You are on page 1of 13

1 2 3 4 5 6 7 8 9 10

SHEET DESCRIPTION
MAIN POWER SUPPLY
1 INDEX A
2 POWER CIRCUIT MAIN MOTOR VOLTAGE : 380-460V
3 POWER CIRCUIT CP MOTOR
FREQ : 50/60Hz 3 PH
4 SUPPLY CONTROL CIRCUIT
5 CONTROL CIRCUIT FILTER DATA
6 CONTROL CIRCUIT CONVERTER
7 CONTROLLER PUMP Z1
B
8 GPRS MODULE
18.5KW 50A
9 INPUT CONNECTIONS 2X27
10 INPUT CONNECTIONS 2X28 26KW 65A
11 POTENTIAL FREE CONTACT
37KW 100A
12 LEGEND
13 NOTES
FUSE SETTING
C

F1 2A F4/F5/F6 1.25A STANDARD PRODUCT

F1 2A F4/F5/F6 1.6A/2.0A/2.0A WEATHER RESISTANT VARIANT

RECOMMENDED F35 / F36 / F37 MAX FUSE SIZE [A]


RATING CAPACITY

PUMP VOLTAGE [V] IEC aR UL/CSA CLASS T 160 VA STANDARD PRODUCT


T1
D
380 80 80
T1 232 VA WEATHER RESISTANT VARIANT
37KW 400 80 80
SETTINGS
460 70 70
Q15 2.2 A
380 63 60

26KW 400 63 60 E
MOTOR DATA

460 50 50
M1 18.5 KW 25HP SF:1.15 38A
380 45 45
M1 26 KW 35HP SF:1.15 52A
18.5KW 400 45 45
M1 37 KW 50HP SF:1.15 73A
460 45 45
F
M2 0.75KW 1HP SF:1 1.7A
copied, used for manufacturing or communicated to any other person or company.
This document is our property and shall not without our permission be altered,

All materials supplied are in compliance with the requirements of the List of Prohibited Substance
Confidentiality Class
Name L254 VSD TOTAL RECOVERY VACUUM 1102 K/
02 Material Not Applicable Confidential

Note 1: Treatment 15 ACDE


- Drawing Updated for Total Recovery Scale 1:1 Family Not Applicable A3 Compare Drawing owner
Drawn by INEPRA Blank nr. Not Applicable Replaces CQV G
C Version Drwg Designation Sheet 01 (13)
01 See Note 1 (EC 13896) 17-05-2021 ER Not Applicable Not Applicable Blank wt. N/A Kg Fini wt. 0 Kg
IN
STATUS 01
Note
Posi-
tion
Modified from Date Intr./Appd. Parent 3D Model Ed.Version 3D Preliminary
Des checked. Prod checked. Approved. Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10
POWER CIRCUIT MAIN MOTOR
L1 AWG 2
L2
L3 A

L1 L2 L3

Z1
L1' L2' L3'

AWG 14
1X3 1L1 B
PE 4.3
1L2 4.3

F35F36 F37 AWG 2


1 1 1

AWG 14
1L1 3.1
2 2 2
Item Only valid for
T0 1L2 3.1
T0 200,230V
500,575V 1L3 3.1 C
F35-37 200,230,575V

1X0'
[E] L1 L2 L3

[F]

1 3 5
F0'
[A] U1 L1 L2 L3 PE
2 4 6
6.1

S0'
U V W

W1
V1
U1
AWG 2

Z2 F
copied, used for manufacturing or communicated to any other person or company.
This document is our property and shall not without our permission be altered,

L1
U1 V1 W1 PE
[B]
L2 T1 T2 T3
L3 M
PE 3~

CUSTOMERS' INSTALLATION M1 [B]


VACUUM PUMP MOTOR
G
Designation Sheet 2 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 1 Next Page 3 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10
POWER CIRCUIT CP MOTOR

2.10 1L1 A
2.10 1L2
2.10 1L3

1 3 5
Q15
1.6 - 2.5A B
13 14 9.6
I>I>I>
2 4 6

1 3 5
K15
5.5
2 4 6
C

AWG 14

U3 L1 L2 L3 PE PE
6.1

U V W

U W PE
V
AWG 14

F
copied, used for manufacturing or communicated to any other person or company.

