FORM R405-2022 Supplement

FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION


Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: South Miami Res Street: Builder Name: TBD
2412 DEL MAR PLACE Permit Office:
City, State, Zip: F, Laud, FL, Owner: Permit
Design Location: FL, Fort Lauderdalel Number:
Jurisdiction: Fort Lauderdale. (Florida Climate Zone 1)
County:
1. New construction or existing Existing (From 10. Wall Types(1053,8 sqft.) Insulation Area
2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1053,8 ft2
3. Number of units, if multiple family 1 b. Concrete Block - Int Insul, Adjacent R=13.0 ft2
4. Number of Bedrooms 3 c. N/A
5. Is this a worst case? No d. N/A
6. Conditioned floor area above grade (ft²) 1053,8 11. Ceiling Types (2063 sqft.) Insulation Area
Conditioned floor area below grade (ft²) 0 a. Single assembly, with (Unvented) R=30.0 2339,7 ft2
7. Windows(438,5 sqft.) Description Area b. N/A
a. U-Factor: Sgl, U=0.56 567,8 ft2 c. N/A
SHGC: SHGC=0.61 12. Roof(Concrete, Unvent) Deck 2361 ft2
b. U-Factor: N/A ft2 SHGC: 13. Ducts, location & insulation level R ft2
c. U-Factor: N/A ft2 SHGC: a. Sup: AHU1, Ret: AHU1, AH: AHU1 6 100
Area Weighted Average Overhang Depth: 0.461 ft Area b. Sup: AHU2, Ret: AHU2, AH: AHU2 6 100
Weighted Average SHGC: 0.250 c. 2 additional duct system(s) (see details)
8. Skylights Description Area 14. Cooling Systems kBtu/hr Efficiency
U-Factor:(AVG) N/A N/A ft2 a. Central Unit 24 SEER2:14,50
SHGC(AVG): N/A b. Central Unit 35,8 SEER2:14,50
9. Floor Types Insulation Area 2 additional cooling systems (see details)
a. Slab-On-Grade Edge Insulation R= 0.0 2239 ft2 15. Heating Systems kBtu/hr Efficiency
b. N/A R= ft2 a. Electric Strip Heat
c. N/A R= ft2 b. Electric Strip Heat
2 additional heating systems (see details)
16. Hot Water Systems
a. ElectricTankless Cap: 1 gallons
UEF: 0.940
b. Conservation features
None
17. Credits Pstat
Glass/Floor Area: 0.391 Total Proposed Modified Loads:
Total Baseline Loads: PASS
I hereby certify that the plans and specifications covered by this calculation Review of the plans and
are in compliance with the Florida Energy Code. specifications covered by this
Digitally signed by
DN: c=US, o=AMERICAN UNITED
calculation indicates compliance
PREPARED BY: with the Florida Energy Code.
ENGINEERS,
Before construction is completed
this building will be inspected for
DATE:
Date: 2023.10.20 13:08:35 -04'00' compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance with the Florida Statutes.
Florida Energy Code. BUILDING OFFICIAL:
OWNER/AGENT: DATE: DATE:

- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-
sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to
outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.015 Qn for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a
PERFORMANCE envelope leakage test report with envelope leakage no greater than 3.50 ACH50 (R402.4.1.2).

10/19/2023 5:56:53 AMEnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software Page 1
FORM R405-2022S INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Fort Lauderdale Res Address type: Street Address
Building Type: User Bedrooms: 3 Lot #: ---
Owner: Conditioned Area: 2239 Block/SubDivision: ---
Total Stories: 1 PlatBook: ---
Builder Name: TBD Worst Case: NO Street: 2412 S DEL MAR PLACE
Permit Office: Rotate Angle: 0 County: BROWARD
Jurisdiction: Cross Ventilation: City, State, Zip: Fort Lauderdale.
Family Type: Detached Whole House Fan: FL,
New/Existing: New (From Plans) Terrain:
Year Construct: Shielding:
Comment: Comment:

CLIMATE
Design Location Design Temp Int Design Temp Heating Design Daily temp
Tmy Site 90,0% 1% Winter Summer Degree Days Moisture Range

FL, FORT FL, HOLLYWOOD_FORT-


LAUDERDALE INT LAUDERDALE INT 50 90 70 75 149.5 56 Low

BLOCKS
Number Name Area Volume

1 Block1 1562 15620 cu ft

2 Block2 677 6770 cu ft

SPACES
Number Area Volume Kitchen Occupants Bedrooms Finished Cooled
Heated
Name
1
AHU1 1562 15620 Yes 4 0 Yes Yes Yes
2
AHU2 677 6770 No 2 1 Yes Yes Yes

FLOORS (Total Exposed Area = 2239 sq.ft.)

