Professional Documents
Culture Documents
COMPUTATIONS
Design by:
A. Scope
1. The numerical values of actions on buildings and civil Engineering works to be taken
into account in the design are applicable to the various types of construction.
2. The purpose of the building is residential building. The materials used are reinforced
concrete structures, cement blocks for walls and the roof are made up with steel
trusses covered with roofing sheet.
A. Design Reference
C. Material Stresses
D. Loadings
1. Dead Load
• Roof Sheet= 0.10 kPa
• Slab = 2.28kPa (for 120mm thk. Slab)
• Floor Finish = 1.20kPa
• Ceiling & MEP = 0.20kPa
• Interior Partition = 1.00kPa
• CHB 5” = 3.11kN/m per meter height
• CHB 4” = 2.98kN/m per meter height
2. Live Load
• Residential Floor Unit = 1.9kPa
• Deck = 1.9k
• Exterior Balconies = 2.9kPa
• Roof = 0.60kPa
3. Wind Load
• Wind Speed = 250 KpH
• Design Wind Pressure = qh[(GCpf)-(Gcpi)]
• Velocity Pressure = qh
• External Pressure Coefficient = (GCpf)
• Internal Pressure Coefficient = (GCpi)
E. Seismic Parameter
1. Assumed allowable soil bearing capacity of 300kPa. (to be verified by actual soil
testing)
2. Foundation design is subject to change based on the recommendation or soil
testing result.
A. Calculation and result are extracted in STAAD Advance Concrete Design. See
attached files.
1. Contents
• Footing Tie Beam Design Critical Member.
• 2nd, 3rd, and roof deck Beam Design Critical Member
A. Calculation and result are extracted in STAAD Advance Concrete Design. See
attached files.
1. Contents
• Design of Critical Column Member
A. Calculation and result are extracted in STAAD Advance Concrete Design. See
attached files.
1. Contents
• Suspended Slab design of two-way slab.
VIII. Foundation Design
A. Calculations and results are extracted in STAAD Foundation Advance. See attached
files.
1. Contents
• Foundation Design of 1.20mx1.20mx0.35m footing.
• Foundation Design of 1.40mx1.40mx0.35m footing.
IX. Three-Dimensional View
BEAM DESIGN
VI.
COLUMN DESIGN
VII.
SLAB DESIGN
VIII.
FOUNDATION DESIGN
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Job Information
Engineer Checked Approved
Name: JGarcia
Date: 12-May-22
Project ID
Project Name
Primary 1 EX
Primary 2 EZ
Primary 3 DL
Primary 4 LL
Combination 5 DL + LL
Combination 6 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 1
Combination 7 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 2
Combination 8 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 3
Combination 9 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 4
Combination 10 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 5
Combination 11 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 6
Combination 12 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 7
Combination 13 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 8
Combination 14 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 9
Combination 15 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 10
Combination 16 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 11
Combination 17 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 12
Combination 18 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 13
Combination 19 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION 14
Materials
Mat Name E Density
(kN/mm2) (kg/m3) (/°C)
1 STEEL 205.000 0.300 7.83E+3 12E -6
2 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
3 ALUMINUM 68.948 0.330 2.71E+3 23E -6
4 CONCRETE 21.718 0.170 2.4E+3 10E -6
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 1 of 22
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Supports
Node X Y Z rX rY rZ
(kN/mm) (kN/mm) (kN/mm) (kN-m/deg) (kN-m/deg) (kN-m/deg)
3 Fixed Fixed Fixed - - -
5 Fixed Fixed Fixed - - -
Releases
There is no data of this type.
