W100G/W100GM/W150/W150G/W150GM. Otherwise, BT-WUC1U/
WUC1L or devices may be damaged.
• Do not use BT-WUC14 in combination with devices other than
BT-W100/W100G/W100GM/W150/W150G/W150GM. Otherwise,
BT-WUC14 or devices may be damaged.
• Do not charge batteries other than BT-WB1 on BT-WCG14.
Otherwise, BT-WCG14 or other rechargeable batteries may be
NOTICE
Communication unit, damaged.
• When charging only on BT-WCG14 without using BT-WUC1U/
Charging unit WUC1L/WUC14, note that charging performance of backup battery
may deteriorate because the backup battery is repeatedly charged/
BT-WUC1U/WUC1L
discharged.
• Use an AC power supply cord that coincides the shape of plug
used in each country. Also, check that the cord is compliant with
regulations and standards in each country.
Safety Precautions
General cautions
• Do not use this product for the purpose of protecting a human
AC adaptor connection terminal
body or a part of human body.
WARNING • This product is not intended for use as an explosion-proof product.
Do not use this product in a hazardous location and/or potentially
explosive atmosphere. If dirt or dust is attached, contact failure may occur on the battery/
charging/communication terminals. This may cause charging function
• Take appropriate safety measures to avoid any damage in unlikely NOTICE to deteriorate and instantaneous interruption.
CAUTION
event of malfunction. Make sure that waste textile is not attached to the battery/charging/
communication terminals when cleaning.
• Do not modify this product or use it in any way other than
NOTICE described in the specifications. Otherwise, the functions and
performance cannot be guaranteed.
1
Checking the Package
2 Insert BT-W100/W100G/W100GM/W150/W150G/W150GM
to BT-WUC1U/WUC1L.
When opening the package, check the following items are all included. The operation status LED will light in red, showing
If there is something missing, product failure or damage, contact your nearest KEYENCE charging is in progress.
sales office. The LED will light in green when charging is complete.
BT-WUC1U
BT-WUC1U main unit...1 AC adaptor USB cable...1 Instruction Manual...1
(OP-87722)...1
If the operation status LED blinks in red, check the possible causes as
Point follows.
• Abnormality of rechargeable battery pack
Replace with a normal rechargeable battery pack.
• Surrounding temperature is too high or too low.
Charge in a temperature environment of 0 to +40°C.
BT-WUC1L
Charging method using BT-WUC14
BT-WUC1L main unit...1 AC adaptor Instruction Manual...1
Use this method when charging up to 4 units of BT-W100/W100G/W100GM/W150/
(OP-87722)...1
W150G/W150GM at the same time.
Required charging time from fully discharge to full battery power is
Point approx. 6 hours in Charging mode 1 and 4.5 hours in Charging mode 2
and 3 (at room temperature).
BT-WCG14
BT-WCG14 main unit...1
Use the dedicated AC adaptor for BT-WUC14. Using a different AC adaptor
AC adaptor Instruction Manual...1 NOTICE may cause product failure, resulting in poor operation performance.
(OP-87722)...1
2 Insert BT-W100/W100G/W100GM/W150/W150G/
W150GM to BT-WUC14.
The operation status LED will light in red, showing
charging is in progress.
The LED will light in green when charging is
complete.
If the operation status LED blinks in red, check the possible causes as
Charging the rechargeable battery pack Point follows.
• Abnormality of rechargeable battery pack
Replace with a normal rechargeable battery pack.
Charge it in a temperature environment of 0 to 40°C. If it is charged in • Surrounding temperature is too high or too low.
NOTICE temperature environments other than this, charging efficiency may Charge in a temperature environment of 0 to +40°C.
deteriorate and battery leakage may result.
Charging method using BT-WCG14
Use this method when charging up to 4 units of rechargeable battery pack (BT-WB1) at
Use BT-WUC1U/WUC1L/WUC14/WCG14 for charging.
the same time.
• When charging only one unit, use BT-WUC1U/WUC1L.
• When charging 1 to 4 units at the same time, use BT-WUC14. Required charging time from fully discharge to full battery power is
Point
• When charging 1 to 4 units of BT-WB1 at the same time, use BT-WCG14. approx. 5 hours.
Charging method using BT-WUC1U/WUC1L Do not charge batteries other than BT-WB1 with BT-WCG14.
Otherwise, BT-WCG14 or other rechargeable batteries may be
Required charging time from fully discharge to full battery power is damaged.
