Professional Documents
Culture Documents
Flight 60T
Oxygen
• Manual Breath 0 to 3 sec
®
• High Pressure/Low Flow Port 35 to 90 psi / 0 to 15 l/min
• Volume Control Time/Flow
• Compatible with oxygen tanks and concentrator
• PSV flow termination 10% to 90% Communication
• 2 USB ports Download logs, SW upgrade
• 2 external RS232 connectors Remote Alarm and Monitoring
• Flow Trigger 1 to 20 l/min • RJ 45 connector
• Rise Profile 5 levels Standards
• Inspiratory Time (Ti) 0.1 to 3 sec • IEC 60601-1, IEC 60601-1-2, IEC 60601-2-12, ISO 10651-2/3,
Reliable Ventilation
DOC-0566 Rev A00
www.flight-medical.com 0483
FDA cleared
Flight Medical Innovations Ltd. manufactures, develops and markets life The Flight 60T is a fully independent, turbine-based,
supporting respiratory ventilators for critical care and emergency ventilator.
environments, long term acute care facilities, homecare, transport,
military, mass casualty and emergency preparedness.
The worldwide deployed Flight 60T is both a
Flight 60T
volume-control and pressure-control ventilator for
®
invasive and noninvasive ventilation.
Provides high quality A versatile ventilator with LTAC and homecare When it is time for NIV, Transport and EMS Ease of operation
mechanical ventilation ICU – level expectations clinicians no longer need to
in all clinical situations switch devices
Adults and pediatric patients ICU modes: B-Lev, PRVC, Volume Guarantee Invasive and non-invasive ventilation Automatic leak compensation allows for Whether it is critical care transport outside 7’’ color touch screen clearly visible even
greater than 5 kg Continuous monitoring of breathing the hospital, emergency preparedness or outside in bright daylight or with
Pressure and volume control parameters ventilate your patients in any care environment in a wide range of modes mass casualty response, the Flight 60 fluorescent lighting
ventilation Pressure support in CPAP and BiPAP modes provides a sturdy and reliable solution for All parameters and alarms displayed on one
Flow or Pressure Trigger for optimum all levels of required ventilation. Its
Basic and advanced modes patient-machine synchrony quick ventilation options to provide ideal assistance screen
autonomous platform allows caregivers to Intuitive user interface requires minimum
Non-invasive and invasive Internal Mixer: Low flow and high pressure The Flight 60T’s portability, along with long battery life, Both Flow and Pressure Trigger options treat patients in any environment, while
ventilation O2, 100% O2 preset is the perfect solution when it comes to providing When moving between invasive and training
conserving oxygen and power.
Customized apnea backup ventilation to powerful ventilation non-invasive therapies utilize the same Curves and loops
Move the patient on all ventilation modes
keep patients’ parameters Low flow oxygen inlet, no need to have high pressure equipment and same patient circuit 72 hours of trends
Autonomous: 8 hours of independent
Extensive alarms system oxygen source Integrated and compensated nebulizer (Not ventilation plus hot swappable battery Adjustable alarms
Splash-proof: Allows the patient to leave the ventilator available in USA) Downloadable event logs
Does not require connection to air inlet Any power source, in flight certification
near the shower Customizable configurations
Lung mechanics Five Preset modes: Allows clinicians to focus
Lockable screen to avoid any unattended action their attention on the patient and reduces
Ability to dim visual screen for night time patient comfort time to make the right clinical decision
Mouthpiece ventilation capabilities