You are on page 1of 6
FRP STORAGE TANK | a NONTFOME oe @ RUST PRES o! a , @ SEAMLESS = 2 - B SUN DGFT RESIST G @ COLD WATER OR mui TANK | (al CHISMICAL a) rece mul TANK MT 220/C JISA4110 : 1989 MS 1225: PART2 : 2006 Mui G Tank” za | 1000 | mrz2o | am am | arm 440 | 2000 | wrsao | am | am [ am | 4mm eso | 3000 | merso | om am | smn 80 | 4000 | nersso [am | am [am [6mm i320 | 6000 | wr-isz0 fam | am | am [7mm 60 | e000 | wt-vzo0 | 2m | am | am | orm 11000 | wrz20c | 135m 440 | 2000 | wrasoic | 170m | am 4mm 680 | 3.000 | mr-seoic | 200m | am sem 60 | 4.000 | wrssoic | 23am | im ‘om 60 ao | 360 | mrs0 3a ar 20 soo | 450 | mrtoo 3 ae EB 180 | 680 | nrotso | ae 3 2 200 | a0 | mro-200 | 4s ae" 24 250 | 1.140 | mro-250 | 60° o 2 250 | 1.140 | ner-250 ae ae 30" 300 | 1.360 | net-300 ot st 32 400 | 1.920 | nev-400 o e a o~ OPEN TOP SERIES {Farad Gate 8 Above On) Cer aa eeu ko aa ing Sa a Cree} Tensile strength MNim? 103.0 70 (min) Bending strength MNin? 182.4 100 (min) Elastic modulus in bend MNIm 7306.0 000 (min) Moulded surface 68 (max) 43 (min) ea ceeme Barcol 50 Exposed surface 62 (max) 42 (min) Water absorption % 015 7.0 (max) Lap shear strength MN 11,03 70 (rin) LEVEL INDICATOR (FOR 3000 GLAs & ABOVE ONLY Height tometer INTERNAL & EXTERNAL LADDER IL - (FoR 3000 GAs & ABOVE ONLY NOTE: @ All dimension are rounded-off to the nearest 10mm (or 0.5 inch). (© Only water tanks which 3000 Gallons and above will be supplied with internal/external ladder and level indicator (© Tank properties subject to change without prior notice © Dimension given above ate for space required for installation purpose only. (© The manufacturer reserves the right to amend or change the design, patterns and specifications without any prior notice as continuous improvement achieved. Mui Tank™ CIRCULAR CLOSED TOP SERIES (Dia. 1.2m, 1.5m, 2m, 2.4m, 3m, 4m,5m, 6m, 7m) aE or ‘APPROX. | APPROX ‘APPROX. | APPROX. nieicnT | CAPACITY | ‘weicHT |tHickNess neicHT | CAPACITY | ‘Weight [THICKNESS (Gallons) (Gallons) (mm) (9s) (om) (mm) (kos) (mm) 7000 | 250 3 5-6 ‘ato | 5,000 732 7-9 7.200 | 300 60 5-6 270 | 6,000 323 7=10 ae 72 5-6 2530__| 7,000 290 a-n 2010 | 500 96 5-6 2800 | 000 | 4.168 | e=13 2410 | 600 710 5-6 3610 | 10,000 | 1332 | 8=13 #3000750 131 5-6 4330__| 12,000 | 1,604 B= 14 saz0_| 15.000 | ter [8-14 HEIGHT. | (Gatons) | Wien [GANS v220 | 20,000 | 2870 | 10-17 9,030 25000 | 3.865 | 11-19 4.030 400 76 5-6 #10000 | 27.680 | 4439 | 12-20 71280 500 35 5-6 7.540 600 107, 5-6 2,060 800) 730 5-6 HEIGHT. | (Gatons) | Want Temes 2570 | 1,000 182, 5-6 (om) 3,080 | 1,200 178: 5-7 1020 | 4400 450 5 #3,750__| 1,460 ant 5-8 200 800 esa] u 3,060 | 13,200 850 @ neiGHT | “Satonay | WEIGHT [THICKNESS 5,100 | 22,000 | 1,250 1 (nm) (kos) (mm) #6,120_| 26400_| 1,450 12 070 700 728) 5-6 71.160 800 136 5-6 WEDEEE carne | PROX | arrox 1,440 7,000 153, 5-6 weichT | “Qenciay | WEIGHT [THICKNESS 2170 | 1.500 208 5-8 (en) (kas) (mm) 290 | 2,000 286 6-8 “070 | 6,600 500 3 asi0_| 2,500 336 6-8 2,130 | 13,200 200 7 4330 | 3,000 429 5-8 3190 | 19,800 | 1,160 9 #5000 | 3.460 544 7-8 4250__| 26400] 1,500 1 5310 | 33,000 | 1,800 3 rrr Ezz APPROX. ] APPROX. HEIGHT | “eajonay | WEIGHT. [THICKNESS eee a (mm) (Kes) (enm) +000 | 1000 769 5-6 QE cpnciry | APPROX. | APPROX 1.510 | 1,500 221 5-8 HEIGHT | (Gatons) | May TANS 2,010 | 2,000 290) 6-8 co 2510 | 2,500 382 6-8 1040 | 6,800 750 5 S010 T3000 aos So8 2080 [17,600 | 1,050 7 Le ae = 3,120 | 26400 | 1,500 10 5.020 1 $000 ry 79 4,160__[ 35.200 1,900 2 Fe OO | EEO co =n) 5200 | 44,000 | 2,350 14 #6240 | 52.600 | 2,800 16 [Bena] APPROX. | APPROX. capacity HEIGHT | (Gallons) | WEIGHT [THICKNESS| — ¢ Maximum height of each diameters. (mm) (k98) (om) * Diameter