Duration: 4 Days
Overview
This course provides you with an understanding of the hazards involved
in using electrical equipment in potentially explosive atmospheres. It is
based on the international IEC79 series of standards that are now
replacing the older national
standards. Installation utilising Explosion-Protected (Ex) equipment can
be expensive to design, install and operate. The wider approaches
described in these standards can significantly reduce costs whilst
maintaining plant safety.
The associated terminology and its correct use are explained
throughout the workshop. It covers area classification, selection of
explosion protected electrical apparatus as well as describing how
protection is achieved and maintained in line with these international
requirements. Standards require that engineering staff and their
management are trained effectively and safely in hazardous areas and
this workshop is designed to help fulfil that need.
Course Objectives:
You will be able to:
Demonstrate a good understanding of the terminology used with
hazardous areas
Understand the hazards of using electrical equipment in the
presence of flammable gasses vapors and dusts
Understand the basis of explosion protection to IEC standards
Assist in hazardous area classification
Detail the types of apparatus that can be used in a given hazardous
area
Design and install safe working systems in hazardous areas
Demonstrate a good understanding of the basic hazards associated
with electricity near flammable gases and vapours
Explain the types of equipment that can be used
Understand safety and operational aspects of hazardous areas
Understand system limitations in using hazardous areas protection
Detail the key areas of the national codes of practice
Understand the basics of explosion protection to IEC standards
Explosion Consequences
Nature of hazards
Definition of hazardous areas
Flammability concepts
Ignition sources
Properties of gases, vapours, mists and dusts
Introduction to types of protection
CLASSIFICATION SYSTEMS
Source of release
Area cloassification into zones
Equipment (apparatus) grouping
Temperature classification and ambient rating
Summenry of principles of EX protection
Equipment protection levels
TYPES OF PROTECTION
Definitions
Principles
Application of Flameproof Ex d
Application of Increased Safety Ex e
Application of Pressurization Ex p
Application of Intrinsic Safety Ex i
Application of Non-Incendive Ex n
Application of Oil Filling Ex o
Application of Powder Filling Ex q
Encapsulation Ex m
Basic Principles
Earthing Requirements
Static Protection
Lightening Protection
Noise and Interference control
Requirements for IS systems
System earthing approach
Planned Maintenance
Use of tools
Procedures
Safe methods
Test equipment suitability
Authorities
Marking and identification
Equipment certification
System certification
System descriptive documentation (for Ex i)
ATEX DIRECTIVES
Practical session
Videos of explosions to show the effectiveness of the protection principles covered in
the course
Hazardous areas are places where concentrations of flammable gases, vapors, or dusts
occur; hence, there is a risk of explosions if inadequate safety measures and work habits
are carried out. Plants and factories have many locations that can be classified
as hazardous areas, and thus need suitably-prepared equipment in those areas.
This course is intended to equip delegates with the technical knowledge to understand
what international certification and industrial standards are required for different zones,
and apply practical skills to real-life situations.
COURSE OUTLINE
INTRODUCTION AND OVERVIEW
Explosion- Definition
Types of Hazards
EXPLOSION PROTECTION
Limits of flammability
Principle of protection
APPARATUS GROUPING
Temperature classification
Zones of Protection
CLASSIFICATION OF AREA
Design Objective
Zones of Protection
Mathematical Approach
Explosion Containment
Ex d Gap Construction
MESG- Definition
Pressure Pilling
Maintenance Procedure
Mechanical Ignitions
Thermal Ignitions
Simple Apparatus
Safety Description of Apparatus
Definitions
Construction requirements
Principles of application
Scope
Structural Earthing
Parasitic Capacitance
Functions of CENELEC
This course provides a comprehensive technical approach to hazardous areas. It explains the
subject of explosionprotection applied to electrical equipment in such areas. The course offers
detailed explanations of the principles involved, the techniques used, the management structures and
requirements to comply with the harmonized international standardsthat are now in place. Where
potentially flammable atmospheres are encountered in industrial processes, area classification is
mandatory as part of a risk assessment for the management of health and safety; the issues are
examined by providing the opportunity to apply this process and understand the importance and extent
of the co-operation of the disciplines involved. Requirements of inspection and maintenance are
examined to show the importance of their effectiveness once the correct installation has been properly
achieved, and to enable management to form a structured and effective regime to assure safety.
