DESIGN DATA:

DEADLOADS:
Weight of Concrete : 24 kN/m3
Weight of Ceiling
Suspended Metal Lath and Gypsum Plaster : 0.48 kPa
Weight of Ext. Wall
6” CHB, plastered both faces : 2.73 kPa
4” CHB, plastered both faces : 2.11 kPa
Weight of Floor Fin. on Concrete slab
Ceramic or Quarry Tile (20mm)
on 13 mm mortar bed : 0.77 kPa
Weight of Railings : 0.75 kN/m
Others : (10% from total)
LIVE LOADS
 Basic Floor Area = 1.90 kPa
 Exterior Balconies = 2.90 kPa

ROOF LOADS
 see attached Design of Truss

ROOF LIVE LOADS

 Min. Roof Live Load = 0.75 kPa (NSCP p. 2-13)


STRUCTURAL ANALYSIS

CONSTRUCTION OF
TWO(2)-STOREY
RESIDENTIAL BUILDING

Owner: CLARITO M. MARTIN


Address: Brgy. 51-B Nangalisan, Laoag City, Ilocos Norte

Prepared by:

ROMULO T. BARTOLOME JR.


Civil Engineer
PRC ID:
PTR No. :
Issued:
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

PERSPECTIVE

Job Information
Engineer Checked Approved

Name:
Date: 05-Jan-19

Structure Type SPACE FRAME

Number of Nodes 78 Highest Node 94


Number of Elements 137 Highest Beam 175

Number of Basic Load Cases 7


Number of Combination Load Cases 17

Included in this printout are data for:


All The Whole Structure

Included in this printout are results for load cases:


Type L/C Name

Primary 1 EARTHQUAKE XA
Primary 2 EARTHQUAKE XB
Primary 3 EARTHQUAKE ZA
Primary 4 EARTHQUAKE ZB
Primary 5 DEAD LOAD
Primary 6 LIVE LOAD
Primary 7 ROOF LIVE LOAD
Combination 8 GENERATED ACI TABLE1 1
Combination 9 GENERATED ACI TABLE1 2
Combination 10 GENERATED ACI TABLE1 3
Combination 11 GENERATED ACI TABLE1 4
Combination 12 GENERATED ACI TABLE1 5
Combination 13 GENERATED ACI TABLE1 6
Combination 14 GENERATED ACI TABLE1 7
Combination 15 GENERATED ACI TABLE1 8

Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 8
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Job Information Cont...


Type L/C Name

Combination 16 GENERATED ACI TABLE1 9


Combination 17 GENERATED ACI TABLE1 10
Combination 18 GENERATED ACI TABLE1 11
Combination 19 GENERATED ACI TABLE1 12
Combination 20 GENERATED ACI TABLE1 13
Combination 21 GENERATED ACI TABLE1 14
Combination 22 GENERATED ACI TABLE1 15
Combination 23 GENERATED ACI TABLE1 16
Combination 24 GENERATED ACI TABLE1 17

4 1 5 2 6

76 77 78

16 16 17 17 18

85 86 87

28 31 29 32 30

94 95 96

40 46 41 47 42

103 104 105

Y X
52 61 53 62 54 Load 1
Z

GRADE BEAM FRAMING PLAN

7 3 90 1638 4 59 109 68 118 9

79 165 80 168 81

19 18 71 12120 19 91 167 21

88 166 89 90

31 33 73 12332 34 33

97 98 99

43 48 44 49 45
106 107 108
65 169 86 170 80

115 144 130

Y X 55 63 83 135 56 64 57
Z
Load 1
136 132 134
84 137 81 133 82

SECOND FLOOR FRAMING PLAN

Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 2 of 8
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

60 138 88 158 58 162 67

143 159 161

61 139 70 140 89 160 92 171 76

152 153 173 157

62 141 72 142 93 172 77

151 155 175 156

64 146 87 15485 147 94 174 79

149 150

Y X 66 148 75
Z Load 1
ROOF FRAMING PLAN

Section Properties
Prop Section Area Iyy Izz J Material
(cm2) (cm4) (cm4) (cm4)
1 Rect 0.30x0.35 1.05E+3 107E+3 78.8E+3 153E+3 CONCRETE
2 Rect 0.30x0.30 900.000 67.5E+3 67.5E+3 114E+3 CONCRETE
3 Rect 0.30x0.25 750.000 39.1E+3 56.3E+3 77.5E+3 CONCRETE
4 Rect 0.25x0.25 625.000 32.6E+3 32.6E+3 54.9E+3 CONCRETE
5 Rect 0.35x0.25 875.000 45.6E+3 89.3E+3 102E+3 CONCRETE
6 Rect 0.25x0.45 1.12E+3 190E+3 58.6E+3 153E+3 CONCRETE
7 Rect 0.25x0.35 875.000 89.3E+3 45.6E+3 102E+3 CONCRETE
8 Rect 0.20x0.35 700.000 71.5E+3 23.3E+3 60E+3 CONCRETE
9 Rect 0.20x0.40 800.000 107E+3 26.7E+3 73.2E+3 CONCRETE
10 Rect 0.25x0.35 875.000 89.3E+3 45.6E+3 102E+3 CONCRETE
11 Rect 0.20x0.30 600.000 45E+3 20E+3 47E+3 CONCRETE

Materials
Mat Name E  Density 
(kN/mm2) (kg/m3) (/°C)
1 STEEL 205.000 0.300 7.83E+3 12E -6
2 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
3 ALUMINUM 68.948 0.330 2.71E+3 23E -6
4 CONCRETE 21.718 0.170 2.4E+3 10E -6

Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 3 of 8
Job No Sheet No Rev
4
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Supports
Node X Y Z rX rY rZ
(kN/mm) (kN/mm) (kN/mm) (kN-m/deg) (kN-m/deg) (kN-m/deg)
1 Fixed Fixed Fixed Fixed Fixed Fixed
2 Fixed Fixed Fixed Fixed Fixed Fixed
3 Fixed Fixed Fixed Fixed Fixed Fixed
13 Fixed Fixed Fixed Fixed Fixed Fixed
14 Fixed Fixed Fixed Fixed Fixed Fixed
15 Fixed Fixed Fixed Fixed Fixed Fixed
25 Fixed Fixed Fixed Fixed Fixed Fixed
26 Fixed Fixed Fixed Fixed Fixed Fixed
27 Fixed Fixed Fixed Fixed Fixed Fixed
37 Fixed Fixed Fixed Fixed Fixed Fixed
38 Fixed Fixed Fixed Fixed Fixed Fixed
39 Fixed Fixed Fixed Fixed Fixed Fixed
49 Fixed Fixed Fixed Fixed Fixed Fixed
50 Fixed Fixed Fixed Fixed Fixed Fixed
51 Fixed Fixed Fixed Fixed Fixed Fixed

Primary Load Cases


Number Name Type

1 EARTHQUAKE XA Seismic
2 EARTHQUAKE XB Seismic
3 EARTHQUAKE ZA Seismic
4 EARTHQUAKE ZB Seismic
5 DEAD LOAD Dead
6 LIVE LOAD Live
7 ROOF LIVE LOAD Roof Live

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

8 GENERATED ACI TABLE1 1 5 DEAD LOAD 1.40


9 GENERATED ACI TABLE1 2 5 DEAD LOAD 1.20
6 LIVE LOAD 1.60
7 ROOF LIVE LOAD 0.50
10 GENERATED ACI TABLE1 3 5 DEAD LOAD 1.20
6 LIVE LOAD 1.60
11 GENERATED ACI TABLE1 4 5 DEAD LOAD 1.20
6 LIVE LOAD 1.00
7 ROOF LIVE LOAD 1.60
12 GENERATED ACI TABLE1 5 5 DEAD LOAD 1.20
7 ROOF LIVE LOAD 1.60
13 GENERATED ACI TABLE1 6 5 DEAD LOAD 1.20
6 LIVE LOAD 1.00
14 GENERATED ACI TABLE1 7 5 DEAD LOAD 1.20
15 GENERATED ACI TABLE1 8 5 DEAD LOAD 1.20
6 LIVE LOAD 1.00

Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 4 of 8
Job No Sheet No Rev
5
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Combination Load Cases Cont...


