ALSTOM
Structural steelwork DIN
Design and construction
Amendment Al 18800-1/A1
ICS 91.080.10
Appendix B
Ultimate limit state analysis for straightforward cases
Where the elastic-elastic method (cf. subclause 7.5.2) is used for ultimate limit state analysis, analyses to DIN 18800-2,
DIN 18 800-3 and DIN 18 800-4 are not required and the plastic capacity of Cross section is not utilized as permitted in items
(749) and (750), the limit Stresses ~a,~ and ~a,~ in equations (33) to (35) of item (747) may be increased by IO %.
NOTE 1: Exemption from the analysis as specified in DIN 18 800-2 presupposes that the criteria set out in items (739)
and (740) are satisfied, i.e. analysis according to second Order theory and the verification of lateral-torsional buckling
are not required.
NOTE 2: Exemption from the analysis as specified in DIN 18800-3 presupposes that the grenz (blr) values given in
tables 12 and 13 are compiied with.
NOTE 3: Exemption from the analysis as specified in DIN 18800-4 presupposes that the grenz (cllr) values given in
table 14 are complied with.