BM - BMe 115mm/4.5" BM3 - BMe3 170mm/6.7"
Capping
145mm
TS OV 5.7"
Torus Ovolo/EasyClean
90mm
Bracket Heights
Pipe Heights
Bracket Heights
3.5" 117mm
Pipe Heights
+ 45mm 4.6"
90mm
62mm +1.7" 3.5"
35mm 2.4"
1.5" 62mm
Colours 35mm 2.4"
1.5"
Cricket Vintage Carbon Anthracite
White Ivory Black Grey
RAL 9010 RAL 9010 RAL 9010 RAL 9010
Connection Data
Water Push Fit Pegler onto pipe, and unique Consumer 32A Type C Breaker- Ring Main covers
Connections patented ThermaSkirt push fit connections Unit all bases for large or small systems.
for all the skirting to skirting seal. 20A Type C Breaker- Radial is suitable for
smaller properties.
Pipe 10mm - Limited to 12m of skirting typically
13A Socket Supply- For small one off
Limitations 15/16mm - Limited to 20m of skirting typically systems, power can be taken from a local
Pipe Size 10mm - Only for use with boilers 240V power socket.
Compatability 15/16mm - For use with boilers or heat pumps Cable 2.5mm² Twin and Earth for power supply
Sizing to thermostat and skirting.
Pipe Copper- it's fine but offers less flexibility when 2/3x 2.5mm² Twin and Earch or 2.5mm²
Material coming to do 2nd fix. 1st fix has to be perfect. 5/7 core cable for thresold kits
Plastic Pipe- Recommended due to flexibility
and adaptability. Any manufacturer.
Typical Boiler
60 - 72 °C
Typical
Heat Pump
40 - 48 °C
Victorian or Older, single glazed,no loft insultation 95 - 110 W/m²No grilles or fins