Professional Documents
Culture Documents
Industrial use
CERTIFICATIONS
Company with management system certified DNV
ISO 9001: QUALITY
ISO 14001: ENVIRONMENT AND SAFETY
134
PERFORMANCE RANGE 50 Hz n= 2900 rpm
30 40 50 100 200 300 400 500 1000 US g.p.m.
30 40 50 100 200 300 400 500 1000 Imp g.p.m.
110 feet
100
90 F 300
80 50/250 250
70
32/250 40/250 65/250 80/250 100/250 200
60
50
150
32/200 40/200 50/200 65/200 80/200 100/200
Head H (metres) 4
40
30 100
32/160 50/160 65/160 80/160 90
25 80
40/160 70
20
100/160 60
50/125 65/125
15 50
40/125
40
10
9 30
8
100 150 200 300 400 500 1000 1500 2000 3000 4000 5000 l/min
135
F32/160
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
25 50 75 100 US g.p.m.
25 50 75 100 Imp g.p.m.
40 feet
125
F32/160A
51
35 55
57
58
30 F32/160B 60 100
Head H (metres) 4
= 62%
H (feet)
60
25 F32/160C 58
75
57
20 55
51
15 50
MEI 0.40
10
6
NPSH (metres)
15
NPSH (feet)
4
10
2
5
0 0
3.5 4
Absorbed power P2 (kW)
A
3
2.5
P2 (HP)
B
2
C
1.5
1
0.5
50 100 150 200 250 300 350 400 450 l/min
5 10 15 20 25 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
136
F32/200
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 50 100 US g.p.m.
0 50 100 Imp g.p.m.
60 feet
F32/200A
55 45
50 175
52
F32/200B 53
54
50 = 55%
Head H (metres) 4
150
45 F32/200C 54
H (feet)
40
125
35
54
100
30
MEI 0.40
25
8
NPSH (metres)
6 20
NPSH (feet)
4
10
2
0 0
7
A 9
Absorbed power P2 (kW)
6 8
B
7
5
P2 (HP)
6
C
4
5
3 4
3
2
0 50 100 150 200 250 300 350 400 450 500 550 l/min
0 5 10 15 20 25 30 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
137
F32/200H
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
25 50 75 US g.p.m.
25 50 Imp g.p.m.
60 feet
F32/200AH
55 40
43
45 175
48
50
50 51.5
Head H (metres) 4
= 53.5%
H (feet)
F32/200BH 150
45
40
125
35
8
NPSH (metres)
6 20
NPSH (feet)
4
10
2
0 0
5
6
Absorbed power P2 (kW)
AH
4
5
BH
3 4
P2 (HP)
3
2
2
1
1
0 0
50 100 150 200 250 300 l/min
5 10 15 20 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
138
F32/250
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
50 100 US g.p.m.
50 100 Imp g.p.m.
110 feet
350
100
F32/250A
36
300
40
90
F32/250B 42
43
Head H (metres) 4
44
80
H (feet)
F32/250C 250
= 45%
70
200
60
50
150
MEI 0.40
40
10 30
NPSH (metres)
NPSH (feet)
6 20
4
10
2
0 0
14
18
Absorbed power P2 (kW)
A
12 16
B 14
10
P2 (HP)
12
8 C
10
6 8
6
4
50 100 150 200 250 300 350 400 450 l/min
5 10 15 20 25 m/h
Flow rate Q 4
F 32/250A 15 20 98 97 96 94.5 92 89 85 80 74 70
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
139
F40/125
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 50 100 150 US g.p.m.
0 50 100 150 Imp g.p.m.
30 feet
90
F40/125A
55
25 60
80
64
66
68
F40/125B 70
20
= 69%
Head H (metres) 4
60
68
F40/125C
H (feet)
66
15 50
64
60
40
55
10
30
20
5
10
MEI 0.40
0 0
6
NPSH (metres)
NPSH (feet)
15
4
3 10
2
5
1
2.5
Absorbed power P2 (kW)
A 3
2
2.5
B
1.5 2
P2 (HP)
C 1.5
1,0
1
0.5
0.5
0 0
0 100 200 300 400 500 600 700 l/min
0 5 10 15 20 25 30 35 40 45 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
140
F40/160
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 50 100 150 US g.p.m.
