You are on page 1of 7

Job No Sheet No Rev

1
Software licensed to Part
CONNECTED User: User is not logged in to CONNECTION Client.
Job Title MAROL BRIDGE Ref

By Date02-Nov-23 Chd

Client BRIHAN MUMBAI MUNICIPAL CORPORATION File MAROL BRIDGE.STD Date/Time 02-Nov-2023 12:33

Job Information
Engineer Checked Approved

Name:
Date: 02-Nov-23

Project ID
Project Name

Structure Type SPACE FRAME

Number of Nodes 52 Highest Node 52


Number of Elements 50 Highest Beam 72
Number of Plates 10 Highest Plate 32

Number of Basic Load Cases 8


Number of Combination Load Cases 6

Included in this printout are data for:


All The Whole Structure

Included in this printout are results for load cases:


Type L/C Name

Primary 1 IRC: SLS CLASS A LOADING N11: DISP Y -VE


Primary 2 IRC: SLS CLASS A LOADING N14: DISP Y -VE
Primary 3 IRC: SLS CLASS A LOADING N9: REACT FY +VE
Primary 4 IRC: SLS CLASS A LOADING N10: REACT FY +VE
Primary 5 IRC: SLS CLASS A LOADING N12: REACT FY +VE
Primary 6 IRC: SLS CLASS A LOADING N13: REACT FY +VE
Primary 7 DL
Primary 8 FOOTPATH LL
Combination 9 COMBINATION LOAD CASE 9
Combination 10 COMBINATION LOAD CASE 10
Combination 11 COMBINATION LOAD CASE 11
Combination 12 COMBINATION LOAD CASE 12
Combination 13 COMBINATION LOAD CASE 13
Combination 14 COMBINATION LOAD CASE 14

Print Time/Date: 02/11/2023 12:36 STAAD.Pro CONNECT Edition 22.12.00.142 Print Run 1 of 7
Job No Sheet No Rev
2
Software licensed to Part
CONNECTED User: User is not logged in to CONNECTION Client.
Job Title MAROL BRIDGE Ref

By Date02-Nov-23 Chd

Client BRIHAN MUMBAI MUNICIPAL CORPORATION File MAROL BRIDGE.STD Date/Time 02-Nov-2023 12:33

Primary Load Cases


Number Name Type

1 IRC: SLS CLASS A LOADING N11: DISP Y -VE None


2 IRC: SLS CLASS A LOADING N14: DISP Y -VE None
3 IRC: SLS CLASS A LOADING N9: REACT FY +VENone
4 IRC: SLS CLASS A LOADING N10: REACT FY +VE
None
5 IRC: SLS CLASS A LOADING N12: REACT FY +VE
None
6 IRC: SLS CLASS A LOADING N13: REACT FY +VE
None
7 DL Dead
8 FOOTPATH LL Live

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

9 COMBINATION LOAD CASE 9 1 IRC: SLS CLASS A LOADING N11: DISP Y -VE 1.50
7 DL 1.50
8 FOOTPATH LL 1.50
10 COMBINATION LOAD CASE 10 2 IRC: SLS CLASS A LOADING N14: DISP Y -VE 1.50
7 DL 1.50
8 FOOTPATH LL 1.50
11 COMBINATION LOAD CASE 11 3 IRC: SLS CLASS A LOADING N9: REACT FY +VE1.50
7 DL 1.50
8 FOOTPATH LL 1.50
12 COMBINATION LOAD CASE 12 4 IRC: SLS CLASS A LOADING N10: REACT FY +VE
1.50
7 DL 1.50
8 FOOTPATH LL 1.50
13 COMBINATION LOAD CASE 13 5 IRC: SLS CLASS A LOADING N12: REACT FY +VE
1.50
7 DL 1.50
8 FOOTPATH LL 1.50
14 COMBINATION LOAD CASE 14 6 IRC: SLS CLASS A LOADING N13: REACT FY +VE
1.50
7 DL 1.50
8 FOOTPATH LL 1.50

