DC GENERATOR WIRING DIAGRAM

A1
SIEB 5KW & 10KW MAGNET SYSTEMS
A2 4295 AUTOMATIC DROP CONTROLLER
S2
SIZE 1 OR 2, 12v OR 24v for MOMENTARY SWITCH

S1
CONTROLLER
F2
CONTROLLER CABINET DOOR
CABINET
F1

SHOWN FOR CLOCKWISE ROTATION


(FACING SHAFT) RESISTOR BANK
FOR COUNTERCLOCKWISE ROTATION FIELD CONTROL
INTERCHANGE LEADS A1 AND A2 RESISTOR
RESISTOR BANK

10/3 CABLE (5KW) VOLTMETER

GN
8/3 CABLE (10KW)

SAFETY BK M2 L+
LIFT DROP
DISCONNECT + -
L- M1
W

TERMINAL BLOCK

6
5
IR
4
3

BK
BK

W
8/2 CABLE
8/2 CABLE
W

MOMENTARY
IMPULSE

SWITCH PILOT
RELAY

RELAY
OPEN
IR

REV. 072308
LIGHT
GRD
PL S2 S1 + - 4 5 6
F
M

GN
W
BK
SEE NOTE 2
14/3 CABLE

SWITCH RELAY
NOTES:
1. SAFETY FIRST! DISCONNECT ALL POWER SOURCES WHEN
MAGNET WIRING THE EQUIPMENT.

2. CUSTOMER SUPPLIED POWER SOURCE. USE KEYED POWER.


DO NOT TAKE DIRECTLY FROM BATTERY. THE CONTROLLER
M/L NUMBER INDICATES IF THE CONTROLLER IS 12 VOLT OR 24
VOLT. NEVER SUPPLY 24 VOLT POWER TO A 12 VOLT
SIEB SALES & ENGR., INC. CONTROLLER!
10001 EXPRESS DR.
HIGHLAND, IN 46322 CALL 219-924-3616
www.siebsales.com FOR ASSISTANCE