELEV: 64.0' ELEV: 64.0'
SUITE 700
CONCEALMENT CYLINDER C/L SEE T-301 FOR DETAILS CONCEALMENT CYLINDER C/L CHICAGO, IL 60631
12'-0"
CONCEALMENT CYLINDER;
ELEV: 52.0' ELEV: 52.0'
SEE T-301 FOR DETAILS
CONCEALMENT CYLINDER C/L CONCEALMENT CYLINDER C/L
SITE ELEVATION
ELEV: 9.5' EXISTING U.S. CELLULAR ELEV: 9.5' EXISTING U.S. CELLULAR
COAX PORT EQUIPMENT CABINETS ON COAX PORT EQUIPMENT CABINETS ON
EXISTING CONCRETE PAD EXISTING CONCRETE PAD
SUBMITTAL:
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
NOTE: NOTE:
1. ELEVATIONS ARE BASED ON MEASUREMENTS EXTRAPOLATED FROM 1. ELEVATIONS ARE BASED ON MEASUREMENTS EXTRAPOLATED FROM PROJECT
NUMBER
31336
UAS 3D POINT CLOUD. HEIGHTS ARE ROUNDED TO THE NEAREST 0.1' UAS 3D POINT CLOUD. HEIGHTS ARE ROUNDED TO THE NEAREST 0.1'
SET
TYPE
FINAL
EXISTING SITE ELEVATION PROPOSED SITE ELEVATION
A C SHEET
LTE
0°
CONCEALMENT CANISTERS & ARE DERIVED NOTE:
FROM PREVIOUS CONSTRUCTION DRAWINGS 624 WATER STREET
NORTH NORTH PROPOSED 61-5/8" 0.D. x 12' TALL FINAL MOUNTING CONFIGURATION
PRAIRIE DU SAC, WI 53578
CONCEALMENT CYLINDER TO BE DETERMINED BASED ON 608.644.1449 VOICE
CONCEALMENT CANISTER DESIGN; 608.644.1549 FAX
DESIGNED BY OTHERS;
www.edgeconsult.com
A1 TO BE PAINTED TO MATCH HARDWARE SHOWN IS PRELIMINARY
LTE
0°
EXISTING 30" 0.D. x 12' TALL EXISTING
CLIENT:
CONCEALMENT CYLINDER;
TO BE REMOVED & REPLACED
G1 B1 G1 B1
LT E LT
E E LT E
LT PROPOSED 61-5/8" 0.D. x 12' TALL
PCS/AWS/LTE
12
12 0° 0°
0° 0° 24
CONCEALMENT CYLINDER
24 DESIGNED BY OTHERS;
0°
TO BE PAINTED TO MATCH
EXISTING BIAS-T UNIT(S); EXISTING
TO BE REMOVED;
(TYP. OF 3)
ANTENNA CONFIGURATION
CONCEALMENT CYLINDER C/L @ 64' TO BE REMOVED & REPLACED
CONCEALMENT CYLINDER C/L @ 64'
WILSON (293406)
TRI-SECTOR MOUNT;
(CANSISTER) FOR DETAILS
EXISTING 4" SPLINE SUPPORT PIPE; SEE T-501 FOR DETAILS
TO BE REMOVED & REPLACED
VENTING REQUIREMENTS FROM HEAT
TRANSFER ANALYSIS REFERENCED
ON G-001 MUST BE FOLLOWED WHEN
ORDERING/ FABRICATION OF NEW
ANTENNA CONCEALMENT CYLINDERS
G2 B2 PC
E S/
LT
S/ AW
AW S/
S/ 12
LT
E
PC 0° 0°
24
CANISTER
UPPER
UPPER
SUBMITTAL:
CANISTER
TJT 03/02/22 REV. B
CANISTER
ION LOWER
VAT
LOWER
THI
AT
DING
LOA
NG
STI
EXI
NO
I:\31300\31336\Design\CAD\CD\Plot\T-301.dgn
CHECKED
BY
MRM
NOTES: PLOT
DATE
6/9/2022
ELEV: 70.0'
CLIENT:
K
U.S. CELLULAR
N
8410 W. BRYN MAWR AVE.
PROPOSED 6" (6.625" O.D.) SPLINE SUPPORT PIPE;
A
SUITE 700
L
G.C. TO REFERENCE STRUCTURAL DESIGN CHICAGO, IL 60631
B
REPORT - (CANISTER) FOR FINAL PIPE DIAMETER
T
PRIOR TO ORDERING COLLAR MOUNTS
F
E
L
C/L OF ANTENNA
Y
2-3/8" TO 3-1/2" O.D. MAST PIPES
L
ELEV: 65.0' ORDERED SEPARATELY;
L
12.0'
A
C/L OF CANISTER MAST PIPE LENGTH TO BE 12"
N
LONGER THAN ANTENNA LENGTH
IO
ELEV: 64.0'
T
N
E
EXISTING U.S. CELLULAR PANEL ANTENNA (TYP.)