1 EX Seismic
2 EZ Seismic
3 DL Dead
4 LL Live
5 DL + LL 3 DL 1.00
4 LL 1.00
6 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 1 1.40
7 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 2 1.20
4 LL 1.60
8 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 3 1.42
4 LL 0.50
1 EX 1.00
9 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 4 1.42
4 LL 0.50
2 EZ 1.00
10 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 5 1.42
4 LL 0.50
1 EX -1.00
11 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 6 1.42
4 LL 0.50
2 EZ -1.00
12 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 7 1.12
1 EX 1.00
13 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 8 1.12
2 EZ 1.00
14 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 9 1.12
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 2 of 22
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
1 EX -1.00
15 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 10 1.12
2 EZ -1.00
16 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 11 0.68
1 EX 1.00
17 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 12 0.68
2 EZ 1.00
18 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 13 0.68
1 EX -1.00
19 GENERATED NSCP 2015 SPECIAL LOAD COMBINATION
3 DL 14 0.68
2 EZ -1.00
1 EX : Seismic Loading
Code Direction Factor
UBC X 1.000
2 EZ : Seismic Loading
Code Direction Factor
UBC Z 1.000
3 DL : Reference Loads
Ref Name Factor
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 3 of 22
Job No Sheet No Rev
4
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 4 of 22
Job No Sheet No Rev
5
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 5 of 22
Job No Sheet No Rev
6
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 6 of 22
Job No Sheet No Rev
7
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 7 of 22
Job No Sheet No Rev
8
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 8 of 22
Job No Sheet No Rev
9
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 9 of 22
Job No Sheet No Rev
10
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 10 of 22
Job No Sheet No Rev
11
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 11 of 22
Job No Sheet No Rev
12
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 12 of 22
Job No Sheet No Rev
13
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 13 of 22
Job No Sheet No Rev
14
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 14 of 22
Job No Sheet No Rev
15
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 15 of 22
Job No Sheet No Rev
16
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 16 of 22
Job No Sheet No Rev
17
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 17 of 22
Job No Sheet No Rev
18
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 18 of 22
Job No Sheet No Rev
19
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 19 of 22
Job No Sheet No Rev
20
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 20 of 22
Job No Sheet No Rev
21
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 21 of 22
Job No Sheet No Rev
22
Part
Software licensed to
Job Title Two-Storey With Roof Deck Residential Building Ref
Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kN-m) (kN-m) (kN-m)
Max FX 3 18:GENERATED NSCP 2015 SPECIAL
18.476 97.140 LOAD 2.348
COMBINATION
0.000
13 0.000 0.000
Min FX 3 8:GENERATED NSCP 2015 SPECIAL
-19.591 201.009LOAD COMBINATION
4.703 0.000
3 0.000 0.000
Max FY 3 11:GENERATED NSCP
-1.080
2015 SPECIAL
217.538 LOAD 6.964
COMBINATION
0.000
6 0.000 0.000
Min FY 5 2:EZ 0.297 -12.483 -2.060 0.000 0.000 0.000
Max FZ 3 11:GENERATED NSCP
-1.080
2015 SPECIAL
217.538 LOAD 6.964
COMBINATION
0.000
6 0.000 0.000
Min FZ 3 2:EZ 0.317 -12.358 -2.075 0.000 0.000 0.000
Max MX 3 1:EX -18.828 -4.171 -0.187 0.000 0.000 0.000
Min MX 3 1:EX -18.828 -4.171 -0.187 0.000 0.000 0.000
Max MY 3 1:EX -18.828 -4.171 -0.187 0.000 0.000 0.000
Min MY 3 1:EX -18.828 -4.171 -0.187 0.000 0.000 0.000
Max MZ 3 1:EX -18.828 -4.171 -0.187 0.000 0.000 0.000
Min MZ 3 1:EX -18.828 -4.171 -0.187 0.000 0.000 0.000
Utilization Ratio
Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
15 Rect 0.40x0.20N/A 800.000 107E+3 26.7E+3 73.2E+3
16 Rect 0.40x0.20N/A 800.000 107E+3 26.7E+3 73.2E+3
29 Rect 0.40x0.20N/A 800.000 107E+3 26.7E+3 73.2E+3
30 Rect 0.40x0.20N/A 800.000 107E+3 26.7E+3 73.2E+3
35 Rect 0.40x0.20N/A 800.000 107E+3 26.7E+3 73.2E+3
Failed Members
There is no data of this type.
Print Time/Date: 13/05/2022 12:05 STAAD.Pro V8i (SELECTseries 6) 20.07.11.90 Print Run 22 of 22
Page 1 of 15
21 Asr = sqmm
Area of Compression reinforcement required for doubly
22 Asc =
reinforced section or if torsion exists in sqmm
23 b = Width of the Beam in mm
24 bw = Width of Web in mm
C/C distance between longitudinal reinforcement along B in
25 b' =
mm
26 bc = Oustside dimension of transverse reinforcement in mm
27 Cc = Effective Cover to tension reinforcement in mm
28 Cmin = Clear cover in mm
29 c' = Effective cover to reinforcement at compression face in mm
30 d = Effective depth of Beam in mm
C/C distance between longitudinal reinforcement along D in
31 d' =
mm
32 D = Depth of Beam in mm
33 Ec = Modulus of elasticity of concrete in N/sqmm
34 Es = Modulus of elasticity of steel in N/sqmm
Calculated tensile stress in reinforcement at service loads,
35 fs =
N/sqmm
36 Hf = Thickness of Flange in mm
Maximum C/C horizontal spacing of hoops legs on all faces in
37 hx =
mm
38 l = Effective Length of Beam in mm
39 Legs = Number of legs of the shear reinforcement
Hogging moments of resistance of member at the joint faces in
40 Mpr1 =
kNm
Sagging moments of resistance of member at the joint faces in
41 Mpr2 =
kNm
42 Mu = Factored Bending Moment at a section in kNm
Nominal flexural strength of Singly Reinforced Section At
43 Mubal =
Balance Neutral Axis in kNm
44 Ptmin = Minimum percentage steel as per clause 10.5
45 PtPrv = Provided percentage steel
46 Stirrup = Bar mark representing shear stirrup
47 S = spacing of confining links in mm
48 SCalc = Stirrup spacing calculated as per Asv in mm
49 Sprv = Stirrup spacing provided in mm
50 Tcr = Cracking torque under pure Torsion in kNm
51 Tu = Factored Torsional Moment at a section in kNm
52 Ve = Earthquake induced shear in kN
53 φVc = Nominal shear strength provided by concrete in kN
54 Vu = Factored Shear Force at a section in kN
55 Vu-A1(sway Left) = VD+Lleft - (Mpr1left + Mpr2right / L ) in kN
All Forces are In kN, kNm, Stress in N/sqmm & Dimension are in mm.