Z2
This document is our property and shall not without our permission be altered,

U V W PE

M
M2 3~
[B]
CENTRIFUGAL PUMP MOTOR

G
Designation Sheet 3 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 2 Next Page 4 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10

SUPPLY CONTROL CIRCUIT

2.10
1L1
2.10
1L2

1
1
C
F1(X2)

.
2
2

[D] AWG 18
26 1 F4 2 1 5.1
. 1

110V/AC
D
2 2 5.1
1X3

PE
27 AWG 18
1 F5 2 44 9.10
. 44

24V/AC
E
1 F6 2 43 9.10
. 43

T1

F
copied, used for manufacturing or communicated to any other person or company.
This document is our property and shall not without our permission be altered,

G
Designation Sheet 4 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 3 Next Page 5 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10
CONTROL CIRCUIT
1

11
S3 A
22 21 9.7
32 31 6.3
12 42 41 6.3

1X4
3

3
3 7 5
1 11
2X30 2X30 2X30 C
2X30 2X30
K02 K04 K03 K01 K06
7.3 7.3 7.3 7.3 7.3
4.7 1
2X30 2X30 2X30 2X30 2X30
4 8 6 2 12
110V/AC

4.7 2

38

39
D
5
4

6
1X4 1X4 1X4 1X4 1X4 1X4
4 5 6 3 38 39

3 X AWG 18 3 X AWG 18
BK BK
L E
Y1 A1 Y2 A1 Y3 A1 Y4 A1
K15 A1

M3
A2 A2 A2 A2
[G] [G] A2 [G] [G]
N
BK BK
2

2
2

2
2

F
1X4 1X4 1X4 1X4 1X4 1X4 1X4
copied, used for manufacturing or communicated to any other person or company.
This document is our property and shall not without our permission be altered,

2 2 2 2 2 2 2
AWG 16
1X3
7.2
PE
1 2 3.5
3 4 3.5
5 6 3.5

G
Designation Sheet 5 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 4 Next Page 6 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10
CONTROL CIRCUIT CONVERTER

CONVERTER CONTROL
111

118
9
2X30 B
117
K05
7.3 1X6 1X6
117 118
2X30 42 32
[X] [X]
10 S3 S3 CP MOTOR CONVERTER CONTROL
5.3 5.3
41 31
1X6 1X6
112 115
C

112
PSHH11
p

1X6
114

D
120

114
110

119

115

111
DI1 DI2 DI3 DI4 COM AI
U1 U3
2.6 X3:3 X3:5 X3:2 X3:6 X3:8 X3:4 X3:1 SUPPLY
X2:3
X2:1

3.5
X5:2

X5:7
X5:3

X1:1 X1:2 SUPPLY 485+ 485- GND


10V AO E
WH
GN
BN

GN
WH
BN
20
16
3 X AWG 20
R1 3 X AWG 20
F
copied, used for manufacturing or communicated to any other person or company.
This document is our property and shall not without our permission be altered,

7.9
7.9

MOTOR

G
Designation Sheet 6 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 5 Next Page 7 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10
CONTROLLER

CONTROLLER A

8.4

.
.

.
2X25 1 23456 2X24 1 23456
2X26 2X25 1 23456 2X24 1 23456
MEMORY CARD . .

.
2X30 ETHERNET RJ45 I/O OUT RJ11 B
2X20
1 NO K01

.
5.6
2 C SEPARATOR DRAIN VALVE Y3 1
E1

.
CAN2 2

.
3 NO K02 3

.
5.3 D-SUB9 4
LIQUID FILL VALVE Y1

.
4 C 5

.
6

.
5 NO K03 7

.
5.5 CUBICLE FAN 8

.
6 C 9

.
7 NO K04

.
5.4 AIR INJECTION VALVE Y2 C
8 C
.
9 NO K05 2X21 2X21
.