T
TO BE SECURED TO NEW USTM ANTENNA MOUNT;
IN
E
C
A
PROPOSED RRU; SEE DETAIL
P
S
TO THE RIGHT FOR LAYOUT
IS
H
INSTALLATION DETAILS
RRU RRU C/L OF ANCILLARY EQUIPMENT
T
4449 4449
ELEV: 59.5'
WILSON (293406)
ELEV: 58.0'
ELEV: 54.5'
C/L OF CANISTER
ELEV: 52.0'
PROPOSED RRU; SEE DETAIL
TO THE RIGHT FOR LAYOUT
RRU RRU
RRU C/L OF ANCILLARY EQUIPMENT
4478 4478
4478 ELEV: 47.75'
80
R
ELEV: 46.0'
44
44 U
U
49
44
R
R
U
44
R
49
R
80
PROPOSED CANISTER VENTING BY OTHERS (TYP.)
R
SEE STRUCTURAL DESIGN REPORT - (CANISTER)
REFERENCED ON G-001 FOR DETAILS SUBMITTAL:
NOTE:
I:\31300\31336\Design\CAD\CD\Plot\T-501.dgn
1. ROUTE CABLES ALONG ROUND MEMBERS ON TOWER STANDOFFS OR TRAP BOXES AND SNAP-IN CHECKED
BY
MRM
HANGERS; SEE CABLE DETAILS SHEET. NOTE:
2. ROUTE POWER AND FIBER CABLES FROM RAYCAP SPD TO REMOTE RADIOS IN 1-1/4" INNERDUCT (TYP.)
PLOT
CONTRACTOR TO INSTALL INNERDUCT SO THAT THE ENDS TERMINATE EITHER HORIZONTALLY OR 1. THIS DETAIL IS A GENERAL SCHEMATIC, SEE T-301 FOR ACTUAL TOWER ORIENTATION AND EQUIPMENT QUANTITIES. 6/9/2022
DATE
DOWN TO PREVENT WATER INGRESS. 2. RAYCAP SPD AND REMOTE RADIOS AND MAY NOT BE INSTALLED ON TOWER LEGS THAT HAVE CLIMBER PEGS/SAFETY CLIMBS;
3. PER TIA STANDARDS: FALL PROTECTION ANCHORAGES SHALL BE AVAILABLE AT A MAXIMUM SPACING CONTRACTOR TO AVOID PEGS/SAFETY CLIMB AS NECESSARY. PROJECT
OF FOUR (4) FEET OVER THE HEIGHT NOT EQUIPPED WITH A SAFETY CLIMB SYSTEM OR OVER THE 31336
3. PER TIA STANDARDS: FALL PROTECTION ANCHORAGES SHALL BE AVAILABLE AT A MAXIMUM SPACING OF FOUR (4) FEET OVER THE NUMBER
LENGTH OF THE OBSTRUCTION TO THE CLIMBING FACILITY. HEIGHT NOT EQUIPPED WITH A SAFETY CLIMB SYSTEM OR OVER THE LENGTH OF THE OBSTRUCTION TO THE CLIMBING FACILITY.
SET
TYPE
FINAL
PROPOSED ANTENNA & EQUIPMENT MOUNTING RADIO EQUIPMENT LAYOUT PLAN
A C SHEET
NUMBER T-501
MANUFACTURER:EUPEN CONSULTANT:
MODEL:EUCAHYBRID 114-12AWG6
MINIMUM BENDING RADIUS:360mm (14")