0 50 100 150 Imp g.p.m.
45 feet
40
F40/160A 125
55
60
35 63
F40/160B 65
Head H (metres) 4
= 68% 100
30
H (feet)
65
F40/160C
63
25 60
75
20
15 50
MEI 0.40
10
8
NPSH (metres)
6 20
NPSH (feet)
4
10
2
0 0
5
Absorbed power P2 (kW)
6
4 A
5
B
3 4
P2 (HP)
C 3
2
2
1
1
0 0
0 100 200 300 400 500 600 700 l/min
0 5 10 15 20 25 30 35 40 45 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
141
F40/200
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 50 100 150 US g.p.m.
0 50 100 150 Imp g.p.m.
60 feet
F40/200A
55 50
55
57
200
59
50
F40/200B 63
= 64%
Head H (metres) 4
45
63
H (feet)
40
150
59
35
57
55
30 54
100
25
MEI 0.40
20
6
NPSH (metres)
15
NPSH (feet)
4
10
2
5
0 0
8
A 10
Absorbed power P2 (kW)
6 B 8
P2 (HP)
5
6
4
3 4
2
0 100 200 300 400 500 600 700 l/min
0 5 10 15 20 25 30 35 40 45 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
142
F40/250
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 50 100 150 US g.p.m.
0 50 100 150 Imp g.p.m.
100 feet
300
90 F40/250A
42
46
48
80 50
Head H (metres) 4
52 250
= 53%
H (feet)
F40/250B
70
F40/250C
200
60
50
150
MEI 0.40
40
8
NPSH (metres)
20
NPSH (feet)
6
4
10
2
0 0
18
Absorbed power P2 (kW)
16 A
20
14
B
P2 (HP)
12
15
C
10
8 10
4
0 100 200 300 400 500 600 700 l/min
0 5 10 15 20 25 30 35 40 45 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
143
F50/125
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
100 200 300 US g.p.m.
100 200 Imp g.p.m.
25 feet
F50/125A
69
70
F50/125B 70
73
20
= 75%
60
F50/125C
Head H (metres) 4
73
H (feet)
71
70 50
15
65
40
10
30
20
MEI 0.40
5
6
NPSH (metres)
15
NPSH (feet)
4
10
2
5
0 0
4.5 6
Absorbed power P2 (kW)
A
5
3.5
P2 (HP)
B
4
2.5
C 3
1.5 2
200 300 400 500 600 700 800 900 1000 1100 1200 l/min
20 30 40 50 60 70 m/h
Flow rate Q 4
Fm 50/125C F 50/125C 2.2 3 18.5 17.5 17 16.5 15.5 14.8 13.5 12 10.5 8.2 6
F 50/125B 3 4 H metres 21.5 20.7 20 19.5 18.8 17.8 16.5 15 13.5 11.2 9
F 50/125A 4 5.5 24.5 23.5 23 22.5 21.8 20.8 19.5 18.3 16.8 15 13
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
144
F50/160
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
100 200 300 US g.p.m.
100 200 Imp g.p.m.
