Professional Documents
Culture Documents
Domestic use
Civil use
Industrial use
GUARANTEE
CERTIFICATIONS
2 years subject to terms and conditions
Company with management system certified DNV
ISO 9001: QUALITY
375
110
350
100 325
300
90
275
80
250
70
225
Head H (metres) 4
2CP32/210
2CP32/200 2CP40/180 2CP40/200
200
60
2CP25/14 175
50
150
2CP25/16
40
125
30 100
75
20
50
10
25
0 0
0 50 100 150 200 250 300 350 400 450 l/min
0 5 10 15 20 25 m³/h
Flow rate Q 4
2CP
GENERAL CATALOGUE 60 | 60 Hz
Hz | 111
2CP 25/14
0 5 10 15 20 25 30US g.p.m.
0 5 10 15 20 25
Imp g.p.m.
70 feet
2CP25/14A
65
25
200
60 30
33
55
2CP25/14B
50 η = 35%
Head H (metres) 4
150
45
H (feet)
35
36
40 33
37
35
36
30 100
35
25 30
20
15 50
10
12
2CP25/14
NPSH (metres)
10
30
NPSH (feet)
8
6 20
4
10
2
0 0
2
2CP25/14A
Absorbed power P2 (kW)
1.5 2
2CP25/14B
P2 (HP)
1
1
0.5
0 0
0 10 20 30 40 50 60 70 80 90 100 110 l/min
0 1 2 3 4 5 6 7 m³/h
Flow rate Q 4
MODEL POWER (P2) m³/h 0 1.2 1.8 2.4 3.0 3.6 4.2 4.8 5.4 6.0
Q
Single-phase Three-phase kW HP l/min 0 20 30 40 50 60 70 80 90 100
2CPm 25/14B 2CP 25/14B 1.1 1.5 54 52 50 47.5 44.5 41 37 32.5 27.5 22
IE3 H metres
2CPm 25/14A 2CP 25/14A 1.5 2 67 65 63 60.5 57.5 54 49.5 44.5 39 32
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
70 2CP25/16A
34
38 200
60
2CP25/16B 41
Head H (metres) 4
43
50 η = 44%
H (feet)
2CP25/16C
43
150
44.5
40 41
44 38
30 100
20
50
10
8
A
NPSH (metres)
B 20
6
NPSH (feet)
C
4
10
2
0 0
2.5
Absorbed power P2 (kW)
A 3
2.0
B
P2 (HP)
1.5 2
C
1.0
1
0.5
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 l/min
0 1 2 3 4 5 6 7 8 9 10 m³/h
Flow rate Q 4
MODEL POWER (P2) m³/h 0 1.2 1.8 2.4 3.0 3.6 4.2 4.8 5.4 6.0 6.6 7.2 8.4 9.6
Q
Single-phase Three-phase kW HP l/min 0 20 30 40 50 60 70 80 90 100 110 120 140 160
2CPm 25/16C 2CP 25/16C 1.1 1.5 47 46 45 44 42.5 40.5 38.5 36 33.5 30.5 27.5 24
2CPm 25/16B 2CP 25/16B 1.5 2 IE3 H metres 58 56 55 54 53 51 49.5 47.5 45.5 43 40 37 30
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
2CP 25/16
GENERAL CATALOGUE | 60 Hz
60 Hz | 113
2CP 32/200
CHARACTERISTIC CURVES AND PERFORMANCE DATA 60 Hz n= 3450 min-1 HS= 0 m
0 10 20 30 40 50 60 US g.p.m.
0 10 20 30 40 50 Imp g.p.m.
