You are on page 1of 10

FOR APPROVAL

QTY:01

PROJECT NAME:
Sl.No DATE APPROVED BY CONSULTANT COMMENTS

TELALA VALLEY

CONTRACTOR NAME:

BASTANA COMPANY

PANEL DESCRIPTION:

MDP - GARDEN 3

JOB NO:
4 --
3
DMT-023-0823-03
P.O BOX.4743, JEDDAH. 23449, SAUDI ARABIA PROJ/BOM --
2
1 03.09.23 REV.1 RH N.A K.H Tel :- +966-12-6630118/ 01-22880879/ 01-22880956
0 31.08.23 FIRST ISSUE RH N.A K.H
Fax :- +966-12-6630850
*** 000

REV DATE NATURE OF MODIFICATION Drawn By Designed By Checked By Approved By 001


1 2 3 4 5 6 7 8 9

D SHEET REV REV REV REV REV SHEET REV REV REV REV REV D
TITTLE PRE TITTLE PRE
No 1 2 3 4 5 No 1 2 3 4 5
001 FRONT PAGE X 030
001 LIST OF PAGE X 031
002 WIRING DIAGRAM SYMBOLS X 032
003 GENERAL CHARACTERISTICS X 033
004 POWER DIAGRAM X 034
005 POWER DIAGRAM X 035
006 CONTROL DIAGRAM X 036
007 ENCLOSURE X 037
008 ENCLOSURE X 038
009 LIST OF MATERIAL X 039
C C
010 040
011 041
012 042
013 043
014 044
015 045
016 046
017 047
018 048
019 049
020 050
B 021 051 B
022 052
023 053
024 054
025 055
026 056
027 057
028 058
029 059
030 060

A A
PROJECT : TITLE : JOB NO. SHEET:

2 03.09.23 REV.1 RH N.A TELALA VALLEY MDP - GARDEN 3 DMT-023-0823-03 001


--
0 31.08.23 FIRST ISSUE RH N.A CLIENT : NEXT:
SCALE : INDEX :
REV DATE NATURE OF MODIFICATION DRWN DSGN REV DATE NATURE OF MODIFICATION DRWN DSGN BASTANA COMPANY LIST OF PAGES
NTS 002
File Reference: Format: A4
1 2 3 4 5 6 7 8 9

T1 T2 T3

STEP1
STEP2
STEP3
T1

OFF
T1 T2 T3 ELECTRONIC TIMER T1
3-POLE 4-POSITION THERMAL OVERLOAD
CIRCUIT 3-POLE (ON DELAY) SELECTOR SWITCH NORMALLY OPEN
BREAKER CONTACTOR CONTACT
T4
RELAY
D T4 T5 T6 T4 D
T4 T5 T6

AUTO
T1 T2

MAN
T1 T2 T3 T2 T1
2-POLE THERMAL

O
T1
CIRCUIT OVERLOAD T3 ELECTRONIC TIMER 3-POSITION THERMAL OVERLOAD
T6
BREAKER RELAY (OFF DELAY) SELECTOR SWITCH NORMALLY CLOSE
T4 T5 T6 T4 T5 CONTACT
T4
TAGNAME
T4 T5

1 7 9

T1
AS AMMETER SWITCH
T1 2 4 M A T1
1-POLE TIME DELAY BLOCK
C CIRCUIT FUSE CARRIER 2-POSITION NORMALLY OPEN
C
BREAKER TAGNAME WITH 2A HRC FUSE SELECTOR SWITCH CONTACT
AM AMMETER
T4 T4

T4

1 5 9 11
T1 T2
T1 T2 T3 VS VOLTMETER SWITCH
T1
2 4 T1 T2
3-POLE TIME DELAY BLOCK
ISOLATOR TRANSFORMER CHANGEOVER NORMALLY CLOSE
SWITCH CONTACT CONTACT
T4 T5 T6 VM VOLTMETER T4
T4
T4 T5

