You are on page 1of 15

FA280

AI+ FECES ANALYZER


NEW GENERATION FULLY AUTOMATIC DIGITAL FECES ANALYZER

待机 运行 停止

待机 运行 停止

FA280

Accurate Faster Powerful

Add: No.6, Xixin Avenue, Hi-Tech Zone, Chengdu, China 611731


Tel: 0086-28-62533858
Fax: 0086-28-87820370
Website: www.orienterglobal.com Follow us PN:20210204 Service: 400-823-6886
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT
满足您的需求 我们一直在努力

ENTERPRISE COMPANY
CULTURE PROFILE

Mission:

Innovation Leads to Development


Science & Technology Serve Human Health

Vision:

Be a Respected World-class IVD Enterprise

Core Values:

Struggle & Innovation


Lean Management
Sharing Glory

Founded in 2011, Sichuan Orienter Biotechnology Co., Ltd is As a pioneer, Orienter Fully Automatic Digital Feces
headquartered in Hi-Tech (West) Zone of Chengdu, China. Analyzer promotes the feces analysis into a new era of
Orienter is dedicated to the R&D, manufacturing, marketing, automation and intelligence.
sales and after sales-service of high quality diagnostic
products including feces detection, clinical biochemistry, Firmly committed to our mission of “Innovation Leads to
luminescence immunization etc. The perfect professional Development, Science & Technology Serve Human Health”,
service for product dealers and end customers would be and guided by enterprise core values, Orienter is dedicated
provide by Orienter. Orienter is certified with ISO9001, to innovation in the fields of In-Vitro Diagnostics and strives
ISO13485 and CE. to be the respected world-class IVD enterprise.
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT
满足您的需求 我们一直在努力

CONTENTS

01 02
02
FA280 FULLY AUTOMATIC
FA280 FULLY AUTOMATIC DIGITAL FECES ANALYZER
COMPANY PROFILE DIGITAL FECES ANALYZER

Culture 01 12 Technology Advantages & 8 Performance Advantages 05 AI ERA OF FECES ANALYSIS


Profile 02 Specification & Parameter 11
More Accurate

Faster

More Powerful

03
SUPPORTING REAGENT,
CONSUMABLES AND FECES OVERALL PLAN
Quick guide on clinical application 14
FA280/S Fecal biomarker detection item 15
Fecal Occult Blood & Transferrin Combo Test 16
Lactose Test 18
Calprotectin Test 19
Lactoferrin Test 20
H.Pylori Antigen Test 21
Rotavirus Antigen Test and Adenovirus Antigen Test 22
Fecal Morphology Quality Control 25
Hemoglobin &Transferrin Non-quantitative Quality Control 26
Sample Diluent / Flushing Fluid / Concentrated Cleaning Fluid 27
Sample Collection Tube 28
05
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 06

MORE ACCURATE

01 Intelligent Dilution 02 AI Locating and Tracking


Dilute to standardize concentration according AI locating and tracking technology, Positive objects nowhere to
to different sample status hide.

AI ARTIFICIAL INTELLIGENCE
ERA OF FECES ANALYSIS
03 Constant Temperature Incubation (CTI)
CTI system ensures more accurate detection

05 Upgraded Patent Sample Collection Tube


04 Auto-Identification on Parasite Eggs
Accurately distinguish liver fluke, hookworm, roundworm,
whipworm, pinworm, tapeworm etc.
The internal structure of eggs is clearly distinguishable.

Fully sealed in whole detection process, odorless and leak-proof, 06 Independent Quality Control Systems
high transparency,greatly improves the detection rate of positive
The professional QC systems come from the
components. original manufacturer to ensure the test
Patent No.: ZL 2017 1 0439186.4 results are accurate and reliable.
12 Technology Advantages & 8 Performance Advantages

FA280 FULLY AUTOMATIC DIGITAL FECES ANALYZER

FASTER

07 Three-channel Multi-field Imaging 08 More Test Kit Bins, Larger Capacity


Multi-field tomography equipped with three-channel 6 test kit bins, load up to 300 pieces at one time
CMOS microscope, makes the detection faster.