Exposed Joist R-
# Floor Type Space Perimeter R-Value Area U-Factor Tile Wood Carpet
Perim Value

1 Slab-On-Grade Edge Ins AHU1 151 0 1562 0,366 --- 0.00 0.00 1.00

2 Slab-On-Grade Edge Ins AHU2 86,5 0 677 0,366 --- 0.00 0.00 1.00

ROOF
Emitt Pitch
Materials
Roof Gable Roof Rad Solar SA Emitt Deck (deg)
# Type
Area Area Color Barr Absr. Tested Tested Insul
1 Flat
Concrete 2239 ft² 888ft² Light N 0.6 No 0.9 No 0 4.76

10/19/2023 5:56:53 AMEnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software Page 2
FORM R405-2022S INPUT SUMMARY CHECKLIST REPORT
ATTIC
# Ceiling Type Ventilation Vent Ratio (1 in) Area RBS IRCC

1 No Unvented 0 3893. ft2 N N


attic
CEILING (Total Exposed Area = 2239 sq.ft.)
#
Space R-Value Ins. Type Area U-Factor Framing Frac.

1 Single assembly, with airspace(Unvented) AHU1 30.0 Blown 1562 ft² 0,032 0.11 Wood
2 Single assembly, with airspace(Unvented) AHU2 30.0 Blown 677 ft² 0,032 0.11 Wood
3
4

WALLS (Total Exposed Area = 1053,8 sq.ft.)


Cavity Width Height Area U- Factor Sheath Frm. Solar Below
Adjacent
# Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. R-Value Frac. Absor. Grade