Code References
ACI 318M:2011
Sr.No. Item Clause / Table
1. Ptmax : 10.3.5
2. Ptmin : 10.5.1
3. Vc : 11.2
4. Asv : 11.4.7.2
5. Min Shear Reinf : 11.4.6
Max Stirrup
6. : 11.4.5.1
Spacing
Shear Reinf -
7. : 11.5.3.5
Torsion
Side Face
8. : 10.6.7
Reinforcement
9. Tcr : 11.5.1
Group : G2
Beam No : B5
Analysis Reference (Member) 3.1m : 34,38
Beam Length : 3103.99 mm
Breadth (B) : 200 mm
Depth (D) : 400 mm
Effective Depth (d) : 330 mm
Design Code : ACI 318M - 2011
Beam Type : Regular Beam
Grade Of Concrete (Fck) : C21 N/sqmm
Grade Of Steel : Fy415 N/sqmm
Basic
Spc1 = 200 mm
Spc2 = 115 mm
Skin reinforcement
Group : G2
Beam No : B6
Analysis Reference (Member) 3.1m : 35,42
Beam Length : 2999.99 mm
Breadth (B) : 200 mm
Depth (D) : 400 mm
Effective Depth (d) : 330 mm
Design Code : ACI 318M - 2011
Beam Type : Regular Beam
Grade Of Concrete (Fck) : C21 N/sqmm
Grade Of Steel : Fy415 N/sqmm
Clear Cover (Cmin) : 40 mm
Es : 2x10^5 N/sqmm
Mubal : 115.92 kNm
As,min (flex) (B) : 222.65 sqmm
Legs 2 2 2
Stirrup Rebar 10 10 10
Asv Torsion (sqmm) 0 0 0
Av Total Reqd (sqmm) 168.67 168.67 168.67
Asv Reqd (sqmm) 168.675 168.675 168.675
SCalc (mm) 115 115 115
SPrv (mm) 115 115 115
Av Total Prv (sqmm) 1365.91 1365.91 1365.91
Basic
Spc1 = 200 mm
Spc2 = 115 mm
Skin reinforcement
Group : G2
Beam No : B7
Analysis Reference (Member) 3.1m : 36,44
Beam Length : 2999.99 mm
Breadth (B) : 200 mm
Depth (D) : 400 mm
Effective Depth (d) : 330 mm
Design Code : ACI 318M - 2011
Beam Type : Regular Beam
Grade Of Concrete (Fck) : C21 N/sqmm
Grade Of Steel : Fy415 N/sqmm
Clear Cover (Cmin) : 40 mm
Es : 2x10^5 N/sqmm
Mubal : 115.92 kNm
As,min (flex) (B) : 222.65 sqmm
As,nominal (Bn) : 85.8 sqmm
Basic
Spc1 = 200 mm
Spc2 = 115 mm
Skin reinforcement
Group : G2
Beam No : B8
Analysis Reference (Member) 3.1m : 37
Beam Length : 1935 mm
Breadth (B) : 200 mm
Depth (D) : 400 mm
Effective Depth (d) : 330 mm
Design Code : ACI 318M - 2011
Beam Type : Regular Beam
Grade Of Concrete (Fck) : C21 N/sqmm
Grade Of Steel : Fy415 N/sqmm
Clear Cover (Cmin) : 40 mm
Es : 2x10^5 N/sqmm
Mubal : 115.92 kNm
As,min (flex) (B) : 222.65 sqmm
As,nominal (Bn) : 85.8 sqmm
Basic
Spc1 = 200 mm
Spc2 = 115 mm
Skin reinforcement
Spacing Criteria
Group : G12
Beam No : B24
Analysis Reference (Member) 3.1m : 28
Beam Length : 1050 mm
Breadth (B) : 200 mm
Depth (D) : 400 mm
Effective Depth (d) : 330 mm
Design Code : ACI 318M - 2011
Beam Type : Cantilever Beam
Grade Of Concrete (Fck) : C21 N/sqmm
Grade Of Steel : Fy415 N/sqmm
Clear Cover (Cmin) : 40 mm
Es : 2x10^5 N/sqmm
Mubal : 115.92 kNm
As,min (flex) (B) : 222.65 sqmm
As,nominal (Bn) : 85.8 sqmm
Basic
