You are on page 1of 1

UPPERSTRUCTURE / Pump Device

REMOVE AND INSTALL PUMP DEVICE


1 2 3 4 5
IMPORTANT: Release any pressure in the hydrau-
lic oil tank before doing any work.
(Refer to BLEED AIR FROM HY- 12
DRAULIC OIL TANK on W1-4-1.)

Removal 11
1. Disconnect connectors (4 places).
CAUTION: Pump device weight: 170 kg
(375 lb)

2. Disconnect hoses (1 to 4 and 6, 7, 9 to 12) and


pipe (8) from the pump device.
: 19 mm, 27 mm, 36 mm 6
: 8 mm, 10 mm
10 9 8 7 W178-02-04-053

IMPORTANT: Do not install the eyebolt to the


regulator which is with solenoid
valve.
Eyebolt Mounting
Position
3. Attach eyebolts (M12, Pitch 1.75) (ST 0002) to the
pump device, then hold it by crane.
4. Remove pump device mounting bolts (5) (8 used)
to remove the pump device.
: 17 mm

Installation
1. Install eyebolt (M12, Pitch 1.75) (ST 0002) on the
pump device and lift by crane.
2. Insert the drive shaft of pump device into the
pump mission, and install it with pump device
mounting bolts (5) (8 used).
: 17 mm
: 50 N⋅m (5.1 kgf⋅m, 37 Ibf⋅ft)
3. Connect hoses (1 to 4 and 6, 7, 9 to 12) and pipe
(8). W178-02-04-019

4. Connect connectors.
Wrench size Tightening torque
Remark
(mm) N⋅m kgf⋅m(Ibf⋅ft)
: 27 93 9.5 (69) Hose
: 36 175 18 (130) Hose
: 10 90 9.2 (67) Bolt
: 17 50 5.1 (37) Bolt
:8 50 5.1 (37) Bolt
: 19 29.5 3 (21.5) Hose

IMPORTANT: Bleed the air from the pump. (Refer


to W1-1-2).
Be sure to check hydraulic oil level,
and any oil leaks, after assembling.
: 27 mm
: 49 N⋅m (5 kgf⋅m, 36 Ibf⋅ft)

W2-4-1