Series 46
Individual mounting Series
Inline
33
Manifold mounting 34
Manifold base
Manifold base Manifold base
Stacking
Manifold base “plug-in” with
“plug-in” pressure
“plug-in” with “plug-in” 36
flow controls with PR & FC
regulators
32
37
38
52
Oval shaped armature 67
69
Encapsulated coil 44
46
Push pin
42
A
Exh.
47
48P
Bonded balanced poppet
In B 48
Return spring
400
92
SERIES FEATURES
93
• Patented high force MACSOLENOID® for fastest possible response times. ISO 01
• Bonded balanced poppet for high flow, precise repeatability, and consistent operation.
• Balanced poppet permits versatility in function — may be used as 3-way or 2-way normally open or
ISO 02
normally closed and may be used for vacuum, divertor, or selector applications. ISO 1
• Extremely high cycle rate capability. ISO 2
• Use on lube or non-lube service.
• Manual overrides as standard.
ISO 3
• Various solenoid enclosures and plug-in connectors.
• Optional surge suppression available.
• Low wattage DC solenoids — down to 1.3 watts.
• Rectified AC voltage.
79 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Direct solenoid and solenoid pilot operated valves
Series 46
Function Port size Flow (Max) Individual mounting Series
4/2 1/8” - # 10-32 0.3 Cv Inline
OPERATIONAL BENEFITS
33
1. Balanced poppet, immune to variations of
pressure.
34
2. Patented solenoid develops high shifting
forces. 36
3. Short stroke with high flow.
4. Higher forces result in lower wattages for
given flow.
5. Powerful return spring.
32
37
38
52
HOW TO ORDER
67
Single Operator Double Operator 69
Port size Without flow controls With flow controls Without flow controls With flow controls
44
A B A B A B A B
A B A B A B A B
46
EXH IN EXH IN EXH IN EXH IN
1/8” NPTF 46A-AA1-J XXX-XXX 46A-AA2-J XXX-XXX 46A-GA1-J XXX-XXX 46A-GA2-J XXX-XXX 42
# 10-32 46A-AB1-J XXX-XXX 46A-AB2-J XXX-XXX 46A-GB1-J XXX-XXX 46A-GB2-J XXX-XXX
47
SOLENOID OPERATOR ® J XXX-XXX (-G) Add “G” for ground
* 48P
81 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
100%
OF
PRODUCTION
TESTED
18MONTHS
Series 46
TECHNICAL DATA
26.5
w/FLOW
CONTROLS
22.5 43.3
w/o FLOW
CONTROLS
25.8
7.5
43.3
3.8
32.7
8.5
8.0
70.9
EX
EX
11.0 10.9
18.8
38.0
15.7 15.7
15.2 15.2
IN
109.4 Ø 3.4
TYP. (2) 8.0
8.0
7.5 3.2 DIA.
3.8 25.8
22.5
1/8" PORTS 32.5
26.5
82 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Direct solenoid and solenoid pilot operated valves
Series 46
Function Port size Flow (Max) Manifold Mounting Series
4/2 1/8” - # 10-32 0.3 Cv Stacking
OPERATIONAL BENEFITS
33
1. Balanced poppet, immune to variations of
pressure.
34
2. Patented solenoid develops high shifting
forces. 36
3. Short stroke with high flow.
4. Higher forces result in lower wattages for
given flow.
5. Powerful return spring.
32
37
38
52
HOW TO ORDER
67
Port size Without flow controls With flow controls 69
A
A B
B A
A B
B
44
EXH IN EXH IN
46
1/8” NPTF 46A-SA1-J XXX-XXX 46A-SA2-J XXX-XXX
# 10-32 46A-SB1-J XXX-XXX 46A-SB2-J XXX-XXX
42
SOLENOID OPERATOR ® J XXX-XXX * (-G) Add “G” for ground 47
48P
XX Voltage X Wire length X Manual operator XX Electrical connection
AA 120 VAC (5.4W) A 18” 1 Non-locking recessed BA Flying leads
DA 24 VDC (5.4W) B 24” 2 Locking recessed GA MAC JAC solenoid plug-in 48
DB 12 VDC (5.4W) C 36” GB MAC JAC solenoid plug-in
DC 24 VDC (2.4W) with diode
DD 12 VDC (2.4W) GG MAC JAC solenoid plug-in
with rectifier 400
* Other options available, see page 317.
Note : - AC voltage requires connector with rectifier.
92
- With the MAC JAC, washdown capability is possible. Consult factory for washdown modification number.
83 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
OF
PRODUCTION
TESTED
100%
18 MONTHS
Series 46
TECHNICAL DATA
Spare parts : • Inlet isolator : 28494 • Exhaust isolator : 28493 • Tie rod (x2) : 79411
33.6
TYP.
Ø 5.3
TYP.
Ø 5.3
TYP.
