Construction
Close-coupled peripheral pumps (regenerative pumps) with
turbine impeller.
T, TP: version with pump casing and lantern bracket in cast iron.
B-T, B-TP: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).
Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials.
For increasing network pressure (follow local specifications).
For the reduced dimensions, these pumps are very well suitable
to be mounted in cooling and air-conditioning machines and
equipments, circulation, boiler feed.
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40 °C.
Total suction lift up to 7 m.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
T, TP: three-phase 230/400 V ± 10% up to 3 kW;
400/690 V ± 10% from 4 to 7,5 kW;
TM, TPM: single-phase 230 V ± 10% with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Materials Protection IP 54.
Components T, TP B-T, B-TP Classification scheme IE3 for three-phase motors from 0,75 kW.
Pump casing
Lantern bracket
Cast iron
GJL 200 EN 1561
Bronze
G-Cu Sn 10 EN 1982
Constructed in accordance with: EN 60034-1; EN 60034-30.
EN 60335-1, EN 60335-2-41.
19
Casing cover Cast iron Bronze
GJL 200 EN 1561 G-Cu Sn 10 EN 1982 Special features on request
Brass P- Cu Zn Pb 40 2 UNI 5705 for T 61-65-70, B-T 61-70 - Other voltages.
Impeller Brass P- Cu Zn 40 Pb 2 UNI 5705 - Frequency 60 Hz (as per 60 Hz data sheet).
Bronze G-Cu Sn 10 EN 1982 for T 125, TP 132-132R - Protection IP 55.
Shaft Cr-Ni steel AISI 303 - Special mechanical seal.
T 76, Tp 80-100 Cr-Ni-Mo steel
Chrome steel AISI 430 AISI 316
- Higher or lower liquid or ambient temperatures.
T 61-65-70-100-125, Tp 78-132-132R - Construction with bearing bracket.
Mechanical seal Carbon - Ceramic - NBR
0 U.S. g.p.m. 5 10 15 20 25
TP 132
160
TP 100 TP 132R 500
H
m ft
T 125
120 400
T 100
TP 80 300
80
200
40
T 76 100
TP 78 T 61 T 65 T 70
0 0
0 3
m /h 1 2 3 4 5 6
0 Q l/min 20 40 60 80 100
72.853
179
T, TP Peripheral Pumps
Q
3~ 230V 400V 1~ 230V P1 P2
m3/h 0,06 0,12 0,24 0,38 0,48 0,6 0,75 1 1,2 1,5 1,89 2,4 3 3,6 4,2 4,8 5,4 6
65 h2
160 182
108 h1
8 63 10 71
4.93.227
7 22 4.93.218
7 22
80 80 100
93 90 112
96 122
106 134
T 61E: kg 6,3
DN1 DN2 mm kg
B- T 61E: kg 6,5 TYPE
TIPO
ISO 228 a1 fM h2 h1 a T B-T
T 65E: kg 7,3
B- T 65E: kg 7,5 T 70/B B-T 70/B G 1 G 1 24 278 50 121 63 12 12,4
TP 78/A B-TP 78/A G 1/2 G 1/2 22 276 24 127 56 8,2 8,8
fM
a1 a
DN2 DN1 DN2
h2
H
h1
HA HS
4.93.093
K AA
w B A
BB AB
mm kg
DN1 DN2
TIPO
TYPE
ISO 228 a1 fM HS h2 h1 H BB B AB A AA K a w HA T, TP B-TP
T 76/A – G 11/4 G 11/4 26 338 80 56 136 208 117 100 155 125 30 9 80 105 10 18,4 -
T 100/A – G 11/4 G 11/4 32 410 90 59 161 226 152 125 180 140 40 9,5 95 121 12 32,5 -
T 125/B – G 11/4 G 11/4 32 470 90 75 170 226 152 125 180 140 40 9,5 90 195 12 39,5 -
TP 80E B-TP 80E G 3/4 G 3/4 27 332 80 35 135 208 117 100 155 125 30 9 60 104 10 16,4 16,8
TP 100/B – G 3/4 G 3/4 27 387 80 38 142 208 117 100 155 125 30 9 65 113 10 23,2 -
TP 132R/A – 53,6 -
G 11/4 G 11/4 42 485 112 70 202 272 180 140 230 190 50 11,5 100 183 14