This course would also be appropriate for supervisors and managers, with the emphasis on outlining the
management responsibility and enabling them to complement and accommodate the needs of technical
staff beneath them. It is a common problem that technical staff are trained in what needs to be done but
their management does not appreciate this or understand it. This course will address these
shortcomings
Course Objectives
Upon completion of this workshop you will be able to:
Use correct hazardous areas terminology and definitions
Explain the responsibilities of hazardous area owners and equipment suppliers
Explain how apparatus is made safe and suitable for use in hazardous areas
Provide an understanding of the different types of protection
Understand simple area classification schemes
Examine different approaches for selection of types of protection
Compare techniques used for power and instrumentation applications
Explain how marking and identification of such apparatus is applied
Understand the requirements for maintenance of such apparatus
Understand the requirements for inspection in hazardous area
Discuss how work permits systems must be adopted for hazardous area working
Discuss and compare the advantages and disadvantages of different types of protection in
given applications
Compare certification and approval concepts
Effectively communicate with others on such safety issues
COURSE OUTLINE
Fire triangle
Flammability characteristics
Ignition sources
Apparatus grouping
MODULE 3: AREA CLASSIFICATION THEORY
Objectives
Terminology and definitions
Sources of release and ventilation
Zoning
Presentation, communication and monitoring
Responsibilities
Types of protection suitability
MODULE 4: AREA CLASSIFICATION PRACTICE
Flameproof
Theory of operation
Flamepath joint types
Dimensions and condition
Apparatus and component certification
MODULE 6: EX I & SYSTEMS
Intrinsic safety
Simple apparatus
Apparatus and system concepts
Interfaces
Apparatus matching
Descriptive system documentation
MODULE 7: EX E AND EX N
Increased safety
Limitations of use
Insulation and connection integrity
Enclosure requirements
Non-incendive
The difference in approach
MODULE 8: EX TYPES: P, O, Q, M AND S
Features of these other types of protection
Pressurisation and purging, oil immersion, sand-filling and encapsulation.
Special protection
Combined protection types
MODULE 9: INSTALLATION
General requirements
Information flow
Cabling requirements
Electrical protection
Earthing and bonding
Specific requirements for different types of Protection
MODULE 10: INSPECTION
General requirements
Periodicity and grade
Scheduling
Maintenance
Responsibilities
Testing and fault-finding issues
MODULE 11: CERTIFICATION AND MARKING
Summary of certification
Marking of older apparatus
Types of certificate and information contained
Conditions placed on the use of apparatus
Multiple certification techniques and benefits
MODULE 12: EUROPEAN ATEX REQUIREMENTS
ابتدا التفكير في موضوع (حماية االجهزة الكهربائية في المناطق الخطرة) بعد اكتشاف الكهرباء
وبالتحديد عند دخول الكهرباء واستخداماتها في مناجم الفحم الحجري في اوروبا السيما مع وجود
خطر تراكم غاز الميثان وغبار الفحم الحجري فيها .حيث حدث انفجارين في منجمين للفحم في
بريطانيا اوائل القرن المنصرم بسبب جرس كهربائي داخل المنجم كانت اسالكه بالية مما ادى الى
حصول شرارة كهربائية وانفجار ومن ثم حريق .
عند التخطيط لبناء مجمع كمياوي أو بتروكمياوي جديد يبرز السؤال على كيفية تحديد المناطق
الخطرة في المجمع ومنذ المراحل األولى للتخطيط والتصميم ،يمكن اإلطالع على العديد من األمثلة
للمناطق الخطرة والمفصلة في كتيبات التعليمات الفنية للمناطق الخطرة ويعطى لهذه المناطق
أهمية خاصة لدى شركات التأمين على المجمعات الكمياوية والبتروكمياوية مما يستوجب تحديدها
بدقة ومراعات ضوابطها منذ مراحل التخطيط األولى ألي مشروع ،وبذلك يتم تحديد وبكل دقة
األماكن العامة الصناعية في المجمع من المناطق الخطرة ويتم تثبيتها على الخرائط والمصادقة
عليها من جهات متخصصة ومخولة وفي ذلك أهمية على سالمة األفراد والمعدات أضافة الى
أنعكاسها على كلفة المشروع.
وفي المعامل الصناعية الكبيرة مثل المصافي والعمليات الكيماوية فان التعامل مع كميات كبيرة من
السوائل والغازات القابلة لالنفجار يخلق خطر التسرب .وفي بعض الحاالت فان الغاز والبخار القابل
لالنفجار والتراب يكون موجودا على طول الوقت او لفترة طويلة .مناطق اخرى ربما تحتوي كميات او
تراكيز خطرة من المواد القابلة لالشتعال فقط في حالة وجود اضطراب العمليات او تدهور المعدات
بين فترات الصيانة او خالل حادث معين .
لذا فان المصافي والمعامل الكيمياوية تصنف الى مناطق اعتمادا على خطر تسرب غاز او بخار او
غبار قابل لالشتعال .وتعرف على انها تقسيمات ( )Divisionsاو مناطق (. )Zones
اما عملية تحديد نوع الخطر في هذه المناطق فيدعى بالتصنيف ( )Classوالتصنيف الثانوي االخر
والذي يعبر عن مواصفات المادة كمياويا فهو المجموعة ( . )Groupباالضافة الى ذلك تم تقسيم او
تصنيف االجهزة بحسب الحرارة الداخلية للجهاز وعالقتها بدرجة اتقاد الغازات واالبخرة المحيطة
بالجهاز .وايضا يوجد تصنيف مهم اخر له عالقة بمقدار او طبيعة تحمل الجهاز للضروف الجوية
المحيطة من رطوبة وامطار او فيضانات .