Sm, 6m and 7m water tank to be assemble/ 280 | 2,000 326 6-8 fabricate at site 7.230 | 3,000 a2, 6-8 2570 | 4,000 551 7-9 3.210 5,000 681 79 3.850 | 6,000 786 7=10 5,140 | 8,000 qe | 8-13, 6420 | 10000 | 1,399 | 8-13 ¥7.500 | 14,680 | 1.711 14 INSTALLATION INSTRUCTION Open Top Series 0 oa 1. The centre-line of the Ball-Valve should be approximately 38mm T Vv from top of the tank. 2. backing plate must be used and fitted on the outside of the (2) oa tank vA 3. Place the tank on top a flat supporter, e.g. flat plywood or conerete at 90 degree angle vertcaly for a uniform pressure 4) Jo ° support over the tanks entire base. x“ vw 4. Support and align all pipes connecting to the tank DO NOT oot OVERTIGHTENED THE BACKNUT AGAINST THE S FIBERGLASS TANK. Sy x 5. Use only plastic, rubber washers and PTPE tapes when connecting and joining pipes and other attachments to the fiberglass tank. DO NOT USE PUTTY OR ANY FORM OF 6) JOINTING COMPOUND. Paty USMC WASIER eometed : 6. Only make fixing pipe circular hole clean edged and notch-free UESER WASHER by using sharp hollow punch, hole saw or sharp driller or other sharp cutter that makes perfect circular hole. Scoring or @ yo ie ora neta tecteeselties ineeetistatithelo les x St 7. Only position and make water outlet within the flat comer or base portion. - 7 et 8, DO NOT PLACED THE TANK NEARAHEATER, ELECTRICAL fe al LIGHT BULB OR OTHER SOURCE OF HEAT. A, 9, When cascading tank is necessary only links the tanks as, Va diagram (9) (9) TANKA TANKE 10. Always use the right size lid as recommended. 1 X TOP VIEW Warranty Terms & Conditions : ()Byears (outdoor) andlor 10 years (indoor) warranty coversMui Tank MS 1225 : PART 2 : 2006 / JIS A4110 : 1988 for cold water storage only unless otherwise specified. (i) We shall not be held responsible for any defects or damages to the tank if above installation instructions are not adhered to. (ii) Ourliabiity is strictly limited to replacing the water tanks. The company will nat be responsible for any consequence ‘or losses resulting from the tanks. (iv) Our Mui Tank are used for cold water storing on elevated even as clause No. 3. INSTALLATION INSTRUCTION Closed Top Series 1 Mui tanks should lifted/ unloaded using crance or similar by using ropes or nylons slings to lifting ugs provided NOT lifting at side fittings. Mui Tanks should strickly lifted when empty of liquid/ water. Mui Tanks should place obn an elevated even surface, such as concrete platform at least 10 inch (250mm) height from ground level, free of debris or stones. After Mui Tanks is positioned should all piping and jointing supported with steel/ concrete footing After lf! loading using crane to the lorry/ low loarder tanks must be safeguarded by wrapping slings around the body of tanks, Strictly NOT on pipes fitting. Mui Tanks surrounding area should have fencing to prohibit unauthorised person's to prevent incidents eg Strike on tanks with hammer, spanner or sharp object. Mui Tanks should not place near heater, electric light- buld or other source of heat. Warranty Terms & Conditions : @ i) iii) (iv) 8 years (putdoor ) and /or 10 years (indoor) warranty covers Mui Tank JIS A4110:1989 for cold water storage only unless otherwise specified. We shall not be held responsible for any defects or damages to the tank if above installation instructions are not adhered to. ‘Our liability is strictly limited to replacing the water tanks. The company will not be responsible for any consequence losses resulting from the tanks. (Our Mui Tanks are used for cold water storing on elevated even surface as clause No. 3, MUI FATT Pipes Support 6) ©. am Wit ay acalice ey

You might also like