A B C D E
1 ELECTRICAL NOTES :
C1
PB1
C2
S2
2 PB1
S2
S1
C1
PB1
3 S2
C1 C
PB1
EF
WL
4 C1
PB1 S2 EF
C
C1
S2 PB1
C2
S1 S3
5 PB-2 PB-1 PB1
C2
PB1
S3
6 S3
WL
WL WL
WL
E LIGHTING & WIRING LAY-OUT
PROJECT TITLE : SHEET CONTENTS : SHEET NO.
PROPOSED MODERN BUNGALOW HOUSE ELECTRICAL DRAWING
E
CONSTRUCTION DRAWING OWNER : * LIGHTING & WIRING LAY-OUT
SALEM RESIDENCE * GENERAL NOTES & SYMBOL 1-3
A B C D E
1 C7
ELECTRICAL NOTES :
PB2 WM
ACU
2 C.O
C.O RC
C.O
C6
C3 PB1
PB1 REF
C.O
C.O
3
C
C.O
C5
PB1 WL
4
FIRE WALL
EF
C.O C4
PB1
C3
PB1 C.O
C.O C.O
5 C.O
PB-2 PB-1
C.O
C8
C9 C5
PB2
PB2 PB1
C.O C.O C.O ACU
ACU
R O A D
E POWER & CONVIENCE OUTLET LAY-OUT
PROJECT TITLE : SHEET CONTENTS : SHEET NO.
PROPOSED MODERN BUNGALOW HOUSE ELECTRICAL DRAWING
E
CONSTRUCTION DRAWING OWNER : * POWER & CONVIENCE LAY-OUT
SALEM RESIDENCE * GENERAL NOTES & SYMBOL 2-3
BUILDING FLOOR AREA= 89.0 SQ.M
89.0 SQ.M X 24 WATTS/SQ.M = 2,136 WATTS
SMALL APPLIANCES = 3,000 WATTS
LOAD CALCULATION :
TOTAL LOAD + 25% LARGEST MOTOR
IT =
FIRST 3000 WATTS AT 100% DF = 3,000 WATTS 220 V I T = (92.08xDemand Factor=80%) + (Max Motor loadx25%)
REMAINDERS AT 2,304 WATTS @ 35% = 1,400 WATTS I T = (92.08x0.8) + (6.8x0.25)
13,503 + (0.25 x 1,500)
1 COOKING RANGE ( DF= 100%) = 3,500 WATTS IT =
= 73.66+1.7
220 V
1 WASHING MACHINE ( DF=100%) = 1,500 WATTS I T = 75.36 Amps.
2 0.75 HP ACU (3 SETS) = 3,357 WATTS = 63.082 AMP. use: 80AT, 2p, CB
1 1 HP REFRIGERATOR = 746 WATTS
NOTE: SINCE TOTAL LOAD EXCEEDS 10,000 WATTS
SERVICE ENTRANCE WIRES :
TOTAL = 13,503 WATTS USE 100AT MAIN DISCONNECTING BREAKER
SCHEDULE OF LOADS PB-1
PROTECTION
CKT.# DESCRIPTION PHASE VOLTS RATING CONDUCTOR SIZE CONDUIT
1 LIGHTING OUTLET 1Ø 220 20 AT/2P 2- 2.5 mm2 / 14 AWG PVC-3/4 DIAMETER
2 LIGHTING OUTLET 1Ø 220 20 AT/2P 2- 2.5 mm2 / 14 AWG PVC-3/4 DIAMETER
3 CONVENIENCE OUTLET 1Ø 220 20 AT/2P 2- 4.0 mm2 / 12 AWG PVC-3/4 DIAMETER
4 CONVENIENCE OUTLET 1Ø 220 20 AT/2P 2- 4.0 mm2 / 12 AWG PVC-3/4 DIAMETER
5 COOKING RANGE OUTLET 1Ø 220 30 AT/2P 2- 6.0 mm2 / 10 AWG PVC-3/4 DIAMETER
WASHING MACHINE &
6 1Ø 220 30 AT/2P 2- 6.0 mm2 / 10 AWG PVC-3/4 DIAMETER
REFRIGERATOR OUTLET
SCHEDULE OF LOADS PB-2
PROTECTION
CKT.# DESCRIPTION PHASE VOLTS RATING CONDUCTOR SIZE CONDUIT
7 AIR CONDITION UNIT 1Ø 220 20 AT/2P 2- 4.0 mm2 / 12 AWG PVC-3/4 DIAMETER
8 AIR CONDITION UNIT 1Ø 220 20 AT/2P 2- 4.0 mm2 / 12 AWG PVC-3/4 DIAMETER
9 AIR CONDITION UNIT 1Ø 220 20 AT/2P 2- 4.0 mm2 / 12 AWG PVC-3/4 DIAMETER PANEL
10 SPARE OUTLET 1Ø 220 20 AT/2P 2- 4.0 mm2 / 12 AWG PVC-3/4 DIAMETER
11 SPARE OUTLET 1Ø 220 20 AT/2P 2- 2.5 mm2 / 14 AWG PVC-3/4 DIAMETER BOARD
12 SPARE OUTLET 1Ø 220 20 AT/2P 2- 2.5 mm2 / 14 AWG PVC-3/4 DIAMETER
METER
2-30 SQ. MM. THW
3AWG
M
2-16 SQ. MM. THW
6AWG
MAIN 100 AT MAIN 60 AT
L.O. L.O. ACU ACU
C1 2- 2.5 mm2 / 14 AWG
C.O.
15 AT 15 AT
C.O.
2-2.5 mm2 / 14 AWG C2 C7 2- 4.0 mm2 / 12 AWG
ACU
20 AT 20 AT
SPARE
2- 4.0 mm2 / 12 AWG C8
E ELECTRICAL SERVICE DROP LAY-OUT
C3 2- 4.0 mm2 / 12 AWG 20 AT 20 AT 2- 4.0 mm2 / 12 AWG C4 C9 2- 4.0 mm2 / 12 AWG 20 AT 20 AT 2- 4.0 mm2 / 12 AWG C10
R.C. W.M / R.A SPARE SPARE
C5 2- 6.0 mm2 / 10 AWG 30 AT 30 AT 2- 6.0 mm2 / 10 AWG C6 C11 2- 2.5 mm2 / 14 AWG 15 AT 15 AT 2- 2.5 mm2 / 14 AWG C12
BREAKER PANEL LAY-OUT & ANALYSIS CONSTRUCTION DRAWING
E
PROJECT TITLE : SHEET CONTENTS : SHEET NO.
PROPOSED MODERN BUNGALOW HOUSE ELECTRICAL DRAWING
OWNER : * ELECTRICAL DESIGN ANALYSIS
E
SALEM RESIDENCE * DROP SERVICE LAY-OUT 3-3