Waterproofing Membrane for RC Roof – Bituminous Type
Properties/Tests Testing Method Criteria
1) Dry film thickness Dial micrometer 1 mm 2) Solid content SS 133 APP D Min. 50% 3) Water Penetration DIN 1048 Pt 5 Depth of penetration should be 0.7 kgf/cm2 for 6 hrs 0 4) Water Vapor Transmission ASTM E 96 5 to 30 g/m2/24hrs
5) Adhesion to substrate – after 7 ASTM D 4541 0.4 N/mm2
days cure ( N/mm2 ) 6) Tensile Strength ( N/mm2 ) ASTM D 412 a) 2.0 N/mm2 a) Before ageing b) 1.6 N/mm2 and b) After ageing at 500 C, 14days –ve change < 40 % ( change in tensile strength, % ) No limit for +ve change 7) Elongation at Break ASTM D 412 a) 300% ( Membrane without fiber / mesh ) b) 240% and a) Before ageing –ve change < 40 % b) After ageing at 500 C, 14days No limit for +ve change ( Change in elongation, % ) 8) Crack Bridging ASTM C 836 1) No cracking at 2mm width 2) No cracks after 10 cycles of stretching and closing to a width of 1mm 9) Hardness ( Shore A ) ASTM D 2240 30 – After 6 hrs cure 10) Set-to-touch ASTM D 1640 Should touch dry within 6 hrs 11) Heat Resistant SS 133 APP G No sagging, Slipping or Blistering 12) Water Resistant SS 133 APP I No Dispersion or Blistering 13) Fire Resistant SS 133 APP J No Combustion or Rundown 14) QUV Accelerated weathering ASTM G154 No cracking, chalking, blistering 1000hrs or peeling decay and de- lamination