Spc1 =d/2 = 165 mm
Spc2 = 300 mm
Skin reinforcement
Group : G12
Beam No : B25
Analysis Reference (Member) 3.1m : 48,33,19
Beam Length : 5799.99 mm
Breadth (B) : 200 mm
Depth (D) : 400 mm
Effective Depth (d) : 330 mm
Design Code : ACI 318M - 2011
Beam Type : Ductile Beam (Special Frame)
Grade Of Concrete (Fck) : C21 N/sqmm
Grade Of Steel : Fy415 N/sqmm
Clear Cover (Cmin) : 40 mm
Es : 2x10^5 N/sqmm
Mubal : 115.92 kNm
As,min (flex) (B) : 222.65 sqmm
As,nominal (Bn) : 85.8 sqmm
Basic
Spc1 = 200 mm
Spc2 = 115 mm
= 96 mm
Spc3 = 6 x Small Longitudinal Dia
Spc4 = d / 4 = 82 mm
Spc5 = 150 mm
Provided Spacing = 100 mm
Mid Section
Provided Spacing = 165 mm
Skin reinforcement
Spacing Criteria
21 Asr = sqmm
Area of Compression reinforcement required for doubly
22 Asc =
reinforced section or if torsion exists in sqmm
23 b = Width of the Beam in mm
24 bw = Width of Web in mm
C/C distance between longitudinal reinforcement along B in
25 b' =
mm
26 bc = Oustside dimension of transverse reinforcement in mm
27 Cc = Effective Cover to tension reinforcement in mm
28 Cmin = Clear cover in mm
29 c' = Effective cover to reinforcement at compression face in mm
30 d = Effective depth of Beam in mm
C/C distance between longitudinal reinforcement along D in
31 d' =
mm
32 D = Depth of Beam in mm
33 Ec = Modulus of elasticity of concrete in N/sqmm
34 Es = Modulus of elasticity of steel in N/sqmm
Calculated tensile stress in reinforcement at service loads,
35 fs =
N/sqmm
36 Hf = Thickness of Flange in mm
Maximum C/C horizontal spacing of hoops legs on all faces in
37 hx =
mm
38 l = Effective Length of Beam in mm
39 Legs = Number of legs of the shear reinforcement
Hogging moments of resistance of member at the joint faces in
40 Mpr1 =
kNm
Sagging moments of resistance of member at the joint faces in
41 Mpr2 =
kNm
42 Mu = Factored Bending Moment at a section in kNm
Nominal flexural strength of Singly Reinforced Section At
43 Mubal =
Balance Neutral Axis in kNm
44 Ptmin = Minimum percentage steel as per clause 10.5
45 PtPrv = Provided percentage steel
46 Stirrup = Bar mark representing shear stirrup
47 S = spacing of confining links in mm
48 SCalc = Stirrup spacing calculated as per Asv in mm
49 Sprv = Stirrup spacing provided in mm
50 Tcr = Cracking torque under pure Torsion in kNm
51 Tu = Factored Torsional Moment at a section in kNm
52 Ve = Earthquake induced shear in kN
53 φVc = Nominal shear strength provided by concrete in kN
54 Vu = Factored Shear Force at a section in kN
55 Vu-A1(sway Left) = VD+Lleft - (Mpr1left + Mpr2right / L ) in kN
All Forces are In kN, kNm, Stress in N/sqmm & Dimension are in mm.