Point approx. 6 hours in Charging mode 1 and 4.5 hours in Charging mode 2 When charging on BT-WCG14 only without using BT-WUC1U/WUC1L/
NOTICE
and 3 (at room temperature). WUC14, note that charging performance of backup battery may
deteriorate because the backup battery is repeatedly charged/
Do not use BT-WUC1U/WUC1L with devices other than BT-W100/ discharged.
NOTICE W100G/W100GM/W150/W150G/W150GM. Otherwise, BT-WUC1U/
WUC1L or devices may be damaged.
1 Set the AC adaptor to BT-WCG14 and
connect to the outlet.
1 Set the AC adaptor to Set the AC adaptor cable along with the
BT-WUC1U/WUC1L and connect slit on the side from which the cable is
to the outlet. pulled out.
2
2 Put the flat surface of BT-WB1 to the back and BT-WCG14
face the charging terminal part down.
Item Specifications
3 Push down the BT-WB1 to the bottom of
Model BT-WCG14
the charging slot of BT-WCG14 and push it
back. Charging method Constant current and constant voltage method
Charging part
4 The charging LED will light in red, Charging time Approx. 5.0 hours (at room temperature)
showing charging is in progress. The 2-color LED (red: charging, green: charging
Charging status LED
LED will light in green when charging is complete. complete)
If the charging LED blinks in red, the rechargeable battery pack is Surrounding air
0 to +40°C (No freezing)
Point
abnormal. Replace with a normal rechargeable battery pack. temperature
Surrounding air
20 to 85%RH (No condensation)
Environment humidity
Specifications resistance Storage ambient
-20 to +60°C (No freezing)
temperature
BT-WUC1U
Storage ambient
Item Specifications 20 to 85%RH (No condensation)
humidity
Model BT-WUC1U EMI VCCI Class A
USB2.0 Full Speed (host) Dimensions 162 x 130.1 x 50.1mm
Communication Interface
USB2.0 Full Speed (device) Weight 390g
Surrounding air temperature 0 to +40°C (No freezing) Input 100 to 240 VAC, 50/60 Hz, 30 to 40 VA
Surrounding air humidity 20 to 85%RH (No condensation) Dedicated AC
Environment adaptor Output 12 VDC, 1.5 A maximum
resistance Storage ambient temperature -20 to +60°C (No freezing) specifications Dimensions 80.6 x 50 x 31mm (excluding the cable)
(OP-87722)
Storage ambient humidity 20 to 85%RH (No condensation) Weight approx. 150g (excluding the AC cable)
EMI VCCI Class A
Model BT-WUC1L
Model BT-WUC14
Surrounding air
0 to +40°C (No freezing)
temperature
Storage ambient
20 to 85%RH (No condensation)
humidity
158 (20)
EMI VCCI Class A
3
AC adaptor for BT-WUC1U/BT-WUC1L/BT-WCG14 (OP-87722)
WARRANTIES AND DISCLAIMERS
1530 80.6 1900 45.5
(1) KEYENCE warrants the Products to be free of defects in materials and workmanship
(47) for a period of one (1) year from the date of shipment. If any models or samples
were shown to Buyer, such models or samples were used merely to illustrate the
general type and quality of the Products and not to represent that the Products
φ5.5
S01
31
improper installation, improper interfacing, improper repair, unauthorized
modification, misapplication and mishandling, such as exposure to excessive
current, heat, coldness, moisture, vibration or outdoors air. Components which wear
AC adaptor for BT-WUC14 are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They
51 28
13 are only suggestions, and it is Buyer's responsibility to ascertain the fitness of the
29 Products for Buyer’s intended use. KEYENCE will not be responsible for any
damages that may result from the use of the Products.
34 (3) The Products and any samples ("Products/Samples") supplied to Buyer are not to
be used internally in humans, for human transportation, as safety devices or fail-safe
Cable length: 1.8 m systems, unless their written specifications state otherwise. Should any Products/
Samples be used in such a manner or misused in any way, KEYENCE assumes no
responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE
17 harmless from any liability or damage whatsoever arising out of any misuse of the
Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS,
IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT
125 LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY
RIGHTS, ARE EXPRESSLY DISCLAIMED.
IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE
TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL,
PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT
(40) LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS
INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA,
Cable length: 1.8 m
LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY
MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY
TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED
ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR
DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions,
some of the foregoing warranty disclaimers or damage limitations may not apply.
*BT-WUC14 can be used only in Japan.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered to a third
party, Buyer must provide such third party with a copy of this document, all
specifications, manuals, catalogs, leaflets and written information provided to Buyer
pertaining to the Products/Samples.
E 1101-3
2013
12419E 1063-1 96M12419