• Enclosure manufactured from a
highly corrosion resistant, UV
stabilised engineered resin
(Grilamid TR 90 UV).
• Ingress Protection Rating to
IP66/67.
• HiVue visual indicator Beacon
provides local indication of the valve
position for distances up to 50m.
• EasiFix cams are vibration resistant
and self locking for easy switch
adjustment.
• All AVID products are suitable for
Namur mounting.
• The terminal block is supplied
with two extra points for solenoid
valve integration as standard.
• Switch configurations: 2 switches
(standard) or 4 switches (option
for ZR only). Switch configurations
are available from SPDT
mechanical switches, 2 and 3 wire
inductive proximity switches and
the magnetic proximity T-switch.
• IECEx certified options are
available for use in hazardous
areas.
• ZR Plus -
Adds the option of a solenoid
valve fitted as an integral part of
the position monitor. Solenoid
options consist of either aluminium
or stainless steel with a full range
of AC/DC coils available.
Hazardous area certified options
available – consult factory.
• PlantNet - General applications:
Adds the capability for the position
monitor to be compatible with a
variety of BUS protocols.
• ZR Position Monitor: • PlantNet Position Monitor:
General purpose, hazardous area, Incorporates the benefits of the ZR
The PlantNet range can be corrosive and arduous and the ZR Plus and is used where
supplied with or without solenoid environments. communication with BUS
valves (available with 316S/S or
aluminium bodies) and include Asi
• ZR Plus Control Position protocols is required.
Monitor:
(ZR-A), DeviceNet (ZR-D), ProfiBus General purpose, hazardous area,
DP (ZR-P) and Foundation corrosive and arduous
Fieldbus (ZR-F) environments where a solenoid
valve is required as an integral part
of the position monitor assembly.
www.tycoflowcontrol-pc.com
A.B.N. 83 000 922 690
© Copyright by Tyco International Ltd. ZR/4/09
Tyco Flow Control reserves the right to change product designs and specifications without notice.
Controls - ZR Position Monitor
151 133
ZR Certified Ambient Ranges
M20/PG 67
13.5/ 99 -40ºC to +60ºC (T5 - T100ºC)
1/2” NPT
(2 places) 56 -40ºC to +45ºC (T6 - T85ºC)
11
ModMount
(Namur pattern) 19
Solenoid specifications 54
(Namur pattern) 19
Configuration 3/2 or 5/2
Actuator
Mechanical Spring Return 35 127
107
Manual Override Standard Side View Top View
Pressure Rating 2-8bar
Operating Media Inert Gas
Temp Rating -15ºC to +85ºC Micro Switch V3 (Mechanical)
Operations 1,000,000 cycles (Typical) Electrical Version SPDT form C
Electrical Rating 15 amps/125/250 VAC
Classification & Approvals 6 amps/24 VDC
0.5 amps/125 VDC
IECEx
0.25 amps/250 VDC
Ex mb e IIC T* Gb 5 amps/125 VAC ‘L’
Ex tb IIIC T* Db IP6X
Proximity type (Inductive), Intrinsically Safe
ZR+ Certified Ambient Ranges
Sensing range 2 - 4 mm
-15ºC to +50ºC (T5 - T100ºC) Electrical Version D.C. voltage 2 wire in accordance with EN 60947-5-6
Hysteresis Approx. 5%
Certificate: IECEx SIR 08.0131X Switching Frequency 1.0 KHz
*When used with the correct coil and Nominal Voltage 8 VDC
switch combination - consult factory. Input Voltage Range 5 - 25 VDC
Output/Current
Enclosure Consumption ≥1mA, ≤3mA
Power
LED
Power and communication input
J2 J4
J4
ASI ASI 1 2 3 4 1
1 2
2 3
3 4
4
ASI (Blue) (Brown) ASI
(Blue) (Brown)
1 2 3 4
INPUT 1
OUT 1
J1
OPEN +24 V
LIMIT SW
OUT 0
Side +24 V
View Internal
Hall Effect INPUT 0 INPUT 3
sensors CLOSE +24 V
LIMIT SW
INPUT 2
+24 V
Technical Data
Current consumption 140mA max
Input voltage 24V BUS
Temperature range -40°C to +85°C
Physical I/O 2 Hall Effect Inputs (Close and Open Limit Switches)
2 Dry Contact Inputs (Auxiliary Inputs)
2 Open Drain Outputs (Solenoid Outputs)
Visual indication Network power available to module (Green LED)
Closed Limit Switch (CLSD LIMIT SW IN 0, Yellow LED)
Open Limit Switch (OPEN LIMIT IN 1, Yellow LED)
Aux Input 2 (IN 2, Yellow LED)
Aux Input 3 (IN 3, Yellow LED)
Output 0 (Out 0, Red LED)
Output 1 (Out 1, Red LED)
Side Internal
View Hall Effect
sensors
Technical Data
Current consumption 105 mA
Input voltage (from Bus) 24V BUS
Temperature range -40 C to +85 C
Physical I/O 2 Hall Effect inputs (Close & Open Limit Switches)
2 Dry Contact Inputs (Auxiliary Inputs)
2 Open Drain Outputs (Solenoid Outputs)
Visual indication Module & Network diagnostics
Closed Limit Switch (IN 0, CLSD Yellow LED)
Open Limit Switch (IN 1, OPEN Yellow LED)
Aux Input 2 (IN 2, Yellow LED)
Aux Input 3 (IN 3, Yellow LED)
Output 0 (Out 0, Red LED)
Output 1 (Out 1, Red LED)
Diagnostic features Module:
Normal condition
Commissioning required
Unrecoverable falut
Recoverable fault
Network:
Device is allocated to Master.