1 IRC: SLS CLASS A LOADING N11: DISP Y -VE : Plate Loads


Plate Type Direction Fa Fb X1 Y1 X2 Y2
(m) (m) (m) (m)
24 PRE N/mm2 GY -0.456 - 0.761 -0.733 1.011 -0.233
PRE N/mm2 GY -0.456 - 0.761 1.067 1.011 1.567
25 PRE N/mm2 GY -0.456 - -0.739 -0.733 -0.489 -0.233
PRE N/mm2 GY -0.456 - -0.739 1.067 -0.489 1.567
26 PRE N/mm2 GY -0.456 - 0.761 -1.233 1.011 -0.733
PRE N/mm2 GY -0.456 - 0.761 0.567 1.011 1.067
27 PRE N/mm2 GY -0.456 - -0.739 -1.233 -0.489 -0.733
PRE N/mm2 GY -0.456 - -0.739 0.567 -0.489 1.067

Print Time/Date: 02/11/2023 12:36 STAAD.Pro CONNECT Edition 22.12.00.142 Print Run 2 of 7
Job No Sheet No Rev
3
Software licensed to Part
CONNECTED User: User is not logged in to CONNECTION Client.
Job Title MAROL BRIDGE Ref

By Date02-Nov-23 Chd

Client BRIHAN MUMBAI MUNICIPAL CORPORATION File MAROL BRIDGE.STD Date/Time 02-Nov-2023 12:33

2 IRC: SLS CLASS A LOADING N14: DISP Y -VE : Plate Loads


Plate Type Direction Fa Fb X1 Y1 X2 Y2
(m) (m) (m) (m)
26 PRE N/mm2 GY -0.456 - 0.761 -1.067 1.011 -0.567
PRE N/mm2 GY -0.456 - 0.761 0.733 1.011 1.233
27 PRE N/mm2 GY -0.456 - -0.739 -1.067 -0.489 -0.567
PRE N/mm2 GY -0.456 - -0.739 0.733 -0.489 1.233
28 PRE N/mm2 GY -0.456 - 0.761 -1.567 1.011 -1.067
PRE N/mm2 GY -0.456 - 0.761 0.233 1.011 0.733
29 PRE N/mm2 GY -0.456 - -0.739 -1.567 -0.489 -1.067
PRE N/mm2 GY -0.456 - -0.739 0.233 -0.489 0.733

3 IRC: SLS CLASS A LOADING N9: REACT FY +VE : Plate Loads


Plate Type Direction Fa Fb X1 Y1 X2 Y2
(m) (m) (m) (m)
24 PRE N/mm2 GY -0.456 - -1.300 -0.733 -1.201 -0.233
PRE N/mm2 GY -0.456 - -1.300 1.067 -1.201 1.567
PRE N/mm2 GY -0.456 - -0.351 -0.733 -0.101 -0.233
PRE N/mm2 GY -0.456 - -0.351 1.067 -0.101 1.567
26 PRE N/mm2 GY -0.456 - -1.300 -1.233 -1.201 -0.733
PRE N/mm2 GY -0.456 - -1.300 0.567 -1.201 1.067
PRE N/mm2 GY -0.456 - -0.351 -1.233 -0.101 -0.733
PRE N/mm2 GY -0.456 - -0.351 0.567 -0.101 1.067

4 IRC: SLS CLASS A LOADING N10: REACT FY +VE : Plate Loads


Plate Type Direction Fa Fb X1 Y1 X2 Y2
(m) (m) (m) (m)
25 PRE N/mm2 GY -0.456 - -0.332 -0.733 -0.082 -0.233
PRE N/mm2 GY -0.456 - -0.332 1.067 -0.082 1.567
PRE N/mm2 GY -0.456 - 0.768 -0.733 1.018 -0.233
PRE N/mm2 GY -0.456 - 0.768 1.067 1.018 1.567
27 PRE N/mm2 GY -0.456 - -0.332 -1.233 -0.082 -0.733
PRE N/mm2 GY -0.456 - -0.332 0.567 -0.082 1.067
PRE N/mm2 GY -0.456 - 0.768 -1.233 1.018 -0.733
PRE N/mm2 GY -0.456 - 0.768 0.567 1.018 1.067