MAXIMUM PULLING STRENGTH: 150 daN
MAXIMUM HANGER SPACING:1.0 m
APPROX. WEIGHT: 2300 kg/km (1.55 LB/FT) 624 WATER STREET
PRAIRIE DU SAC, WI 53578
1-1/4" HYBRID FIBER OPTIC CABLE WITH 48V ENERGY FEEDER IN 608.644.1449 VOICE
608.644.1549 FAX
CORRUGATED ALUMINUM SHIELDING WITH UV RESISTANT PE JACKET. www.edgeconsult.com
U.S. CELLULAR
8410 W. BRYN MAWR AVE.
SUITE 700
CHICAGO, IL 60631
CABLE DETAILS
MODEL: STK2-U
UNIVERSAL STANDOFF KIT, UNIVERSAL TOWER STANDOFF KIT
SITE PRO 1 PART # STK2-U FITS 1-1/2" DIA. TO 3" DIA. ROUND MEMBERS
OR APPROVED EQUIVALENT
MODEL: 78SS-A
7/8" STACKABLE SNAP-IN HANGER
MODEL: BCU78X
UNIVERSAL BARREL CUSHION
ACCEPTS 0.16" TO 0.55" O.D. CABLES
7/8" MATING HANGER
K
N
N
A
A
L
L
B
B
T
T
F
F
E
E
L
L
Y
Y
L
L
L
L
7/8" STACKABLE SNAP-IN HANGER,
A
SITE PRO 1 PART # 78SS-A OR
N
APPROVED EQUIVALENT SUBMITTAL:
IO
IO
INT. DATE: DESCRIPTION:
T
T
N
N
BJN 01/27/22 REV. A
E
E
T
T
TJT 03/02/22 REV. B
IN
IN
E
E
BJN 06/09/22 REV. 0
C
C
A
A
P
P
S
S
IS
IS
H
H
T
T
UNIVERSAL BARREL CUSHIONS,
I:\31300\31336\Design\CAD\CD\Plot\T-502.dgn
PROJECT
NUMBER
31336
SET
TYPE
FINAL
JUMPER ATTACHMENT
C SHEET
NUMBER T-502
CONSULTANT:
10"-12" 6"
"BAND OF SERVICE"
1" EMPTY (TYP.)
1" SEPARATION
BETWEEN BANDS (TYP.)
TYP. HYBRID COLOR CODE TYP. COAX JUMPER BANDING TYP. POWER & FIBER JUMPER BANDING
A B C
ALPHA RED (1) RED BAND (2) RED BANDS (3) RED BANDS (4) RED BANDS
BETA WHITE (1) WHITE BAND (2) WHITE BANDS (3) WHITE BANDS (4) WHITE BANDS
3/4" TO 1" SECTOR BANDS; GAMMA BLUE (1) BLUE BAND (2) BLUE BANDS (3) BLUE BANDS (4) BLUE BANDS
SEE TYP. BANDING CHART
DELTA LTE B2 LTE B4 & B66
GREEN (1) GREEN BAND (2) GREEN BANDS (3) GREEN BANDS (4) GREEN BANDS
(IF APPLICABLE) ALPHA BETA GAMMA ALPHA BETA GAMMA
EPSILON L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
VIOLET (1) VIOLET BAND (2) VIOLET BANDS (3) VIOLET BANDS (4) VIOLET BANDS
(IF APPLICABLE)
10"-12" EMPTY ZETA
BROWN (1) BROWN BAND (2) BROWN BANDS (3) BROWN BANDS (4) BROWN BANDS
(IF APPLICABLE)
SECTOR BAND (EXCEPTION CASE: ALPHA SECTOR CDMA ON 1 & 4, LTE ON 2 & 3)
ASSIGNED
SECTOR LINE 1 (CDMA) LINE 2 (LTE) LINE 3 (LTE) LINE 4 (CDMA)
COLOR
LTE B46 LTE B71
ALPHA RED (1) RED BAND (1) RED BAND (2) RED BANDS (2) RED BANDS
ALPHA BETA GAMMA ALPHA BETA GAMMA
SUBMITTAL:
L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
ASSIGNED 1900 B2 BLUE CHECKED
SECTOR LINE 1 LINE 2 MRM
COLOR BY
SET
TYPE
FINAL
TYP. RET CABLE BANDING TYP. BANDING CHART TYP. COAX COLOR CODE STANDARD
D E F SHEET
NUMBER T-503
CONSULTANT:
CLIENT:
U.S. CELLULAR
8410 W. BRYN MAWR AVE.
SUITE 700
CHICAGO, IL 60631
A A A
A A A B B
CABLE ROUTING
SUBMITTAL:
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
PROJECT
NUMBER
31336
SET
TYPE
FINAL
SHEET
NUMBER V-501
CONSULTANT:
Y1 R1 R2 Y2 Y1 R1 R2 Y2 Y1 R1 R2 Y2
1695-2400 617-894 617-894 1695-2400 1695-2400 617-894 617-894 1695-2400 1695-2400 617-894 617-894 1695-2400
U.S. CELLULAR
3 +45 -45 4 3 +45 -45 4 3 +45 -45 4
6 -45 2 4 -45 8 6 -45 2 4 -45 8 6 -45 2 4 -45 8 8410 W. BRYN MAWR AVE.