Code References
ACI 318M:2011
Sr.No. Item Clause / Table
1. Ptmax : 10.3.5
2. Ptmin : 10.5.1
3. Vc : 11.2
4. Asv : 11.4.7.2
5. Min Shear Reinf : 11.4.6
Max Stirrup
6. : 11.4.5.1
Spacing
Shear Reinf -
7. : 11.5.3.5
Torsion
Side Face
8. : 10.6.7
Reinforcement
9. Tcr : 11.5.1
Group : G2
Beam No : B5
Analysis Reference (Member) 6.1m : 72,76
Beam Length : 3103.99 mm
Breadth (B) : 200 mm
Depth (D) : 300 mm
Effective Depth (d) : 270 mm
Design Code : ACI 318M - 2011
Beam Type : Regular Beam
Grade Of Concrete (Fck) : C21 N/sqmm
Grade Of Steel : Fy415 N/sqmm
Vs (kN) - - -
Av (sqmm) 168.67 168.67 168.67
Tu (kNm) 0.94 0.94 0.94
Ao= Φ*Aoh - - -
At (sqmm) - - -
Legs 2 2 2
Stirrup Rebar 10 10 10
Asv Torsion (sqmm) 0 0 0
Av Total Reqd (sqmm) 168.67 168.67 168.67
Asv Reqd (sqmm) 168.675 168.675 168.675
SCalc (mm) 110 110 110
SPrv (mm) 110 110 110
Av Total Prv (sqmm) 1428 1428 1428
Basic
Spc1 = 200 mm
Spc2 = 110 mm
Skin reinforcement
Spacing Criteria
Group : G2
Beam No : B6
Analysis Reference (Member) 6.1m : 73,80
Beam Length : 2999.99 mm
Basic
Spc1 = 200 mm
Spc2 = 110 mm
Skin reinforcement
Group : G2
Beam No : B7
Analysis Reference (Member) 6.1m : 74,82
Beam Length : 2999.99 mm
Breadth (B) : 200 mm
Depth (D) : 300 mm
Effective Depth (d) : 270 mm
Design Code : ACI 318M - 2011
Beam Type : Regular Beam
Grade Of Concrete (Fck) : C21 N/sqmm
Grade Of Steel : Fy415 N/sqmm
Clear Cover (Cmin) : 20 mm
Es : 2x10^5 N/sqmm
Mubal : 77.6 kNm
As,min (flex) (B) : 182.17 sqmm
As,nominal (Bn) : 70.2 sqmm
Basic
Spc1 = 200 mm
Spc2 = 110 mm
Skin reinforcement
Spacing Criteria
Group : G2
Beam No : B8
Analysis Reference (Member) 6.1m : 75
Beam Length : 1935 mm
Breadth (B) : 200 mm
Depth (D) : 300 mm
Effective Depth (d) : 270 mm
Basic
Spc1 = 200 mm
Spc2 = 110 mm
Skin reinforcement
Spacing Criteria
Group : G12
Beam No : B24
Basic
Spc1 =d/2 = 125 mm
Spc2 = 300 mm
Skin reinforcement
Group : G12
Beam No : B25
Analysis Reference (Member) 6.1m : 86,71,58
Beam Length : 5799.99 mm
Breadth (B) : 200 mm
Depth (D) : 300 mm
Effective Depth (d) : 250 mm
Design Code : ACI 318M - 2011
Beam Type : Ductile Beam (Special Frame)
Basic
Spc1 =d/2 = 200 mm
Spc2 = 110 mm
= 72 mm
Spc3 = 6 x Small Longitudinal Dia
Spc4 = d / 4 = 62 mm
Spc5 = 150 mm
Provided Spacing = 100 mm
Mid Section
Provided Spacing = 125 mm
Skin reinforcement
Load Combinations :
1. (LOAD 3: DL) +(LOAD 4: LL)
2. 1.4 (LOAD 3: DL)
3. 1.2 (LOAD 3: DL) +1.6 (LOAD 4: LL)
4. 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 1: EX)
5. 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 2: EZ)
6. 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -(LOAD 1: EX)
7. 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -(LOAD 2: EZ)
8. 1.12 (LOAD 3: DL) +(LOAD 1: EX)
9. 1.12 (LOAD 3: DL) +(LOAD 2: EZ)
10. 1.12 (LOAD 3: DL) -(LOAD 1: EX)
11. 1.12 (LOAD 3: DL) -(LOAD 2: EZ)
12. 0.68 (LOAD 3: DL) +(LOAD 1: EX)
13. 0.68 (LOAD 3: DL) +(LOAD 2: EZ)
14. 0.68 (LOAD 3: DL) -(LOAD 1: EX)