Comb. Combination L/C Name Primary Primary L/C Name Factor

7 ROOF LIVE LOAD 0.50


16 GENERATED ACI TABLE1 9 5 DEAD LOAD 1.20
6 LIVE LOAD 1.00
1 EARTHQUAKE XA 1.00
17 GENERATED ACI TABLE1 10 5 DEAD LOAD 1.20
6 LIVE LOAD 1.00
2 EARTHQUAKE XB 1.00
18 GENERATED ACI TABLE1 11 5 DEAD LOAD 1.20
6 LIVE LOAD 1.00
3 EARTHQUAKE ZA 1.00
19 GENERATED ACI TABLE1 12 5 DEAD LOAD 1.20
6 LIVE LOAD 1.00
4 EARTHQUAKE ZB 1.00
20 GENERATED ACI TABLE1 13 5 DEAD LOAD 0.90
21 GENERATED ACI TABLE1 14 5 DEAD LOAD 0.90
1 EARTHQUAKE XA 1.00
22 GENERATED ACI TABLE1 15 5 DEAD LOAD 0.90
2 EARTHQUAKE XB 1.00
23 GENERATED ACI TABLE1 16 5 DEAD LOAD 0.90
3 EARTHQUAKE ZA 1.00
24 GENERATED ACI TABLE1 17 5 DEAD LOAD 0.90
4 EARTHQUAKE ZB 1.00

1 EARTHQUAKE XA : Seismic Loading


Code Direction Factor

UBC X 1.000

2 EARTHQUAKE XB : Seismic Loading


Code Direction Factor

UBC X -1.000

3 EARTHQUAKE ZA : Seismic Loading


Code Direction Factor

UBC Z 1.000

4 EARTHQUAKE ZB : Seismic Loading


Code Direction Factor

UBC Z -1.000

Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 5 of 8
Job No Sheet No Rev
6
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

5 DEAD LOAD : Beam Loads


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
3 UNI kN/m GY -7.000 - - - -
4 UNI kN/m GY -0.750 - - - -
18 UNI kN/m GY -5.000 - - - -
19 UNI kN/m GY -7.000 - - - -
33 UNI kN/m GY -5.000 - - - -
34 UNI kN/m GY -5.000 - - - -
63 UNI kN/m GY -0.750 - - - -
79 UNI kN/m GY -7.000 - - - -
80 UNI kN/m GY -7.000 - - - -
81 UNI kN/m GY -0.750 - - - -
88 UNI kN/m GY -7.000 - - - -
90 UNI kN/m GY -7.000 - - - -
97 UNI kN/m GY -7.000 - - - -
98 UNI kN/m GY -5.000 - - - -
99 UNI kN/m GY -7.000 - - - -
106 UNI kN/m GY -7.000 - - - -
107 UNI kN/m GY -5.000 - - - -
108 UNI kN/m GY -7.000 - - - -
109 UNI kN/m GY -0.750 - - - -
115 UNI kN/m GY -0.750 - - - -
118 UNI kN/m GY -0.750 - - - -
121 UNI kN/m GY -5.000 - - - -
123 UNI kN/m GY -5.000 - - - -
130 UNI kN/m GY -0.750 - - - -
133 UNI kN/m GY -0.750 - - - -
134 UNI kN/m GY -0.750 - - - -
137 UNI kN/m GY -0.750 - - - -
163 UNI kN/m GY -7.000 - - - -
165 UNI kN/m GY -5.000 - - - -
166 UNI kN/m GY -5.000 - - - -
167 UNI kN/m GY -7.000 - - - -
169 UNI kN/m GY -7.000 - - - -
170 UNI kN/m GY -7.000 - - - -

5 DEAD LOAD : Floor Loads


Load Min Ht. Max Ht. Min X Max X Min Y Max Y
(N/mm2) (m) (m) (m) (m) (m) (m)
-0.004 4.800 5.800 - - - -
-0.001 7.600 8.600 - - - -

5 DEAD LOAD : Selfweight


Direction Factor Assigned Geometry

Y -1.000 ALL

Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 6 of 8
Job No Sheet No Rev
7
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

6 LIVE LOAD : Floor Loads


Load Min Ht. Max Ht. Min X Max X Min Y Max Y
(N/mm2) (m) (m) (m) (m) (m) (m)
-0.003 4.800 5.800 - - 11.000 13.000
-0.002 4.800 5.800 - - 0.000 11.000

7 ROOF LIVE LOAD : Floor Loads


Load Min Ht. Max Ht. Min X Max X Min Y Max Y
(N/mm2) (m) (m) (m) (m) (m) (m)
-0.001 7.600 8.600 - - - -

Beam Maximum Forces by Section Property


Axial Shear Torsion Bending
Section Max Fx Max Fy Max Fz Max Mx Max My Max Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Rect 0.30x0.35 Max +ve 309.808 25.526 9.371 3.673 40.752 40.959
Max -ve -33.710 -23.627 -25.087 -2.021 -36.153 -61.187
Rect 0.30x0.30 Max +ve 200.344 24.600 11.835 0.693 27.596 40.710
Max -ve -28.887 -22.850 -18.599 -1.498 -27.657 -48.116
Rect 0.30x0.25 Max +ve 53.528 16.104 10.132 2.639 15.493 38.264
Max -ve -7.067 -22.652 -3.133 -1.945 -17.059 -30.378
Rect 0.25x0.25 Max +ve 51.430 8.527 0.587 0.673 0.566 27.334
Max -ve -25.693 -16.454 -0.614 -0.056 -1.496 -20.748
Rect 0.35x0.25 Max +ve 5.637 16.010 0.380 1.073 0.727 30.701
Max -ve -12.530 -21.728 -0.390 -0.813 -0.639 -26.803
Rect 0.25x0.45 Max +ve 31.444 125.896 11.441 11.874 8.530 90.553
Max -ve -17.828 -146.286 -8.265 -13.788 -9.786 -58.552
Rect 0.25x0.35 Max +ve 0.413 20.317 0.000 3.423 0.000 0.000
Max -ve -1.048 -20.317 -0.000 -2.655 -0.000 -19.187
Rect 0.20x0.35 Max +ve 2.746 52.898 0.000 1.092 0.000 0.000
Max -ve -9.507 -52.898 -0.000 -5.027 -0.000 -71.368
Rect 0.20x0.40 Max +ve 2.271 16.262 0.563 3.042 1.331 17.940
Max -ve -1.794 -14.206 -0.841 -3.549 -1.484 -7.911
Rect 0.25x0.35 Max +ve 24.564 23.313 9.332 4.270 13.948 30.134
Max -ve -28.062 -29.652 -9.224 -7.706 -13.723 -24.902
Rect 0.20x0.30 Max +ve 6.943 14.848 3.660 3.362 3.827 13.848
Max -ve -1.542 -11.755 -1.446 -2.348 -3.494 -15.695

Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 7 of 8
Job No Sheet No Rev
8
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max FX 2 17:GENERATED 23.339 208.877 0.454 -0.064 0.037 -40.717
Min FX 26 16:GENERATED -23.710 285.299 0.951 0.464 0.110 40.959
Max FY 14 9:GENERATED -0.715 309.808 1.384 0.623 -0.260 0.481
Min FY 2 3:EARTHQUAKE 0.399 -33.710 -17.756 -35.513 -0.228 -0.737
Max FZ 50 11:GENERATED -0.051 193.466 2.126 1.157 -0.011 -1.486
Min FZ 38 18:GENERATED 0.518 236.447 -25.087 -40.752 0.062 -1.408
Max MX 50 11:GENERATED -0.051 193.466 2.126 1.157 -0.011 -1.486
Min MX 38 18:GENERATED 0.518 236.447 -25.087 -40.752 0.062 -1.408
Max MY 49 1:EARTHQUAKE -14.774 -17.250 -0.404 -0.701 0.497 31.842
Min MY 3 18:GENERATED 2.005 28.838 -11.319 -21.229 -0.621 -3.085
Max MZ 26 16:GENERATED -23.710 285.299 0.951 0.464 0.110 40.959
Min MZ 2 17:GENERATED 23.339 208.877 0.454 -0.064 0.037 -40.717

Statics Check Results


L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kNm) (kNm) (kNm)
1:EARTHQUAKE Loads 254.193 0.000 0.000 0.000 1.64E+3 -1.47E+3
1:EARTHQUAKE Reactions -254.193 -0.000 -0.000 0.000 -1.64E+3 1.47E+3
Difference -0.000 -0.000 -0.000 0.000 0.000 0.000
2:EARTHQUAKE Loads -254.193 0.000 0.000 0.000 -1.64E+3 1.47E+3
2:EARTHQUAKE Reactions 254.193 0.000 0.000 -0.000 1.64E+3 -1.47E+3
Difference 0.000 0.000 0.000 -0.000 -0.000 -0.000
3:EARTHQUAKE Loads 0.000 0.000 254.193 1.47E+3 -1.22E+3 0.000
3:EARTHQUAKE Reactions -0.000 0.000 -254.193 -1.47E+3 1.22E+3 0.000
Difference -0.000 0.000 -0.000 -0.000 0.000 0.000
4:EARTHQUAKE Loads 0.000 0.000 0.000 0.000 0.000 0.000
4:EARTHQUAKE Reactions 0.000 0.000 0.000 0.000 0.000 0.000
Difference 0.000 0.000 0.000 0.000 0.000 0.000
5:DEAD LOAD Loads 0.000 -1.92E+3 0.000 12.4E+3 0.000 -9.33E+3
5:DEAD LOAD Reactions 0.000 1.92E+3 -0.000 -12.4E+3 0.000 9.33E+3
Difference 0.000 0.000 -0.000 0.000 0.000 0.000
6:LIVE LOAD Loads 0.000 -267.000 0.000 1.85E+3 0.000 -1.34E+3
6:LIVE LOAD Reactions -0.000 267.000 0.000 -1.85E+3 0.000 1.34E+3
Difference -0.000 0.000 0.000 0.000 0.000 -0.000
7:ROOF LIVE LOADLoads 0.000 -81.000 0.000 530.250 0.000 -359.250
7:ROOF LIVE LOADReactions 0.000 81.000 0.000 -530.250 0.000 359.250
Difference 0.000 0.000 0.000 0.000 0.000 -0.000

Failed Members
There is no data of this type.