40 feet
F50/160A
62
64 120
67
35
70
70
30
Head H (metres) 4
100
F50/160C 67
71
H (feet)
25 90
64
80
20
62
70
15
60
MEI 0.40 50
10
6
NPSH (metres)
15
NPSH (feet)
4
10
2
5
0 0
8
10
Absorbed power P2 (kW)
A
7
9
6
8
P2 (HP)
B
5 7
C
4 6
5
3
4
2
200 300 400 500 600 700 800 900 1000 1100 1200 l/min
20 30 40 50 60 70 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
145
F50/200
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
F50/200AR
F50/200A
= 70%
Head H (metres) 4
F50/200B
H (feet)
F50/200C
MEI 0.40
8 25
NPSH (metres)
NPSH (feet)
6 20
15
4
10
2 5
0 0
Absorbed power P2 (kW)
P2 (HP)
Flow rate Q 4
F 50/200C 11 15 44 44 44 42 39 36 33 30
F 50/200B 15 20 52 52 52 50 47 44 40 38
H metres
F 50/200A 18.5 25 61 61 60.5 60 57 54 50 48 45
F 50/200AR 22 30 69 69 68.5 68 65 62 58 56 53
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
146
F50/250
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
100
F50/250AR
90
F50/250A = 61%
80
F50/250B
70
Head H (metres) 4
H (feet)
60 F50/250C
F50/250D
50
40
30
MEI 0.40
20
8 25
NPSH (metres)
NPSH (feet)
6 20
15
4
10
2 5
0 0
25
Absorbed power P2 (kW)
20
P2 (HP)
15
10
Flow rate Q 4
F 50/250C 11 15 59 59 58 57 54 51 47 42
F 50/250B 15 20 H metres 72 72 71 70 69 67 65 62 59
F 50/250A 18.5 25 85 85 84 83 82 80 78 76 73
F 50/250AR 22 30 95 95 94 93 92 90 88 86 83
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
147
F65/125
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
200 300 400 500 600 US g.p.m.
100 200 300 400 500 Imp g.p.m.
25 feet
F65/125A 70 73
75
80
= 81% 70
20
F65/125B 80 60
Head H (metres) 4
F65/125C
H (feet)
50
15 75
73
40
10
30
20
MEI 0.40
5
6
NPSH (metres)
15
NPSH (feet)
4
10
2
5
0 0
9 12
Absorbed power P2 (kW)
8 A
10
7
P2 (HP)
6 B 8
5
C 6
4
3 4
2
400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 l/min
25 50 75 100 125 150 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
148
F65/160
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
200 300 400 500 600 US g.p.m.
100 200 300 400 500 Imp g.p.m.
45 feet
140
F65/160A
40 72
130
78
80
F65/160B
120
Head H (metres) 4
= 81%
35
H (feet)
80 110
F65/160C
79
100
30
90
25
80
70
MEI 0.40
20
8
NPSH (metres)
20
NPSH (feet)
6
4
10
2
0 0
16
A
Absorbed power P2 (kW)
20
14
12
P2 (HP)
B 15
C
10
8
10
6
400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 l/min
25 50 75 100 125 150 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
149
F65/200
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 100 200 300 400 500 600 US g.p.m.
0 100 200 300 400 500 Imp g.p.m.
60
F65/200AR
60
70
55
75
175
80
F65/200A
50 81
Head H (metres) 4
= 82%
150
45 F65/200B
H (feet)
81
40
125
35
100
30
MEI 0.40
25
25
8
NPSH (metres)
20
NPSH (feet)
6
15
4 10
2 5
0 0
25
Absorbed power P2 (kW)
30
20
25
P2 (HP)
15 20
15
10
10
5
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 l/min
0 25 50 75 100 125 150 m/h
Flow rate Q 4
MODEL POWER (P2) m/h 12 36 48 60 72 84 96 108 120 132 144 150 156
Q
Three-phase kW HP l/min 200 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2500 2600
F 65/200B 15 20 44 43.5 43.3 43 42.5 41.5 40 38.5 36.5 34 30.5
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
150
F65/250
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 100 200 300 400 500 600 700 US g.p.m.
0 100 200 300 400 500 600 Imp g.p.m.
100 feet
F65/250A 58
65
300
90 70
F65/250B
72
275
Head H (metres) 4
= 73%
80
F65/250C
H (feet)
250
72
70
70
225
200
60
175
MEI 0.40
50
8
NPSH (metres)
6 20
NPSH (feet)
4
10
2
0 0
45 60
A
Absorbed power P2 (kW)
40
B 50
35
30 C 40
P2 (HP)
25
30
20
15 20
10
10
5
0 500 1000 1500 2000 2500 l/min
0 50 100 150 m/h
Flow rate Q 4
F 65/250A 45 60 95 95 94 92 88 82.5 75 71 68
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
151
F80/160
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
45
F80/160A
40
70
125
76
F80/160B 81
35
= 84%
F80/160C 100
Head H (metres) 4
30 81
H (feet)
76 78
F80/160D
25
75
20
70
15 50
10
25
MEI 0.40
5
NPSH (metres)
NPSH (feet)
Absorbed power P2 (kW)
P2 (HP)
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
152
F80/200
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 250 500 750 1000 US g.p.m.
