- Tech Cheat Sheet

Profile Data
BM - BMe 115mm/4.5" BM3 - BMe3 170mm/6.7"
Capping
145mm
TS OV 5.7"
Torus Ovolo/EasyClean
90mm

Bracket Heights
Pipe Heights

Bracket Heights

3.5" 117mm

Pipe Heights
+ 45mm 4.6"
90mm
62mm +1.7" 3.5"
35mm 2.4"
1.5" 62mm
Colours 35mm 2.4"
1.5"
Cricket Vintage Carbon Anthracite
White Ivory Black Grey
RAL 9010 RAL 9010 RAL 9010 RAL 9010

TOP TIP: Best paint match is a Crown Paints- Satin White

Connection Data

Water Push Fit Pegler onto pipe, and unique Consumer 32A Type C Breaker- Ring Main covers
Connections patented ThermaSkirt push fit connections Unit all bases for large or small systems.
for all the skirting to skirting seal. 20A Type C Breaker- Radial is suitable for
smaller properties.
Pipe 10mm - Limited to 12m of skirting typically
13A Socket Supply- For small one off
Limitations 15/16mm - Limited to 20m of skirting typically systems, power can be taken from a local
Pipe Size 10mm - Only for use with boilers 240V power socket.
Compatability 15/16mm - For use with boilers or heat pumps Cable 2.5mm² Twin and Earth for power supply
Sizing to thermostat and skirting.
Pipe Copper- it's fine but offers less flexibility when 2/3x 2.5mm² Twin and Earch or 2.5mm²
Material coming to do 2nd fix. 1st fix has to be perfect. 5/7 core cable for thresold kits
Plastic Pipe- Recommended due to flexibility
and adaptability. Any manufacturer.

Material Data Accreditations


ThermaSkirt Profile Aluminium Alloy (85% recycled) UK Testing Bodies International Testing Bodies
Dummy Profile Primed Finish MDF
Connector Components Glass reinforced nylon
O-Ring Seals Teflon Coated EPDM
Mounting Brackets Polycarbonate
Retaining Clip Pressed Stainless Steel
Top Gasket TPE (Stable up to 150°C)
Top Capping Tropical Grade- UPVC
Product Performance Data

Typical Boiler
60 - 72 °C

Typical
Heat Pump
40 - 48 °C

Electric- Low Temp Electric- High Temp

Operating Current (A) = Total Watts (X) ÷ Voltage (240v)


BMe2 is 0.5A/m & BMe3 is 0.75A/m

Property Performance Requirements


Boiler Heat Pump
Passiv Haus 2 - 10 W/m²

Eco / Low Carbon Homes 10 - 20 W/m² BM2


BM2
Recent New Build (2006 or later) 20 - 40 W/m²

Pre 2006 New Build or Recent Renovation 30 - 50 W/m²

Renovated properties with cavity wall insultation and


40 - 65 W/m²
over 75mm of loft insulation
BM3
Victorian Houses perhaps with some single and some
double glazing, 50-75mm of loft insulation
65 - 85 W/m² BM3

Victorian or Older, single glazed,no loft insultation 95 - 110 W/m²No grilles or fins

If the property is going to be in on/off use + 10%


*The above suggestions are typical/likely. For
smaller rooms, BM2 may hit the target w/m2
In intermittently heated (holiday home/garden room) +20% regardless. Use the above as a customer guide
only.