Print Time/Date: 14/01/2019 22:52 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 8 of 8
TRUSS LOAD COMPUTATIONS

Project: Two Storey Residential House (LARRY MARTIN) #####################


GEOMETRY DESIGN DATA
Height: 1.80 m Corrugated GI Roofing: 0.08 kPa
Inclined Length on 1 side: 6.16 m 2'' x 6 '' C - Purlins: 0.0876 KN/m
Trib. Width: 2.00 m Others: 0.1 kPa
Angle Theta: 19.80 deg. Purlin Spacing: 0.6 m
LOADS & DEFINITION
Dead Load: Live Load: (Use NSCP Provisions; p.2-13)
Roofing: 0.9856 KN Angle Theta: 19.80 deg
2
Purlin: 2.1024 KN Trib. Area: 12.32 m
Others: 1.232 KN Uniform Load: 0.75 (from NSCP)
TOTAL: 4.32 KN
Therefore use;
0.36 KN/sqm
(on each side)
Therefore use; Therefore use;
0.71 KN/m 1.5 KN/m
(on each side)
Wind Load:
Velocity Pressures: (Use NSCP Provisions;)
kzt = 1 ---------->> (p. 2-26) (use this interpolation calculator)for kz
kd = 0.85 ---------->> (p. 2-23) Height Cases 1 & 2
v = 200 ---------->> (p. 2-23) 6 0.9
Iw = 1 ---------->> (p. 2-24) 7 0.926666667
kz = 0.93 ---------->> (p. 2-25) 7.5 0.94
(Height is from NGL to midheight of roof)
Therefore: qh: 1.49 kPa
Design Wind Pressures: (Use NSCP Provisions;)
GCpf (p 2-49)
OPTION A: 1E= 0.690
For theta equal to 0-5 deg 2E= 0.270
or 30-45 deg, type the 3E= -0.530
values here; 4E= -0.480
OPTION B: 1E= 0.7974667
For conditions not in 2E= -1.07
option A, use interpolation 3E= -0.6878667
calculator below: 4E= -0.6372

For 1E: For 2E: For 3E: For 4E:


Theta Pressure Theta Pressure Theta Pressure Theta Pressure
5 0.61 5 -1.07 5 -0.53 5 -0.43
19.80 0.7974667 19.8 -1.07 19.8 -0.687867 19.8 -0.6372
20 0.8 20 -1.07 20 -0.69 20 -0.64
Type here what option you use: B (Type letter A or B only)
GCpi (p 2-42)
Type the values here: 0.18 -0.18
Calculated Wind Pressure: (in kPa)
1E; P1= 0.9200253 P2= 1.4564253
Positive means pressure.
2E; P1= -1.8625 P2= -1.3261
3E; P1= -1.2931213 P2= -0.7567213
Negative means suction.
4E; P1= -1.217628 P2= -0.681228
1E; P1= 0.1493548 P2= 0.2364327
Positive means pressure.
2E; P1= -0.3023539 P2= -0.215276
3E; P1= -0.2099223 P2= -0.1228444
Negative means suction.
4E; P1= -0.1976669 P2= -0.110589
Tabular Results for BEAM REINFORCEMENTS (Redesign using Design Moment Capacity)
Ult. Moment

depth, mm
REMARKS

base, mm
SECTION
Location

Number
Moment, Capacity,
BEAM

Beam
Number Diameter fy, fc' , ρreq not
Mu ρ computed ρ required As, mm^2 Mucap Mucap > Other
of Bars of RSB Mpa Mpa greater than
Mu Remarks
(KNm) (KNm) ρmax = 0.028

350 LEFT 6.661 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED
GB-1

x MID 2.248 31 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED

250 RIGHT 4.306 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED

450 LEFT 44.683 250 410 5 16 0.009808 0.00981 1,005.31 276 21 94.5981 PASSED PASSED
B-1

x MID 21.249 121 250 410 3 16 0.005885 0.00588 603.19 276 21 58.6276 PASSED PASSED

250 RIGHT 90.553 250 410 5 16 0.009808 0.00981 1,005.31 276 21 94.5981 PASSED PASSED

350 LEFT 0 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED
B-2

x MID 19.187 168 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED

250 RIGHT 34.561 250 310 3 16 0.007783 0.00778 603.19 276 21 43.6445 PASSED PASSED

350 LEFT 0 200 310 2 16 0.006486 0.00649 402.12 276 21 29.4078 PASSED PASSED
B-3

x MID 19.743 165 200 310 2 16 0.006486 0.00649 402.12 276 21 29.4078 PASSED PASSED

200 RIGHT 0 200 310 2 16 0.006486 0.00649 402.12 276 21 29.4078 PASSED PASSED

400 LEFT 12.509 200 360 2 16 0.005585 0.00559 402.12 276 21 34.4022 PASSED PASSED
B-4

x MID 6.842 133 200 360 2 16 0.005585 0.00559 402.12 276 21 34.4022 PASSED PASSED

200 RIGHT 7.629 200 360 2 16 0.005585 0.00559 402.12 276 21 34.4022 PASSED PASSED

350 LEFT 14.038 250 310 4 16 0.010377 0.01038 804.25 276 21 56.9468 PASSED PASSED
RB-1

x MID 2.189 172 250 310 2 16 0.005189 0.00519 402.12 276 21 29.7193 PASSED PASSED

250 RIGHT 23.361 250 310 4 16 0.010377 0.01038 804.25 276 21 56.9468 PASSED PASSED

300 LEFT 8.152 200 260 3 16 0.0116 0.0116 603.19 276 21 35.4521 PASSED PASSED
RB-2

x MID 0.44 150 200 260 2 16 0.007733 0.00773 402.12 276 21 24.4134 PASSED PASSED

200 RIGHT 4.926 200 260 3 16 0.0116 0.0116 603.19 276 21 35.4521 PASSED PASSED
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension value for an
beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 95 29 12:GENERATE 5.637 4.421 -0.237 -0.643 0.420 2.192
Min Fx 31 28 9:GENERATED -12.530 6.738 0.059 0.044 -0.148 6.927
Max Fy 31 28 17:GENERATE -11.614 16.010 0.012 -0.027 -0.021 30.701
Min Fy 77 17 18:GENERATE -3.059 -21.728 0.257 0.562 0.396 28.216
Max Fz 77 5 16:GENERATE -1.419 3.139 0.380 0.789 -0.573 1.121
Min Fz 95 29 16:GENERATE 4.278 4.451 -0.390 -0.706 0.727 2.292
Max Mx 78 6 16:GENERATE -1.080 3.626 0.214 1.073 -0.306 1.646
Min Mx 96 30 16:GENERATE -0.076 4.392 -0.312 -0.813 0.590 2.237
Max My 95 29 16:GENERATE 4.278 4.451 -0.390 -0.706 0.727 2.292
Min My 95 41 16:GENERATE 4.278 -4.208 -0.390 -0.706 -0.639 1.868
Max Mz 31 28 17:GENERATE -11.614 16.010 0.012 -0.027 -0.021 30.701
Min Mz 77 5 3:EARTHQUAK -1.582 -17.340 -0.049 0.117 0.086 -26.803

Print Time/Date: 14/01/2019 20:56 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension value for an
beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 4 8 17:GENERATE 31.444 84.751 1.106 0.847 -1.993 62.958
Min Fx 123 73 2:EARTHQUAK -17.828 13.794 -2.259 0.322 -0.139 1.939
Max Fy 107 44 9:GENERATED 2.451 125.896 -1.810 -0.559 1.347 61.406
Min Fy 123 32 11:GENERATE -1.200 -146.286 -1.887 -1.053 -1.396 88.588
Max Fz 121 71 3:EARTHQUAK -1.341 -1.048 11.441 2.208 -5.908 -0.457
Min Fz 130 80 16:GENERATE 1.819 -16.526 -8.265 -7.561 7.364 -24.565
Max Mx 132 56 17:GENERATE 0.581 30.991 -1.426 11.874 2.278 26.572
Min Mx 106 43 9:GENERATED -1.214 71.807 -2.625 -13.788 1.244 34.292
Max My 144 56 2:EARTHQUAK 0.539 -0.406 7.392 3.138 8.530 0.491
Min My 144 56 16:GENERATE -1.253 -46.932 -8.231 -0.489 -9.786 36.625
Max Mz 121 20 16:GENERATE 17.752 -141.442 -4.339 1.300 -5.488 90.553
Min Mz 107 86 11:GENERATE 1.593 113.454 -1.705 -0.067 -0.485 -58.552