09 Sample Rack Cyclic Loading


Cycle loading, Batch load at any time, load up 50 samples at one time

MORE POWERFUL

10 No smell, No leakage, Biosecurity 11 Global Exclusive Pneumatic Blending


Sealed, odorless and leak-proof in whole test process, prevent Patent Technology
biological and environmental pollution
Fully sealed high frequency reciprocating pneumatic mixing, careful
care of samples, ensure biological safety, improve detection rate
Patent No.: ZL 2013 1 0416170.3

12 Remote Assistance and Intelligent Management of Fault Diagnosis


Quick response on customer requirements, Smart management of
onsite consumables, Fault self-diagnosis
07
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 08

Fully Sealed Test System Ensure Biosecurity


AI Locating and Tracking:
Positive objects, nowhere to hide
Sealed sample collection tube, Convenient to transport
Suspicious target found in LPL
No smell & No leakage, Improve work environment

Prevent biological pollution and hospital infection Original “AI Locating and Tracking” technology,

Minimize environmental pollution avoidance the suspicious targets are located accurately and

A joy mood for technicians captured by high-definition HPL, the internal

structure of pathological components is more


Locating suspicious coordinate, clear and identifiable;
photo by HPL
Unique “Zoom in” in the current view function not

only facilitates the identification of fine structure

such as small warts, egg caps, acromion etc., but

also facilitates the reconfirmation of suspected

components;

CMOS microscope multi-layer tomography

imaging, the image is clearer;


Before Analyzing Be Analyzing After Analyzing

Sample collection tube is Pipeline system is fully Waste samples, test kits and
fully sealed after sampling. sealed when be analyzing. liquid are sealed collected.

Intelligent Dilution
Constant Temperature Incubation (CTI),
More accurate detection
AI Identification, Clear Images,
Rich morphological characteristics By detecting the sample turbidity, intelligently

secondary dilution would be made, to meet

Established and improved powerful RDS based on AI technology; standard concentration, to avoid invalid results

Accurately distinguish liver fluke, hookworm, roundworm, whipworm, for microscope images and test kits, caused by

pinworm, tapeworm etc; over concentration or too thick, at the same time,

it makes foundation for further quantitative test in


Auto identification on RBC, WBC, Phagocyte, Pus Cell, Fungus spore,
Indoor T:10℃ No CTI Indoor T:30℃ No CTI terms of sample preprocessing.
Charcot-Leyden crystal, Fat globule etc. visible components;
The immune response of the reagent is more
Parasite Model is recommended for High prevalence area of parasites;
sensitive to temperature, and the difference in
Continuously update the cloud database, offering richer
environmental temperature will directly lead to
morphology index; the deviation of the test result; Constant
Images are from screen shot of FA280 Feces Analyzer, no comparable Temperature Incubation (CTI) can avoid the
among each egg size. Indoor T:10℃ With CTI Indoor T:30℃ With CTI influence of the environmental temperature on

the test result of the test kit.


09
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 10

Three-channel, Six Test Kit Bins,


meet requirement on high throughput Fluid path optimization of segmented
and personalized demand to avoid cross-contamination
The needle does not contact the sample when add liquid and gas,

no residue inside or outside the needle;


Flushing Fluid Sampling suction needle up-through positioning, avoiding suction

with residue filtered;


Air

Column isolation“sandwich" suctioning, ensure integrity of sample


Counting cell with three-channel, Sample testing≥80
Sample
and no residue;
tests/hour;
Sampling needle spring-flushing, avoid residue inside or outside
Standard Six Test Kit Bins, meets personalized demand;
the needle;
Customized test item for each bin;
Flushing fluid adapted fluid system, avoid fluid residue in-pipe;
6-12 POCT test item would be tested at one time.
Counting cell path is no dead corner with streamlined design,

avoiding residual liquid in the cell;

High pressure pulse counting cell cleaning, clean thoroughly;

Test kit dropping needle non-contact to drop sample liquid, then

high pressure pulse cleaning, avoiding residue in needle-head;


“Sandwich” Suction
Daily concentrated cleaning fluid to flush, removing stubborn blot;

