2K full-color clear imaging, reducing the rate of manual microscopic EU-5300 Pro EU-5300 Pro

review for positive samples Automated Urinalysis System Automated Urinalysis System

Colorful imaging technique which is close to manual microscopic satisfies what you need for releasing a report

Testing principles Automated focusing


Unveiling the Unseen by
Dry chemistry: Photoelectric colorimetry, refractometry, and
Nephelometry method.
The system automatically performs the focusing process, without
the need for manual operation or the use of focus reagents
Unlocking Unparalleled Clarity
Formed elements: Machine vision (Digital imaging technology )
STAT function
Reportable parameters Independent STAT positions for emergency samples at any time
Physical: Specific gravity, color, and turbidity
Dry chemistry: 11/14 items Strips loading capacity
LEU, leukocyte NIT, nitrite 200
URO, urobilinogen pH, power of hydrogen
PRO, protein BLD, erythrocyte Sample Volume
BIL, bilirubin MCA, micro albumin 2.5ml minimum required sample volume
GLU, glucose CRE, creatinine
VitC, vitamin C CA, calcium Sample type
SG, specific gravity P/C, protein-to-creatinine ratio* Native urine sample
KET, ketones A/C, microalbumin-to-creatinine ratio*
Note: Parameters indicated with an asterisk (*) are intended for calculated parameters
Barcode
Formed elements: 31kinds Built-in barcode reader
RBCs (total) BACT, bacteria
Normocytic, Nor-RBC BACTc, coccus Tube specification
Macrocyte, Mac-RBC BACTr, rod Length ≤110mm Diameter 15-16mm
Microcyte, Mic-RBC YST, Yeast
Crenocyte, Cre-RBC Squamous epithelial cell, SEC Communication
High analysis volume for sediment particles to avoid missed Annular RBCs, Ann-RBC Non squamous epithelial cell, NEC Bi-direction LIS, automated barcode identification for testing
diagnosis of positive samples Acanthocytes, Aca-RBC
Humped Spherocytes, Hpd-RBC
CRYS, Crystals
Mono-hydrate calcium oxalate crystal, Caoxm Dimensions and Weight
Jagged RBCs, Jag-RBC Di-hydrate calcium oxalate crystal, Caoxd WxDxH: 600x770x530(mm) / ≤71.5Kg
Ghost RBCs, Gho-RBC Uratic crystal, URA
Fragmented RBC, Fra-RBC Triple phosphate crystal TRP
Other abnormal RBCs, Oab-RBC HYAC, hyaline cast
RBCs
Anisocytosis Ratio, Ani-Ratio UNCC, unclassified cast
MorInfo-RBC MUC, mucous strands
The system
相机
captures up相机
to 60 clear WBCs WBC, white blood cells Sperm, SPRM
images from the samples. Utilizing
沉降富集 WBCC, white blood cells clump
advanced algorithm, the system can Crystals
precisely identify various types of Throughput
Dry chemistry mode: ≥160 tests/ hour
formed elements from panoramic Epithelial cells Formed element mode: ≥70 tests/ hour
images, thereby minimizing the
Hybrid mode: ≥70 tests/ hour
chances of missed positive samples.

www.mindray.com
P/N:ENG-EU-5300 Pro-210285X6P-20230822
©2023 Shenzhen Mindray Bio-Medical Electronics Co.,Ltd. All rights reserved.
Three features integrated in a single system to manage the unique Coming standard with RBC phase parameters to help rapidly identify Dry chemistry analysis delivers precise results that are better
workflow needs of your lab the source of hematuria aligned with the analysis of formed elements
The integration of dry chemistry, formed element, and RBC phase analysis leads to a great improvement in time and space The system can automatically provide parameters for various types of urinary RBCs, presenting histograms that clearly The test strip for dry chemistry analysis are optimized to enable precise sampling, thereby ensuring accurate results,
management efficiency. Even a single person can easily manage the TAT requirements during the peak hours of your lab. depict the size, shape, and hemoglobin content of these cells. By analyzing the results of RBC morphological variations consistent performance, and greater ease of use.
(MorInfo-RBC: homogeneous/heterogeneous/mixed) and utilizing RBC morphological images, a thorough review and
validation process can be conducted to identify the source of hematuria rapidly and precisely.
The optimized test strip and sampling method result in an increase in the
color development speed and the resolution between gradients
Normocytic, Nor RBC Microcyte, Mic-RBC Macrocyte, Mac-RBC Crenocyte, Cre-RBC Jagged RBCs, Jag-RBC
Comparison of resolution at different gradients between traditional and new test strips
Traditional New
Accurate 1
sampling -

l RBC phase analysis


0.9

Manua
0.8
±

Aut
0.7 1+

ysis

Reflectance
om 0.6 - 2+ 3+

l
±

ana ate 0.5


1+

y d
str
0.4

i for 0.3
me
em
2+
0.2 3+

ch de 0.1

y le Annular RBCs, Ann-RBC Acanthocytes, Aca-RBC Ghost RBCs, Gho-RBC Fragmented RBC, Fra-RBC Humped Spherocytes,
Hpd-RBC
0
0 15 70 125 500
Unit
Leu/μL
r
dd

Formed element concentration

m
New strips

en
ate

Traditional New

ta
tom

na
— ± 1+ 2+ 3+ — ± 1+ 2+ 3+

lys
Au

is
Safety and ease of use, and efficient review
The system supports running urine samples with closed tubes, ensuring enhanced levels of biosafety.
With the inclusion of Mindray data management software—LabXpert, the system shows dry chemistry, urine formed
RBC phase histograms showing the reference ranges and their clinical significance elements, and RBC phase results on a single screen, significantly improving the efficiency of report validation.
RBC size histogram RBC shape histogram RBC chroma histogram

Ratio Reference range: [40, 90] Ratio


100%
Reference range: [0.8, 1.0] Ratio Reference range: [25, 55] Dry chemistry results
100% 100%
90% 90% 90%
80% 80% 80%
70% 70% 70%
60% 60% 60%

Histogram 50%
40%
50%
40%
50%
40%
Formed element results
30% 30% 30%
20% 20% 20%
10%
10%
Area Roundness 10% Saturation
0 14 28 42 56 70 84 98 112 126 140 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 10 20 30 40 50 60 70 80 90 100

Unit of measurement um^2 Dimensionless Dimensionless

Normocytic, Nor-RBC 40-90 0.8-1.0 25-55

Macrocyte, Mac-RBC 50-85 0.75-1.0 25-55

Microcyte, Mic-RBC 20-55 0.8-1.0 35-60

Crenocyte, Cre-RBC 15-50 0.75-1.0 35-60

Annular RBCs, Ann-RBC 15-70 0.7-1.0 10-50

Acanthocytes, Aca-RBC 45-80 0.6-0.9 30-60

Humped Spherocytes, Hpd-RBC 40-85 0.55-0.8 25-55

Jagged RBCs, Jag-RBC 20-75 0.75-1.0 10-50

Ghost RBCs, Gho-RBC 10-50 0.75-1.0 5-18

Fragmented RBC, Fra-RBC 20-55 0.6-0.9 30-60


Left shift indicates a decrease in Supports aspirating samples for
Left shift indicates a decrease in size The roundness decreases when hemoglobin concentration
Clinical significance analysis with special closed tubes,
Right shift indicates an increase in size there is any abnormality Right shift indicates an increase in RBC phase results
hemoglobin concentration greatly contributing to biosafety