Print Time/Date: 14/01/2019 20:57 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension value for an
beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 168 68 17:GENERATE 0.413 17.826 0.000 3.423 0.000 0.000
Min Fx 168 68 3:EARTHQUAK -1.048 -0.000 -0.000 -0.053 0.000 0.000
Max Fy 168 68 9:GENERATED 0.204 20.317 -0.000 0.806 0.000 0.000
Min Fy 168 91 9:GENERATED 0.204 -20.317 -0.000 0.806 -0.000 -0.000
Max Fz 168 68 2:EARTHQUAK 0.232 0.000 0.000 2.655 0.000 0.000
Min Fz 168 68 16:GENERATE -0.051 17.826 -0.000 -1.886 0.000 0.000
Max Mx 168 68 17:GENERATE 0.413 17.826 0.000 3.423 0.000 0.000
Min Mx 168 68 1:EARTHQUAK -0.232 -0.000 -0.000 -2.655 0.000 0.000
Max My 168 68 1:EARTHQUAK -0.232 -0.000 -0.000 -2.655 0.000 0.000
Min My 168 68 1:EARTHQUAK -0.232 -0.000 -0.000 -2.655 0.000 0.000
Max Mz 168 68 1:EARTHQUAK -0.232 -0.000 -0.000 -2.655 0.000 0.000
Min Mz 168 68 1:EARTHQUAK -0.232 -0.000 -0.000 -2.655 0.000 0.000

Print Time/Date: 14/01/2019 20:59 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension value for an
beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 166 71 1:EARTHQUAK 2.746 -0.000 -0.000 0.509 0.000 0.000
Min Fx 170 86 17:GENERATE -9.507 48.135 -0.000 0.491 0.000 0.000
Max Fy 169 65 9:GENERATED -6.314 52.898 0.000 -0.608 0.000 0.000
Min Fy 169 86 9:GENERATED -6.314 -52.898 0.000 -0.608 -0.000 -0.000
Max Fz 165 90 2:EARTHQUAK -0.864 0.000 0.000 -1.092 0.000 0.000
Min Fz 165 90 16:GENERATE -0.955 23.274 -0.000 -2.844 0.000 0.000
Max Mx 165 90 1:EARTHQUAK 0.864 -0.000 -0.000 1.092 0.000 0.000
Min Mx 165 90 17:GENERATE -2.683 23.274 0.000 -5.027 0.000 0.000
Max My 165 90 1:EARTHQUAK 0.864 -0.000 -0.000 1.092 0.000 0.000
Min My 165 90 1:EARTHQUAK 0.864 -0.000 -0.000 1.092 0.000 0.000
Max Mz 165 90 1:EARTHQUAK 0.864 -0.000 -0.000 1.092 0.000 0.000
Min Mz 165 90 1:EARTHQUAK 0.864 -0.000 -0.000 1.092 0.000 0.000

Print Time/Date: 14/01/2019 21:37 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension value for an
beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 133 81 16:GENERATE 2.271 11.863 0.281 0.747 -0.736 7.325
Min Fx 133 81 2:EARTHQUAK -1.794 2.199 -0.137 0.471 0.335 5.307
Max Fy 133 81 17:GENERATE -1.318 16.262 0.007 1.688 -0.066 17.940
Min Fy 133 82 16:GENERATE 2.271 -14.206 0.281 0.747 0.670 13.183
Max Fz 133 81 18:GENERATE -0.356 14.011 0.563 1.403 -1.484 12.509
Min Fz 137 84 18:GENERATE 0.000 -1.701 -0.841 0.105 -0.000 -0.136
Max Mx 136 83 1:EARTHQUAK 0.464 -0.000 -0.000 3.042 0.000 0.000
Min Mx 136 83 22:GENERATE -0.539 1.276 0.000 -3.549 0.000 0.000
Max My 133 82 18:GENERATE -0.356 -12.059 0.563 1.403 1.331 7.629
Min My 133 81 18:GENERATE -0.356 14.011 0.563 1.403 -1.484 12.509
Max Mz 133 81 17:GENERATE -1.318 16.262 0.007 1.688 -0.066 17.940
Min Mz 133 82 2:EARTHQUAK -1.794 2.199 -0.137 0.471 -0.350 -5.689

Print Time/Date: 14/01/2019 21:38 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension value for an
beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 139 61 9:GENERATED 24.564 12.637 1.401 -0.990 -2.899 16.441
Min Fx 158 88 17:GENERATE -28.062 -8.138 2.027 -0.014 -4.593 -10.053
Max Fy 142 72 12:GENERATE 12.194 23.313 -0.270 -0.091 0.629 25.594
Min Fy 162 58 17:GENERATE -13.473 -29.652 0.123 -0.215 0.356 25.549
Max Fz 154 87 18:GENERATE 6.335 -13.946 9.332 -7.706 -4.006 -5.983
Min Fz 159 88 17:GENERATE 4.229 6.926 -9.224 1.287 13.948 5.452
Max Mx 156 77 11:GENERATE 0.476 10.331 1.653 4.270 -4.048 8.884
Min Mx 154 87 18:GENERATE 6.335 -13.946 9.332 -7.706 -4.006 -5.983
Max My 159 88 17:GENERATE 4.229 6.926 -9.224 1.287 13.948 5.452
Min My 159 70 17:GENERATE 4.229 -3.046 -9.224 1.287 -13.723 -0.367
Max Mz 172 77 11:GENERATE 13.180 -28.493 -0.166 -0.132 -0.800 30.134
Min Mz 172 93 11:GENERATE 13.180 -17.371 -0.166 -0.132 -0.403 -24.902

Print Time/Date: 14/01/2019 21:40 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 23 ( MAX AXIAL, CORR MOMENT), GROUND FLOOR

Column Dimensions Rcc Characteristics Slenderness Ratios


Width Depth Leff (width) Leff (depth) Conc Grade Reinf Grade Clear Cover
2 2
Leff/B Leff/D
mm mm m m N/mm N/mm mm
300 350 3 3 21 276 40 10.00 8.57 Mux1
0.094
FckBD2

Reinforcement Summary of Reinforcement Spacing Muy1


2 0.095
Dia (mm) # of Bars Along Total #s Area %age @ width @ depth FckDB
2
Main Ties Width Depth cm mm mm
16 10 3 4 10 20.10 1.914 % 86.00 68.67

Factored Forces & Moments Ecc' Moments (Kn-m)


Axial (Kn) Bending Moment (Kn-m) @ width @ depth
( Pu ) ( Mub ) ( Mud ) ( Meb ) ( Med )
6.20 6.20
309.81 0.62 0.48
Min Ecc Min Ecc

Summary of Bending Moments (Kn-m) Axial Load Capacity


Type @ width @ depth 809.66
Initial 0.62 0.48
Ecc 6.20 6.20 Moment Capacity
Slenderness 0.00 0.00 @ width @ depth
Final 6.20 6.20 63.11 72.87

Summary of Design Interaction Equation

300 X 350 Column with reinf 6.20 6.20 = 0.17 < 1.0
+
10 Nos 16 dia @ 1.914 % is 63.11 72.87 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 72 ( MAX MOMENT, CORR AXIAL), GROUND FLOOR

Column Dimensions Rcc Characteristics Slenderness Ratios


Width Depth Leff (width) Leff (depth) Conc Grade Reinf Grade Clear Cover
2 2
Leff/B Leff/D
mm mm m m N/mm N/mm mm
300 350 3 3 21 276 40 10.00 8.57 Mux1
0.094
FckBD2

Reinforcement Summary of Reinforcement Spacing Muy1


2 0.095
Dia (mm) # of Bars Along Total #s Area %age @ width @ depth FckDB
2
Main Ties Width Depth cm mm mm
16 10 3 4 10 20.10 1.914 % 86.00 68.67

Factored Forces & Moments Ecc' Moments (Kn-m)


Axial (Kn) Bending Moment (Kn-m) @ width @ depth
( Pu ) ( Mub ) ( Mud ) ( Meb ) ( Med )
1.66 1.66
83.21 41.70 6.88
Min Ecc Min Ecc

Summary of Bending Moments (Kn-m) Axial Load Capacity


Type @ width @ depth 809.66
Initial 41.70 6.88
Ecc 1.66 1.66 Moment Capacity
Slenderness 0.00 0.00 @ width @ depth
Final 41.70 6.88 63.11 72.87

Summary of Design Interaction Equation

300 X 350 Column with reinf 41.70 6.88 = 0.76 < 1.0
+
10 Nos 16 dia @ 1.914 % is 63.11 72.87 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 124 ( MAX MOMENT, CORR AXIAL), SECOND FLOOR