SUITE 700
Y1 R1 -45 -45 R2 Y2 Y1 R1 -45 -45 R2 Y2 Y1 R1 -45 -45 R2 Y2
1695-2400 617-894 617-894 1695-2400 1695-2400 617-894 617-894 1695-2400 1695-2400 617-894 617-894 1695-2400
CHICAGO, IL 60631
1 2 1 2 1 2
5 1 3 7 5 1 3 7 5 1 3 7
+45 -45 +45 -45 +45 -45
+45 +45 +45 +45 +45 +45 +45 +45 +45 +45 +45 +45
PLUMBING DIAGRAM
ERICSSON RRU4449 B12/B71 ERICSSON RRU4449 B12/B71 ERICSSON RRU4480 B2/B66 ERICSSON RRU4480 B2/B66 ERICSSON RRU4478 B5 ERICSSON RRU4478 B5
4.3-10 CONNECTORS 4.3-10 CONNECTORS 4.3-10 CONNECTORS 4.3-10 CONNECTORS 4.3-10 CONNECTORS 4.3-10 CONNECTORS
10 GB SFP 10 GB SFP 10 GB SFP 10 GB SFP 10 GB SFP 10 GB SFP
10 GB
10 GB
10 GB
10 GB 10 GB
10 GB
SUBMITTAL:
PLOT
FIBER JUMPER 6/9/2022
DATE
POWER JUMPER
PROJECT
31336
RET JUMPER NUMBER
GROUND BAR;
EQUIPMENT GROUND BAR FOR SEE TABLE BELOW
CONNECTION OF MULTIPLE
GROUND KITS AT ONE LEVEL
GROUNDING DETAILS
MOUNT TO TOWER STEEL; PART # CABLE SIZE & TYPE LENGTH LUG WEIGHT
PROPOSED HYBRID
(POWER/FIBER) OR SEE DETAIL TO THE RIGHT
GK-C12 1/2" CORRUGATED 5' UNATTACHED 1.50 LB.
POWER CABLE
WILSON (293406)
CABLE GROUND KIT
EQUIPMENT GROUND BAR 1/4" x 2" x 15" GROUND BAR WITH INSULATORS AND BRACKETS GK-C114 1-1/4" CORRUGATED 5' UNATTACHED 1.70 LB.
#6 AWG INSULATED STRANDED CU WIRE
ROUTE TO SIZED FOR 12 SETS OF 2-HOLE LUGS
CONNECTION TO GROUND BAR WITH 2 HOLE GK-C158 1-5/8" CORRUGATED 5' UNATTACHED 1.70 LB.
LOWER EQUIPMENT SITE PRO 1 PART #: MG21524 OR APPROVED EQUAL
LONG BARREL LUG
TIN PLATING SITE PRO 1 #: TIN21524 OR APPROVED EQUAL GK-C214 2-1/4" CORRUGATED 5' UNATTACHED 1.80 LB.
TYPICAL UPPER EQUIPMENT GROUNDING UPPER EQUIPMENT GROUND BAR CLIP ON GROUND KIT
A B C
ROUTE TO
UPPER RAYCAP SPD
PROPOSED HYBRID (
POWER/FIBER) OR
POWER CABLE
K
N
LA
B
FT
LE
Y
LL
RAYCAP SPD GROUND KIT
#6 AWG THHN GREEN A
N SUBMITTAL:
INSULATED STRANDED CU O
WIRE CONNECTION TO TI INT. DATE: DESCRIPTION:
N
TE
GROUND BAR WITH 2 HOLE BJN 01/27/22 REV. A
IS
TH
I:\31300\31336\Design\CAD\CD\Plot\E-501.dgn
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
SET
TYPE
FINAL
TYPICAL LOWER EQUIPMENT GROUNDING
D SHEET
NUMBER E-501
CONSULTANT:
CLIENT:
U.S. CELLULAR
8410 W. BRYN MAWR AVE.
SUITE 700
CHICAGO, IL 60631
A PROPOSED RAYCAP SPD(S) LOCATION B EXISTING JUNCTION BOX TO REMAIN C EXTERIOR SHELTER GROUND BAR
SUBMITTAL:
CHECKED
BY
MRM
PLOT
DATE
6/9/2022
PROJECT
NUMBER
31336
SET
TYPE
FINAL
SHEET
D ICE BRIDGE HANGER E TOWER GROUND BAR F DIPLEXERS TO BE REMOVED NUMBER R-901