= All areas meet requirements of ANSI | ESD S20.

20 Date -
ESD CONTROL = Areas of ESD Control Plan that should be addressed Temp -
SURVEY NOTES = Not part of current program or not verified RH% -
Company: Location | Address
Technical Element Equipment Area: Area:
Sec 1.1 - Verify Outlets AC Outlet
Analyzer

Sec 1.2 Personnel Grounding Access Controller: Yes | No Access Controller: Yes | No
Verification Manual Log: Yes | No Manual Log: Yes | No

Sec 1.3 Continuous Monitors Cord (red Snap)


no resistor
single wire

Sec 1.4 Wrist Strap R-Meter


< 3.5 x 107 ohms RTG with Person & Handheld
Electrode

Sec 1.5 Foot Grounders R-Meter


< 1 x 109 ohms RTG with Person & Handheld
Electrode

Sec 1.6 Flooring R-Meter Paint | Floor Finish | Tile Paint | Floor Finish | Tile
< 1 x 109 Rtg

Sec 1.7 Footwear | Flooring System R-Meter


< 1 x 109 Rtg Body Volt
< 100 volts Peak Meter
Sec 2.1 Defined ESD Protected Area Floor Tape | Signs | Access Controlled Floor Tape | Signs | Access Controlled
(EPA)

Sec 2.2 Worksurfaces R-Meter 2-layer | 3-layer | Homogeneous | Laminate 2-layer | 3-layer | Homogeneous | Laminate
1 x 106 < 1 x 109 Rtg

Sec 2.3.1 Material | Handling R-Meter & Totes | Bin Boxes | Trays | Foam | Bags Totes | Bin Boxes | Trays | Foam | Bags
Packaging Within EPA Concentric
< 1 x 1011 Rtt | < 125V @ 1in Ring Probe

Sec 2.3.1 Packaging Outside EPA R-Meter & Mailers | Foam | Bags Mailers | Foam | Bags
Packaging Used Outside EPA Concentric
< 1 x 1011 Rtt | < ±125V @1in Ring Probe

Sec 2.4 Insulators Static Field


< 125V at 1 inches Meter
< 1000V at 12 inches
Sec 2.5 Ionization Ionization
Offset Volltage < ±35V Test Kit
Discharge Time 1000V
Sec 2.6 Seating R-Meter
< 1 x 109 Rtg Static Field
Meter
Sec 2.7 Shelving R-Meter
< 1 x 109 Rtg

Sec 2.8 Carts (Mobile Equipment) R-Meter


< 1 x 109 Rtg

Sec 2.9 Garments R-Meter


Static Control Garment (SCG) < 1 x 1011
Groundable SCG < 1 x 109
Groundable SCG System < 3.5 x 107

Survey and Measurements Made By To have your survey reviewed at no charge. Scan your notes and
Name email us at Service@Desco.com

Email We can provide a written follow up report with recommendations for


areas of your ESD Control Plan to address, and products that meet
Phone# ANSI | ESD S20.20 requirements.