B B
T1 T2 T3
A1 T1 T1 T1
2-POLE CONTACTOR RELAY CONTACTOR/CONTROL
ISOLATOR OR AUDIBLE RELAY NORMALLY OPEN
SWITCH CONTROL RELAY ALARM NORMALLY OPEN PUSH BUTTON
T4 T5 T6
A2
BZ
T4 T4 CONTACT T4

T1 T2 T3
A1
T1
T1
T1
3-POLE INDICATION CONTACTOR/CONTROL NORMALLY CLOSE
MOTOR A2 LAMP RELAY PUSH BUTTON
CIRCUIT T4 NORMALLY CLOSE T2
BREAKER TIME DELAY BLOCK CONTACT
T4
T4 T5 T6
A A
PROJECT : TITLE : JOB NO. SHEET:

2 03.09.23 REV.1 RH N.A TELALA VALLEY MDP - GARDEN 3 DMT-023-0823-03 002


--
0 31.08.23 FIRST ISSUE RH N.A CLIENT : NEXT:
SCALE : INDEX :
REV DATE NATURE OF MODIFICATION DRWN DSGN REV DATE NATURE OF MODIFICATION DRWN DSGN BASTANA COMPANY WIRING SYMBOLS
NTS 003
File Reference: Format: A4
1 2 3 4 5 6 7 8 9

GENERAL CHARACTERISTICS

SOURCE: APPARATUS DEGREE OF PROTECTION CIRCUIT MARKING

SOURCE : : 100A QTY. : __1___ MOUNTING : INCOMING OUTGOING PROTECTION : LABELS :


SYSTEM VOLAGE : 400/230V 3PH+N+E X FIXED X X IP 30 IP 42 IP 43 X IP 55 FORM 1 FORM 2 WITHOUT X GRAVOPLY
FREQUENCY : 60HZ DRAW-OUT ALUMINUM TRAFOLYTE
D FORM 2B FORM 3A FORM 3B FORM 4A FORM 4B
MECHANICAL SCREWED (EXTERNAL)
D
BREAKING CAPACITY (MAIN) : 36KA/400V/1SEC PLUG-IN
OPERATION : RIVETED SELF STICK
X NO PARALLEL OPERATION ENCLOSURES
______ X GLUED (INTERNAL)
PARALLEL OPERATION OF _____SOURCE MOTORIZED PRISMA P BLOKSET
ALL SOURCES PARALLEL X BEHIND DOOR X X WHITE LETTERS IN BLACK BACKGROUND
PRISMA G EATON xENERGY COLOR :
THROUGH PLATE
NEUTRAL SYSTEM : X DMT(SAUDI MADE) __________ LANGUAGE : ENGLISH
INTERLOCK
WEATHERPROOF
DIRECT TO EARTH (TT) EARTHED (TN) PADLOCKING
LEGRAND PACKING
ISOLATED (IT) X TNS SHUTTER
EGEPAN
THROUGH DOOR
DIRECT CURRENT : TO EARTH ISOLATED TERMINAL COVER X LAND TRANSPORT ______
PRESENTATION :
BUS BARS CONNECTIONS FIXED FRONT TRANSPARENT DOOR
FUNCTIONAL DOOR X WITH KEY APPROXIMATE WEIGHT :
INCOMING OUTGOING
MATERIAL : ALUM. X COPPER X PLAIN DOOR ______
X DIRECT X X X X
SYSTEM : CANOPY PLINTH
TO TERMINAL BLOCKS PARTICULAR NOTES :
X CONSTANT SECTION X H X V TO BUSBAR LUGS
C DECREASING H V APPARATUS DEFINED C
ACCESS :
X TIN PLATED X H X V PARTIC DIMENSIONS
X FRONT X X COLOR PAINTING : EXTENSION OF
REAR RAL6012 (Green) X RAL7035 SIMILAR TO
LEFT SIDE/RIGHT SIDE RAL7053 (Dark Gray) RAL7032 (Light Gray)
NEUTRAL OR PEN : PE :
SPECIAL REQUIREMENT RAL9001
NOT DISTRIBUTED HORIZONTAL ENTRY :
SPECIFICATION/ IEC 61439-1&2
X SAME SECTION AS PHASES X VERTICAL TOP
DEVIATION
HALF SECTION X HALF OF NEUTRAL X BOTTOM (BY CABLES) X X
PUSH BUTTONS/LAMPS
LOOSE MATERIAL
SUPPLY OF AUXILIARIES