Automatic analysis of full hosting,


stable and reliable system Remote assistance center
online responding and upgrading

Analysis without staff on duty; Remote assistance can respond to your

Highly intelligent system automatic control and alarm; r e q u e s t s m o r e q u i c k l y, i n c l u d i n g

Resume operation immediately after the alarm information troubleshooting, maintenance, and

is processed; software upgrades, saving your valuable

Real-time consumable management, “Flight-refuel” type to Ready time to the maximum;

renew all consumables; At the same time, communicate at

The comprehensive failure rate is much lower than similar ORIENTER expert platform to share

products. database or inquiry without barriers.


11
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 12

PARAMETER Main parameters


Index classification Item

Channel of counting cell Channel 3

Microscope light source LED


Index classification Item Main parameters

Objective lens 10X and 40X, automatic switch high/ low power dual objective lens.
Test speed ≥80 tests / hour Microscope
examination
Incubation temperature Image parameter 500w Pixel, global shutter
Accuracy: 37℃±1℃; Fluctuation ≤ 2℃
of reagent card
Automatic tomography acquisition, adjustable visual field, available
Drawing collection
Detection rate ≥95% positioning and tracking of suspicious targets.

Accuracy deviation in Automatic identification Automatic classification identification


≤20% (50~100 units/μL simulation samples)
counting
Performance index Reagent card channel,
6 channels, 50 test kits / channel
≤20% (50~100 units/μL simulation samples) quantity
Repeatability of formed
components CV% Sample volume 80μL, quantitative adding sample
≤15% (≥200 units/μL simulation samples)

Incubation function 37℃ thermostatic incubation


Carrying pollution rate of formed components detection ≤0.05%.
Reagent card test
Carrying pollution
Incubation time 4 min.
No carrying pollution on the reagent card test.
It automatically takes photos at regular intervals, and automatically
The samples are automatically located and taken pictures, and automatically Detection
Color and characteristic recognizes and interprets.
identified and interpreted color characteristics.
Waste card recycling Automatic waste card recycling.
RBC, WBC, Pus Cell, Fungal Spores, Charcot-Leyden Crystal, Fat Globules,
Formed components
Parasie Eggs.
Test item
Fecal Occult Blood (FOB) Transferrin (TF) Self-checking function Available power-on self-test function.
Fecal Occult Blood&Transferrin(FOB&TF) Calprotectin (Cal)
Test kit
Rotavirus Antigen (RV) Lactoferrin (LF)
Alarm function of consumables shortage (reagent card, flushing fluid, diluents).
Adeno/Rota Virus Antigen (RV&ADV) H.Pylori Antigen (HP) etc

Its fully sealed design ensures the whole process of sealing before testing, Alarm function Alarm function of Waste fullness (waste liquid pool, waste card warehouse).
Sample collection tube
during testing, and after testing.

Sampling collection amount Collect 1 level spoon, about 0.5g Alarm function of abnormal incubation temperature.

Each sample collection tube is pasted with a sampling guidance label to The instrument status indicator light can indicate that the instrument is in the
Sampling instructions
guide the patient to take the qualified samples. Status indication state of offline/sleep, self-test, ready, test, alarm, etc.
light function
Reagent card status indicator can indicate the presence /absence /
Sample inlet method Sampling in flow process, 50 samples in maximum can be loaded at one time. Other functional replacement status of each reagent card channel.
indicators

Sampling and Mixing method of sample Pneumatic mixing LIS connection Support local model, simplex and duplex communication
pretreatment

Dilution function of sample Smart dilution FA280: Available


Build-in barcode scanning
Sample filtering and It automatic filters sample residues with enrichment of formed components, FA280S: Not Available
enrichment function and conducts the intelligent secondary dilution.

Automatically suck samples up and automatically allocate samples Support. It can perform instrument calibration and reagent calibration, and
Suction and allocation
required for microscopy and reagent card detection; 1400μL of suction Quality control functions
sample functions effectively control the difference between instruments and reagent batches.
sample amount.

