RXQ6-20AYM(W) / RXQ18-60AMYM(W) EDRMT341773D

1. Specifications
1.1 Cooling Only 50/60 Hz VRV A SERIES (RXQ-A(M))

Model Name RXQ6AYM(W) RXQ8AYM(W)


Power supply 3 phase, 380-415/380 V, 50/60 Hz 3 phase, 380-415/380 V, 50/60 Hz
kcal/h 13,800 19,300
1 Cooling capacity Btu/h 54,600 76,400
kW 16.0 22.4
Casing color Ivory white (5Y7.5/1) (Metallic brown H3) Ivory white (5Y7.5/1) (Metallic brown H3)
Dimensions: (H×W×D) mm 1,657×930×765 1,657×930×765
Heat exchanger Cross fin coil Cross fin coil
Type Hermetically sealed scroll type Hermetically sealed scroll type

Compressor Motor output× kW 2.3×1 3.4×1


Number of units
Starting method Soft start Soft start
Type Propeller fan Propeller fan
Motor output kW 0.55×1 0.55×1
Fan
Airflow rate m³/min 119 178
Drive Direct drive Direct drive
Connecting Liquid pipe mm f9.5 C1220T (Brazing connection) f9.5 C1220T (Brazing connection)
pipes Gas pipe mm f19.1 C1220T (Brazing connection) f19.1 C1220T (Brazing connection)
Mass kg 175 (180 H3) 175 (180 H3)
2 Sound pressure level dB(A) 56 56
High pressure switch, Fan driver overload High pressure switch, Fan driver overload
Safety devices protector, Over current relay, Inverter overload protector, Over current relay, Inverter overload
protector protector
Capacity control % 25-100 20-100
Refrigerant name R410A R410A
Refrigerant Charge kg 5.9 5.9
Control Electronic expansion valve Electronic expansion valve
Refrigerator oil Refer to the nameplate of compressor Refer to the nameplate of compressor
Installation manual, Operation manual, Installation manual, Operation manual,
Standard accessories Connection pipes, Clamps Connection pipes, Clamps
Specifications C: 3D111543E (C: 3D121761 H3) C: 3D111543E (C: 3D121761 H3)
Drawing No.
Sound level C: 4D112438B C: 4D112439D

Notes:
+1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m. Conversion formulae
+2. Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. kcal/h=kW×860
During actual operation, these values are normally somewhat higher as a result of ambient conditions and Btu/h=kW×3412
oil recovery mode.
When there is concern for noise the surrounding area such as residences, we recommend investigating
the installation location and taking soundproofing measures.
+3. Models with (W) are the outdoor units with anti-corrosion specifications. For details, refer to Anti-Corrosion
Model (W type) in Part 5 Guide Specifications.