1 N Exterior Conc. Blk - Int Ins AHU1 4.1 1,0 0,0 10,0 0 10,0 0,083 0 0 0.80 0%
2 N Exterior Conc. Blk - Int Ins AHU1 4.1 3,0 4,0 2,0 0 6,7 0,083 0 0 0.80 0%
3 N Exterior Conc. Blk - Int Ins AHU1 4.1 3,0 4,4 10,0 0 33,7 0,083 0 0 0.80 0%
4 N Exterior Conc. Blk - Int Ins AHU1 4.1 10,0 2,5 3,3 0 33,7 0,083 0 0 0.80 0%
5 N Exterior Conc. Blk - Int Ins AHU1 4.1 2,0 10,0 10,0 0 28,3 0,083 0 0 0.80 0%
6 S Exterior Conc. Blk - Int Ins AHU1 4.1 7,0 1,8 10,0 0 71,5 0,083 0 0 0.80 0%
- 7 S Exterior Conc. Blk - Int Ins AHU1 4.1 6,5 4,0 3,3 0 22,6 0,083 0 0 0.80 0%
8 S Exterior Conc. Blk - Int Ins AHU1 4.1 0,0 9,0 10,0 0 7,5 0,083 0 0 0.80 0%
9 S Exterior Conc. Blk - Int Ins AHU1 4.1 1,0 4,0 10,0 0 13,3 0,083 0 0 0.80 0%
10 S Exterior Conc. Blk - Int Ins AHU1 4.1 12,0 4,0 3,3 0 40,7 0,083 0 0 0.80 0%
11 S Exterior Conc. Blk - Int Ins AHU1 4.1 1,0 4,0 10,0 0 13,3 0,083 0 0 0.80 0%
12 S Exterior Conc. Blk - Int Ins AHU1 4.1 6,0 11,0 10,0 0 69,2 0,083 0 0 0.80 0%
13 E Exterior Conc. Blk - Int Ins AHU1 4.1 10,0 0,0 10,0 0 100,0 0,083 0 0 0.80 0%
14 E Exterior Conc. Blk - Int Ins AHU1 4.1 4,0 0,0 3,3 0 13,2 0,083 0 0 0.80 0%
15 E Exterior Conc. Blk - Int Ins AHU1 4.1 3,0 10,3 10,0 0 38,5 0,083 0 0 0.80 0%
16 W Exterior Conc. Blk - Int Ins AHU1 4.1 9,0 0,0 10,0 0 90,0 0,083 0 0 0.80 0%
17 W Exterior Conc. Blk - Int Ins AHU1 4.1 2,0 0,0 3,3 0 6,6 0,083 0 0 0.80 0%
18 W Exterior Conc. Blk - Int Ins AHU1 4.1 9,0 3,6 3,3 0 30,7 0,083 0 0 0.80 0%
19 W Exterior Conc. Blk - Int Ins AHU1 4.1 1,0 7,0 10,0 0 15,8 0,083 0 0 0.80 0%
20 E Exterior Conc. Blk - Int Ins AHU2 4.1 15,0 0,0 3,3 0 49,5 0,083 0 0 0.80 0%
21 E Exterior Conc. Blk - Int Ins AHU2 4.1 11,0 4,0 10,0 0 113,3 0,083 0 0 0.80 0%
22 E Exterior Conc. Blk - Int Ins AHU2 4.1 2,0 7,0 3,3 0 8,5 0,083 0 0 0.80 0%
23 S Exterior Conc. Blk - Int Ins AHU2 4.1 8,0 7,0 3,3 0 28,3 0,083 0 0 0.80 0%
24 S Exterior Conc. Blk - Int Ins AHU2 4.1 6,0 8,0 10,0 0 66,7 0,083 0 0 0.80 0%
25 S Exterior Conc. Blk - Int Ins AHU2 4.1 4,0 0,0 3,3 0 13,2 0,083 0 0 0.80 0%
26 W Exterior Conc. Blk - Int Ins AHU2 4.1 2,0 0,0 3,3 0 6,6 0,083 0 0 0.80 0%
27 W Exterior Conc. Blk - Int Ins AHU2 4.1 24,0 0,0 10 0 240,0 0,083 0 0 0.80 0%
28 W Exterior Conc. Blk - Int Ins AHU2 4.1 1,0 5,2 10 0 14,3 0,083 0 0 0.80 0%
29 W Exterior Conc. Blk - Int Ins AHU2 4.1 2,0 0,0 3,3 0 6,6 0,083 0 0 0.80 0%
30 W Exterior Conc. Blk - Int Ins AHU2 4.1 0,0 9,6 10,0 0 8,0 0,083 0 0 0.80 0%

10/19/2023 5:56:53 AMEnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software Page 3
FORM R405-2022S INPUT SUMMARY CHECKLIST REPORT
DOORS (Total Exposed Area = 57 sq.ft.)

Adjacent Door Width Height


# Ornt Space Storms U-Value Area
To Type Ft In Ft In
1
SW Exterior Wood AHU1 None 0.46 6.00 4 9.00 0 57.0 ft²

WINDOWS (Total Exposed Area = 567,7 sq.ft.)


Total --Overhang--
Wall Same Width Height
# Ornt Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Sep. Interior Shade Screen
ID Units (ft) (ft)
(ft²) (ft) (ft)