6.2 CONVERTER INTERLOCK


10 C
.

1 1 GN

.
11 NO K06 CAN1 2 2
.

.
3 3
WH

.
5.7 12 C ELEMENT DRAIN VALVE Y4 D-SUB9 4 4 6.4
.

.
5 5

.
6 6 BN

.
7 7

.
2X31 8 8

.
9 9

.
1 NO K07 D
.

11.5 C AUTOMATIC OPERATION


2 2X22
.

3 NO K08
.

11.5 C GENERAL WARNING BN


4 1
.

.
RS485 2

.
5 NO K09 3
.

.
D-SUB9 4 GN
11.6

.
6 C GENERAL SHUTDOWN 5 6.7
.

.
6

.
7 WH
16

.
8

.
PE 9

.
5.10 E

24V AC
DI-OUT

DI-OUT
Supply
Supply
DI04
DI02

DI03

DI06
DI05
DI08
DI07

DI09
GND

GND

GND

GND

GND

GND

GND
DI01

T04

DI10
T02

T03

T05

P02
T01

P01

V+

V+
. . . . .
.

.
2X27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2X28 1 2 3 4 5 6 7 8 9 10 11 12 13 14
SC

10.1
9.1

F
copied, used for manufacturing or communicated to any other person or company.
This document is our property and shall not without our permission be altered,

9.1,10.3

G
Designation Sheet 7 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 6 Next Page 8 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10
GPRS MODULE

9.10
9.10
A

44
43
X153 1 2

L N B
U2
1

- +
V- V+
24VDC

24
25
C

. .

.
X1 1 2 3 4 5 6 7 8 9 10
X1 1 2 3 4 5 6 7 8 9 10
. .

.
SUPPLY

MAIN
D

X2

.
2
SIM

E101 GPRS MODULE

.
3

.
4

.
DSUB15 5

.
6

.
7 E

.
8

.
9

.
10

.
11

.
12

.
13

.
14

.
15

.
ETH

F
copied, used for manufacturing or communicated to any other person or company.
This document is our property and shall not without our permission be altered,

7.5

G
Designation Sheet 8 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 7 Next Page 9 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10
INPUT CONNECTIONS 2X27

CP MOTOR PROTECTION

REMOTE START/STOP
EMERGENCY STOP
DI-SUPPLY

SUPPLY

SUPPLY
SPARE

24VAC

24VAC
GND

GND

GND

GND

DI02

DI01

DI04

DI03
P01
T01

T02

T03

V+
B
2X27 1 2 3 4 5 6 7 8 10 9 11 12 13 14 15 16
. . .
.

.
7.4
WH

WH
BN

BN
SC
7.6

W3

107
W2

44

43
31
37
7
2 X AWG 21 2 X AWG 21

4.7

1X7
107 1X5
22
WH

BN

13
WH

BN

1X7
2 43 8.5
Q15 S3
3.5 5.3 7 1 44 8.5
1 2 1 2 E
14 21

PT1000 PT1000

TT01 TT02
ELEMENT OUTLET ELEMENT INLET
TEMPERATURE TEMPERATURE F
copied, used for manufacturing or communicated to any other person or company.
This document is our property and shall not without our permission be altered,

7
7

7
4.7

G
Designation Sheet 9 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 8 Next Page 10 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10
INPUT CONNECTIONS 2X28

PRESSURE SETTING SELECTION


A

LIQUID LEVEL SWITCH


DI-SUPPLY

NOT USED

NOT USED

NOT USED

NOT USED
GND

GND

GND

DI06

DI05

DI08

DI07

DI10

DI09
B

P02
T04

T05

V+
2X28 1 2 3 4 5 6 8 7 9 10 11 12 13 14
.

