DEADLOADS:
Weight of Concrete : 24 kN/m3
Weight of Ceiling
Suspended Metal Lath and Gypsum Plaster : 0.48 kPa
Weight of Ext. Wall
6” CHB, plastered both faces : 2.73 kPa
4” CHB, plastered both faces : 2.11 kPa
Weight of Floor Fin. on Concrete slab
Ceramic or Quarry Tile (20mm)
on 13 mm mortar bed : 0.77 kPa
Weight of Railings : 0.75 kN/m
Others : (10% from total)
LIVE LOADS
Basic Floor Area = 1.90 kPa
Exterior Balconies = 2.90 kPa
ROOF LOADS
see attached Design of Truss
CONSTRUCTION OF
TWO(2)-STOREY
RESIDENTIAL BUILDING
Prepared by:
By Date05-Jan-19 Chd
PERSPECTIVE
Job Information
Engineer Checked Approved
Name:
Date: 05-Jan-19
Primary 1 EARTHQUAKE XA
Primary 2 EARTHQUAKE XB
Primary 3 EARTHQUAKE ZA
Primary 4 EARTHQUAKE ZB
Primary 5 DEAD LOAD
Primary 6 LIVE LOAD
Primary 7 ROOF LIVE LOAD
Combination 8 GENERATED ACI TABLE1 1
Combination 9 GENERATED ACI TABLE1 2
Combination 10 GENERATED ACI TABLE1 3
Combination 11 GENERATED ACI TABLE1 4
Combination 12 GENERATED ACI TABLE1 5
Combination 13 GENERATED ACI TABLE1 6
Combination 14 GENERATED ACI TABLE1 7
Combination 15 GENERATED ACI TABLE1 8
Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 8
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
4 1 5 2 6
76 77 78
16 16 17 17 18
85 86 87
28 31 29 32 30
94 95 96
40 46 41 47 42
Y X
52 61 53 62 54 Load 1
Z
79 165 80 168 81
19 18 71 12120 19 91 167 21
88 166 89 90
31 33 73 12332 34 33
97 98 99
43 48 44 49 45
106 107 108
65 169 86 170 80
Y X 55 63 83 135 56 64 57
Z
Load 1
136 132 134
84 137 81 133 82
Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 2 of 8
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
149 150
Y X 66 148 75
Z Load 1
ROOF FRAMING PLAN
Section Properties
Prop Section Area Iyy Izz J Material
(cm2) (cm4) (cm4) (cm4)
1 Rect 0.30x0.35 1.05E+3 107E+3 78.8E+3 153E+3 CONCRETE
2 Rect 0.30x0.30 900.000 67.5E+3 67.5E+3 114E+3 CONCRETE
3 Rect 0.30x0.25 750.000 39.1E+3 56.3E+3 77.5E+3 CONCRETE
4 Rect 0.25x0.25 625.000 32.6E+3 32.6E+3 54.9E+3 CONCRETE
5 Rect 0.35x0.25 875.000 45.6E+3 89.3E+3 102E+3 CONCRETE
6 Rect 0.25x0.45 1.12E+3 190E+3 58.6E+3 153E+3 CONCRETE
7 Rect 0.25x0.35 875.000 89.3E+3 45.6E+3 102E+3 CONCRETE
8 Rect 0.20x0.35 700.000 71.5E+3 23.3E+3 60E+3 CONCRETE
9 Rect 0.20x0.40 800.000 107E+3 26.7E+3 73.2E+3 CONCRETE
10 Rect 0.25x0.35 875.000 89.3E+3 45.6E+3 102E+3 CONCRETE
11 Rect 0.20x0.30 600.000 45E+3 20E+3 47E+3 CONCRETE
Materials
Mat Name E Density
(kN/mm2) (kg/m3) (/°C)
1 STEEL 205.000 0.300 7.83E+3 12E -6
2 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
3 ALUMINUM 68.948 0.330 2.71E+3 23E -6
4 CONCRETE 21.718 0.170 2.4E+3 10E -6
Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 3 of 8
Job No Sheet No Rev
4
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Supports
Node X Y Z rX rY rZ
(kN/mm) (kN/mm) (kN/mm) (kN-m/deg) (kN-m/deg) (kN-m/deg)
1 Fixed Fixed Fixed Fixed Fixed Fixed
2 Fixed Fixed Fixed Fixed Fixed Fixed
3 Fixed Fixed Fixed Fixed Fixed Fixed
13 Fixed Fixed Fixed Fixed Fixed Fixed
14 Fixed Fixed Fixed Fixed Fixed Fixed
15 Fixed Fixed Fixed Fixed Fixed Fixed
25 Fixed Fixed Fixed Fixed Fixed Fixed
26 Fixed Fixed Fixed Fixed Fixed Fixed
27 Fixed Fixed Fixed Fixed Fixed Fixed
37 Fixed Fixed Fixed Fixed Fixed Fixed
38 Fixed Fixed Fixed Fixed Fixed Fixed
39 Fixed Fixed Fixed Fixed Fixed Fixed
49 Fixed Fixed Fixed Fixed Fixed Fixed
50 Fixed Fixed Fixed Fixed Fixed Fixed
51 Fixed Fixed Fixed Fixed Fixed Fixed
1 EARTHQUAKE XA Seismic
2 EARTHQUAKE XB Seismic
3 EARTHQUAKE ZA Seismic
4 EARTHQUAKE ZB Seismic
5 DEAD LOAD Dead
6 LIVE LOAD Live
7 ROOF LIVE LOAD Roof Live
Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 4 of 8
Job No Sheet No Rev
5
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
UBC X 1.000
UBC X -1.000
UBC Z 1.000
UBC Z -1.000
Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 5 of 8
Job No Sheet No Rev
6
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Y -1.000 ALL
Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 6 of 8
Job No Sheet No Rev