Column Dimensions Rcc Characteristics Slenderness Ratios


Width Depth Leff (width) Leff (depth) Conc Grade Reinf Grade Clear Cover
2 2
Leff/B Leff/D
mm mm m m N/mm N/mm mm
300 350 2.8 2.8 21 276 40 9.33 8.00 Mux1
0.094
FckBD2

Reinforcement Summary of Reinforcement Spacing Muy1


2 0.095
Dia (mm) # of Bars Along Total #s Area %age @ width @ depth FckDB
2
Main Ties Width Depth cm mm mm
16 10 3 4 10 20.10 1.914 % 86.00 68.67

Factored Forces & Moments Ecc' Moments (Kn-m)


Axial (Kn) Bending Moment (Kn-m) @ width @ depth
( Pu ) ( Mub ) ( Mud ) ( Meb ) ( Med )
0.92 0.92
46.17 61.19 0.42
Min Ecc Min Ecc

Summary of Bending Moments (Kn-m) Axial Load Capacity


Type @ width @ depth 809.66
Initial 61.19 0.42
Ecc 0.92 0.92 Moment Capacity
Slenderness 0.00 0.00 @ width @ depth
Final 61.19 0.92 63.11 72.87

Summary of Design Interaction Equation

300 X 350 Column with reinf 61.19 0.92 = 0.98 < 1.0
+
10 Nos 16 dia @ 1.914 % is 63.11 72.87 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 27 ( MAX MOMENT, CORR AXIAL), GROUND FLOOR

Column Dimensions Rcc Characteristics Slenderness Ratios


Width Depth Leff (width) Leff (depth) Conc Grade Reinf Grade Clear Cover
2 2
Leff/B Leff/D
mm mm m m N/mm N/mm mm
300 300 3 3 21 276 40 10.00 10.00 Mux1
2 0.090
FckBD

Reinforcement Summary of Reinforcement Spacing Muy1


2 0.090
Dia (mm) # of Bars Along Total #s Area %age @ width @ depth FckDB
2
Main Ties Width Depth cm mm mm
16 10 3 3 8 16.08 1.787 % 86.00 86.00

Factored Forces & Moments Ecc' Moments (Kn-m)


Axial (Kn) Bending Moment (Kn-m) @ width @ depth
( Pu ) ( Mub ) ( Mud ) ( Meb ) ( Med )
2.76 2.76
137.88 48.12 3.01
Min Ecc Min Ecc

Summary of Bending Moments (Kn-m) Axial Load Capacity


Type @ width @ depth 740.51
Initial 48.12 3.01
Ecc 2.76 2.76 Moment Capacity
Slenderness 0.00 0.00 @ width @ depth
Final 48.12 3.01 51.24 51.24

Summary of Design Interaction Equation

300 X 300 Column with reinf 48.12 3.01 = 1.00 < 1.0
+
8 Nos 16 dia @ 1.787 % is 51.24 51.24 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 37 ( MAX MAXIAL, CORR MOMENT), GROUND FLOOR

Column Dimensions Rcc Characteristics Slenderness Ratios


Width Depth Leff (width) Leff (depth) Conc Grade Reinf Grade Clear Cover
2 2
Leff/B Leff/D
mm mm m m N/mm N/mm mm
300 300 3 3 21 276 40 10.00 10.00 Mux1
2 0.090
FckBD

Reinforcement Summary of Reinforcement Spacing Muy1


2 0.090
Dia (mm) # of Bars Along Total #s Area %age @ width @ depth FckDB
2
Main Ties Width Depth cm mm mm
16 10 3 3 8 16.08 1.787 % 86.00 86.00

Factored Forces & Moments Ecc' Moments (Kn-m)


Axial (Kn) Bending Moment (Kn-m) @ width @ depth
( Pu ) ( Mub ) ( Mud ) ( Meb ) ( Med )
4.01 4.01
200.34 29.22 0.09
Min Ecc Min Ecc

Summary of Bending Moments (Kn-m) Axial Load Capacity


Type @ width @ depth 740.51
Initial 29.22 0.09
Ecc 4.01 4.01 Moment Capacity
Slenderness 0.00 0.00 @ width @ depth
Final 29.22 4.01 51.24 51.24

Summary of Design Interaction Equation

300 X 300 Column with reinf 29.22 4.01 = 0.65 < 1.0
+
8 Nos 16 dia @ 1.787 % is 51.24 51.24 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 113 ( MAX MOMENT, CORR AXIAL), SECOND FLOOR

Column Dimensions Rcc Characteristics Slenderness Ratios


Width Depth Leff (width) Leff (depth) Conc Grade Reinf Grade Clear Cover
2 2
Leff/B Leff/D
mm mm m m N/mm N/mm mm
250 300 2.8 2.8 21 276 40 11.20 9.33 Mux1
2 0.083
FckBD

Reinforcement Summary of Reinforcement Spacing Muy1


2 0.131
Dia (mm) # of Bars Along Total #s Area %age @ width @ depth FckDB
2
Main Ties Width Depth cm mm mm
16 10 2 3 6 12.06 1.608 % 138.00 86.00

Factored Forces & Moments Ecc' Moments (Kn-m)


Axial (Kn) Bending Moment (Kn-m) @ width @ depth
( Pu ) ( Mub ) ( Mud ) ( Meb ) ( Med )
0.63 0.63
31.36 30.38 0.09
Min Ecc Min Ecc

Summary of Bending Moments (Kn-m) Axial Load Capacity


Type @ width @ depth 286.43
Initial 30.38 0.09
Ecc 0.63 0.63 Moment Capacity
Slenderness 0.00 0.00 @ width @ depth
Final 30.38 0.63 51.53 39.27

Summary of Design Interaction Equation

250 X 300 Column with reinf 30.38 0.63 = 0.61 < 1.0
+
6 Nos 16 dia @ 1.608 % is 51.53 39.27 Safe
SAFE
Design of RCC Rectangular Columns
Project : CLARITO MARTIN (TWO-STOREY RESIDENTIAL)
Col Id : COLUMN NO. 128 ( MAX AXIAL, CORR MOMENT), SECOND FLOOR

Column Dimensions Rcc Characteristics Slenderness Ratios


Width Depth Leff (width) Leff (depth) Conc Grade Reinf Grade Clear Cover
2 2
Leff/B Leff/D
mm mm m m N/mm N/mm mm
250 300 2.8 2.8 21 276 40 11.20 9.33 Mux1
2 0.083
FckBD

Reinforcement Summary of Reinforcement Spacing Muy1


2 0.131
Dia (mm) # of Bars Along Total #s Area %age @ width @ depth FckDB
2
Main Ties Width Depth cm mm mm
16 10 2 3 6 12.06 1.608 % 138.00 86.00

Factored Forces & Moments Ecc' Moments (Kn-m)


Axial (Kn) Bending Moment (Kn-m) @ width @ depth
( Pu ) ( Mub ) ( Mud ) ( Meb ) ( Med )
1.07 1.07
53.53 19.02 2.08
Min Ecc Min Ecc

Summary of Bending Moments (Kn-m) Axial Load Capacity


Type @ width @ depth 286.43
Initial 19.02 2.08
Ecc 1.07 1.07 Moment Capacity
Slenderness 0.00 0.00 @ width @ depth
Final 19.02 2.08 51.53 39.27

Summary of Design Interaction Equation

250 X 300 Column with reinf 19.02 2.08 = 0.42 < 1.0
+
6 Nos 16 dia @ 1.608 % is 51.53 39.27 Safe
SAFE
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension value for an
beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 23 14 9:GENERATED 309.808 0.715 1.384 -0.260 -0.623 0.481
Min Fx 8 2 3:EARTHQUAK -33.710 -0.399 -17.756 -0.228 35.513 -0.737
Max Fy 38 26 16:GENERATE 285.299 23.710 0.951 0.110 -0.464 40.959
Min Fy 71 53 17:GENERATE 162.669 -23.627 -3.811 -0.361 5.050 -35.607
Max Fz 56 41 11:GENERATE 245.737 -1.298 9.371 0.035 -3.037 -3.353
Min Fz 53 38 18:GENERATE 236.447 -0.518 -25.087 0.062 40.752 -1.408
Max Mx 70 52 16:GENERATE 76.131 5.703 -5.151 0.842 4.997 12.312
Min Mx 70 52 2:EARTHQUAK 9.041 -12.289 0.068 -0.765 -0.360 -19.749
Max My 53 38 18:GENERATE 236.447 -0.518 -25.087 0.062 40.752 -1.408
Min My 26 20 18:GENERATE 254.818 1.388 -24.531 -0.450 -36.153 -6.388
Max Mz 38 26 16:GENERATE 285.299 23.710 0.951 0.110 -0.464 40.959
Min Mz 72 57 16:GENERATE 83.208 22.238 -3.601 0.595 -6.882 -41.700