90 feet
2CP32/200B
80
36 250
40
70 43
2CP32/200C
Head H (metres) 4
45
46
H (feet)
46.5
200
60 η = 47%
46.5
46
50 46.5
45 150
40 43
30 100
4
NPSH (metres)
3 10
NPSH (feet)
2
5
1
0 0
5
B
Absorbed power P2 (kW)
6
4
5
C
3
P2 (HP)
4
3
2
2
1
1
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 l/min
0 5 10 15 m³/h
Flow rate Q 4
MODEL POWER (P2) m³/h 0 2.4 3.6 4.8 6 7.2 8.4 9.6 10.8 12 13.5 15
Q
Three-phase kW HP l/min 0 40 60 80 100 120 140 160 180 200 225 250
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
2CP32/210A
110 30
35
38
350
40
42
100
43
2CP32/210B
Head H (metres) 4
η = 44% 300
90
H (feet)
43
80
42
250
42.5
70
40
60 200
50
6
NPSH (metres)
5
15
NPSH (feet)
4
3 10
2
5
1
0 0
8
10
Absorbed power P2 (kW)
A
7
6 B 8
P2 (HP)
5
6
4
3 4
2
0 20 40 60 80 100 120 140 160 180 200 220 240 260 l/min
0 5 10 15 m³/h
Flow rate Q 4
MODEL POWER (P2) m³/h 0 2.4 3.6 4.8 6 7.2 8.4 9.6 10.8 12 13.5 15
Q
Three-phase kW HP l/min 0 40 60 80 100 120 140 160 180 200 225 250
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
2CP 32/210
GENERAL CATALOGUE | 60 Hz
60 Hz | 115
2CP 40/180
CHARACTERISTIC CURVES AND PERFORMANCE DATA 60 Hz n= 3450 min-1 HS= 0 m
0 25 50 75 100 125
US g.p.m.
0 25 50 75 100 Imp g.p.m.
100 feet
2CP40/180A 300
90 45
50
53
80 2CP40/180B 55
56
250
Head H (metres) 4
η = 56.5%
70
H (feet)
2CP40/180C
56 55
200
60
53
55 50
50
150
40
30 100
8
NPSH (metres)
6 20
NPSH (feet)
4
10
2
0 0
8
10
A
Absorbed power P2 (kW)
7
6 8
B
5
P2 (HP)
6
C
4
3 4
2
2
1
0 0
0 50 100 150 200 250 300 350 400 450 l/min
0 5 10 15 20 25 m³/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
110
2CP40/200A 350
40
44
47
50
100
52
2CP40/200B
Head H (metres) 4
54
55 300
90
H (feet)
η = 55.5%
80 55
55
250
54
70
52
200
60
50
5
15
NPSH (metres)
NPSH (feet)
3 10
2
5
1
0 0
11
14
Absorbed power P2 (kW)
10 A
9 12
B
8
P2 (HP)
10
7
6 8
5
6
4
3 4
0 50 100 150 200 250 300 350 400 450 l/min
0 5 10 15 20 25 m³/h
Flow rate Q 4
MODEL POWER (P2) m³/h 0 6 8.4 10.8 13.2 15.6 18 20.4 22.8 25.2 27
Q
Three-phase kW HP l/min 0 100 140 180 220 260 300 340 380 420 450
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
2CP 40/200
GENERAL CATALOGUE | 60 Hz
60 Hz | 117
2CP
POS. COMPONENT CONSTRUCTION CHARACTERISTICS
1 SUCTION BODY Cast iron complete with threaded suction port in compliance with ISO 228/1
2 DELIVERY BODY Cast iron complete with threaded suction port in compliance with ISO 228/1
3 IMPELLERS Brass
4 MOTOR SHAFT Stainless steel AISI 431
5 MECHANICAL SEAL Pump Seal Shaft Materials
Model Model Diameter Stationary ring Rotational ring Elastomer
2CP 25/14
FN-18 Ø 18 mm Graphite Ceramic NBR
2CP 25/16
2CP 32/200 FN-20 Ø 20 mm Graphite Ceramic NBR
2CP 32/210
FN-24 Ø 24 mm Graphite Ceramic NBR
2CP 40/180
2CP 40/200 FN-32 NU Ø 32 mm Graphite Ceramic NBR
8 ELECTRIC MOTOR 2CPm: single-phase 220 V - 60 Hz with thermal overload protector incorporated into the winding.
2CP: three-phase 220/380 V - 60 Hz or 220/440 V - 60 Hz
➠ The three-phase pumps are fitted with high performance motors in class IE3 (IEC 60034-30-1)
– Insulation: class F
– Protection: IP X4
6 7 6
3 5 4 8
f t
a
DN2
h2
h3
DN1
h1
w s
n2
ABSORPTION PALLETIZATION
2CP
GENERAL CATALOGUE 60 | 60 Hz
Hz | 119