Print Time/Date: 02/11/2023 12:36 STAAD.Pro CONNECT Edition 22.12.00.142 Print Run 3 of 7
Job No Sheet No Rev
4
Software licensed to Part
CONNECTED User: User is not logged in to CONNECTION Client.
Job Title MAROL BRIDGE Ref

By Date02-Nov-23 Chd

Client BRIHAN MUMBAI MUNICIPAL CORPORATION File MAROL BRIDGE.STD Date/Time 02-Nov-2023 12:33

5 IRC: SLS CLASS A LOADING N12: REACT FY +VE : Plate Loads


Plate Type Direction Fa Fb X1 Y1 X2 Y2
(m) (m) (m) (m)
26 PRE N/mm2 GY -0.456 - -1.300 -1.067 -1.201 -0.567
PRE N/mm2 GY -0.456 - -1.300 0.733 -1.201 1.233
PRE N/mm2 GY -0.456 - -0.351 -1.067 -0.101 -0.567
PRE N/mm2 GY -0.456 - -0.351 0.733 -0.101 1.233
28 PRE N/mm2 GY -0.456 - -1.300 -1.567 -1.201 -1.067
PRE N/mm2 GY -0.456 - -1.300 0.233 -1.201 0.733
PRE N/mm2 GY -0.456 - -0.351 -1.567 -0.101 -1.067
PRE N/mm2 GY -0.456 - -0.351 0.233 -0.101 0.733

6 IRC: SLS CLASS A LOADING N13: REACT FY +VE : Plate Loads


Plate Type Direction Fa Fb X1 Y1 X2 Y2
(m) (m) (m) (m)
27 PRE N/mm2 GY -0.456 - -0.332 -1.067 -0.082 -0.567
PRE N/mm2 GY -0.456 - -0.332 0.733 -0.082 1.233
PRE N/mm2 GY -0.456 - 0.768 -1.067 1.018 -0.567
PRE N/mm2 GY -0.456 - 0.768 0.733 1.018 1.233
29 PRE N/mm2 GY -0.456 - -0.332 -1.567 -0.082 -1.067
PRE N/mm2 GY -0.456 - -0.332 0.233 -0.082 0.733
PRE N/mm2 GY -0.456 - 0.768 -1.567 1.018 -1.067
PRE N/mm2 GY -0.456 - 0.768 0.233 1.018 0.733

7 DL : Selfweight
Direction Factor Assigned Geometry

Y -1.000 ALL

8 FOOTPATH LL : Plate Loads


Plate Type Direction Fa Fb X1 Y1 X2 Y2
(m) (m) (m) (m)
22 PRE N/mm2 GY -0.005 - - - - -
23 PRE N/mm2 GY -0.005 - - - - -
31 PRE N/mm2 GY -0.005 - - - - -
32 PRE N/mm2 GY -0.005 - - - - -

Print Time/Date: 02/11/2023 12:36 STAAD.Pro CONNECT Edition 22.12.00.142 Print Run 4 of 7
Job No Sheet No Rev
5
Software licensed to Part
CONNECTED User: User is not logged in to CONNECTION Client.
Job Title MAROL BRIDGE Ref

By Date02-Nov-23 Chd

Client BRIHAN MUMBAI MUNICIPAL CORPORATION File MAROL BRIDGE.STD Date/Time 02-Nov-2023 12:33