Print Time/Date: 14/01/2019 00:13 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension value for an
beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 124 73 12:GENERATE 67.249 10.692 -1.352 -0.539 0.282 -42.868
Min Fx 164 88 2:EARTHQUAK -5.722 -4.731 0.007 1.660 0.318 -4.994
Max Fy 124 72 16:GENERATE 37.855 25.526 -1.000 -0.946 2.384 10.285
Min Fy 124 72 2:EARTHQUAKE XB-4.001 -12.838 0.588 0.414 -1.043 -18.894
Max Fz 122 70 18:GENERATED AC26.457
I TABLE1 1112.309 5.424 2.718 -12.748 -8.221
Min Fz 164 88 11:GENERATE 10.254 18.237 -3.567 1.866 6.181 11.455
Max Mx 122 70 17:GENERATE 22.289 2.868 0.474 3.673 0.593 -21.524
Min Mx 122 70 1:EARTHQUAK 2.932 9.688 -0.138 -2.021 -0.107 13.784
Max My 164 88 11:GENERATE 10.254 18.237 -3.567 1.866 6.181 11.455
Min My 122 70 3:EARTHQUAK 1.236 -0.248 5.088 1.066 -13.234 -0.481
Max Mz 124 72 1:EARTHQUAK 4.001 12.838 -0.588 -0.414 1.043 18.894
Min Mz 124 73 16:GENERATE 46.168 25.526 -1.000 -0.946 -0.416 -61.187

Print Time/Date: 14/01/2019 00:18 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension
value for an beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 128 33 11:GENERATED 53.528 16.104 0.476 -0.458 2.075 -19.024
Min Fx 116 64 3:EARTHQUAKE -7.067 -0.008 10.132 0.386 -12.877 -0.104
Max Fy 128 77 11:GENERATED 47.591 16.104 0.476 -0.458 0.743 26.067
Min Fy 113 62 11:GENERATED 36.456 -22.652 -1.578 -0.320 3.809 -26.056
Max Fz 116 64 3:EARTHQUAKE -7.067 -0.008 10.132 0.386 -12.877 -0.104
Min Fz 111 60 17:GENERATED 15.395 -6.328 -3.133 2.639 3.561 -10.948
Max Mx 111 60 17:GENERATED 15.395 -6.328 -3.133 2.639 3.561 -10.948
Min Mx 131 79 18:GENERATED 17.269 9.127 6.754 -1.945 -10.088 11.892
Max My 116 65 3:EARTHQUAKE -7.067 -0.008 10.132 0.386 15.493 -0.081
Min My 116 64 18:GENERATED 5.629 -7.497 9.550 -0.568 -17.059 -9.372
Max Mz 113 31 9:GENERATED 35.847 -22.233 -1.282 -0.368 -0.456 38.264
Min Mz 113 62 17:GENERATED 31.355 -22.626 -1.554 0.330 3.374 -30.378

Print Time/Date: 14/01/2019 00:32 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension value for an
beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 128 33 11:GENERATE 53.528 16.104 0.476 -0.458 2.075 -19.024
Min Fx 116 64 3:EARTHQUAK -7.067 -0.008 10.132 0.386 -12.877 -0.104
Max Fy 128 77 11:GENERATE 47.591 16.104 0.476 -0.458 0.743 26.067
Min Fy 113 62 11:GENERATE 36.456 -22.652 -1.578 -0.320 3.809 -26.056
Max Fz 116 64 3:EARTHQUAK -7.067 -0.008 10.132 0.386 -12.877 -0.104
Min Fz 111 60 17:GENERATE 15.395 -6.328 -3.133 2.639 3.561 -10.948
Max Mx 111 60 17:GENERATE 15.395 -6.328 -3.133 2.639 3.561 -10.948
Min Mx 131 79 18:GENERATE 17.269 9.127 6.754 -1.945 -10.088 11.892
Max My 116 65 3:EARTHQUAK -7.067 -0.008 10.132 0.386 15.493 -0.081
Min My 116 64 18:GENERATE 5.629 -7.497 9.550 -0.568 -17.059 -9.372
Max Mz 113 31 9:GENERATED 35.847 -22.233 -1.282 -0.368 -0.456 38.264
Min Mz 113 62 17:GENERATE 31.355 -22.626 -1.554 0.330 3.374 -30.378

Print Time/Date: 14/01/2019 00:32 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date05-Jan-19 Chd

Client File CLARITO_MARTIN_2STY Date/Time 14-Jan-2019 00:10

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension value for an
beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 37 25 17:GENERATE 200.344 -12.276 0.269 -0.009 0.094 -29.215
Min Fx 7 1 3:EARTHQUAK -28.887 -0.368 -12.672 0.090 22.976 -0.648
Max Fy 27 18 16:GENERATE 145.515 24.600 0.966 -0.736 0.115 25.684
Min Fy 10 4 17:GENERATE 99.403 -22.850 1.837 0.536 -1.128 -27.841
Max Fz 145 85 3:EARTHQUAK -5.285 0.440 11.835 -0.403 -12.695 0.902
Min Fz 52 37 18:GENERATE 137.134 0.657 -18.599 0.124 27.596 -0.562
Max Mx 126 75 3:EARTHQUAK 6.959 -0.113 2.399 0.693 -6.897 -0.008
Min Mx 145 85 16:GENERATE 23.517 3.701 -3.259 -1.498 -5.577 9.641
Max My 52 37 18:GENERATE 137.134 0.657 -18.599 0.124 27.596 -0.562
Min My 55 43 3:EARTHQUAK -16.351 0.091 -17.945 -0.012 -27.657 -0.156
Max Mz 10 7 17:GENERATE 91.769 -22.850 1.837 0.536 4.383 40.710
Min Mz 27 21 16:GENERATE 137.881 24.600 0.966 -0.736 3.011 -48.116

Print Time/Date: 14/01/2019 00:33 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1
Isolated Footing Design Page 1 of 19

Isolated Footing Design(ACI 318-05)

Footing No. Group ID Foundation Geometry


- - Length Width Thickness
1 1 1.500 m 1.500 m 0.300 m
2 2 1.800 m 1.800 m 0.300 m
3 3 1.400 m 1.400 m 0.300 m
13 4 1.650 m 1.650 m 0.300 m
14 5 1.950 m 1.950 m 0.300 m
15 6 1.600 m 1.600 m 0.300 m
25 7 1.650 m 1.650 m 0.300 m
26 8 1.950 m 1.950 m 0.300 m
27 9 1.700 m 1.700 m 0.300 m
37 10 1.650 m 1.650 m 0.300 m
38 11 1.900 m 1.900 m 0.300 m
39 12 1.600 m 1.600 m 0.300 m
49 13 1.600 m 1.600 m 0.300 m
50 14 1.750 m 1.750 m 0.300 m
51 15 1.550 m 1.550 m 0.300 m

Footing No. Footing Reinforcement Pedestal Reinforcement


- Bottom Reinforcement(Mz) Bottom Reinforcement(Mx ) Top Reinforcement(Mz) Top Reinforcement(Mx ) Main Steel Trans Steel
1 #16 @ 500 mm c/c #16 @ 500 mm c/c N/A N/A N/A N/A
2 #16 @ 325 mm c/c #16 @ 325 mm c/c N/A N/A N/A N/A
3 #16 @ 500 mm c/c #16 @ 500 mm c/c N/A N/A N/A N/A
13 #16 @ 370 mm c/c #16 @ 370 mm c/c N/A N/A N/A N/A
14 #16 @ 220 mm c/c #16 @ 220 mm c/c N/A N/A N/A N/A
15 #16 @ 475 mm c/c #16 @ 475 mm c/c N/A N/A N/A N/A
25 #16 @ 370 mm c/c #16 @ 370 mm c/c N/A N/A N/A N/A
26 #16 @ 220 mm c/c #16 @ 220 mm c/c N/A N/A N/A N/A
27 #16 @ 380 mm c/c #16 @ 380 mm c/c N/A N/A N/A N/A
37 #16 @ 370 mm c/c #16 @ 490 mm c/c N/A N/A N/A N/A
38 #16 @ 245 mm c/c #16 @ 245 mm c/c N/A N/A N/A N/A
39 #16 @ 355 mm c/c #16 @ 475 mm c/c N/A N/A N/A N/A
49 #16 @ 500 mm c/c #16 @ 475 mm c/c N/A N/A N/A N/A
50 #16 @ 315 mm c/c #16 @ 395 mm c/c N/A N/A N/A N/A
51 #16 @ 500 mm c/c #16 @ 460 mm c/c N/A N/A N/A N/A

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 2 of 19
Isolated Footing 14

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 300.000 mm
Footing Length - X (Fl) : 1000.000 mm
Footing Width - Z (Fw) : 1000.000 mm
Eccentricity along X (Oxd) : 0.000 mm
Eccentricity along Z (Ozd) : 0.000 mm

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 0.300 m
Column Width - Z (Pw) : 0.350 m