1 N 2 Wood Single (Clear) Y 0.70 0.25 N N 18,6 1 2,7 6,8 3,0 3,0 None None
2 N 5 Wood Single (Clear) Y 0.70 0.25 N N 69,6 1 10,2 6,8 3,0 3,0 None None
3 E 8 Wood Single (Clear) Y 0.70 0.25 N N 27,0 1 4,0 6,8 3,0 3,0 None None
4 E 9 Wood Single (Clear) Y 0.70 0.25 N N 38,8 1 5,7 6,8 3,0 3,0 None None
5 S 13 Wood Single (Clear) Y 0.70 0.25 N N 96,0 1 14,1 6,8 8,0 3,0 None None
6 S 14 Wood Single (Clear) Y 0.70 0.25 N N 27,0 1 4,0 6,8 3,0 3,0 None None
7 S 13 Wood Single (Clear) Y 0.70 0.25 N N 46,7 1 6,9 6,8 3,0 3,0 None None
8 W 14 Wood Single (Clear) Y 0.70 0.25 N N 13,5 1 2,0 6,8 3,0 3,0 None None
9 W 17 Wood Single (Clear) Y 0.70 0.25 N N 13,5 1 2,0 6,8 27,0 3,0 None None
10 E 19 Wood Single (Clear) Y 0.70 0.25 N N 96,0 2 14,1 6,8 3,0 3,0 None None
11 E 21 Wood Single (Clear) Y 0.70 0.25 N N 19,0 2 2,8 6,8 3,0 3,0 None None
12 S 24 Wood Single (Clear) Y 0.70 0.25 N N 59,0 2 8,7 6,8 12,0 3,0 None None
13 S 26 Wood Single (Clear) Y 0.70 0.25 N N 27,0 2 4,0 6,8 3,0 3,0 None None
14 W 27 Wood Single (Clear) Y 0.70 0.25 N N 8,0 2 1,2 6,8 3,0 3,0 None None
15 N 28 Wood Single (Clear) Y 0.70 0.25 N N 8,0 2 1,2 6,8 12,0 3,0 None None

10/19/2023 5:56:53 AMEnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software Page 4
FORM R405-2022S INPUT SUMMARY CHECKLIST REPORT

INFILTRATION
# Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s) Infiltration Test Volume

1
Wholehouse ProposedACH(50) 0.00021 2533 140,722 253,3 0.32 6,8 All 22350 cu ft

GARAGE
#
Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation

1
279 ft² 279 ft² 237,5 ft 10 ft 3

MASS
#
Mass Type Area Thickness Furniture Fraction Space

1
Default(8 lbs/sq.ft.) 0 ft² 0 ft 0.30 AHU1
2
Default(8 lbs/sq.ft.) 0 ft² 0 ft 0.30 AHU2
3
Default(8 lbs/sq.ft.) 0 ft² 0 ft 0.30 AHU3
4
Default(8 lbs/sq.ft.) 0 ft² 0 ft 0.30 AHU4

HEATING SYSTEM
Ducts Block
# System Type Subtype AHRI # Efficiency ----Geothermal HeatPump----
Capacity
kBtu/hr Entry Power Volt Current

1 sys#1
Electric Strip Heat None COP: 1.00 0.00 0.00 0.00 1
2 sys#2
Electric Strip Heat None COP: 1.00 0.00 0.00 0.00 2
3

COOLING SYSTEM
Subtype/Speed AHRI # Efficiency SHR Duct Block
# Capacity Air Flow
System Type
kBtu/hr cfm

1
Central Unit Split/Single 201278739 SEER2:14,5 24,0 800 0.75 sys#1 1
2
Central Unit Split/Single 201376825 SEER2:14,5 36,0 1100 0.75 sys#2 2

HOT WATER SYSTEM


#
System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length

1
Electric Tankless AHU1 0.94 (0.94) 1.00 gal 60 gal 120 deg Standard =>R-3 99

DWHR
Recirculation Recirc Control Loop Branch Pump Facilities Equal DWHR
Other Credidts
System Type Length Length Power Connected Flow Eff

1
No NA NA NA NA No NA NA NA None

10/19/2023 5:56:53 AMEnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software Page 5
FORM R405-2022S INPUT SUMMARY CHECKLIST REPORT

DUCTS
Duct ---------Supply--------- ---------Return--------- RLF
# Location R-Value Location R-Value Air CFM 25 CFM 25 HVAC #
QN
Handler TOT OUT Heat Cool
Area Area Leakage Type
1 AHU1 6,0 100 ft² AHU1 6,0 0 ft² Proposed Qn AHU1 --- --- 0,01 0,50 1 1
2 AHU2 6,0 100 ft² AHU2 6,0 0 ft² Proposed Qn AHU2 --- --- 0,01 0,50 2 2

TEMPERATURES
Programable Thermostat: Y Ceiling Fans: N
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec
Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12

Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 78 78 78 78 78 78 78 78 78 78
80
Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78
78
Heating (WD) AM 66 66 66 66 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68
68
Heating (WEH) AM 66 66 66 66 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68
68

10/19/2023 5:56:53 AMEnergyGauge® USA 7.5.00 - FlaRes2020 FBC 7th Edition (2022 Supplement) Compliant Software Page 6