Pipe cleaning function Self-cleaning Remote Assistance Support. It includes troubleshooting, maintenance and function upgrades.
13
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 14

03
FECAL BIOMARKER CLINIC APPLICATION
QUICK GUIDE

Feces is the final product of food metabolism in the human


body, and it is one of the three major clinical routine test
REAGENT & CONSUMABLE samples, which can provide important diagnostic evidence
for clinic, especially related diseases of the digestive tract.
FECES TEST TOTAL SOLUTION
The detection of proteins, microorganisms, metabolites and
other markers in feces is helpful for early diagnosis and
screening of digestive tract bleeding, inflammation,
infection, metabolic diseases and digestive tract tumors.

Definition of Fecal Biomarker:


It is a kind of substances that can be detected in the fecal

CREATIVE QC PRODUCT medium that have cell, biochemical or molecular changes.


They are either not present in normal human feces, or their
IMPROVE QC SYSTEM OF FECES TEST
content in feces greatly exceeds the content in normal feces.
STANDARD SAMPLE COLLECTION Their presence or changes in quantity can indicate

MATCHED WASH BUFFER symptoms related to infection, inflammation, bleeding,


metabolic abnormalities, and tumors in the digestive tract.
INDEPENDENT TEST KIT Combined with other examinations, they can help the
diagnosis, classification, prognostic judgment, and efficacy
evaluation of digestive tract related diseases.

Clinic Application of Main Fecal Biomarker:

01 02 03 04 05
Bleeding Inflammation Infection Metabolism Tumor

HPSA FOB
FOB Cal RV-Ag TF
Lactose
TF LF ADV-Ag HPSA
15
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 16

FA280 FECAL BIOMARKER FECAL OCCULT BLOOD & TRANSFERRIN


TEST ITEMS FOB&TF Combo Test Kit

01 02 03
Items Reference Test Range Category

FOB (Fecal Occult Blood) Negative 0.2~2000μg/ml


Digestive Tract Bleeding;
Colorectal Cancer Screening
TF (Transferrin) Negative 0.04~400μg/ml

Cal (Calprotectin) Fecal Occult Blood (FOB) Transferrin (TF) Fecal Occult Blood & Transferrin (FOB&TF)
<15μg/g 15~3000μg/g
Test Kit (Colloidal Gold) Test Kit (Colloidal Gold) Test Kit (Colloidal Gold)
Digestive Tract Inflammation

LF (Lactoferrin) <10μg/g 10~2000μg/g

LA (Fecal Lactose) <0.05g/L - Digestive Tract Metabolism

Digestive Tract Infection:


HPSA (Helicobacter pylori Stool Antigen) Negative - Gastric Cancer Screening
Orienter recommends combined immunization to test hemoglobin and

RV-Ag (Rotavirus Antigen) Negative - transferrin in human feces sample for full screening bleeding of the
entire digestive tract and early warning of early digestive tract tumors.
Digestive Tract Infection

ADV-Ag (Adenovirus Antigen) Negative -

PERFORMANCE ADVANTAGES

High Detection Rate:

Combo test of hemoglobin and transferrin in feces sample, and the


detection rate of fecal occult blood are higher than that of single detection
FA280 can provide multi-platform tests for fecal biomarkers, which are tested simultaneously; method, which can effectively improve the detection rate and accuracy.

6 channels, can detect 6-12 biomarkers at the same time; High Specificity:
Monoclonal antibody, not affected by other substances or animal blood.
The instrument automatically interprets the results to avoid human operation errors;
High Sensitivity:
The minimum detection limit of hemoglobin is 100ng/mL,
The fully sealed sample processing and analysis process: high biosecurity, avoiding secondary pollution. The minimum detection limit of transferrin is 40ng/mL.

Fast and accurate:


Quantitatively add 80μL diluted sample,
4 minutes timed photographing and automatically interpret the results.

Automatic detection:
Exclusively be applied to Orienter feces analyzer, providing a
comprehensive automatic solution for the laboratory.
17
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 18

FOB&TF Combo Test Kit, not hemoglobin only!

