You are on page 1of 1

1.missing Member sizes (dimensions of beams and columns).

2.Connections between beams and columns are not shown. Details needed on bolt
sizes, plate sizes, weld specifications.

3.he material specifications for the structural elements like beams and columns are
not clearly mentioned. It will be good to include the grade of concrete and type of
steel to be used.

4.Specification of fabrication and erection to be provided.

5.Spacing of Columns is not dimensioned.

6.drainage design and surface water disposal details missing.

7.Dimensioning and placement of loading doors/openings not clear. Clear opening


dimensions as per machinery size needs to be provided.

8.Structure height seems less considering typical equipment clearance requirements.


Headroom needs re-checking.

9.No connection/joint details for pillars, beams and walls. Proper joints are
important for stability during construction as well resisting seismic forces.

10.The type of liquid that will be stored in the tank.

11.provide information about the operating conditions of the internal floating roof
system, such as the temperature and pressure ranges. This information would help to
ensure that the steel sections and connections are selected appropriately.

12.The seismic and wind loads.

13how to ensure tank has a proper venting system to prevent the accumulation of
vapors inside the tank.?

14.how to ensure foundation of the tank are strong enough to support the weight of
the tank and its contents, including the floating roof system.

15.kindly check and clarify The thickness for leg support in Drawing is 2mm but in
staad considered as 4mm.

16.why no Design parameters in staad.

17 utilization ratios are missing in staad.