You are on page 1of 3

LOAD SCHEDULES AND COMPUTATIONS 3 WIRE

SERVICE 3 WIRE
SERVICE
ENTRANCE ENTRANCE
GUY WIRE
PANEL NO. LOAD DESCRIPTION KW V AMP / CIRCUIT WIRE SIZES
LPP 1 MAIN 230
85 AT / 2P
2
LPP 2 12 LIGHTING OUTLET 2.16 230 9.130 BEDROOM 2 BEDROOM 1 3 4
CATV
LPP 3 6 LIGHTING OUTLET 1.08 230 4.695 PROVISION
5 6
13 LIGHTING OUTLET
LPP 4 2.34 230 1.017
KILOWATT KITCHEN 7 8
HOUR METER T&B 2 CAR GARAGE
LPP 5 8 LIGHTING OUTLET 1.44 230 6.26 SAFETY 9 10
SWITCH
LPP 6 1.80 230 7.82
10 LIGHTING OUTLET CABLE WIRE IN 20 MM 2-22 MM^2 THN WIRE X 8.0 MM^2 11 12
DIAMETER FLEXIBLE THN WIRE IN 50 MM DIAMETER
LPP 7
11 LIGHTING OUTLET
1.98 230 8.60 CONDUIT CONDUIT PIPE 14
13
LPP 8 3 LIGHTING OUTLET 0.54 230 2.35
LPP 15 CONVENIENCE 230
9 OUTLET 2.70 1.17 GROUND
REFRIGIRATOR
LPP
10 1.50 230
6.52 RISER DIAGRAM SINGLE LINE DIAGRAM
NOT TO SCALE
NOT TO SCALE
ACU (0.75 HP) 230
LPP 11 0.56 2.43
GENERAL NOTES:
LPP ACU (0.5 HP) 230
12 1.12 4.87
LPP 1. ALL ELECTRICAL WORKS SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST EDITION OF THE
230
13 ACU (0.5 HP) 0.37 1.61 PHILIPPINE ELECTRICAL CODE, THE LAWS AND ORDINANCES OF THE LOCAL CODE ENFORCING AUTHORITIES
AND THE REQUIREMENTS OF THE LOCAL POWER.
LPP 230
14 RANGE 3.00 1.30
TOTAL = 57.772 2. ALL MATERIALS TO BE USED SHALL BE NEW AND INSTALLED IN APPLICATION FOR WHICH THEY ARE
(57.77 x 0.8) + 9.13 x 0.25 = 13.84 AMPACITY: 85 AMPERES INTENDED.
WIRE SIZE: 2-22 MM^2 THN WIRE & 8.0 MM
-THN WIRE IN 50 MM DIA. CONDUIT 3. THE MINIMUM SIZE OF THE WIRE SHALL BE 2.0 SQ. MM. AND SHALL BE OF THW AND TW TYPE OF INSULATION
MINIMUM SIZE OF CONDUIT SHALL BE 20 MM. IN DIAMETER CONDUIT PIPE.
- LIGHTING OUTLET
- WIRE & CONDUIT CONCEALED IN CEILING, WALL & FLOOR 4. ALL WIRES AND BRANCH CIRCUIT PROTECTIONS SHALL FOLLOW THE LOAD SCHEDULE AND PANEL
- PIN LIGHT LIGHTING OUTLET ARRANGEMENTS.
- SWITCH LINE
- T-5 DOWNLIGHT / UPLIGHT OUTLET
- TELEPHONE RACEWAY CONDUIT
Sa - SINGLE GANG SWITCH 5. FOR SWITCH AND RECEPTACLE BOXES WITH MORE THAN FOR FOUR WIRES ENTERING THEM, USE 100 MM. x
Sab - TWO GANG SWITCH - CATV RACEWAY CONDUIT 100 MM. BOX BY MEANS.
Sabc INDICATES
- THREE GANG SWITCH (LETTER
LIGHTING OUTLET)
S3a - THREE WAY SWITCH - LIGHTING AND POWER PANEL BOARD
- DUPLEX CONVENIENCE OUTLET
6. EXCEPT OR OTHERWISE NOTED, MOUNTING HEIGHTS FOR OUTLET AND DEVICES SHALL BE:
- WEATHER PROOF CONVENIENCE OUTLET 12 - CIRCUIT HOME RUN (NUMBER INDICATES CIRCUIT AND
SWITCH - 1.35 MTS ABOVE FINISH FLOOR LINE (FFL) AND 0.51 M. FROM DOORLAMB AND WALL EDGE.
CONVENIENCE OUTLET - 0.30 M ABOVE FINISHED FLOOR LINE.
WP LPP
PANEL BOARD)
ACU
- AIR CONDITIONING UNIT OUTLET
- RANGE OUTLET - SERVICE ENTRANCE PANEL BOARD - 1:50 MTS ABOVE FINISHED FLOOR LINE.
R
REF - REFRIGERATOR OUTLET
- KILOWATT HOUR METER
TV - CATV OUTLET M 7. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF DULY LICENSED ELECTRICAL
- TELEPHONE OUTLET - GROUND ENGINEER OR MASTER ELECTRICIAN.
LANAI
STORAGE
LPP
2

T&B
ROOM
T&B MASTER
3 P
LP

T&B DRESSING
KITCHEN ROOM BEDROOM
DINING AREA

5
LP
P
2 CAR GARAGE ANTE

8 P
LP

LP 7
P
LAUNDRY AREA
ROOM
HALLWAY

LP 6
P
LP
P
4
LIVING AREA
BEDROOM 1 BEDROOM 2
PATIO BALCONY
GROUND FLOOR LIGHTING LAYOUT SECOND FLOOR LIGHTING LAYOUT
SCALE 1:100 MTS SCALE 1:100 MTS
LPP LPP
LANAI
14 11
T&B STORAGE
ROOM
T&B T&B
KITCHEN DRESSING MASTER
ROOM BEDROOM
DINING AREA LP
9 10 P
LP
P
2 CAR GARAGE
LAUNDRY ANTE
2-
ROOM 2
WI 2MM AREA
PIP RE I TH
E N W
50M WIR
M
DIA E 1-3
. CO .0 TH HALLWAY
ND U
UIT
LIVING AREA 13
LP 12 P
P LP
BEDROOM 1 BEDROOM 2
PATIO
3 WIRE SERVICE
BALCONY
ENTRANCE
GROUND FLOOR POWER LAYOUT SECOND FLOOR POWER LAYOUT
SCALE 1:100 MTS SCALE 1:100 MTS

You might also like