FOB
FECAL LACTOSE
100ng/ml 2000μg/ml Lactose is a unique carbohydrate in human and mammalian Performance Feature
milk. Each 100mL mature breast milk contains 7.2g lactose
(7.2%); 100mL milk contains 4.7g lactose (4.5-5.0%), which Good specificity: Not affected by other reducing sugars
0ng/ml 1600ng/ml 20000μg/ml is important for infants and young children energy source. (fructose, maltose, etc.);
Galactose, a decomposition product of lactose, is an
important substance that constitutes the brain and vital High sensitivity:The lowest detection limit can reach 0.05g/L;
TF organs, and promotes the development of the brain in
infants; Lactose improves the intestinal flora of infants and Simple operation: Only 4mins in the 37°C incubation tank,
young children; Lactose promotes calcium absorption in 10-15mins under normal temperature;
Hb ≤ 100ng/mL 100ng/mL ≤ Hb<1600 ng/mL 1600ng/mL ≤ Hb<2mg/mL infants and young children.

High compliance: Easy to get feces sample, not affected by


FOB-、TF- FOB+、TF- FOB+、TF+ More than 50% of the population has lactose intolerance or poor compliance of infants and young children.
No bleeding or micro-bleeds Micro-bleeds in the lower Gastrointestinal bleeding different degrees of lactose intolerance, and the proportion
of the gastrointestinal tract gastrointestinal tract of adults with lactase deficiency is higher. People who are
lactose intolerant will experience varying degrees of
diarrhea while drinking human milk or cow milk. Interpretation of Fecal Lactose Test Result
2mg/mL ≤ Hb<20mg/mL Hb ≥ 20mg/mL

FOB-、TF+ TF-、FOB-

Bleeding in the upper gastrointestinal tract or heavy GI bleeding Sample appearance: black stool or red, <0.05g/L Lactose Tolerance
Clinical symptoms such as hematemesis, hemoptysis Clinical Significance
Sample appearance: tarry stool or flesh pink
Light Lactose
0.05g/L~0.5g/L
Intolerance
Conversion of Unit: 1μg/mL=1000ng/mL; 1mg/mL=1000μg/mL; 1g/L=1mg/mL 01 Evaluation of human lactose tolerance.

02 Differentiate and investigate cause of diarrhea. >0.5g/L Lactose Intolerance


Clinical Value
03 Guide the correct choice of dairy products.

04 Provide dietary guidance to patients. Invalid Invalid


FOB TF Interpretation

1 Negative (-) Negative (-) No GI bleeding or physiological bleeding


Modified Banana Negative Coincidence Rate 95.0%
(1) Micro-bleeds in the lower GI tract, TF content is Items Total
below the detection limit;
2 Positive (+) Negative (-) - + Positive Coincidence Rate 96.1%
(2) Bleeding in the GI tract, but the content of TF in
the plasma itself is low.

(1) Upper GI tract bleeding, Hb is broken, negative - 207 3 210 Coincidence Rate 95.3%
result; Enzyme
3 Negative (-) Positive (+)
(2) Heavy GI bleeding, the content of Hb over the Chromatography
detection limit, causing Hook.
+ 11 74 85 NPV 98.6%

4 Positive (+) Positive (+) Upper and lower GI moderate bleeding


Total 218 77 295 PPV 87.1%
19
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 20

CALPROTECTIN | IBD SCREENING LACTOFERRIN | IBD SCREENING


Screening for Inflammatory Bowel Disease (IBD) Screening for Inflammatory Bowel Disease (IBD)

Easy Sample Collection without Special Treatment


Easy Sample Collection without Special Treatment
Semi-Quantitative Based on Color Intensity
Stable and Clinical Valuable
Stable and Clinical Valuable
Simple and Rapid
Simple and Rapid
High Sensitivity & Specificity
High Sensitivity & Specificity

EFFECT COMPONENTS EFFECT COMPONENTS

01 Distinguish Inflammatory Bowel Disease (IBD) 01 Distinguish Inflammatory Bowel Disease (IBD)
and Irritable Bowel Syndrome (IBS) and Irritable Bowel Syndrome (IBS)

