G 2.

0 DOHC > Automatic Transaxle System > Valve Body System > Solenoid valve > Description and Operation (F4A51-3)

DESCRIPTION
Actuators
Solenoid Valve for Pressure Control
- Sensor type: Normal open 3-way
- Operating temperature : -30°C∼ 130°C(-22°F~266°F)
- Frequency:
LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above -20°C(-4°F))
DCC: 30.64Hz
- Internal resistance:
3.0 ± 0.5 Ω (LR, 2ND, UD, OD, TCC)
4.35 ± 0.5 Ω (VFS)
- Surge voltage: 56 V (Except VFS)
(LR, 2ND, UD, OD, DCC)

Location

Solenoid Valves Schedule


Position Solenoid valves
Operation LR 2ND UD OD * DCC
1st gear OFF ON OFF ON OFF
2nd gear ON OFF OFF ON OFF
3rd gear ON ON OFF OFF ON
4th gear ON OFF ON OFF ON
Reverse OFF ON ON ON OFF
N, P (STD. mode) OFF ON ON ON OFF
N, P (Hold mode) ON OFF ON ON OFF

*: Reference value.
(DCC solenoid valve will be ON when the operating condition is satisfied)