MTL4513

MTL4513 – MTL5513 Hazardous area Safe area


SWITCH/ PROXIMITY To earth-leakage
detector *
DETECTOR INTERFACE 680Ω

2-channel, line fault detection, phase reversal 22kΩ + 6 12


5 11
– 4 10 Outputs

The MTLx513 enables two solid-state outputs in the safe area to 680Ω 3 9 Ch 2
+
be controlled by two switches or proximity detectors located in the 2 8
– Ch 1
hazardous area. The Ch1/Ch2 output transistors share a common 1 7
22kΩ
terminal and can switch +ve or -ve polarity signals. Independent output
phase reversal and line fault detection are enabled via switches for Switch-type sensors 13 14
each output. LFD indication is provided on the top of the module. require resistors 20 to 35V dc
if LFD is selected Vs+
Vs–
SPECIFICATION
See also common specification
MTL5513
Number of channels Hazardous area Safe area
Two
Location of switches To earth leakage
detector *
Zone 0, IIC, T6 hazardous area 680Ω
Div. 1, Group A hazardous location
Location of proximity detectors 22kΩ +
6 7
Zone 0, IIC, T4–6 hazardous area if suitably certified 5 8
– 4
9
Div. 1, Group A hazardous location Outputs
Hazardous-area inputs 680Ω 3 10 Ch 2
+
Inputs conforming to BS EN60947–5–6:2001 standards for 2 11
– 1 12 Ch 1
proximity detectors (NAMUR) 22kΩ
Voltage applied to sensor 13 Vs–
7 to 9V dc from 1kΩ ±10% 14 Vs+
Switch-type sensors
Input/output characteristics require resistors 20 to 35V dc
Normal phase if LFD is selected
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected) * Signal plug HAZ1-3 is required for access to this function
User-selectable for each channel via switches on the side of the LED indicators
unit. Line faults are indicated by an LED for each channel. Green: power indication
Open-circuit alarm on if Iin < 50µA Yellow: two: channel status, on when output active
Open-circuit alarm off if Iin > 250µA Red: two: LFD indication, on when line fault detected
Short-circuit alarm on if Rin < 100Ω
Maximum current consumption
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
30mA at 24V
500Ω to 1kΩ in series with switch Power dissipation within unit
20kΩ to 25kΩ in parallel with switch 0.65W typical at 24V, with 10mA loads
Phase reversal 0.78W max. with 50mA loads
Independent for each channel, user-selectable Safety description (each channel)
Safe-area outputs Uo =10.5V Io =14mA Po =37mW Um = 253V rms or dc
Floating solid-state outputs compatible with logic circuits
Operating frequency: dc to 500Hz
Max. off-state voltage: ± 35V
Max. off-state leakage current: ± 50µA
Max. on-state resistance: 25Ω
Max. on-state current: ± 50mA

The given data is only intended as a product description and should not be regarded as a legal warranty of properties
or guarantee. In the interest of further technical developments, we reserve the right to make design changes.

EUROPE (EMEA): +44 (0)1582 723633 THE AMERICAS: +1 800 835 7075 ASIA-PACIFIC: +65 6 645 9888
enquiry@mtl-inst.com csinfo@mtl-inst.com sales.mtlsing@cooperindustries.com EPSx513 Rev3 210513

You might also like