02 Assess inflammatory activity of IBD 02 Assess the prognosis of IBD

03 Assess cure conditions of mucosa of IBD


Calprotectin (Cal) Test Kit (Colloidal Gold)
03 Screening for IBD
Lactoferrin (LF) Test Kit (Colloidal Gold)
04 Screening for IBD

SPECIFICATIONS SPECIFICATIONS

Specifications 25 pcs/box 50 pcs/box 100 pcs/box Specifications 25 pcs/box 50 pcs/box 100 pcs/box

Calprotectin Test Kit 25 pcs 50 pcs 100 pcs Lactoferrin Test Kit 25 pcs 50 pcs 100 pcs

Sample diluent tube 25 pcs Sample dilution tube 25 pcs

Color card 1 pcs 1 pcs 1 pcs Instructions 1 pcs 1 pcs 1 pcs

Instructions 1 pcs 1 pcs 1 pcs

Storage conditions: 4℃~30℃ avoid light, dry preservation, without freezing . Validity: 24 months Storage conditions: 4℃~30℃ avoid light, dry preservation, without freezing. Validity: 24 months
21
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 22

HELICOBACTER PYLORI STOOL ANTIGEN (HPSA) ROTAVIRUS (RV) ANTIGEN & ADENOVIRUS (ADV) ANTIGEN

Helicobacter pylori (H. pylori) Rotavirus (RV)

The only microorganism species known to survive in the The main cause of diarrhea in infants and young children

human stomach, and one of the important pathogenic worldwide. Almost every child about five years old in the

factors of chronic gastritis, peptic ulcer and gastric cancer. world has been infected with rotavirus at least once.

WHO/IARC has designated Helicobacter pylori as a Class I


carcinogen.

Adenovirus (ADV)

The second cause of viral gastroenteritis in children. It is


mainly divided into groups A-G. Among them, type 40 (Ad40)
Route of Transmission: Clinical Significance of HPSA Test:
and type 41 (Ad41) of group F are present in about 70% of
adenovirus-associated gastroenteritis. Adenovirus infection
Oral route: The bacteria are present in periodontal and 1. H. pylori symptom infection observation is mainly prevalent in winter and spring, and it is prone to
saliva 2. Evaluation of the curative effect of H. pylori eradication outbreaks among kindergartens, schools and recruits
Fecal-oral route: H. pylori can be excreted with feces to therapy camps.
contaminate food and water sources. Therefore, it can be 3. Observation of recurrence and reinfection after anti-HP
spread through diet treatment
Close contact: H. pylori infection has obvious familial
Common Identification Points of Viral Infectious Diarrhea
4. Epidemiological investigation of H. pylori infection and
aggregation community infection screening
Iatrogenic infection: The bacteria can be spread 5. Non-invasive screening, good compliance for children,
Pathogen RV ADV Norovirus (NV)
between patients through contaminated dental the elderly, pregnant women, mental patients and other
Susceptible A, C group: 6-24 months child patient Generally, Generally,
instruments and gastrointestinal endoscopes special populations population B group: Adult mainly under 3 years old mainly older children and adults
Route of Fecal-Oral, Respiratory, Fecal-Oral,
Fecal-Oral, Close Contact, Respiratory
transmission Water, Close Contact Contaminated water and food

Virus viability Several days to weeks 1 week to several weeks Several days
Characteristics of Stool Pathogen Antigen Detection
Prevalent More common in autumn and winter, Winter and spring
Summer and autumn
features more children than adults (from November to April)
Good specificity: accuracy similar to Urea Breath Test (UBT)
Incubation
1-3 days 3-10 days 1-2 days
High sensitivity: antigen detection based on the principle of period

monoclonal antibodies, more directly reflects the immediate Main Acute onset, low-grade fever, Most are asymptomatic, diarrhea, Acute onset is mainly mild,
symptoms nausea, vomiting, diarrhea, etc. low fever, vomiting, etc. nausea, vomiting, diarrhea
gastrointestinal infection
Duration 3-5 days 8-12 days 2-3 days (Most are self-healing)
Automatic and fast: the analyzer automatically interprets, and
Daily number
the result can be obtained in only a few minutes. 10+ times 10+ times 4-8 times
of diarrhea
Non-invasive and simple: non-invasive detection, not affected
Diarrhea stool
Watery or yellow-green loose stools Yellow watery or watery stool Watery stool
by poor compliance of infants and young children. character
23
PAGE 24