15. 0.68 (LOAD 3: DL) -(LOAD 2: EZ)
Levels : 1. FOUNDATION
2. 3.1m
3. 6.1m
Column/Wall : C1
Level Size Material LC Analysis P Mx My Pt Interaction Main Links
(mm) LC No (kN) (kNm) (kNm) (%) Ratio Reinforcement
1 TO 250 X C21 :
7 11 173.81 110.1 -0.06 1.29 0.78 8-#16 #10 @ 250
2 500 Fy415
2 TO 250 X C21 :
7 11 49.27 -55.35 4.06 1.29 0.44 8-#16 #10 @ 250
3 500 Fy415
Column/Wall : C2
Level Size Material LC Analysis P Mx My Pt Interaction Main Links
(mm) LC No (kN) (kNm) (kNm) (%) Ratio Reinforcement
1 TO 250 X C21 :
12 16 82.62 -59.46 6.12 1.29 0.46 8-#16 #10 @ 250
2 500 Fy415
2 TO 250 X C21 :
7 11 74.2 -6.55 54.77 1.29 0.93 8-#16 #10 @ 250
3 500 Fy415
Column/Wall : C3
Level Size Material LC Analysis P Mx My Pt Interaction Main Links
(mm) LC No (kN) (kNm) (kNm) (%) Ratio Reinforcement
1 TO 250 X C21 :
14 18 67.43 55.69 6.54 1.29 0.44 8-#16 #10 @ 250
2 500 Fy415
2 TO 250 X C21 :
7 11 63.64 -1.06 48.77 1.29 0.85 8-#16 #10 @ 250
3 500 Fy415
Column/Wall : C4
Level Size Material LC Analysis P Mx My Pt Interaction Main Links
(mm) LC No (kN) (kNm) (kNm) (%) Ratio Reinforcement
1 TO 250 X C21 :
12 16 65.05 -13.1 -23.99 1.29 0.38 8-#16 #10 @ 250
2 500 Fy415
2 TO 250 X C21 :
7 11 68.53 63.7 5.96 1.29 0.5 8-#16 #10 @ 250
3 500 Fy415
Column/Wall : C5
Level Size Material LC Analysis P Mx My Pt Interaction Main Links
(mm) LC No (kN) (kNm) (kNm) (%) Ratio Reinforcement
1 TO 250 X C21 :
14 18 6.26 -9.57 -42.04 1.29 0.74 8-#16 #10 @ 250
2 500 Fy415
2 TO 250 X C21 :
4 8 44.87 27.75 5.61 1.29 0.23 8-#16 #10 @ 250
3 500 Fy415
Column/Wall : C6
Column/Wall : C7
Level Size Material LC Analysis P Mx My Pt Interaction Main Links
(mm) LC No (kN) (kNm) (kNm) (%) Ratio Reinforcement
1 TO 250 X C21 :
12 16 113.85 8.91 -24.68 1.29 0.41 8-#16 #10 @ 250
2 500 Fy415
2 TO 250 X C21 :
5 9 92.1 63.26 -4.17 1.29 0.48 8-#16 #10 @ 250
3 500 Fy415
Column/Wall : C8
Level Size Material LC Analysis P Mx My Pt Interaction Main Links
(mm) LC No (kN) (kNm) (kNm) (%) Ratio Reinforcement
1 TO 250 X C21 :
12 16 94.4 8.81 -23.09 1.29 0.38 8-#16 #10 @ 250
2 500 Fy415
2 TO 250 X C21 :
5 9 101.19 -59.47 2.45 1.29 0.45 8-#16 #10 @ 250
3 500 Fy415
Column/Wall : C9
Level Size Material LC Analysis P Mx My Pt Interaction Main Links
(mm) LC No (kN) (kNm) (kNm) (%) Ratio Reinforcement
1 TO 250 X C21 :
4 8 207.17 28.91 -22.36 1.29 0.34 8-#16 #10 @ 250
2 500 Fy415
2 TO 250 X C21 :
5 9 67.76 -58.86 9.42 1.29 0.47 8-#16 #10 @ 250
3 500 Fy415
Column/Wall : C10
Level Size Material LC Analysis P Mx My Pt Interaction Main Links
(mm) LC No (kN) (kNm) (kNm) (%) Ratio Reinforcement
1 TO 250 X C21 :
12 16 50.69 13.03 37.8 1.29 0.64 8-#16 #10 @ 250
2 500 Fy415
2 TO 250 X C21 :
6 10 32.42 -28.27 14.7 1.29 0.29 8-#16 #10 @ 250
3 500 Fy415
Definitions Of Terms:
All forces in units kN and m
All reinforcement details like area, spacing in mm
Neutral axis angle for resultant design moment is with respect to local major axis.
