SCHEDULE OF LOAD:

CONDUCTOR LEGEND
CIRCUIT NO. DESCRIPTION LO's CO's POLE VOLT OCPD A %Vd KAIC
(mm2) CU WIRE

1 LIGHTING FIXTURES 9 2 220 15 1.35 3.5mm2 tHw cu 0.036 5.0


S1 SINGLE GANG SWITCH
2 GUR'S 7 2 220 30 4.91 5.5mm2 tHw cu 0.111 5.0 S2 DOUBLE GANG SWITCH
S3 THREE WAY SWITCH
3 SPARE
CEILING LIGHT OUTLET
TOTAL 9 7 2 220 40 6.2600 8.0mm2 tHw cu 0.179 10.0 CONVIENCE OUTLET
RANGE OUTLET

SHORT CIRCUIT CURRENT CALCULATION SPECIAL PURPOSE OUTLET


SINGLE - LINE DIAGRAM
8.2000 SWITCH LINE
LINE to LINE FAULT : POWER LINE
1.9000 3.2000 3.1000 Assume: Infinite Capacity and Neglecting all other impedances
TO SUPPLY, 1PHASE, 230V PANEL BOARD
Point of connection at transformer supply from aneco.
M WATT HOUR METER
IscL = 5.0 x 1000 x /400/1.7 x 101
2-8.0mm2 tHw cu wire

KILOWATT-HOUR METER
IscL - L = 22.73 A x 100 /%IZ CONDUCTOR AND OCPD CALCULATION:
M = 1,894 X 100/(1.22%X + 0.68% R) IFL = 150% ( Continous Load ) + Other Load
= 1,894 A IFL = 125 (4.5) + 1.35 + 4.90 ( 0.80)
Calculating the factor (If) for motor contribution IFL = 10.90 A
3.6500

If = 2 x 25 x 1,894 / 2,425 x 220 Use 2-8.0mm2 thw cu. wire in 15mmdia. pipe
= 1/1.18 = 0.85 1-40 AT / 60 AF, 2p, 220v ACB
= (1,894 x 0.85) x 1.5
40 AT, 2P 10 AT
Isc = 2,407 A VOLTAGE DROP CALCULATION:
S2 S2 S2 V = 2 x L x I x K / cm
S2 = 2 x 25' x 10.9 x 12.9 / 16,510 = 0.39v
%Vd = 0.179 (For conductor no. 8.0mm2 cu wire)
The line conductor shall be the same size with the neutral conductor
S3 15 AT 30 AT and the Circuit Breaker should be rated not less than 10 KAIC for V1 = 2 x L x I x K / cm
C1 C2 Main Breaker with branches at 5 KAIC. = 2 x 15 x 1.35 x 12.9 / 6,530 = 0.08 v
%Vd1 = 0.036 (For conductor no. 3.5mm2 cu wire)
9.3000

SPARE C
3
20 AT SPECIFICATION: %Vd2 = 0.11 (For conductor no. 3.5mm2 cu wire)
3.6500

1. ALL ELECTRICAL INSTALLATIONS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF THE LATEST EDITION OF THE
G PHILIPPINE ELECTRICAL CODE APPLICABLE ORDINANCES, RULES AND REGULATIONS OF TRHE LOCAL GOVERMENT AND WITH THE
S2 REQUIREMENT OF THE LOCAL POWER COMPANY.
2. ALL WIRING SHALL BE INSTALLED ON STANDARD R.S CONDUIT RUN EMBEDED IN CONCRETE AND HOLLOW BLOCK STRUCTURE,
C2 COLUMNS, WALLS, PARTITIONS AND / OR RUN CONCEALLED BETWEEN DOUBLE WALL WOODEN PARTITIONS, AND INSIDE THE CEILING
S1 S1
WHERE THE USE OF CONCEALED CONDUCT WIRING IS IMPRACTICABLE SURFACE METAL MOULDING MAYBE USED.

C1 3. UNLESS OTHERWISE SPECIFIED THE MINIMUM SIZE OF R. S. CONDUIT AND WIRE SHALL BE 15 mm IN DIAMETER AND 3 - 5 mm2 TW
2.0000

COPPER WIRE RESPECTIVELY.


4. WHERE REQUIRED AND NECESSARY PULL BOXES OR JUNCTION BOXES IN PROPER SIZES SHALL BE INSTALLED AT CONVIENCE AND IN
P-6 BRGY. BADING, BUTUAN CITY
CONSPICOUOS LOCATIONS ALTHOUGH SUCH BOXEZ ARE NOT SHOWN ON THE PLAN NOR MENTIONED IN THE SPECIFICATION.
5. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF DULLY LICENSED ELECTRICAL ENGINEER.
2.1500

SLAUGHTER ROAD
HOUSE

ROAD

THIS SITE
ROAD

ELECTRICAL PLAN LOCATION PLAN


SCALE: 1: 100 MTS
SCALE 1: 200 MTS

AGENCY: SCHOOL: PROJECT TITLE: PLATE NO.: SUBMITTED BY: SUBMITTED TO: PAGE CONTENT: PAGE NO:

01
01
SAINT JOSEPH INSTITUTE PROPOSED RESIDENTIAL BUILDING SUSARNO, CLINT A. ENGR. VITO MALATAG
OF TECHNOLOGY

ADDRESS:P-6 BADING, BUTUAN CITY, AND


BSCE-2 BSCE-2
10