7
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 7 of 8
Job No Sheet No Rev
8
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max FX 2 17:GENERATED 23.339 208.877 0.454 -0.064 0.037 -40.717
Min FX 26 16:GENERATED -23.710 285.299 0.951 0.464 0.110 40.959
Max FY 14 9:GENERATED -0.715 309.808 1.384 0.623 -0.260 0.481
Min FY 2 3:EARTHQUAKE 0.399 -33.710 -17.756 -35.513 -0.228 -0.737
Max FZ 50 11:GENERATED -0.051 193.466 2.126 1.157 -0.011 -1.486
Min FZ 38 18:GENERATED 0.518 236.447 -25.087 -40.752 0.062 -1.408
Max MX 50 11:GENERATED -0.051 193.466 2.126 1.157 -0.011 -1.486
Min MX 38 18:GENERATED 0.518 236.447 -25.087 -40.752 0.062 -1.408
Max MY 49 1:EARTHQUAKE -14.774 -17.250 -0.404 -0.701 0.497 31.842
Min MY 3 18:GENERATED 2.005 28.838 -11.319 -21.229 -0.621 -3.085
Max MZ 26 16:GENERATED -23.710 285.299 0.951 0.464 0.110 40.959
Min MZ 2 17:GENERATED 23.339 208.877 0.454 -0.064 0.037 -40.717
Failed Members
There is no data of this type.
Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 8 of 8
TRUSS LOAD COMPUTATIONS
depth, mm
REMARKS
base, mm
SECTION
Location
Number
Moment, Capacity,
BEAM
Beam
Number Diameter fy, fc' , ρreq not
Mu ρ computed ρ required As, mm^2 Mucap Mucap > Other
of Bars of RSB Mpa Mpa greater than
Mu Remarks
(KNm) (KNm) ρmax = 0.028
350 LEFT 6.661 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED
GB-1
x MID 2.248 31 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED
250 RIGHT 4.306 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED
450 LEFT 44.683 250 410 5 16 0.009808 0.00981 1,005.31 276 21 94.5981 PASSED PASSED
B-1
x MID 21.249 121 250 410 3 16 0.005885 0.00588 603.19 276 21 58.6276 PASSED PASSED
250 RIGHT 90.553 250 410 5 16 0.009808 0.00981 1,005.31 276 21 94.5981 PASSED PASSED
350 LEFT 0 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED
B-2
x MID 19.187 168 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED
250 RIGHT 34.561 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED
350 LEFT 0 200 310 2 16 0.006486 0.00649 402.12 276 21 29.4078 PASSED PASSED
B-3
x MID 19.743 165 200 310 2 16 0.006486 0.00649 402.12 276 21 29.4078 PASSED PASSED
200 RIGHT 0 200 310 2 16 0.006486 0.00649 402.12 276 21 29.4078 PASSED PASSED
400 LEFT 12.509 200 360 2 16 0.005585 0.00559 402.12 276 21 34.4022 PASSED PASSED
B-4
x MID 6.842 133 200 360 2 16 0.005585 0.00559 402.12 276 21 34.4022 PASSED PASSED
200 RIGHT 7.629 200 360 2 16 0.005585 0.00559 402.12 276 21 34.4022 PASSED PASSED
350 LEFT 14.038 250 310 4 16 0.010377 0.01038 804.25 276 21 56.9468 PASSED PASSED
RB-1
x MID 2.189 172 250 310 2 16 0.005189 0.00519 402.12 276 21 29.7193 PASSED PASSED
250 RIGHT 23.361 250 310 4 16 0.010377 0.01038 804.25 276 21 56.9468 PASSED PASSED
300 LEFT 8.152 200 260 3 16 0.0116 0.0116 603.19 276 21 35.4521 PASSED PASSED
RB-2
x MID 0.44 150 200 260 2 16 0.007733 0.00773 402.12 276 21 24.4134 PASSED PASSED
200 RIGHT 4.926 200 260 3 16 0.0116 0.0116 603.19 276 21 35.4521 PASSED PASSED
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 20:56 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 20:57 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 20:59 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 21:37 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 21:38 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 21:40 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 23 ( MAX AXIAL, CORR MOMENT), GROUND FLOOR
300 X 350 Column with reinf 6.20 6.20 = 0.17 < 1.0
+
10 Nos 16 dia @ 1.914 % is 63.11 72.87 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 72 ( MAX MOMENT, CORR AXIAL), GROUND FLOOR
300 X 350 Column with reinf 41.70 6.88 = 0.76 < 1.0
+
10 Nos 16 dia @ 1.914 % is 63.11 72.87 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 124 ( MAX MOMENT, CORR AXIAL), SECOND FLOOR
300 X 350 Column with reinf 61.19 0.92 = 0.98 < 1.0
+
10 Nos 16 dia @ 1.914 % is 63.11 72.87 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 27 ( MAX MOMENT, CORR AXIAL), GROUND FLOOR