0 250 500 750 1000 Imp g.p.m.
70 feet
F80/200A 60
68
200
60 70
72
75
F80/200B
Head H (metres) 4
79
175
= 82%
H (feet)
50
79
150
75
72
40
125
NPSH (feet)
6 20
4
10
2
0 0
40
50
Absorbed power P2 (kW)
30 B
40
P2 (HP)
30
20
20
10
0 500 1000 1500 2000 2500 3000 3500 4000 4500 l/min
0 50 100 150 200 250 m/h
Flow rate Q 4
F 80/200B 30 40 56 56 54 49 41 34.5
H metres
F 80/200A 37 50 62 62 61 57 50 45.5 40
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
153
F80/250
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 250 500 750 1000 US g.p.m.
0 250 500 750 1000 Imp g.p.m.
100 feet
300
90 F80/250A
70
75 275
Head H (metres) 4
80 76
F80/250B
H (feet)
= 77% 250
75
70
225
71
69
200
60
175
MEI 0.40
50
8
NPSH (metres)
6 20
NPSH (feet)
4
10
2
0 0
60 80
A
Absorbed power P2 (kW)
50
B 60
40
P2 (HP)
30 40
20
20
10
0 500 1000 1500 2000 2500 3000 3500 4000 4500 l/min
0 50 100 150 200 250 m/h
Flow rate Q 4
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
154
F100/160
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 500 1000 1500 US g.p.m.
0 500 1000 Imp g.p.m.
40 feet
125
F100/160A-N
60
35 65
70
F100/160B-N 73
76
100
30 78
F100/160C-N
Head H (metres) 4
= 80%
H (feet)
25 78
76 75
73
20
70
65
15 50
60
MEI 0.40
10
10 30
NPSH (metres)
NPSH (feet)
6 20
4
10
2
0 0
25
Absorbed power P2 (kW)
30
A
20
P2 (HP)
25
B
15 C 20
15
10
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 l/min
0 50 100 150 200 250 300 350 400 m/h
Flow rate Q 4
MODEL POWER (P2) m/h 60 120 180 240 270 300 330 360
Q
Three-phase kW HP l/min 1000 2000 3000 4000 4500 5000 5500 6000
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
155
F100/200
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 250 500 750 1000 1250 US g.p.m.
0 250 500 750 1000 Imp g.p.m.
70 feet
65
F100/200A
60
71 200
60
75
F100/200B
79
55 80.5
Head H (metres) 4
175
F100/200C = 81%
50
H (feet)
80.5
150
45 80.5 79
75
40 79
125
35
100
30 71
MEI 0.40
25
10 30
NPSH (metres)
NPSH (feet)
6 20
4
10
2
0 0
50
Absorbed power P2 (kW)
A 60
40
B 50
P2 (HP)
30 C 40
30
20
20
10
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 l/min
0 50 100 150 200 250 300 m/h
Flow rate Q 4
MODEL POWER (P2) m/h 0 50 100 150 200 250 279 294 300 315
Q
Three-phase kW HP l/min 0 833 1667 2500 3333 4167 4650 4900 5000 5250
F 100/200C 30 40 51 51 50 47 41.5 34 28
F 100/200B 37 50 H metres 57 57 56 53 48 41 36 33
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
156
F100/250
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 250 500 750 1000 1250 1500 US g.p.m.
0 250 500 750 1000 1250 Imp g.p.m.