Beam Displacement Detail Summary


Displacements shown in italic indicate the presence of an offset
Beam L/C d X Y Z Resultant
(m) (mm) (mm) (mm) (mm)
Max X 34 12:COMBINATION LOAD0.600
CASE 120.552 -6.343 -0.033 6.367
Min X 33 11:COMBINATION LOAD0.900
CASE 11
-0.459 -5.726 0.006 5.744
Max Y 19 3:IRC: SLS CLASS A 1.500
LOADING N9:
-0.184
REACT FY +VE
-0.060 -0.050 0.200
Min Y 3 12:COMBINATION LOAD 0 CASE 120.498 -6.636 -0.056 6.655
Max Z 33 14:COMBINATION LOAD0.600
CASE 140.066 -4.509 0.116 4.511
Min Z 39 12:COMBINATION LOAD0.600
CASE 120.066 -4.509 -0.115 4.511
Max Rst 3 12:COMBINATION LOAD 0 CASE 120.498 -6.636 -0.056 6.655

Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kN-m) (kN-m) (kN-m)
Max FX 19 9:COMBINATION LOAD CASE 994.573
2.364 0.017 -23.834 -0.170 -5.849
Min FX 20 9:COMBINATION LOAD CASE 996.868
-2.361 -0.007 -25.255 0.221 6.583
Max FY 22 12:COMBINATION LOAD
-1.712
CASE111.369
12 -0.142 28.564 1.292 5.053
Min FY 38 8:FOOTPATH LL 0.071 1.868 0.000 0.000 -0.000 0.005
Max FZ 22 14:COMBINATION LOAD
-1.685
CASE104.945
14 0.150 -82.874 0.097 5.415
Min FZ 24 12:COMBINATION LOAD
-1.685
CASE104.945
12 -0.150 82.874 -0.097 5.415
Max MX 46 12:COMBINATION LOAD
-1.682
CASE101.386
12 -0.149 163.769 -0.023 0.568
Min MX 36 14:COMBINATION LOAD
-1.682
CASE101.386
14 0.149 -163.769 0.023 0.568
Max MY 39 10:COMBINATION LOAD
2.246
CASE 92.808
10 -0.012 -103.081 3.157 -0.516
Min MY 37 9:COMBINATION LOAD
2.246
CASE 992.808 0.012 103.081 -3.157 -0.516
Max MZ 20 12:COMBINATION LOAD
-1.804
CASE109.452
12 -0.138 -36.821 0.726 9.717
Min MZ 19 11:COMBINATION LOAD
1.606
CASE 11
99.337 -0.111 -32.248 -0.673 -8.245

Base Pressure Summary


Node L/C FX FY FZ
(N/mm2) (N/mm2) (N/mm2)
Max FX 19 1:IRC: SLS CLASS A LOADING
0 N11: DISP
0 Y -VE 0
Min FX 19 1:IRC: SLS CLASS A LOADING
0 N11: DISP
0 Y -VE 0
Max FY 19 1:IRC: SLS CLASS A LOADING
0 N11: DISP
0 Y -VE 0
Min FY 19 1:IRC: SLS CLASS A LOADING
0 N11: DISP
0 Y -VE 0
Max FZ 19 1:IRC: SLS CLASS A LOADING
0 N11: DISP
0 Y -VE 0
Min FZ 19 1:IRC: SLS CLASS A LOADING
0 N11: DISP
0 Y -VE 0

Print Time/Date: 02/11/2023 12:36 STAAD.Pro CONNECT Edition 22.12.00.142 Print Run 5 of 7
Job No Sheet No Rev
6
Software licensed to Part
CONNECTED User: User is not logged in to CONNECTION Client.
Job Title MAROL BRIDGE Ref

By Date02-Nov-23 Chd

Client BRIHAN MUMBAI MUNICIPAL CORPORATION File MAROL BRIDGE.STD Date/Time 02-Nov-2023 12:33