300 X 300 Column with reinf 48.12 3.01 = 1.00 < 1.0
+
8 Nos 16 dia @ 1.787 % is 51.24 51.24 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 37 ( MAX MAXIAL, CORR MOMENT), GROUND FLOOR
300 X 300 Column with reinf 29.22 4.01 = 0.65 < 1.0
+
8 Nos 16 dia @ 1.787 % is 51.24 51.24 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 113 ( MAX MOMENT, CORR AXIAL), SECOND FLOOR
250 X 300 Column with reinf 30.38 0.63 = 0.61 < 1.0
+
6 Nos 16 dia @ 1.608 % is 51.53 39.27 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 128 ( MAX AXIAL, CORR MOMENT), SECOND FLOOR
250 X 300 Column with reinf 19.02 2.08 = 0.42 < 1.0
+
6 Nos 16 dia @ 1.608 % is 51.53 39.27 Safe
SAFE
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 00:13 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 00:18 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 00:32 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 00:32 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref
By Date05-Jan-19 Chd
Print Time/Date: 14/01/2019 00:33 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Isolated Footing Design Page 1 of 19
Input Values
Footing Geomtery
Column Dimensions
Pedestal
Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A
Design Parameters
Concrete and Rebar Properties
Soil Properties
------------------------------------------------------
Design Calculations
Footing Size
If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.
Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction
Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction
Shear Calculation
Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.
Along Z Direction
Check that 0.75 X Vc > Vuz where V uz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.
Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)
The strength values of steel and concrete used in the formulae are in ksi
Required = 0.00432
Since OK
Because the number of bars is rounded up, make sure new reinforcement ratio < ρ max
Total reinforcement area, As_total = Nbar X (Area of one bar) = 1809.577 mm2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.217 m
=
Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)
The strength values of steel and concrete used in the formulae are in ksi
Required = 0.00483
Since OK
Because the number of bars is rounded up, make sure new reinforcement ratio < ρ max
Total reinforcement area, As_total = Nbar X (Area of one bar) = 1809.577 mm2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.201 m
=
Isolated Footing 15
Input Values
Footing Geomtery
Column Dimensions
Pedestal
Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A
Design Parameters
Concrete and Rebar Properties
Soil Properties
------------------------------------------------------
Design Calculations
Footing Size
If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.
Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction
Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction
Shear Calculation
Along X Direction
Check that 0.75 X V c > V ux where V ux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.
Along Z Direction
Check that 0.75 X Vc > Vuz where V uz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.
Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)
The strength values of steel and concrete used in the formulae are in ksi
Required = 0.00229
Since OK
Because the number of bars is rounded up, make sure new reinforcement ratio < ρ max
Total reinforcement area, As_total = Nbar X (Area of one bar) = 804.256 mm2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.217 m
=
Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)
The strength values of steel and concrete used in the formulae are in ksi
Required = 0.00271
Since OK
Because the number of bars is rounded up, make sure new reinforcement ratio < ρ max
Total reinforcement area, A s_total = Nbar X (Area of one bar) = 804.256 mm2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.201 m
=