100 feet
F100/250A 300
90 65
72
75
78 275
80
= 80%
Head H (metres) 4
F100/250B 250
H (feet)
78
70
225
75
= 79.5%
71 200
60
175
50
150
MEI 0.40
40
10 30
NPSH (metres)
NPSH (feet)
6 20
4
10
2
0 0
80 A
100
Absorbed power P2 (kW)
70
60 80
B
P2 (HP)
50
60
40
30 40
20
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 l/min
0 50 100 150 200 250 300 350 m/h
Flow rate Q 4
MODEL POWER (P2) m/h 48 96 150 180 210 240 300 309 345
Q
Three-phase kW HP l/min 800 1600 2500 3000 3500 4000 5000 5150 5750
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
157
F
POS. COMPONENT CONSTRUCTION CHARACTERISTICS
1 PUMP BODY Cast iron complete with flanged suction and delivery ports
2a BODY BACKPLATE Cast iron for F32/160, F32/200, F40/125, F40/160, F40/200, F50/125, F50/160, F65/125
2b MOTOR BRACKET Cast iron for F32/250, F40/250, F50/200, F50/250, F65/160, F65/200, F65/250,
F80/160, F80/200, F80/250, F100/160, F100/200, F100/250
3 IMPELLER Brass for F32/160, F32/200, F40/125, F40/160, F40/200, F50/125, F50/160
Cast iron for F32/250, F40/250, F50/200, F50/250, F65/125, F65/160, F65/200, F65/250,
F80/160, F80/200, F80/250, F100/160, F100/200, F100/250
4 MOTOR SHAFT Stainless steel EN 10088-3 - 1.4104
5 MECHANICAL SEAL Pump Seal Shaft Materials
Model Model Diameter Stationary ring Rotational ring Elastomer
F32/160, F40/125, F40/160, 50/125 FN-20 20 mm Graphite Ceramic NBR
F32/200, F40/200, F50/160, F65/125 FN-24 24 mm Graphite Ceramic NBR
F50/200, F65/160, F65/200, F80/160,
FN-32 NU 32 mm Graphite Ceramic NBR
F100/160
F32/250, F40/250, F50/250 FN-38 38 mm Graphite Ceramic NBR
F65/250, F80/200, F80/250B, F100/200 FN-40 NU 40 mm Graphite Ceramic NBR
F80/250A, F100/250 FH-45 NU 45 mm Graphite Ceramic NBR
6 BEARINGS Pump Model Pump Model
F32/160C F40/160C F 32/250 F50/200
F32/160B F50/125C 6206 ZZ-C3 / 6204 ZZ F40/250 F65/160
F40/125 6310 ZZ-C3 / 6308 ZZ-C3
F50/250 F80/160
Fm32/160B F32/160A F65/200 F100/160
Fm40/160C F40/160B 6206 ZZ-C3 / 6205 ZZ F65/250 F80/200
Fm50/125C F50/125B 6312 ZZ-C3 / 6212 ZZ-C3
F80/250B F100/200
F40/160A
6306 ZZ-C3 / 6206 ZZ-C3 F80/250A
F50/125A 6314 ZZ-C3 / 6314 ZZ-C3
F100/250
F32/200 F40/200
6307 ZZ-C3 / 6206 ZZ-C3
F50/160 F65/125
7 CAPACITOR Pump Capacitance
Single-phase (230 V or 240 V)
Fm32/160C 45 F - 450 VL
Fm32/160B 70 F - 450 VL
Fm40/125C 31.5 F - 450 VL
Fm40/125B 45 F - 450 VL
Fm40/160C 70 F - 450 VL
Fm50/125C 70 F - 450 VL
8 ELECTRIC MOTOR Fm: single-phase 230 V - 50 Hz with thermal overload protector incorporated into the winding (up to 1.5 kW)
F: three-phase 230/400 V - 50 Hz up to 4 kW
400/690 V - 50 Hz from 5.5 to 75 kW
The three-phase pumps are fitted with high performance motors up to
