UPPERSTRUCTURE / Pump Device

22. Remove stopper (24) from pump casing (51). 27. Remove bearings (10) and (12) as well as ring
(11) from shafts (13) and (19) with a press.
CAUTION: Pump casing weight: 70 kg (154 lb)
CAUTION: Pump casing weight: 42 kg (93 lb)
23. Attach a nylon sling to pump device (51), lift it up
and place the pump casing on the wooden blocks 28. Attach a nylon sling to pump casing (51), lift it up
with mission side facing down. Wooden block by crane and position the regulator with the
size: 100 mm or more in width and height. mounting surface facing up.

24. Remove shafts (13) and (19) from pump casing 29. Remove retaining rings (50) (2 used), oil seals
(51) with special tool (ST 1470) (ST 1471). At this (49) (2 used) from pump casing (51).
time, bearings (10) and (12) are removed with the
shafts. 30. Remove retaining ring (40) from gear casing (47)
and remove retaining ring (41) from gear shaft
Special Tool
ST 1470 (44).
Special Tool
ST 1471 31. Pull out upper ball bearing (42) and gear shaft
(44) from gear casing (47) using special tool (ST
13 1393).

19

44
51

42

W178-02-04-054

25. Remove slide ring (20) from shaft (19).

26. Remove bearing nut (9) from shafts (13) and (19) W178-02-04-009

using special tool (ST 3058).


32. Remove gear (43) and ball bearing (42) from gear
ST 3058 casing (47).

9 33. Install a shackle to the bolt hole on the periphery


of gear casing (47), lift it up with a rope and turn it
over.

34. Remove retaining ring (45), oil seal (46) from gear
casing (47).

W137-02-04-023

W2-4-9