Product Status Report
13/10/2023 5:19 PM
EMCP 4.2
Parameter Value
ECM Part Number 4509606-00
ECM Serial Number 0767E569TX
Software Group Part Number 4784981-00
Software Group Release Date FEB2015
Software Group Description EMCP 4.2 English, v4.4.1 PROD, 16 February
2015
Logged Diagnostic Codes [SHM: 27275 RTC: 13/10/2023 4:23:34 PM] - EMCP 4.2
Code Description Occ. SHM First SHM Last RTC First RTC Last
639-11 J1939 Network #1 : Other 2 23378:01:3 23378:01:3 21/11/2022 21/11/2022
Failure Mode 0 0 11:31:13 11:37:25
AM AM
714- 6 Auxiliary I/O #14 : Current 22 9649:45:14 22294:08:1 10/06/2018 05/07/2022
Above Normal 1 3:11:46 AM 9:53:57 AM
713- 6 Auxiliary I/O #13 : Current 48 9649:45:14 22244:18:2 10/06/2018 19/06/2022
Above Normal 3 3:11:47 AM 11:09:20
PM
190- 5 Engine Speed : Current 1 20173:07:3 20173:07:3 08/11/2021 08/11/2021
Below Normal 0 0 5:09:45 PM 5:09:45 PM
1231-11 J1939 Network #2 : Other 1 18737:13:3 18737:13:3 06/08/2021 06/08/2021
Failure Mode 0 0 6:03:51 PM 6:03:51 PM
677-14 Engine Starter Motor 1 0:00:03 0:00:03 24/07/2017 24/07/2017
Relay : Special Instruction 1:59:55 PM 1:59:55 PM
Logged Event Codes [SHM: 27275 RTC: 13/10/2023 4:23:34 PM] - EMCP 4.2
Code Description Occ. SHM First SHM Last RTC First RTC Last
2440-15 Generator Average Line- 99 6853:28:12 26961:35:5 25/07/2017 30/09/2023
Line AC RMS Voltage : 6 1:09:45 AM 12:09:40
High - least severe (1) AM
167-17 Charging System 99 0:00:03 25738:52:2 24/07/2017 01/08/2023
Potential : Low - least 8 2:02:05 PM 10:10:47
severe (1) AM
970-31 Engine Auxiliary Engine 64 8389:10:30 24584:07:1 27/01/2018 16/03/2023
Shutdown Switch 7 2:05:36 PM 3:32:48 PM
110-17 Engine Coolant 99 8389:10:30 23803:34:0 27/01/2018 06/02/2023
Temperature : Low - least 3 2:03:40 PM 3:44:58 AM
severe (1)
168-17 Battery Potential / Power 82 9654:03:49 23404:43:3 11/06/2018 06/12/2022
Input #1 : Low - least 0 8:13:03 AM 8:45:31 AM
severe (1)
2456-15 Generator Total Reactive 12 11842:43:5 23400:54:2 24/03/2019 26/11/2022
Power : High - least 9 0 6:27:09 PM 10:33:22
severe (1) AM
2436-15 Generator Average AC 12 20164:11:4 23378:16:2 06/11/2021 22/11/2022
Frequency : High - least 4 7 1:24:26 PM 3:58:06 PM
severe (1)
2436-17 Generator Average AC 5 11713:03:4 22608:54:0 05/03/2019 25/08/2022
Frequency : Low - least 2 3 9:05:19 PM 2:46:57 PM
severe (1)
2448-15 Generator Average AC 3 0:00:03 21694:02:3 24/07/2017 23/04/2022
RMS Current : High - 8 2:02:04 PM 8:27:20 AM
least severe (1)
100-17 Engine Oil Pressure : Low 99 20883:00:3 20884:43:5 31/01/2022 31/01/2022
- least severe (1) 0 6 4:49:04 PM 6:32:29 PM
168- 0 Battery Potential / Power 9 11827:44:5 11843:10:1 20/03/2019 30/03/2019
Input #1 : High - most 3 7 7:31:27 AM 6:04:40 PM
severe (3)
168-15 Battery Potential / Power 11 11785:45:2 11843:09:4 17/03/2019 30/03/2019
Input #1 : High - least 0 4 1:28:27 AM 6:04:07 PM
severe (1)
Active Diagnostic Codes [SHM: 27275 RTC: 13/10/2023 4:23:34 PM] - EMCP 4.2
Code Description Occ.
No Active
Diagnostic
Codes
Active Event Codes [SHM: 27275 RTC: 13/10/2023 4:23:35 PM] - EMCP 4.2
Code Description Occ.
4004-31 Generator Breaker Closed 1
4007-31 Generator Control not in Automatic 0
Logged Diagnostic Codes [Diagnostic Clock = 26501 hours] - C32 Genset (PRH03216)
Code Description Occ. First Last
No Logged
Diagnostic
Codes
Logged Event Codes [Diagnostic Clock = 26501 hours] - C32 Genset (PRH03216)
Code Description Occ. First Last
No Logged
Event Codes