You are on page 1of 4

T647 并口更改楼层映射分解图

Floor indication change process

工具:microUSB 线、电脑。Prepare tool : microUS wire、computer



动作 备注

Action Note
step

准 备 一 根
microUSB 线
1
Prepare one :
microUS wire

先将 microUSB
一端接电脑一
端接显示器,然
后再给显示器
供电。
2 Connect
microUSB
terminal to COP
screen, then
then power on
COP screen.
等待 10-30 秒电
脑会有 2 个 U
盘弹出,如果没
有弹出重复上
面 2 的操作,界
面文件存放在
内存稍大的磁
盘里面(120M)
Wait for 10-30
seconds, the
3 computer will
have two U
disks pop up, if
not, repeat the
above 2
operations, the
interface file is
stored in the
disk with a
larger memory
(120M)

打开内存稍大
的 U 盘
(120M) ,找到
TGUS_TF 目录
下 floor.txt 文件
Open a USB
4 flash drive with
a bit more
memory (120M)
and locate the
floor-txt file in
the TGUS_TF
directory
打开 floor.txt
文件。文件中
等号左边为物
理楼层,右边
为实际楼层,
可根据实际要
求更改。
Open the floor-
txt file. The left
side of the
5 medium number
of the file is the
physical floor,
and the right
side is the
actual floor,
which can be
changed
according to
actual
requirements.

更改完成后,保
存 floor.txt 文件
When the
6
changes are
complete, save
the floor.txt file.

弹出 U 盘,再
拔掉 microUSB
线

7
Eject the USB
flash drive and
unplug the
microUSB cable
使用并口程序,界面文件中必须含有 floor.txt 文件,否则会卡在文件传输界面,无法进入
注意点 正常界面
8
Note : To use the parallel port program, the interface file must contain the floor-txt file, otherwise it will
be stuck in the file transfer interface and cannot enter the normal interface