.
307
7.7
1X9
307

WH

RD
BK
C

108
SC
W10
BK
7.6

W2 1X7
3 X AWG 20 LS-01 108
BK
1X7
300
D
BN BU

BK BU

50
RD

BK
WH

E
1X9 1X3
1 2 3 300 PE

PT01
300

300

300
PRESSURE SENSOR F
copied, used for manufacturing or communicated to any other person or company.

VACUUM
This document is our property and shall not without our permission be altered,

LS-01
LIQUID
LEVEL
SWITCH

G
Designation Sheet 10 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 9 Next Page 11 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10
POTENTIAL FREE CONTACT

POTENTIAL FREE CONTACTS

B
1X7 1X7 1X7
101 103 105

103

105
101
AWG 18 AWG 18 AWG 18

1 3 5
C
2X31 2X31 2X31

K07 K08 K09


7.3 7.3 7.3

2X31 2X31 2X30


2 4 6

AWG 18 AWG 18 AWG 18


D

104
102

106
1X7 1X7 1X7
102 104 106

GENERAL WARNING
AUTOMATIC OPERATION

GENERAL SHUTDOWN
E

F
copied, used for manufacturing or communicated to any other person or company.
This document is our property and shall not without our permission be altered,

G
Designation Sheet 11 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 10 Next Page 12 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10

LOCATION TAGNAME SH DESCRIPTION FUNCTION LOCATION TAGNAME SH DESCRIPTION FUNCTION


A
CUSTOMER F0' 2 MAIN PROTECTION CUSTOMER INSTALLATION CONTROL PANEL U1 6 FREQUENCY CONVERTER MAIN MOTOR
CONTROL PANEL F35 2 FUSES CONVERTER PROTECTION CONTROL PANEL U3 6 FREQUENCY CONVERTER CENTRIFUGAL PUMP
CONTROL PANEL F36 2 FUSES CONVERTER PROTECTION CONTROL PANEL 2X21 7 CONNECTOR CAN1 COMMUNICATION
CONTROL PANEL F37 2 FUSES CONVERTER PROTECTION CONTROL PANEL 2X24 7 CONNECTOR RJ11 (EXPANSION MODULE)
CUSTOMER GND1 2 GROUND 1X3 CONTROL PANEL 2X25 7 ETHERNET RJ45
CONTROL PANEL GND2 2 GROUND 1X3 CONTROL PANEL 2X26 7 MEMORY CARD
CONTROL PANEL GND3 2 GROUND 1X3 CONTROL PANEL E1 7 CONTROLLER CONTROLLER B