Device is not allocated to Master.
Communication state
I/O connection has reached a time-out state
Side OUT 0-
OUT 0+
View HS2
Internal GND
Technical Data
Current consumption 120mA (max)
Input voltage (from bus) 18-30Vdc
Temperature range 0°C to +70°C (standard) -40°C to +85°C (consult factory)
Physical I/O 2 Hall Effect Inputs (Close and Open Limit Switches)
4 Dry Contact Inputs (Auxiliary Inputs)
2 Open Drain Outputs (Solenoid Outputs)
Visual indication Module and Network diagnostics
Closed Limit Switch (CL-LS, Yellow LED)
Open Limit Switch (OP-LS, Yellow LED)
Aux Input 2 (IN 2, Yellow LED)
Aux Input 3 (IN 3, Yellow LED)
Aux Input 4 (IN 4, Yellow LED)
Aux Input 5 (IN 5, Yellow LED)
Output 0 (Out 0, Yellow LED)
Output 1 (Out 1, Yellow LED)
Diagnostics features Valve cycle counter
Average valve open time
Average valve close time
Excess cycle time alarm
Note
The AVID® range of Plantnet Monitors offers interface connection to both Profibus DP and Profibus PA.
Consult Factory for ProfiBus PA applications
• Blocks available:
1 x Resource block
J2 J4
J3
1 x Transducer block Fieldbus input 1 2 3 4 1 2 3 4
4 x Discrete input
2 x Discrete output
INPUT 1
• Solenoid option available with 1
J1
2 OPEN
LIMIT SW
either 316S/S or anodised
aluminium body. Internal
Side Hall Effect INPUT 0
View sensors CLOSE
LIMIT SW
Technical Data
Current consumption 24 mA (including solenoid current)
Input voltage (from Bus) Non Polarized, 9 to 32 Vdc
Temperature range -40°C to +85°C (no solenoid) -10°C to +85°C (with solenoid)
Physical I/O 2 Hall Effect inputs (Close & Open Limit Switches)
2 Dry Contact Inputs (Auxiliary Inputs)
2 Open Drain Outputs (Solenoid Outputs)
Visual indication Module Health (DS1, Green Flashing LED)
Close Limit Switch (CLSD, Yellow LED)
Open Limit Switch (OPEN, Yellow LED)
Aux Input 1 (IN 1, Yellow LED)
Aux Input 2 (IN 2, Yellow LED)
Output 0 (OUT 0, Red LED)
Output 1 (OUT 1, Red LED)
Function blocks 4 Discrete Input Blocks
2 Discrete Output Blocks
Diagnostic features Valve Breakaway Time
Valve Cycle Time
Valve Cycle Counter
Excess Cycle Time Alarm
Code
ZR
Application
0 = No solenoid
1 = Solenoid
A = Asi (Plantnet)
P = Profibus (Plantnet)
F = Foundation Fieldbus (Plantnet)
C = 4-20mA Transmitter
Conduit entry
2 = (1) M20
B = (2) M20
No. of Switches
2
4
Switch options
01 = V3 SPDT Mechanical
02 = T Proximity Switch SPDT
03 = Namur (P&F NJ2-V3-N)
06 = Plantnet Proximity
10 = (IFM IS5026) 5-36Vdc NO/NC NPN/PNP
11 = (IFM IS5001) 10-36Vdc NO PNP
12 = (IFM IS0003) 20-140Vdc/10-140Vdc
45 = (IFM IS5003) 10-36Vdc NO NPN
61 = (IFM IS5002) 10-36Vdc NC PNP
62 = (IFM IS5004) 10-36Vdc NC NPN
Terminal strip
B = 8 point
C = 9 point
Bracket type
D = Direct (MOD) Mount*
Features
AA = Grilamid outer HiVue Indicator