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 3 of 19

Design Parameters
Concrete and Rebar Properties

Unit Weight of Concrete : 25.000 kN/m3

Strength of Concrete : 21.000 N/mm2


Yield Strength of Steel : 276.000 N/mm2
Minimum Bar Size : #16
Maximum Bar Size : #16
Minimum Bar Spacing : 50.000 mm
Maximum Bar Spacing : 500.000 mm
Pedestal Clear Cover (P, CL) : 75.000 mm
Footing Clear Cover (F, CL) : 75.000 mm

Soil Properties

Soil Type : Drained


Unit Weight : 22.000 kN/m3
Soil Bearing Capacity : 120.000 kN/m2
Soil Surcharge : 0.000 kN/m2
Depth of Soil above Footing : 1500.000 mm
Cohesion : 0.000 kN/m2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations
Footing Size

Initial Length (Lo) = 1.000 m

Initial Width (Wo) = 1.000 m

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
16 GENERATED ACI TABLE1 9
17 GENERATED ACI TABLE1 10
18 GENERATED ACI TABLE1 11
19 GENERATED ACI TABLE1 12
20 GENERATED ACI TABLE1 13
21 GENERATED ACI TABLE1 14
22 GENERATED ACI TABLE1 15
23 GENERATED ACI TABLE1 16
24 GENERATED ACI TABLE1 17

Load Combination/s- Strength Level


Load Combination
Load Combination Title
Number
8 GENERATED ACI TABLE1 1
9 GENERATED ACI TABLE1 2
10 GENERATED ACI TABLE1 3
11 GENERATED ACI TABLE1 4
12 GENERATED ACI TABLE1 5
13 GENERATED ACI TABLE1 6
14 GENERATED ACI TABLE1 7
15 GENERATED ACI TABLE1 8

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 4 of 19
Applied Loads - Service Stress Level
Axial Shear X Shear Z Moment X Moment Z
LC
(kN) (kN) (kN) (kNm) (kNm)
16 289.926 23.496 -1.379 -0.722 -40.118

17 281.147 -22.179 -1.285 -0.482 39.216


18 295.511 0.565 21.716 38.515 -0.259
19 285.536 0.658 -1.332 -0.602 -0.451
20 190.144 0.215 -0.964 -0.440 -0.123
21 194.534 23.052 -1.010 -0.560 -39.790
22 185.755 -22.623 -0.917 -0.320 39.544
23 200.119 0.121 22.085 38.677 0.069
24 190.144 0.215 -0.964 -0.440 -0.123

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kN) (kN) (kN) (kNm) (kNm)
8 295.780 0.334 -1.499 -0.684 -0.191
9 309.808 0.715 -1.384 -0.623 -0.481
10 304.743 0.882 -1.361 -0.611 -0.623
11 301.744 0.125 -1.407 -0.639 0.004
12 269.734 -0.247 -1.360 -0.623 0.291
13 285.536 0.658 -1.332 -0.602 -0.451
14 253.526 0.286 -1.285 -0.586 -0.164
15 290.601 0.492 -1.356 -0.613 -0.309

Reduction of force due to buoyancy = 0.000 kN


Effect due to adhesion = 0.000 kN
Area from initial length and width, Ao = L X W = 1.000 m2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 2.084 m 2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 1.950 m Governing Load Case : # 16

Width (W2) = 1.950 m Governing Load Case : # 16

Depth (D2) = 0.300 m Governing Load Case : # 16

Area (A2) = 3.803 m 2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 5 of 19

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 (q corner 2 (q corner 3 (q corner 4 (q in uplift (A u )
Load Case )1 )2 )3 )4
(m 2)
(kN/m2) (kN/m2) (kN/m2) (kN/m2)

17 151.3440 77.1092 75.7053 149.9401 0.000

16 78.5853 154.9194 153.0817 76.7477 0.000

18 80.5177 81.2112 154.0871 153.3936 0.000

18 80.5177 81.2112 154.0871 153.3936 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q 1 ) corner 2 (q 2) corner 3 (q 3 ) corner 4 (q 4 )

Load Case (kN/m2) (kN/m2) (kN/m2) (kN/m2)

17 151.3440 77.1092 75.7053 149.9401

16 78.5853 154.9194 153.0817 76.7477

18 80.5177 81.2112 154.0871 153.3936

18 80.5177 81.2112 154.0871 153.3936

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

16 9.373 159.715 378.202 9.105

17 9.732 167.903 485.174 9.176

18 394.580 10.270 9.658 1014.865

19 331.178 163.665 424.532 655.550

20 793.974 176.759 455.777 1772.842

21 7.485 170.762 389.950 7.203

22 7.432 183.366 551.264 7.077

23 1444.296 7.939 7.547 10460.778

24 793.974 176.759 455.777 1772.842

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 6 of 19

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 22


Governing Disturbing Force : -22.623 kN
Governing Restoring Force : 168.143 kN
Minimum Sliding Ratio for the Critical Load Case : 7.432
Critical Load Case for Overturning about X-Direction : 23
Governing Overturning Moment : 45.302 kNm
Governing Resisting Moment : 341.878 kNm
Minimum Overturning Ratio for the Critical Load Case : 7.547

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 23


Governing Disturbing Force : 22.085 kN
Governing Restoring Force : 175.325 kN
Minimum Sliding Ratio for the Critical Load Case : 7.939
Critical Load Case for Overturning about Z-Direction : 22
Governing Overturning Moment : 46.331 kNm
Governing Resisting Moment : 327.872 kNm
Minimum Overturning Ratio for the Critical Load Case : 7.077

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 0.300m


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.200 m 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.167

Effective depth, deff , increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 427.097 kN, Load Case # 9

From ACI Cl.11.12.2.1, bo for column=


2.098 m

Equation 11-33, Vc1 = 865.173 kN

Equation 11-34, Vc2 = 925.136

kN Equation 11-35, Vc3 = 637.496


kN
Punching shear strength, Vc = 0.75 X minimum of (V c1, Vc2, Vc3) = 478.122 kN

0.75 X Vc > Vu hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 7 of 19
Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, V c = 296.206 kN

Distance along X to design for shear,


Dx = 0.600 m

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 222.155 kN

Critical load case for Vux is # 9 142.418 kN

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, V c = 296.206 kN

Distance along X to design for shear, D z = 1.325 m

Check that 0.75 X Vc > Vuz where V uz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 222.155 kN

Critical load case for Vuz is # 9 148.105 kN


0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 8 of 19

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 9

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.03765

From ACI Cl. 10.3.3, = 0.02824

From ACI Cl. 7.12.2, = 0.00200

From Ref. 1, Eq. 3.8.4a, constant m = 15.462

Calculate reinforcement ratio for critical load case


Design for flexure about Z axis is
performed at the face of the column 0.825 m
at a distance, Dx =

Ultimate moment, 80.605 kNm

Nominal moment capacity, Mn = 89.561 kNm

Required = 0.00432

Since OK

Area of Steel Required, As = 1681.956 mm2

Selected bar Size = #16


Minimum spacing allowed (Smin) = = 50.000 mm

Selected spacing (S) = 223.000 mm


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 383.566 mm

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#16 @ 5588.000 mm o.c.

Required development length for bars = =0.305 m


Available development length for bars, D L
0.750 m
=

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 9 of 19

Try bar size # 16 Area of one bar = 201.064 mm2

Number of bars required, Nbar =


9

Because the number of bars is rounded up, make sure new reinforcement ratio < ρ max

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1809.577 mm2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.217 m
=

Reinforcement ratio, = 0.00428


From ACI Cl.7.6.1, minimum req'd clear
distance between bars, Cd =
max (Diameter of one bar, 1.0, Min. User Spacing) =
223.000 mm

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 10 of 19

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 9

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.03765

From ACI Cl. 10.3.3, = 0.02824

From ACI Cl.7.12.2, = 0.00200

From Ref. 1, Eq. 3.8.4a, constant m = 15.462

Calculate reinforcement ratio for critical load case


Design for flexure about X axis is
performed at the face of the column 0.800 m
at a distance, Dz =

Ultimate moment, 75.922 kNm

Nominal moment capacity, Mn = 84.358 kNm

Required = 0.00483

Since OK

Area of Steel Required, As = 1729.340 mm2

Selected Bar Size = #16


Minimum spacing allowed (Smin) = 50.000 mm

Selected spacing (S) = 223.000 mm


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 383.566 mm

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 11 of 19

#16 @ 5588.000 mm o.c.