VOLTAGE : ORIGIN : LAMPS : R Y B


-- SHROUDING : X RED X YELLOW X BLUE
- ALL CIRCUITS _______VAC, 60HZ EXTERNAL DRAWINGS :
- CONTROL _____VAC, 60HZ X FROM BUS. BAR X CABLE ENDS X X
FOR INFORMATION X FOR APPROVAL
230
-SIGNALLING _____VAC, 60HZ AUXILIARY TRANSFO.
B AUXILIARY WIRING FOR PRODUCTION AS-BUILT B
INDICATING INSTRUMENT (METERS)

CLIMATIC CONDITION SEC. VOLTAGE : X 1.5 X 1.5 CONTROL


____ INSTRUMENTS :
X 2.5 01
CURRENT : ____ SQ.MM. X SIZE 96 x 96 SIZE 72 x 72 QTY. :__________
TYPE OF CLIMATE : X NORMAL ______ COLOR : X BLACK RED SIZE 15 x 10 SIZE 48 x 48
TYPE OF ATMOSPHERE : X ORDINARY TO SUIT DESERT OTHERS: REMARKS
CONDITIONS MARKING OF CIRCUITS
POLLUTION RISKS : POWER : BLACK X L1, L2, L3
-MOUNTING : INDOOR X OUTDOOR METER RELAY :
AUXILIARY : LOCAL END
-AMBIENT TEMPERATURE: 50°C 50°C
X ______ X BOTH ENDS
COMPOSED
________

A A
PROJECT : TITLE : JOB NO. SHEET:

2 03.09.23 REV.1 RH N.A TELALA VALLEY MDP - GARDEN 3 DMT-023-0823-03 003


--
0 31.08.23 FIRST ISSUE RH N.A CLIENT : NEXT:
SCALE : INDEX :
REV DATE NATURE OF MODIFICATION DRWN DSGN REV DATE NATURE OF MODIFICATION DRWN DSGN BASTANA COMPANY GENERAL CHARACTERISTICS
NTS 004
File Reference: Format: A4
1 2 3 4 5 6 7 8 9

TO SHT.005
BUSBAR : COPPER BUSBAR. 100A., 3PH+N+E, 400/230V, 60Hz.
L1
L2
L3

D N D

S1
10
3X I1
S2
11
CT's
100/5A 12
S1
I2 1 3 5 5 1 3 5 1 3 5 1 1
S2
13

S1
14
I3 QSP Q1 Q2 Q3 Q4
S2
15 MCB,4P MCB,3P MCB,3P MCB,1P MCB,1P
IC60N C 2 4 6 6 IC60N C 2 4 6 IC60N C 2 4 6 IC60N C 2 IC60N C 2
1 3 5 40A 32A 32A 32A 32A
DM

Q0
MCCB,3P
C NSX100F+TM100D 2 4 6
C
100AT/100AF
FXD FU1~FU3
V1

V2
D0
V3 23/-
D1
N 22/+

R Y B

T1 VIGIREX
TOROID RH99
B CT
T2 B
A1 A2

SPD
E

L1 L2 L3 N E

FEEDER MAIN INCOMING PUMP WATER SUB PUMP WATER SPARE SPARE

SYSTEM VOLTAGE 400V/3Ph/60HZ 400V/3Ph/60HZ 400V/3Ph/60HZ 230V/1Ph/60HZ 230V/1Ph/60HZ


AMPERE RATING: 100A 32A 32A 32A 32A
A CABLE SIZE -- 4x16mm² -- -- -- A
PROJECT : TITLE : JOB NO. SHEET:

2 03.09.23 REV.1 RH N.A TELALA VALLEY MDP - GARDEN 3 DMT-023-0823-03 004


--
0 31.08.23 FIRST ISSUE RH N.A CLIENT : NEXT:
SCALE : INDEX :
REV DATE NATURE OF MODIFICATION DRWN DSGN REV DATE NATURE OF MODIFICATION DRWN DSGN BASTANA COMPANY POWER DIAGRAM
NTS 005
File Reference: Format: A4
1 2 3 4 5 6 7 8 9

FROM SHT.004
L1
L2
L3

D N D

1 3 5

Q01
1 MCB,3P
IC60N C 2 4 6
63A
Q10
MCB,1P
1 2 3
IC60N C 2
32A
KM1
LC1D80AM7 4 5 6
80A,3P

C C

1 3 5 1 3 5 1 3 5 1 3 5

Q5 Q6 Q7 Q8
MCB,3P MCB,3P MCB,3P MCB,3P
IC60N C 2 4 6 IC60N C 2 4 6 IC60N C 2 4 6 IC60N C 2 4 6
32A 32A 32A 32A

B B

SPARE LIGHTING LOOP # 1 LIGHTING LOOP # 2 LIGHTING LOOP # 3 SPARE

230V/1Ph/60HZ 400V/3Ph/60HZ 400V/3Ph/60HZ 400V/3Ph/60HZ 400V/3Ph/60HZ


32A 32A 32A 32A 32A
A -- 4x10mm² 4x6mm² 4x6mm² -- A
PROJECT : TITLE : JOB NO. SHEET:

2 03.09.23 REV.1 RH N.A TELALA VALLEY MDP - GARDEN 3 DMT-023-0823-03 005


--
0 31.08.23 FIRST ISSUE RH N.A CLIENT : NEXT:
SCALE : INDEX :
REV DATE NATURE OF MODIFICATION DRWN DSGN REV DATE NATURE OF MODIFICATION DRWN DSGN BASTANA COMPANY POWER DIAGRAM
NTS 006
File Reference: Format: A4
1 2 3 4 5 6 7 8 9

D 1 FU4 2 D
L1

A 0 M
A M

SS

1
TAPPED AFTER "Q0" 4 3
C 230V AC C
PHOTOCELL

2 3

7
2
TM
3
8

A1
B B
KM1
A2
0
N

A A
PROJECT : TITLE : JOB NO. SHEET:

2 03.09.23 REV.1 RH N.A TELALA VALLEY MDP - GARDEN 3 DMT-023-0823-03 006


--
0 31.08.23 FIRST ISSUE RH N.A CLIENT : NEXT:
SCALE : INDEX :
REV DATE NATURE OF MODIFICATION DRWN DSGN REV DATE NATURE OF MODIFICATION DRWN DSGN BASTANA COMPANY CONTROL DIAGRAM
NTS 007
File Reference: Format: A4
1 2 3 4 5 6 7 8 9

PHOTOCELL
LIFTING
RINGS CANOPY

D 400mm 1200mm D
400mm

C C
1400mm

B B

SIDE VIEW DOOR VIEW SIDE VIEW

A A
PROJECT : TITLE : JOB NO. SHEET:

2 03.09.23 REV.1 RH N.A TELALA VALLEY MDP - GARDEN 3 DMT-023-0823-03 007


--
0 31.08.23 FIRST ISSUE RH N.A CLIENT : NEXT:
SCALE : INDEX :
REV DATE NATURE OF MODIFICATION DRWN DSGN REV DATE NATURE OF MODIFICATION DRWN DSGN BASTANA COMPANY ENCLOSURE
NTS 008
File Reference: Format: A4
1 2 3 4 5 6 7 8 9

CANOPY

D 1200mm 1200mm D

QSP SPD PC,TM,FU1~4

FU FU FU FU

DM

R Y B
L1 L2 L3

S.S
M O A

C C

KM1
1400mm

80A,3P

Q0 Q01
80A 63A
COMB-BUSBAR COMB-B.BAR
L3 L3

Q6~Q9 Q1~Q5
L2 L2
L1 L1

MAIN INCOMING

32A

32A

32A

32A

32A

32A
32A
32A
32A
N E

B B

OUTGOING

INSIDE VIEW INTERNAL DOOR VIEW

A A
PROJECT : TITLE : JOB NO. SHEET:

2 03.09.23 REV.1 RH N.A TELALA VALLEY MDP - GARDEN 3 DMT-023-0823-03 008


--
0 31.08.23 FIRST ISSUE RH N.A CLIENT : NEXT:
SCALE : INDEX :
REV DATE NATURE OF MODIFICATION DRWN DSGN REV DATE NATURE OF MODIFICATION DRWN DSGN BASTANA COMPANY ENCLOSURE
NTS 009
File Reference: Format: A4
1 2 3 4 5 6 7 8 9

ITEM # REFERENCE DESCRIPTION QTY BRAND


3 MDP - GARDEN 3 1
Enclosure Brand DMT(Saudi Made) Short Circuit 10KA
Ratings
Panel Type Non Type Tested Assembly Enclosure Finish RAL-7035
D Enclosure Mounting Floor Standing-Box Type Busbar Plating D
Type
Type of Forms Form-2 Phase Busbar Size 100%
Degrees of Protection IP-55 Neutral Busbar Size 100%
Enclosure Thickness 2mm Ground Busbar 50%
Size
Incoming Cable Entry Bottom Outgoing Cable Bottom
Entry
SIZE {1400(H)x1200(W)x400(D)}

BUSBAR
Main: COPPER BAR Rated 100A, 3 Phase + N Lot ORIENTAL

Neutral: Equal phase Lot ORIENTAL

Ground: Half Neutral Lot ORIENTAL

MAIN-INCOMING

C LV429630 circuit breaker Compact NSX100F - TMD - 1 Schneider


C
56173 EARTHLEAKAGE RELAY RH99M WITH MANUAL RES 1 Schneider

LV429407 MN 220-240V50/60HZ 208-277V60HZ UVR 1 Schneider

50437 CLOSED TOROID TA30 65A DIA. 30MM 1 Schneider

LIGHTING
LC1D80M7 TeSys D contactor 3P AC3 80A 220V AC coi 1 Schneider

XA2ED33 SS,3 POSITION,2NO(SHORT) 1 Schneider

ZA2EE101 CONTACTBLOCK,1NO 1 Schneider

TIMER 1 Non-Schnedier

PHOTOCELL 1 Non-Schnedier

METTERING
SACI.TU20/0100 CURRENT TRANSF 100/5A 3 Non-Schnedier

DM multimeter Volt ammper frequency 1 Non-Schnedier

XA2EVM4LC Pilot Light 1 Schneider


B XA2EVM5LC Pilot Light 1 Schneider
B
XA2EVM6LC Medium XA2 Pilot Light,220v AC, Blue 1 Schneider

SFLG06 FUSE Gg 6A 4 Non-Schnedier

SFH132 FUSE HOLDER 10X38 1P 4 Non-Schnedier

SURGE ARRISTOR:
A9F44440 ACTI9 IC60N 4P 40A C MCB 1 Schneider

A9L65601 iPRD65r 3P+N 1 Schneider

SUB MAIN
A9F44363 ACTI9 IC60N 3P 63A C MCB 1 Schneider

BRANCHES OUTGOING 1
A9F44332 ACTI9 IC60N 3P 32A C MCB 4 Schneider

BRANCHES OUTGOING 2
A9F44332 ACTI9 IC60N 3P 32A C MCB 2 Schneider

A A9F44132 ACTI9 IC60N 1P 32A C MCB 3 Schneider


A
PROJECT : TITLE : JOB NO. SHEET:

2 03.09.23 REV.1 RH N.A TELALA VALLEY MDP - GARDEN 3 DMT-023-0823-03 009


--
0 31.08.23 FIRST ISSUE RH N.A CLIENT : NEXT:
SCALE : INDEX :
REV DATE NATURE OF MODIFICATION DRWN DSGN REV DATE NATURE OF MODIFICATION DRWN DSGN BASTANA COMPANY LIST OF MATERIAL
NTS END
File Reference: Format: A4

You might also like