21.1
4.9 152.0
TYP. -
71.5
27.4
19.8
12.7 10.5
7.0
44.1 TYP. 16.5 10.1
15.0 TYP. 1/8" CYLINDER 32.6
PORTS
162.0 1/4" INLET AND
EXHAUST COMMONS
84 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Direct solenoid and solenoid pilot operated valves
Series 46
Function Port size Flow (Max) Manifold mounting Series
4/2 1/8" - 5/32 O.D. Pressed-in 0.3 Cv Manifold base
tube receptacles “plug-in”
OPERATIONAL BENEFITS
33
1. Balanced poppet, immune to variations of
pressure.
34
2. Patented solenoid develops high shifting
forces. 36
3. Short stroke with high flow.
4. Higher forces result in lower wattages for
given flow.
5. Powerful return spring.
32
37
38
52
HOW TO ORDER
67
Port size Single solenoid Double solenoid 69
A
A B
B A
A B
B
44
EXH IN EXH IN 46
Valve less base 46A-L00-00-J XXP-XXX 46A-N00-00-J XXP-XXX
1/8” NPTF 46A-LSA-AC-J XXP-XXX 46A-NSA-BL-J XXP-XXX
5/32 O.D. Pressed-in tube receptacles 46A-LSF-AC-J XXP-XXX 46A-NSF-BL-J XXP-XXX 42
47
SOLENOID OPERATOR ® J XX P-XXX * (-G) Add “G” for ground 48P
85 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
100%
OF
PRODUCTION
TESTED
18 MONTHS
Series 46
TECHNICAL DATA
Spare parts : • Inlet isolator : 28501 • Exhaust isolator : 28502 • Valve cover plate : M-46002
• Tie rod (x2) : 79443
95.5
78.0 95.5
15.0
15.0
62.9
62.9
32.8
22.5
9.5
32.8
Ø 4.3
94.3 Ø 4.3 22.5
4.4 9.5 4.4
TYP. 1/4" COMMONS TYP.
19.0
4.0 19.0
4.0
34.2
34.2
52.5
52.5
79.0
79.0
95.5
95.5
3/4"-14 NPSM
78.0
86 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Direct solenoid and solenoid pilot operated valves
Series 46
Function Port size Flow (Max) Manifold mounting Series
Manifold base
4/2 1/8" - 5/32 O.D. Pressed-in 0.3 Cv “plug-in” with
tube receptacles pressure
regulators
OPERATIONAL BENEFITS
33
1. Balanced poppet, immune to variations of
pressure.
34
2. Patented solenoid develops high shifting
forces. 36
3. Short stroke with high flow.
4. Higher forces result in lower wattages for
given flow.
5. Powerful return spring.
32
37
38
52
HOW TO ORDER
67
Port size Model number 69
(Bottom ports only)
A
A B
B
44
EXH IN
46
Valve less base 46A-L00-00-J XXP-XXX
1/8” NPTF 46A-LSA-AJ-J XXP-XXX
5/32 O.D. Pressed-in tube receptacles 46A-LSF-AJ-J XXP-XXX 42
SOLENOID OPERATOR ® J XX P-XXX * (-G) Add “G” for ground 47
48P
XX Voltage X Manual operator XX Electrical connection
AA
DA
120 VAC (5.4W)
24 VDC (5.4W)
1
2
Non-locking recessed
Locking recessed
FA
FB
Base plug-in
Base plug-in with diode
48
DB 12 VDC (5.4W) FG Base plug-in with rectifier
DC 24 VDC (2.4W)
400
* Other options available, see page 317.
Note : AC voltage requires connector with rectifier.
OPTIONS
92
46A-LSA-AJ-JXXP-XXX
J Regulator with adjusting knob
93
E Regulator with slotted stem
G Regulator with slotted stem with locknut
0 Base only – no valve
ISO 01
L Base mount body
M Base mount body with gage port
ISO 02
Example : base only with regulator : 46A-0SA-AJ. ISO 1
End plate kit required (port size 1/4") : M-46003-01.
ISO 2
ISO 3
87 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
OF
PRODUCTION
TESTED
100%
18
MONTHS
Series 46
TECHNICAL DATA
78.0
32.8
22.5
94.3 9.5
4.4 TYP.
1/8" GAGE
PORT
69.2
104.1
Ø 4.3
35.5
1/4" COMMONS 8.5
19.0
4.0
34.2
52.5
79.0
95.5
95.5 15.0
62.9
3/4"-14 NPSM
88 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Direct solenoid and solenoid pilot operated valves
Series 46
Function Port size Flow (Max) Manifold mounting Series
4/2 1/8" - 5/32 O.D. Pressed-in 0.3 Cv Manifold base
“plug-in” with
tube receptacles flow controls
OPERATIONAL BENEFITS
33
1. Balanced poppet, immune to variations of
pressure.
34
2. Patented solenoid develops high shifting
forces. 36
3. Short stroke with high flow.
4. Higher forces result in lower wattages for
given flow.