CANOPY M1 2 VACUUM PUMP MOTOR CONTROL PANEL E101 8 GPRS MODULE


CUSTOMER S0' 2 MAIN SWITCH CUSTOMER INSTALLATION CONTROL PANEL U2 8 POWER SUPPLY 24VAC/24VDC GPRS MODULE
CUSTOMER T0 2 AUTO TRANSFORMER ONLY 200-230 / 500-575 VAC CONTROL PANEL X1 8 CONNECTOR OF E10 POWER SUPPLY GPRS MODULE
CONTROL PANEL Z1 2 EMC FILTER IT VERSION 380..500V ONLY CONTROL PANEL X153 8 CONNECTOR GPRS MODULE
CONTROL PANEL Z2 2 FERRITE RING RFI REDUCER CONTROL PANEL 1X5 9 CONNECTOR POWER SUPPLY CONTROLLER
CANOPY M2 3 CENTRIFUGAL PUMP MOTOR CP CONTROL PANEL 2X27 9 CONNECTOR CONTROLLER C
CONTROL PANEL Q15 3 CIRCUIT BREAKER CP MOTOR CANOPY TT01 9 ELEMENT OUTLET TEMPERATURE
CONTROL PANEL Z2 3 FERRITE RING RFI REDUCER CANOPY TT02 9 ELEMENT INLET TEMPERATURE
CONTROL PANEL F1 4 FUSE CONTROL CIRCUIT CONTROL PANEL 2X28 10 CONNECTOR CONTROLLER
CONTROL PANEL F4 4 FUSE CONTROL CIRCUIT 110VAC CONTROL PANEL GND9 10 GROUND 1X3
CONTROL PANEL F5 4 FUSE CONTROL CIRCUIT 24VAC CANOPY LS-01 10 LIQUID LEVEL SWITCH SERVICE LIQUID
CONTROL PANEL F6 4 FUSE CONTROL CIRCUIT 24VAC CANOPY PT01 10 PRESSURE SENSOR VACUUM
CONTROL PANEL T1 4 TRANSFORMER CONTROL CIRCUIT 24 /110VAC CONTROL PANEL 2X31 11 CONECTOR CONTROLLER D
CONTROL PANEL 2X30 5 CONNECTOR CONTROLLER
CONTROL PANEL GND5 5 GROUND 1X3
CONTROL PANEL GND6 5 GROUND 1X3
CONTROL PANEL GND7 5 GROUND 1X3
CONTROL PANEL K15 5 CONTACTOR CP MOTOR
MOTOR M3 5 CUBICLE FAN E

CONTROL PANEL S3 5 EMERGENCY STOP PUSH


BUTTON
CONTROL PANEL Y1 5 SOLENOID VALVE LIQUID FILL VALVE
CONTROL PANEL Y2 5 SOLENOID VALVE AIR ( OR EXHAUST GAS)
INJECTION VALVE
CONTROL PANEL Y3 5 SOLENOID VALVE SEPARATOR DRAIN VALVE
CONTROL PANEL Y4 5 SOLENOID VALVE ELEMENT DRAIN VALVE F
copied, used for manufacturing or communicated to any other person or company.

CANOPY PSHH11 6 PRESSURE SWITCH SEPARATOR PRESSURE


This document is our property and shall not without our permission be altered,

MOTOR R1 6 TEMPERATURE SENSOR TYPE PTC IN MAIN MOTOR

G
Designation Sheet 12 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 11 Next Page 13 A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003
1 2 3 4 5 6 7 8 9 10

NOTES : A
Pin configurations
[A] Caution!
- Always double check size of installed fuses versus calculated cable size Pressure transducer
- When required, reduce fuse size or enlarge cable size 1 : Supply V+
2 4
[B] Power supply to be connected for : 2 : Ground
1. CLOCKwise rotation of Centrifugal Pump 3 : Signal 3 1
2. CLOCKwise rotation of vacuum pump motor 4 : Sealed with dummy
to be observed from non drive side (fan).
B

Marking of connectors and terminals


[D] To connect correct transfo-voltage see on transfo Terminal #1 = Terminal with end plate

[E] Tightening torque of bolts:

ABB contactor
Terminal M3.5 1Nm 2
Coil M3.5 1Nm 3
C
1
Inverter NEOS

AC terminals M10 20Nm


PE cable M10 20Nm
end plate
Block filter
Screw Terminal 8Nm
PE connection 20Nm
min wire connection 16mm²/AWG6
max wire connection 35mm²/AWG2 D
2X27, 2X28.4X29
1 3 5 7 9 11 13
[F] For field wiring : use copper 75°C wire only
2 4 6 8 10 12 14
[G] F.P.C Field provided components

[X] Optional remote emergency stop:


Replace bridge by NC contacts of remote emergency stop

F
copied, used for manufacturing or communicated to any other person or company.
This document is our property and shall not without our permission be altered,

G
Designation Sheet 13 (13)
ACDE Name L254 VSD TOTAL RECOVERY VACUUM STATUS Ed. Date Prev. Page 14 Next Page A3
Drawing owner
CQV Preliminary 01
Drawn by
INEPRA
Date
31-10-2019 1950840003

You might also like