Ratio to account for reduction of stiffness of columns
1 βdns =
due to sustained axial loads
Moment magnification factor for frames not braced
2 δns =
against sidesway
First-order relative deflection between the top and
3 Δo =
bottom of the story due to Vu in mm
Total factored vertical load in the story corresponding
4 ∑Pu = to the lateral loading case for which ∑Pu is greatest,
kN (Clause 10.10.5)
5 δu = Design displacement in mm
Modification factor reflecting the reduced mechanical
6 λ =
properties of lightweight concrete
7 Φ = Strength reduction factor
Coefficient defining the relative contribution of
8 ac =
concrete strength to nominal wall shear strength
Cross-sectional area of a structural member measured
9 Ach = to the outside edges of transverse reinforcement in
sqmm
Gross area of concrete section bounded by web
10 Acv = thickness and length of section in the direction of
shear force considered in sqmm
Effective cross-sectional area within a joint in a plane
11 Aj = parallel to plane of reinforcement generating shear in
the joint in sqmm
Area of non-prestressed longitudinal tension
12 As =
reinforcement in sqmm
Minimum area of shear reinforcement within spacing
13 Avmin =
's' in sqmm
14 B = Width of column/ wall in mm
15 B' = width of beam along B / column width in mm
Cross-sectional dimension of member core measured
16 bc = to the outside edges of the transverse reinforcement
composing area Ash in mm
Code References:
ACI 318M-2011
Sr.No Element Clause / table
Minimum area of longitudinal reinforcement
1 : 21.6.3
for column
Maximum area of longitudinal
2 : 21.6.3
reinforcement for column
Minimum longitudinal and transverse
3 : 21.9.2.1
reinforcement for wall
4 Minimum diameter of transverse ties : 7.10.5
5 Minimum spacing of transverse ties : 7.10.5
Maximum spacing of longitudinal and
6 : 21.9.2.1
transverse reinforcement for wall
7 Applicability of boundary element : 21.9.6
Area and spacing of special confining
8 : 21.6.4
reinforcement
9 Slenderness Moments : 10.10
Shear Strength provided by concrete for
10 : 11.2
column
11 Design of shear for non-ductile wall : 11.9
12 Design of shear for ductile wall : 21.9.4
13 Minimum Flexural Strength of Columns : 21.6.2.2
14 Shear Check at Column Joint : 21.7.4.1
15 Shear Strength of Column : 21.3.3 & 21.5.4
General Data
Column No. : C2
Level : 0m To 3.1m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy415 N/sqmm
Consider Ductile = No
Column B = 250 mm
Column D = 500 mm
Clear Cover = 50 mm
Clear Floor Height @ lux = 2700 mm
Clear Floor Height @ luy = 2700 mm
No Of Floors = 1
No Of Columns In Group = 1
Load Data
Analysis Reference No. = 3
Critical Analysis Load Combination : 16
Load Combination = [12] : 0.68 (LOAD 3: DL) +(LOAD 1: EX)
Critical Location = Top Joint
Put = 82.62 kN
Muxt = -59.46 kNm
Muyt = 6.12 kNm
Vuxt = 1.97 kN
Vuyt = 19.19 kN
Pub = 88.83 kN
Muxb = 0 kNm
Muyb = 0 kNm
Vuxb = 1.97 kN
Vuyb = 19.19 kN
Along B
Q = 0.011
0.011< 0.05, Column shall be designed as non-sway frame
(Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 16.27
M1 = 0 kNm
M2 = -59.46 kNm
34 - 12 x (M1/M2) = 34
16.27 < 34, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 72.17 mm
Klux /r = 32.55
M1 = 0 kNm
M2 = 6.12 kNm
34 - 12 x (M1/M2) = 34
32.55 < 34, Column not slender along B
Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 11
[7] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4:
Critical Load Combination = kN
LL) -(LOAD 2: EZ)
Nu = 217.63 kN
Muy = 0 kNm
Vuy = 1.0803 kN
λ = 1
φ = 0.65
deff = 442 mm
ρw = 0.006
mm = 15.18 kNm
Vcy Permissible = 180.15 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm
General Data
Column No. : C2
Level : 3.1m To 6.1m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy415 N/sqmm
Consider Ductile = No
Column B = 250 mm
Column D = 500 mm
Clear Cover = 50 mm
Clear Floor Height @ lux = 2700 mm
Clear Floor Height @ luy = 2700 mm
No Of Floors = 1
No Of Columns In Group = 1
Load Data
Analysis Reference No. = 89
Critical Analysis Load Combination : 11
[7] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -(LOAD
Load Combination =
