Plug-in Relays: Technical data

Technical data 1 CO 2 CO 3 CO 4 CO

Type 7RQ0 100-0A… 7RQ0 100-0B… 7RQ0 110-0B… 7RQ0 100-0C… 7RQ0 100-0D…

Width mm 12.5 12.5 21 35 21

Depth mm 36 36 38.5 50.8 38.5

Dimensions Height mm 31 31 28 35 28

Weight gms 21 21 43 80 43

Orientation any

Rated Insulation Voltage [Ui] Ui (V) 250


(pollution degree 3) AC

Rated control supply voltage Uc (V) AC : 6V, 12V, 24V, 48V, 110V, 115, 230V
[Uc] DC : 6V, 12V, 24V, 48V, 110V

Overvoltage category II

Impulse withstand voltage Ue 2.5


[Uimp] (kV)

Rated Frequency AC Hz 50/60

Control voltage tolerance ≥ 0.8 x Uc------- ≤ 1.1 x Uc

Power consumption for coil AC, VA 1.1 1.1 1.2 1.6 1.2

DC, W 0.7 0.7 1 1.3 1


General
Dielectric Strength
kV 3
- Between Contacts and Coil

IP protection Relay IP 40

base IP 20

Type of insulation Double Basic Double Basic

Mounting distance (side by mm 1.5 2.5 2.5 4.0 4.0


side)

Categories of environmental RT1


protection (RT)

Temperature Operation DC -40°C to 70°C

AC -40°C to 55°C

Operate time + bounce time ms 10.00 10.00 16.00 17 10.00


Time
Release time + bounce time ms 8.00 8.00 8.00 28 6.00

Mechanical OPS. For DC coil : For DC coil : For DC coil : For DC coil : For DC coil :
20 millions 20 millions 20 millions 20 millions 20 millions
For AC coil : For AC coil : For AC coil : For AC coil : For AC coil :
10 millions 10 millions 10 millions 10 millions 10 millions
Life
Electricals OPS. 0.1 Millions

Operating Freq at nominal load Op / hr 360