The relay type NA10 can be used in radial networks as feeder or power transformer protection.
In solidly grounded systems the residual overcurrent protection can be used on feeders of any length, while in
ungrounded or Petersen coil and/or resistance grounded systems, the residual overcurrent protection can be
used on feeders of small length in order to avoid unwanted trippings due to the capacitive current contribution
of the feeder on external ground fault.
The relay complies with CEI 0-16 requirements.
52
74TCS
50/51 74CT
- Protective & control functions
— Construction
According to the hardware configurations, the NA10 protection
relay can be shipped in various case styles depending on the
required mounting options (flush, projecting mounting, rack or
with separate operator panel).
— Output relays
Six output relays are available (two changeover, three make and
one break contacts); each relay may be individually programmed
as normal state (normally energized, de-energized or pulse) and
reset mode (manual or automatic).
A programmable timer is provided for each relay (minimum pulse
width). The user may program the function of each relay in ac-
cordance with a matrix (tripping matrix) structure. — Communication
Multiple communication interfaces are implemented:
— Modular design • One RS232 local communication front-end interface for com-
In order to extend I/O capability, the hardware can be custom- munication with ThySetter setup software
ized through external auxiliary modules: • Two back-end interfaces for communication with remote mon-
• MRI - Output relays and LEDs itoring and control systems by:
• MID16 - Binary inputs - RS485 port - ModBus® RTU, IEC 60870-5-103 or DNP3 protocol,
• MCI - 4...20 mA converter - Ethernet port (RJ45 or optical fiber) - ModBus/TCP protocol.
• MPT - Pt100 probe inputs.
— Programming and settings
All relay programming and adjustment operations may be per-
formed through MMI (Keyboard and display) or using a Personal
Computer with the aid of the ThySetter software.
The same PC setup software is required to set, monitor and con-
figure all Pro_N devices.
Full access to the available data is provided:
• Read status and measures.
• Read/edit settings (on-line or off-line edit).
Two session level (User or Administrator) with password for sen-
sible data access are provided.
ThySetter
— Blocking input/outputs
One output blocking circuit and one input blocking circuit are
provided.
The output blocking circuits of one or several Pro_N relays,
shunted together, must be connected to the input blocking cir-
cuit of the protection relay, which is installed upwards in the
electric plant. The output circuit works as a simple contact,
whose condition is detected by the input circuit of the upwards
protection relay.
For long distances, when high insulation and high EMC immunity
is essential, a suitable pilot wire to fiber optic converter (BFO)
is available.
— Firmware updating
The use of flash memory units allows on-site firmware updating.
TRIP I>>
BLIN1
BLOUT1
BLIN1
TRIP I>> Block2 IPh TRIP I>>
BLIN1
BLOUT1
TRIP I>>
Any device
Logic selectivity
Oscillography (DFR)
L1
L2
L3
NA10
P1 C1
S1
IL1
S2 C2
P2
C3
CURRENT INPUTS
IL2
C4
C5
IL3
C6
P1 C7
S1
IE
S2 C8
P2
F1
F2
A19
IN1 F3
RS485
A20 F4
B-
A21 Supervision
IN2 A+ F5
A22 unit
BINARY INPUTS
B1
IN3
B2
B3
IN4
ETHERNET
B4
B5 D1
IN5
HUB
B6
54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28
THYBUS
A1 ≅ E1
UAUX
A2
OUTPUT INPUT
RUN
BUS
ON
1
2
3
4
5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
BLOCK OUT
BLOCK IN
BLOUT-
A17 A15
BLOUT+
A18 A16
FRONT PANEL
RS232
D1 D1
A1 A1
A2 A2
C1 C2 C1 C2
ø 4.5 A3
A4 RX
F1
F2
A3
A4 RX
F1
F2
A5 F3 A5 F3
A6 TX F4 A6 TX F4
A7 F5 A7 F5
A8 C3 C4 A8 C3 C4
A9 B1 A9 B1
A10 B2 A10 B2
177
171
149
200
168
A11 B3 A11 B3
A12 B4 A12 B4
ON 1 2 3 4 5 START ON 1 2 3 4 5 START
A13 B5 A13 B5
80
A17 A17
A18 A18
A19 A19
A20 C7 C8 A20 C7 C8
A21 A21
A22 A22
31
E1 E1
20
FLUSH MOUNTING PROJECTING MOUNTING FLUSH MOUNTING PROJECTING MOUNTING
(Separate operator panel)
SIDE VIEW
212.5 275
25 15
205 30 5 30 ø 4.5
170
161
101.6
154
Headquarter: 20139 Milano - Piazza Mistral, 7 - Tel. +39 02 574 957 01 ra - Fax +39 02 574 037 63
Factory: 35127 Padova - Z.I. Sud - Via dell’Artigianato, 48 - Tel. +39 049 894 770 1 ra - Fax +39 049 870 139 0