P2=1.1kW in class IE2 and from P2=1.5kW in class IE3 (IEC 60034-30)
Insulation: class F Protection: IP X5
6 7 6 6 6
1 3 2a 5 4 8 1 3 5 2b 4 8
158
ABSORPTION
MODEL VOLTAGE
Single-phase 230 V 240 V
Fm 32/160C 11.0 A 10.0 A
Fm 32/160B 15.0 A 13.8 A
Fm 40/125C 8.6 A 7.8 A
Fm 40/125B 15.0 A 13.8 A
Fm 40/160C 15.0 A 13.8 A
Fm 50/125C 15.0 A 13.8 A
159
F
DIMENSIONS AND WEIGHT
f n
a
DN2
h2
h
DN1
h1
s
w1 w2 n1
n2
MODEL DIMENSIONS mm kg
Single-phase Three-phase DN1 DN2 a f h h1 h2 n n1 n2 w1 w2 s 1~ 3~
Fm 32/160C F 32/160C 412 32.7 32.1
Fm 32/160B F 32/160B 448/412 292 132 160 242 37.5 33.4
F 32/160A 448 37.4
F 32/200C 469 46.4
80 190 240 35 35
F 32/200B 48.4
515
F 32/200A 50 32 340 160 180 270 56.9
F 32/200BH 42.4
469
F 32/200AH 46.4
F 32/250C 100.0
606
F 32/250B 100 405 180 225 330 250 320 47.5 47.5 102.0
F 32/250A 701 119.8
Fm 40/125C F 40/125C 31.5 29.5
Fm 40/125B F 40/125B 421 252 112 140 244 160 210 33.0 31.5
F 40/125A 33.0
80
Fm 40/160C F 40/160C 448/412 37.6 33.5
35 35
F 40/160B 448 292 132 160 240 190 240 37.5
F 40/160A 65 40 465 43.6
F 40/200B 54.0
535 340 160 180 275 212 265
F 40/200A 60.0
F 40/250C 100.0
606
F 40/250B 405 180 225 328 250 320 47.5 47.5 102.0
F 40/250A 701 119.8
Fm 50/125C F 50/125C 465/431 37.3 33.2
F 50/125B 465 292 132 160 242 190 240 37.2
F 50/125A 484 43.3
14
F 50/160C 489 48.0
F 50/160B 340 180 269 52.5
535 35 35
F 50/160A 56.4
F 50/200C 616 160 212 265 97.7
F 50/200B 65 50 114.0
711 360 200 316
F 50/200A 126.5
F 50/200AR 100 743 140.3
F 50/250D 101.3
606
F 50/250C 103.3
F 50/250B 405 180 225 337 250 320 120.4
701
F 50/250A 134.3
F 50/250AR 733 147.4
F 65/125C 511 53.5
F 65/125B 340 180 291 56.8
557
F 65/125A 63.3
160 212 280
F 65/160C 98.3
621 47.5 47.5
F 65/160B 80 65 360 200 300 99.3
F 65/160A 716 114.3
F 65/200B 120.3
719
F 65/200A 340 132.9
F 65/200AR 751 144.4
F 80/160D 652 405 180 225 250 320 103.8
F 80/160C 115.6
100 80 747 330
F 80/160B 133.1
F 80/160A 125 779 144.6
F 100/160C-N 126.3
758
F 100/160B-N 125 100 480 200 280 362 280 360 60 60 18 136.3
F 100/160A-N 790 151.3
160
DIMENSIONS AND WEIGHT
f
a
DN2
n
h2
h
DN1
h1
s n1
h3
w m n2
MODEL DIMENSIONS mm kg
Three-phase DN1 DN2 a f h h1 h2 h3 n n1 n2 w m s 3~
F 65/250C 796 201.3
F 65/250B 80 65 100 847 450 15 369 201.3
F 65/250A 847 250 219.3
200 318 360 269.5 305 18.5
F 80/200B 824 201.6
430 25 360
F 80/200A 875 201.6
100 80
F 80/250B 872 480 12 380 234.5
280
F 80/250A 125 1015 620 250 55 490 400 490 294 350 24 539.0
F 100/200C 824 225.3
F 100/200B 875 480 200 280 0 391 318 360 269.5 305 18.5 225.3
F 100/200A 125 100 875 233.3
F 100/250B 539.3
140 1036 620 250 280 45 490 400 490 300 350 24
F 100/250A 539.3
F
K
D
DN
K
D
161