RV-Ag & ADV-Ag

INTERPRETATION TEST RESULT Rota/Adeno Rota/Adeno Rota/Adeno Rota/Adeno


H. pylori, Rotavirus Antigen, and Adenovirus Antigen
ID ID ID ID
HPSA, RV-Ag Interpretation:
Positive: a purple-red band appears on the test line and quality control line
Negative: a purple-red band appears on the quality control line only
C C C C
Invalid: no purple-red band at the position of the quality control line
A A A A
R R R R
RV-Ag & ADV-Ag Interpretation:
Positive: RV positive: a purple-red band at the position of the R test line and the quality control line
ADV positive: a purple-red band at the position of the A test line and quality control line
RV and ADV positive: a purple-red band at the position of the R and A test lines and quality control line
S S S S
Negative: a purple-red band appears on the quality control line only
Invalid: no purple-red band at the position of the quality control line

HPSA, RV-Ag A&R Positive A Positive R Positive Negative

Rota/Adeno Rota/Adeno Rota/Adeno Rota/Adeno


ID ID ID ID
ID ID ID ID

C C C C
C C C C
T T T T A A A A
R R R R

S S S S
S S S S

Positive Negative Invalid Invalid Invalid Invalid Invalid Invalid


25
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 26

FECAL MORPHOLOGY QUALITY CONTROL HEMOGLOBIN & TRANSFERRIN (FOB&TF)


NON-QUANTITATIVE QUALITY CONTROL

EFFECT COMPONENTS EFFECT COMPONENTS

Standardize QC
Standardize QC

RBC QC WBC QC
Teaching
Indoor QC
demonstration

Testing Indoor QC
equipment

Testing equipment

Fat Globule QC Mycete QC

SPECIFICATIONS SPECIFICATIONS

Specification: 4mL/bottle, 4 bottles/box Specification: 6mL/bottle, 4 bottles/box


Character: Liquid Character: Freeze-dried powder (Redissolved with 6mL purified water/distilled water)

Storage: 2℃~8℃ seal and avoid light Storage: 2℃~8℃ seal and avoid light
Validity: 12 months Validity: 24 months

THE FIRST INNOVATIVE QUALITY CONTROL PRODUCTS


PERFECT THE QC SYSTEM OF FECES TEST IN THE LABORATORY
27
MEET YOUR REQUIREMENTS, WE'VE BEEN WORKING ON IT PAGE 28

SAMPLE DILUENT SAMPLE COLLECTION TUBE

EFFECT FEATURES SPECIFICATIONS

01 Sample Dilution 01 U-shaped filter patent design Packing: 50pcs/tray, 400pcs/carton

02 Keep visible component from being destroyed


Perfect match with the analyzer
Storage: 4℃~30℃ avoid light
Increase the positive detection rate
Validity: 36 months
02 Fully sealed
SPECIFICATIONS No liquid/gas leakage
Ensure biosecurity
Packing: 2.8L/barrel, 2.8L/barrel×2

Storage: 4℃~30℃ avoid light, dry preservation, without freezing.

Validity: 12 months

FLUSHING FLUID
CONCENTRATED CLEANING FLUID

EFFECT

01 Instrument pipeline flushing and cleaning

02 Instrument daily maintenance

SPECIFICATIONS
PATENT DESIGN, PERFECT MATCH WITH THE ANALYZER
Flushing Fluid Packing: 5L/barrel, 10L/barrel
FULLY SEALED, ENSURE BIOSECURITY, ODORLESS Patent No.: ZL 2017 1 0439186.4
Concentrated Cleaning Fluid Packing: 10mL/pcs×10, 100mL/bottle

Storage: 4℃~30℃ avoid light, dry preservation, without freezing.

Validity: 24 months

You might also like