TP 132/A – 58,5 -
180
T, TP Peripheral Pumps
Hm
30
H ft
H ft
80
80
20
60 20
60
40 40
10 10
20 20
0 0 0 0
3 3
0 Q m /h 0.5 1 1.5 2 2.5 0 Q m /h 1 2 3
0 l/min 8 12 16 20 24 28 32 36 40 0 l/min 10 20 30 40 50
0 l/s 0.1 0.2 0.3 0.4 0.5 0.6 0 l/s 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0.4 0.6 0.8
0.5
0.3 0.4 0.6
0.4
P kW
P kW
P HP
P HP
0.3
0.2 0.4
0.2 0.2
0.1 0.2
0.1
0 0 0 0
6 8 25
18
19
NPSH m
NPSH m
5 6 20
NPSH ft
NPSH ft
4 13 15
4
3 10
8 2
2 5
1 72.136
3 0 72.137
0
0 Q m3/h 0.5 1 1.5 2 2.5 0 Q m3/h 1 2 3
60
Ø 71 T 70 200
Ø 76 T 76
60 200
50
40
Hm
Hm
H ft
H ft
40
30 100
100
20
20
10
0 0 0 0
0 3 1 2 3 4 0 3 1 2 3 4
Q m /h Q m /h
0 l/min 10 20 30 40 50 60 0 l/min 10 20 30 40 50 60
0 l/s 0.2 0.4 0.6 0.8 1 0 l/s 0.2 0.4 0.6 0.8 1
1.0 1.6
1.2 2
0.8
1.0 1.2
P kW
0.6
P kW
0.8
P HP
P HP
0.8 1
0.4 0.6
0.4 0.4
0.2
0.2
0 0 0 0
5 4
15
NPSH m
NPSH m
4 3 10
NPSH ft
NPSH ft
3 10
2
2 5
5 1
1
0 0 0 0
72.138 72.139
0 Q m3/h 1 2 3 4 0 Q m3/h 1 2 3 4
181
T, TP Peripheral Pumps
60 200 80
Hm
Hm
H ft
H ft
160
40 60 200
120
80
20 40
40 100
0 0 20
3 3
0
Q m /h 0.2 0.4 0.6 0.8 1 1.2 0
Q m /h 0.5 1 1.5 2
0 l/min 4 6 8 10 12 14 16 18 20 0 l/min 5 10 15 20 25 30
0 l/s 0.1 0.2 0.3 0 l/s 0.1 0.2 0.3 0.4 0.5
0.5 1.0
0.6 1.2
0.4 0.8
0.5 1.0
P kW
P kW
P HP
0.2 0.3 0.4 0.6
0.2 0.4
0.1 0.2
0.1 0.2
0 0 0 0
5 5 16
15
NPSH m
NPSH m
4 4
12
NPSH ft
NPSH ft
3 10 3
8
2 2
5
1 1 4
0 0 0 0
72.145 72.141
0 Q m3/h 0.2 0.4 0.6 0.8 1 1.2 0 Q m3/h 0.5 1 1.5 2
600 400
TP 100 120
T 100
Ø 100
110
150 500
Ø 100
H ft
100
Hm
Hm
H ft
400 90 300
100 80
300
70
60 200 60 200
0 3 0.5 1 1.5 2 2.5 0 3 1 2 3 4 5
Q m /h Q m /h
0 l/min 10 20 30 40 0 l/min 20 30 40 50 60 70 80
0 l/s 0.1 0.2 0.3 0.4 0.5 0.6 0 l/s 0.2 0.4 0.6 0.8 1 1.2
3 4.0 5
3.5 6
4
P kW
3.0
P HP
P HP
P kW
5
2
2.5
3 4
2.0
1.5 3
1 2
5
6 20
NPSH m
NPSH m
14
NPSH ft
NPSH ft
15 4
4 12
10 10
2 3
5 8
0 0 2 6
0 0.5 1 1.5 2 72.142 2.5 0 1 2 3 4 72.140 5
Q m3/h Q m3/h
182
T, TP Peripheral Pumps
T 125
600 TP 132
TP 132R
300 1000
150 500
H ft
Hm
Hm
H ft
Ø 124 400
200
100 TP 132 Ø 132
300 TP 132R Ø 126 500
100
200
50 60 200
3 3
0 1 2 3 4 5 0
Q m /h Q m /h 1 2 3 4 5 6 7
0 l/min 20 30 40 50 60 70 80 0 l/min 20 40 60 80 100
0 l/s 0.2 0.4 0.6 0.8 1 1.2 0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
7 16
20
6 8 16
10
P kW
P kW
5
P HP
P HP
12
6 TP 132
4 TP 132R
8
3 4 4
2 0 0
10 10
30 30
19
NPSH m
NPSH m
8 8
NPSH ft
NPSH ft
6 20
6 20
4
4 10
10 2
2 0 0
72.143 72.144
0 Q m3/h 1 2 3 4 5 0 Q m3/h 1 2 3 4 5 6 7
183
T, TP Peripheral Pumps
Features
Range
The high number of pumps in the range can meet the widest range of services
required by the user.
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows T-TP series pumps to be selected
for use with different types of liquids.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, provi-
ding high reliability under all operating conditions.
Optimized hydraulics
The pump hydraulics are designed to ensure high performance and consistency
of performance.
184