PYRENEES HIGH WALL INVERTER R-410A 50HZ COOLING ONLY

YHJE 09 to 18 ZERAMHORX
YHJE 24 ZERAMCORX
A complete range from 9000 to 24000 Btu/h
PYRENEES HIGH WALL INVERTER R-410A 50HZ COOLING ONLY

Indoor Unit
• Modern, compact design
• Efficient cooling
• Auto restart
• Low noise
• Air sweep 9-18K
• Louver position memory
• Wired controller (Option)
• 3D air flow (Option)

Remote Control
• 4 operation modes
• Sleep mode and on/off timers
• Turbo cool settings
24K
• Follow me
• LCD display

Condensing Unit
• Fashion appearance
• Convenient installation
• Easy maintenance
• Valve protection cover

The YORK ® line of High Wall Air Conditioners includes a wide range of sizes
to give you more flexibility in your product offering. Each model is designed to
provide comfort and efficiency, in an easy-to-operate unit and the sleek design
fits a variety of spaces, whether it’s in a home or office. Models meet the highest
energy efficiency ratings, so less energy is consumed without sacrificing comfort
and performance. Both the condensing and indoor units are engineered for quiet
operation. And comfort control settings are easily changed with the touch of a
button on the remote control.

2
PYRENEES HIGH WALL INVERTER R-410A 50HZ COOLING ONLY

Features and Benefits

DC Inverter Compressor R-410A


DC inverter compressor provides more comfortable
Environmentally-friendly refrigerant cools and heats
indoor environment, higher performance in partial
INVERTER load and better heating performance in low more efficiently without destroying the ozone layer.
ambient temperature than fixed compressor.

Turbo Mode 24-Hour Timer


Provides quicker cooling with one press of the Allows programmed start times up to 24 hours
remote button. in advance for flexible and more convenient
operation.

Multi-Speed Fan Self Diagnosis


Multi-speed fan helps satisfy various airflow Clearly displayed failure codes allow for quicker
requirements. troubleshooting and easier maintenance.

Auto Restart 3-Minute Protection


Unit is automatically returned to previous A 3-minute delay before the compressor will
operating conditions after a power outage, for restart helps avoid compressor damage and
simplified operation. work time.

Follow Me
A temperature sensor embedded in the remote WIFI Control (Option)
control helps ensure accurate air temperature Controls air conditioner with Smart phone or
around the user and not just around the indoor tablet through Internet.
unit, providing maximum comfort.

Refrigerant Leakage Detect


If there is refrigerant system block, leakage, or compressor
overload, the indoor unit will display “EC” and stop the unit.
It’s easy for after service people to diagnosis the problem
and solve it ASAP.

3
Specification

York Set Model YHJE09ZERAMHORX YHJE12ZERAMHORX YHJE18ZERAMHORX YHJE24ZERAMCORX


York Outdoor Model YHJE09YERAMHO-X YHJE12YERAMHO-X YHJE18YERAMHO-X YHJE24YERAMCO-X
York Indoor Model YHJE09XERAMH-RX YHJE12XERAMH-RX YHJE18XERAMH-RX YHJE24XERAMC-RX
Power supply Ph-V-Hz 220-240V- 50Hz, 1Ph 220-240V- 50Hz, 1Ph 220-240V- 50Hz, 1Ph 220-240V- 50Hz, 1Ph
Capacity Btu/h 9000 12000 18000 24000
Power Input W 733 977 1465 1954
Cooling
Rated current A 3.4 4.4 6.7 8.9
EER W/W 3.60 3.60 3.60 3.6
Max. input consumption W 1430 1760 2200 3250
Max. current A 6.5 8.0 10 15.5
Type ROTARY ROTARY ROTARY ROTARY
Compressor Power Input W 748 748 1035 1970
Rated current(RLA) A 5.35 5.35 7.32 6.95
Power Input W 40 58 77 100
Indoor fan motor Capacitor μF 1.2 1.5 3.0 3.5
Speed(Hi/Mi/Lo) r/min 1120/1000/800 1100/800/700 1150/1050/950 1200/950/750
Indoor air flow (Hi/Mi/Lo) m3/h 580/470/290 750/550/510 1160/930/650 1430/1090/830
Indoor noise level (Hi/Mi/Lo) dB(A) 40/35/28 42/37/33 47/45/37 50/45/38
Dimension (W*H*D) mm 802x297x189 965x319x215 1080x335x226 1259x362x282
Indoor unit Packing (W*H*D) mm 875x375x285 1045x405x305 1155x415x315 1340x450x380
Net/Gross weight kg 8.5/11.5 11.5/15.1 14.5/18 21/26.7
Power Input W 72.5 72.5/67 144 144
Outdoor fan
Capacitor μF 2.5 2.5 3.0 3.0
motor
Speed r/min 860 / - / - 850 / 770 / - 860 / - / - 860 / - / -
Outdoor noise level dB(A) 53 55 56 60
Dimension (W*H*D) mm 770x555x300 770x555x300 845x702x363 845x702x363
Outdoor unit Packing (W*H*D) mm 900x585x345 900x585x345 965x755x395 965x755x395
Net/Gross weight kg 24.6/26.9 26.5/28.9 37/40.2 50/53
Refrigerant type g R410A/560 R410A/800 R410A/1250 R410A/1450
Design pressure MPa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5
Liquid side/ Gas side mm Ø6.35/Ø9.52 Ø6.35/Ø12.7 Ø6.35/Ø12.7 Ø9.52/Ø15.9
Refrigerant piping Max. refrigerant pipe length m 25 25 30 30
Max. difference in level m 10 10 20 20
Connection wiring 4x1.5(Option) 4x2.5(Option) 4x2.5(Option) 4x1.5(Option)
Operation temperature °C 17-30 17-30 17-30 17-30
Ambient temperature (Cooling) °C 0-50 0-50 0-50 0-50
Application area (Cooling Standard) m2 12-18 24-35 23-33 28-41
Qty’per 20’ /40’ /40' HQ 105/220/248 90/190/210 66/138/152 55/112/128
Nominal testing conditions:
Cooling - Indoor 80.6°F DB / 66.2°F WB (27°C DB / 19°C WB) & Outdoor 95°F DB / 75.2°F WB (35°C DB / 24°C WB)