Statics Check Results


L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kN-m) (kN-m) (kN-m)
1:IRC: SLS CLASS A
Loads
LOADING N11: DISP Y -VE0 -456.000 0 2.58E+3 0 -1.25E+3
1:IRC: SLS CLASS A
Reactions
LOADING N11: DISP -0.000
Y -VE 456.000 0.000 -2.58E+3 0.000 1.25E+3
Difference -0.000 -0.000 0.000 0.000 0.000 -0.000
2:IRC: SLS CLASS A
Loads
LOADING N14: DISP Y -VE0 -456.000 0 4.26E+3 0 -1.25E+3
2:IRC: SLS CLASS A
Reactions
LOADING N14: DISP -0.000
Y -VE 456.000 -0.000 -4.26E+3 -0.000 1.25E+3
Difference -0.000 -0.000 -0.000 0.000 -0.000 -0.000
3:IRC: SLS CLASS A
Loads
LOADING N9: REACT FY +VE
0 -318.288 0 1.8E+3 0 -249.341
3:IRC: SLS CLASS A
Reactions
LOADING N9: REACT0.000
FY +VE 318.288 -0.000 -1.8E+3 -0.000 249.341
Difference 0.000 -0.000 -0.000 0.000 -0.000 -0.000
4:IRC: SLS CLASS A
Loads
LOADING N10: REACT FY0+VE -456.000 0 2.58E+3 0 -1.93E+3
4:IRC: SLS CLASS A
Reactions
LOADING N10: REACT-0.000
FY +VE 456.000 0.000 -2.58E+3 0.000 1.93E+3
Difference -0.000 -0.000 0.000 0.000 0.000 -0.000
5:IRC: SLS CLASS A
Loads
LOADING N12: REACT FY0+VE -318.288 0 2.97E+3 0 -249.341
5:IRC: SLS CLASS A
Reactions
LOADING N12: REACT 0.000
FY +VE 318.288 -0.000 -2.97E+3 0.000 249.341
Difference 0.000 -0.000 -0.000 0.000 0.000 -0.000
6:IRC: SLS CLASS A
Loads
LOADING N13: REACT FY0+VE -456.000 0 4.26E+3 0 -1.93E+3
6:IRC: SLS CLASS A
Reactions
LOADING N13: REACT-0.000
FY +VE 456.000 0.000 -4.26E+3 -0.000 1.93E+3
Difference -0.000 -0.000 0.000 0.000 -0.000 -0.000
7:DL Loads 0 -1.54E+3 0 11.5E+3 0 -4E+3
7:DL Reactions -0.000 1.54E+3 -0.000 -11.5E+3 -0.000 4E+3
Difference -0.000 -0.000 -0.000 0.000 -0.000 -0.000
8:FOOTPATH LL Loads 0 -78.000 0 585.000 0 -202.800
8:FOOTPATH LL Reactions -0.000 78.000 -0.000 -585.000 -0.000 202.800
Difference -0.000 -0.000 -0.000 -0.000 -0.000 -0.000

Print Time/Date: 02/11/2023 12:36 STAAD.Pro CONNECT Edition 22.12.00.142 Print Run 6 of 7
Job No Sheet No Rev
7
Software licensed to Part
CONNECTED User: User is not logged in to CONNECTION Client.
Job Title MAROL BRIDGE Ref

By Date02-Nov-23 Chd

Client BRIHAN MUMBAI MUNICIPAL CORPORATION File MAROL BRIDGE.STD Date/Time 02-Nov-2023 12:33

Max Absolute
N/mm2
<= 1.24
1.25
1.26
1.27
1.28
1.29
1.31
1.32
1.33
1.34
1.35
1.36
1.37
1.38
1.39
1.4
>= 1.41

Y
X
Z Load 0

Whole Structure (Input data was modified after picture taken)

3D Rendered View (Input data was modified after picture taken)

Print Time/Date: 02/11/2023 12:36 STAAD.Pro CONNECT Edition 22.12.00.142 Print Run 7 of 7