Required development length for bars = =0.305 m


Available development length for bars, D L
0.725 m
=
Try bar size # 16 Area of one bar = 201.064 mm2

Number of bars required, Nbar =


9

Because the number of bars is rounded up, make sure new reinforcement ratio < ρ max

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1809.577 mm2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.201 m
=

Reinforcement ratio, = 0.00462


From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 223.000 mm
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Isolated Footing 15

Input Values

Footing Geomtery

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 12 of 19

Design Type : Calculate Dimension


Footing Thickness (Ft) : 300.000 mm
Footing Length - X (Fl) : 1000.000 mm
Footing Width - Z (Fw) : 1000.000 mm
Eccentricity along X (Oxd) : 0.000 mm
Eccentricity along Z (Ozd) : 0.000 mm

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 0.300 m
Column Width - Z (Pw) : 0.300 m

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters
Concrete and Rebar Properties

Unit Weight of Concrete : 25.000 kN/m3


Strength of Concrete : 21.000 N/mm2
Yield Strength of Steel : 276.000 N/mm2
Minimum Bar Size : #16
Maximum Bar Size : #16
Minimum Bar Spacing : 50.000 mm
Maximum Bar Spacing : 500.000 mm
Pedestal Clear Cover (P, CL) : 75.000 mm
Footing Clear Cover (F, CL) : 75.000 mm

Soil Properties

Soil Type : Drained


Unit Weight : 22.000 kN/m3
Soil Bearing Capacity : 120.000 kN/m2
Soil Surcharge : 0.000 kN/m2
Depth of Soil above Footing : 1500.000 mm
Cohesion : 0.000 kN/m2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 13 of 19

Initial Length (Lo) = 1.000 m

Initial Width (Wo) = 1.000 m

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
16 GENERATED ACI TABLE1 9
17 GENERATED ACI TABLE1 10
18 GENERATED ACI TABLE1 11
19 GENERATED ACI TABLE1 12
20 GENERATED ACI TABLE1 13
21 GENERATED ACI TABLE1 14
22 GENERATED ACI TABLE1 15
23 GENERATED ACI TABLE1 16
24 GENERATED ACI TABLE1 17

Load Combination/s- Strength Level


Load Combination
Load Combination Title
Number
8 GENERATED ACI TABLE1 1
9 GENERATED ACI TABLE1 2
10 GENERATED ACI TABLE1 3
11 GENERATED ACI TABLE1 4
12 GENERATED ACI TABLE1 5
13 GENERATED ACI TABLE1 6
14 GENERATED ACI TABLE1 7
15 GENERATED ACI TABLE1 8

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kN) (kN) (kN) (kNm) (kNm)
16 174.607 14.322 -0.154 -0.045 -30.547
17 138.892 -15.451 0.376 0.739 31.058
18 160.993 -0.633 15.601 24.167 0.411
19 156.749 -0.565 0.111 0.347 0.256
20 106.067 0.046 0.049 0.219 -0.083
21 123.925 14.932 -0.216 -0.173 -30.886
22 88.210 -14.840 0.315 0.611 30.719
23 110.311 -0.023 15.539 24.039 0.072
24 106.067 0.046 0.049 0.219 -0.083

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kN) (kN) (kN) (kNm) (kNm)
8 164.994 0.071 0.077 0.341 -0.130
9 167.560 -0.765 0.140 0.387 0.387
10 165.945 -0.940 0.138 0.380 0.476
11 161.919 -0.004 0.117 0.370 -0.030
12 146.593 0.622 0.072 0.315 -0.398
13 156.749 -0.565 0.111 0.347 0.256
14 141.423 0.061 0.066 0.292 -0.111
15 158.365 -0.389 0.113 0.354 0.166

Reduction of force due to buoyancy = 0.000 kN


Effect due to adhesion = 0.000 kN
Area from initial length and width, Ao = L X W = 1.000 m2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 1.329 m 2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 14 of 19

Length (L2) = 1.600 m Governing Load Case : # 16

Width (W2) = 1.600 m Governing Load Case : # 16

Depth (D2) = 0.300 m Governing Load Case : # 16

Area (A2) = 2.560 m 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 (q corner 2 (q corner 3 (q corner 4 (q in uplift (A u )
Load Case ) ) ) )
1 2 3 4
(kN/m2) (kN/m2) (kN/m2) (kN/m2) (m 2)

17 144.6315 40.0589 42.5546 147.1272 0.000

16 56.6370 158.7177 158.4516 56.3708 0.000

16 56.6370 158.7177 158.4516 56.3708 0.000

17 144.6315 40.0589 42.5546 147.1272 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q 1 ) corner 2 (q 2) corner 3 (q 3 ) corner 4 (q 4 )

Load Case (kN/m2) (kN/m2) (kN/m2) (kN/m2)

17 144.6315 40.0589 42.5546 147.1272

16 56.6370 158.7177 158.4516 56.3708

16 56.6370 158.7177 158.4516 56.3708

17 144.6315 40.0589 42.5546 147.1272

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


- sliding overturning

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 15 of 19

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

16 9.612 891.058 2424.148 6.321

17 7.754 318.508 225.012 5.370

18 206.607 8.387 7.257 348.071

19 228.021 1161.601 541.298 484.305

20 2261.274 2098.745 706.926 1704.006

21 7.522 519.872 757.098 5.081

22 6.365 300.280 214.265 4.297

23 4574.953 6.790 5.882 2133.411

24 2261.274 2098.745 706.926 1704.006

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 22


Governing Disturbing Force : -14.840 kN
Governing Restoring Force : 94.458 kN
Minimum Sliding Ratio for the Critical Load Case : 6.365
Critical Load Case for Overturning about X-Direction : 23
Governing Overturning Moment : 28.701 kNm
Governing Resisting Moment : 168.811 kNm
Minimum Overturning Ratio for the Critical Load Case : 5.882

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 23


Governing Disturbing Force : 15.539 kN
Governing Restoring Force : 105.509 kN
Minimum Sliding Ratio for the Critical Load Case : 6.790
Critical Load Case for Overturning about Z-Direction : 22
Governing Overturning Moment : 35.171 kNm
Governing Resisting Moment : 151.130 kNm
Minimum Overturning Ratio for the Critical Load Case : 4.297

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 0.300m


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.200 m 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff , increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 242.111 kN, Load Case # 9

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 16 of 19

From ACI Cl.11.12.2.1, bo for column= 1.998 m

Equation 11-33, Vc1 = 910.674 kN

Equation 11-34, Vc2 = 909.946 kN

Equation 11-35, Vc3 = 607.116 kN

Punching shear strength, Vc = 0.75 X minimum of (V c1, Vc2, Vc3) = 455.337 kN

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, V c =

243.041 kN Distance along X to design for shear,


Dx = 1.150 m

Check that 0.75 X V c > V ux where V ux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 182.281 kN

Critical load case for Vux is # 9 75.843 kN

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, V c = 243.041 kN


Distance along X to design for shear, D z = 0.450 m

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 17 of 19

Check that 0.75 X Vc > Vuz where V uz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 182.281 kN

Critical load case for Vuz is # 9 75.984 kN

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 9

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.03765

From ACI Cl. 10.3.3, = 0.02824

From ACI Cl. 7.12.2, = 0.00200

From Ref. 1, Eq. 3.8.4a, constant m = 15.462

Calculate reinforcement ratio for critical load case


Design for flexure about Z axis is
performed at the face of the column at 0.650 m
a distance, Dx =

Ultimate moment, 35.641 kNm

Nominal moment capacity, Mn = 39.601 kNm

Required = 0.00229

Since OK

Area of Steel Required, As = 731.834 mm2

Selected bar Size = #16


Minimum spacing allowed (Smin) = = 50.000 mm

Selected spacing (S) = 478.000 mm


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 18 of 19

According to ACI 318-05 Clause No- 10.6.4


Max spacing for Cracking Consideration = 383.566 mm

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#16 @ 12065.000 mm o.c.

Required development length for bars = =0.305 m


Available development length for bars, D L
0.575 m
=
Try bar size # 16 Area of one bar = 201.064 mm2

Number of bars required, Nbar =


4

Because the number of bars is rounded up, make sure new reinforcement ratio < ρ max

Total reinforcement area, As_total = Nbar X (Area of one bar) = 804.256 mm2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.217 m
=

Reinforcement ratio, = 0.00232


From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 478.000 mm
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 9

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.03765

From ACI Cl. 10.3.3, = 0.02824

From ACI Cl.7.12.2, = 0.00200

From Ref. 1, Eq. 3.8.4a, constant m = 15.462

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019


Isolated Footing Design Page 19 of 19

Calculate reinforcement ratio for critical load case


Design for flexure about X axis is
performed at the face of the column at 0.650 m
a distance, Dz =

Ultimate moment, 35.574 kNm

Nominal moment capacity, Mn = 39.527 kNm

Required = 0.00271

Since OK

Area of Steel Required, As = 796.748 mm2

Selected Bar Size = #16


Minimum spacing allowed (Smin) = 50.000 mm

Selected spacing (S) = 478.000 mm


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 383.566 mm

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#16 @ 12065.000 mm o.c.

Required development length for bars = =0.305 m


Available development length for bars, D L
0.575 m
=
Try bar size # 16 Area of one bar = 201.064 mm2

Number of bars required, Nbar =


4

Because the number of bars is rounded up, make sure new reinforcement ratio < ρ max

Total reinforcement area, A s_total = Nbar X (Area of one bar) = 804.256 mm2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.201 m
=

Reinforcement ratio, = 0.00250


From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 478.000 mm
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml Monday, January 14, 2019

You might also like