-1التقسيم حسب المناطق ()Divisions and Zones
بشكل عام قسمت المناطق الخطرة في الصناعة النفطية على أساس عاملين اساسين هما تواتر
أو توقع وجود خليط للغازات قابلة لالشتعال أو لالنفجار وأمد بقاء وجود خليط الغازات القابلة
لالشتعال أو لالنفجار في كل مرة .
حسـب المفهـوم أعـاله قسمـت ألمانيا والدول األوربية المناطق الخطرة الى ثالث مناطق (Zone 0,
)Zone 1 & Zone 2بينـما قسمت في الواليـات المتحدة األمريكية الى قسمين هما (& Division 1
. )Division 2
· المنطقة رقم (صفر) ( : )Zone 0تعرف بأنها المنطقة التي يتواجد فيها خليط غازي قابل لالشتعال
بصورة مستمرة أو بصورة طويلة نسبيا (.اكثر من 1000ساعة/سنة) .
· المنطقة رقم ( : )Zone 1( )1تعرف بأنها المنطقة التي من المحتمل أن يوجد فيها خليط غازي
قابل لالشتعال في حاالت التشغيل االعتيادية ولفترات طويلة (من 1000-10ساعة/سنة) .
· منطقة رقم ( : )Zone 2( )2تعرف بأنها المنطقة التي من غير المحتمل أن يوجد فيها خليط غازي
قابل لالشتعال في حاالت التشغيل االعتيادية ،وان حدث ووجد مثل ذلك الخليط الغازي فسيكون
ذلك لفترة قصيرة جدا 10(.ساعات/سنة).
تعرف المواد الهيدروكاربونية التي تتعامل بها الصناعة النفطية بأنها تلك المشمولة بالفئة واحد (
. )Class Iوان هذه الفئة تتعامل فقط مع المخاطر الناتجة عن الغازات واألبخرة ورذاذ مواد
الهيدروكاربونية القابلة لالشتعال التي تقع ضمن هذه الفئة وال تتعامل مع الغبار Dustsاو الغزول او
األلياف والمواد المتطايرة Fibers & Flyingsحيث أن لها تغطية خاصة بالمعايير والمواصفات العالمية
كونها مشمولة بالفئة اثنين والفئة ثالثة Class II & Class IIIحسب المواصفات NECاألمريكية ،في
حين أن موضوعنا يغطي الفئة واحد فقط . Class I
على كل حال مع قليل من االختالف بالتعريف فان القسم ( )Division 1( )1المحدد في المعايير
األمريكية يشمل ويحوي المنطقتين رقم (صفر) ورقم ( )Zone 0 & Zone 1( )1حسب المعايير
األوربية واأللمانية .
-3التصنيف حسب المجاميع (: )Group
االستيلين :المجموعة Group A
الهيدروجين :المجموعة Group B
االيثيلين :المجموعة Group C
البروبان :المجموعة Group D
الغبار المعدني :المجموعة Group E
غبار الكربون :المجموعة Group F
الدقيق او الطحين وغبار الشعير والحبوب االخرى :المجموعة Group G
أن أهمية تصنيف المعدات حسب مجاميع الغازات التي تستخدم في مناطق تواجدها تكمن في
تحديد األبعاد المناسبة ألطوال مسارات اللهب ( )Flame Pathsوالفجوات ( )Gapsلكافة الفتحات
الموجودة في المعدة ،بحيث تسمح للغازات المتفجرة داخل المحتوى بالتبريد بشكل كافي من
خالل تمددها وخروجها من تلك الفتحات بحيث ال تشكل خطرا او مصدرا التقاد الغازات واألبخرة
المتواجدة في المحيط الخارجي .
لقد صنفت درجة الحرارة القصوى للسطوح الى ست فئات من T1الى T6بدرجات حرارة من 450
الى 85درجة مئوية كما في المواصفات األوربية والبريطانية و IECفي حين جزئت فئة الحرارة T2
الى أربع فئات أخرى هي Aو Bو Cو Dكما جزئت فئة الحرارة T3الى ثالث فئـات أخرى هي Aو
Bو Cوجزئت فئة الحرارة T4الى فئة أخرى هي Aحسب المواصفات األمريكية وكما مبين بالجدول
.إن التصنيف الحراري يؤشر درجة الحرارة القصوى لكل سطح غير محمي عند التشغيل االعتيادي
لألجهزة والمعدات مع األخذ بزيادة الحمل المسموح بها بنظر االعتبار .جرت العادة تحديد الزيادة
بدرجة حرارة األسطح %80من درجة الحرارة القصوى كعامل آمان .
أن الدرجة القصوى لألسطح محسوبة على أساس درجة حرارة المحيط Ambient Temperatureبـ
40درجة مئوية فعند استعمال األجهزة والمعدات بدرجة حرارة للمحيط أعلى من 40درجة مئوية
فيجب أن يؤخذ ذلك بنظر االعتبار .
وحسب مواصفات أل VDEفي ألمانيا استعملت خمس فئـات لدرجـة االتقـاد رمـز لها بـ ()G1 to G5
وهذا حتى الوقت الذي اعتمدت فيه المعايير والمواصفات األوربية وهي معادلة لفئات الدرجات (T1
– T5