5. Powerful return spring.
32
37
38
52
HOW TO ORDER
67
Port size Model number 69
A
A B
B
44
EXH IN 46
Valve less base 46A-L00-00-J XXP-XXX
1/8” NPTF 46A-LSA-AD-J XXP-XXX
5/32 O.D. Pressed-in tube receptacles 46A-LSF-AD-J XXP-XXX 42
SOLENOID OPERATOR ® J XX P-XXX * (-G) Add “G” for ground 47
48P
XX Voltage X Manual operator XX Electrical connection
AA 120 VAC (5.4W) 1 Non-locking recessed FA Base plug-in
DA 24 VDC (5.4W) 2 Locking recessed FB Base plug-in with diode 48
DB 12 VDC (5.4W) FG Base plug-in with rectifier
DC 24 VDC (2.4W)
OPTIONS
92
46A-LSA-AD-JXXP-XXX
D Side cylinder ports 93
M Bottom cylinder ports
89 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
OF
PRODUCTION
TESTED
100%
18 MONTHS
Series 46
TECHNICAL DATA
Spare parts : • Inlet isolator : 28501 • Exhaust isolator : 28502 • Valve cover plate : M-46002
• Tie rod (x2) : 79443
8.0
24.0
78.0
Ø 4.3 32.8
94.3 22.5
1/4" COMMONS 104.1
4.4 TYP. 9.5
35.5
8.5
19.0
4.0
34.2
52.5
79.0
95.5 95.5
15.0
62.9
3/4"-14 NPSM
90 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Direct solenoid and solenoid pilot operated valves
Series 46
Function Port size Flow (Max) Manifold mounting Series
4/2 1/8" - 5/32 O.D. Pressed-in 0.3 Cv Manifold base
“plug-in”
tube receptacles with PR & FC
OPERATIONAL BENEFITS
33
1. Balanced poppet, immune to variations of
pressure.
34
2. Patented solenoid develops high shifting
forces. 36
3. Short stroke with high flow.
4. Higher forces result in lower wattages for
given flow.
5. Powerful return spring.
32
37
38
52
HOW TO ORDER
67
Port size Model number 69
(Bottom ports only)
A
A B
B
44
EXH IN 46
Valve less base 46A-L00-00-J XXP-XXX
1/8” NPTF 46A-LSA-AK-J XXP-XXX
5/32 O.D. Pressed-in tube receptacles 46A-LSF-AK-J XXP-XXX 42
SOLENOID OPERATOR ® J XX P-XXX * (-G) Add “G” for ground 47
48P
XX Voltage X Manual operator XX Electrical connection
120 VAC (5.4W) Non-locking recessed Base plug-in
AA
DA 24 VDC (5.4W)
1
2 Locking recessed
FA
FB Base plug-in with diode
48
DB 12 VDC (5.4W) FG Base plug-in with rectifier
DC 24 VDC (2.4W)
OPTIONS
92
46A-LSA-AK-JXXP-XXX
K Regulator with adjusting knob & flow controls 93
F Regulator with slotted stem & flow controls
H Regulator with slotted stem with locknut & flow controls
0 Base only – no valve
ISO 01
L Base mount body
M Base mount body with gage port ISO 02
Example : base only with regulator : 46A-0SA-AK. ISO 1
End plate kit required (port size 1/4") : M-46003-01.
ISO 2
ISO 3
91 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
100% WARRANTY
OF
PRODUCTION
TESTED
100%
18 MONTHS
Series 46
TECHNICAL DATA
78.0
32.8
22.5
94.3
9.5
4.4 TYP.
1/8" GAGE
PORT
69.2
104.1
Ø 4.3
35.5
1/4" COMMONS 8.5
19.0
4.0
34.2
52.5
79.0
95.5
95.5 15.0
62.9
3/4"-14 NPSM
92 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
OPTIONS
317 Consult “Precautions” page 327 before use, installation or service of MAC Valves..
OPTIONS
J-XX X-X XX
1. VOLTAGE *JL Square Connector with Rectifier with light
*JJ Square Connector Male only (Plain)
J-XX X-X XX VOLTAGE *JB Rectangular Connector
AA 120VAC (5.4W) *JD Rectangular Connector with light
AC 24VAC (5.4W) *JN Rectangular Connector with diode
DE 24VDC (1.8W) *JP Rectangular Connector with MOV
DF 12VDC (1.8W) *JR Rectangular Connector with diode/light
DJ 24VDC (1.3W) *JS Rectangular Connector with MOV /light
DL 12VDC (1.3W) *JT Rectangular Connector with Rectifier
DR 12VDC (1.0W)* *JU Rectangular Connector with Rectifier with light
DU 24VDC (1.0W)* *JM Rectangular Connector Male only (Plain)
* Not available on 36 series universal valve * Not available on manifold or stacking valves
318 Consult “Precautions” page 327 before use, installation or service of MAC Va