2: EZ)
Critical Location = Top Joint
Put = 74.2 kN
Muxt = -6.55 kNm
Muyt = 54.77 kNm
Vuxt = 35.76 kN
Vuyt = 4.64 kN
Pub = 86.75 kN
Muxb = 7.38 kNm
Muyb = -52.49 kNm
Vuxb = 35.76 kN
Vuyb = 4.64 kN
Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 18.71
M1 = -6.55 kNm
M2 = 7.38 kNm
34 - 12 x (M1/M2) = 44.65
18.71 < 44.65, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 72.17 mm
Klux /r = 37.41
M1 = -52.49 kNm
M2 = 54.77 kNm
34 - 12 x (M1/M2) = 45.5
37.41 < 45.5, Column not slender along B
Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 7
[3] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4:
Critical Load Combination = kN
LL)
Nu = 82.75 kN
Muy = 3.55 kNm
Vuy = 2.466 kN
λ = 1
φ = 0.65
deff = 442 mm
ρw = 0.006
mm = 2.22 kNm
Vcy Permissible = 160.33 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4 mm
General Data
Column No. : C5
Level : 0m To 3.1m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy415 N/sqmm
Consider Ductile = No
Column B = 250 mm
Column D = 500 mm
Clear Cover = 50 mm
Clear Floor Height @ lux = 2700 mm
Clear Floor Height @ luy = 2700 mm
No Of Floors = 1
No Of Columns In Group = 1
Load Data
Analysis Reference No. = 9
Critical Analysis Load Combination : 18
Load Combination = [14] : 0.68 (LOAD 3: DL) -(LOAD 1: EX)
Critical Location = Bottom Joint
Put = 0.04 kN
Muxt = -5.15 kNm
Muyt = 33.72 kNm
Vuxt = 24.45 kN
Vuyt = -1.43 kN
Pub = 6.26 kN
Muxb = -9.57 kNm
Muyb = -42.04 kNm
Vuxb = 24.45 kN
Vuyb = -1.43 kN
Along B
Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 16.27
M1 = -5.15 kNm
M2 = -9.57 kNm
34 - 12 x (M1/M2) = 27.54
16.27 < 27.54, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.75
r = 72.17 mm
Klux /r = 28.06
M1 = 33.72 kNm
M2 = -42.04 kNm
34 - 12 x (M1/M2) = 43.63
28.06 < 43.63, Column not slender along B
Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 0.68 (LOAD 3: DL) -(LOAD 2:
Critical Load Combination = kN
EZ)
Nu = 61.11 kN
Muy = 39.21 kNm
Vuy = 38.0867 kN
λ = 1
φ = 0.65
deff = 442 mm
ρw = 0.006
mm = 34.94 kNm
Vcy Permissible = 86.21 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm
General Data
Column No. : C5
Level : 3.1m To 6.1m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy415 N/sqmm
Consider Ductile = No
Column B = 250 mm
Column D = 500 mm
Clear Cover = 50 mm
Clear Floor Height @ lux = 2700 mm
Clear Floor Height @ luy = 2700 mm
No Of Floors = 1
No Of Columns In Group = 1
Load Data
Analysis Reference No. = 94
Critical Analysis Load Combination : 8
[4] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD
Load Combination =
1: EX)
Critical Location = Bottom Joint
Put = 32.31 kN
Muxt = -21.18 kNm
Muyt = -10.23 kNm
Vuxt = -5.28 kN
Vuyt = 16.31 kN
Pub = 44.87 kN
Muxb = 27.75 kNm
Along B
Q = 0.006
0.006< 0.05, Column shall be designed as non-sway frame
(Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 18.71
M1 = -21.18 kNm
M2 = 27.75 kNm
34 - 12 x (M1/M2) = 43.16
18.71 < 43.16, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.75
r = 72.17 mm
Klux /r = 28.06
M1 = 5.61 kNm
M2 = -10.23 kNm
34 - 12 x (M1/M2) = 40.58
28.06 < 40.58, Column not slender along B
Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 0.68 (LOAD 3: DL) +(LOAD 2:
Critical Load Combination = kN
EZ)
Nu = 6.41 kN
Muy = 0.43 kNm
Vuy = 3.8188 kN
λ = 1
φ = 0.65
deff = 442 mm
ρw = 0.006
mm = 0.01 kNm
Vcy Permissible = 147.94 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm
General Data
Column No. : C8
Level : 0m To 3.1m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy415 N/sqmm
Consider Ductile = No
Column B = 250 mm
Column D = 500 mm
Clear Cover = 50 mm
Clear Floor Height @ lux = 2700 mm
Clear Floor Height @ luy = 2700 mm
No Of Floors = 1
No Of Columns In Group = 1
Load Data
Analysis Reference No. = 6
Critical Analysis Load Combination : 16
Load Combination = [12] : 0.68 (LOAD 3: DL) +(LOAD 1: EX)
Critical Location = Top Joint
Put = 94.4 kN
Muxt = 8.81 kNm
Muyt = -23.09 kNm
Vuxt = -7.45 kN
Vuyt = -2.84 kN
Pub = 100.61 kN
Muxb = 0 kNm
Muyb = 0 kNm
Vuxb = -7.45 kN
Vuyb = -2.84 kN
Along B
Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 16.27
M1 = 0 kNm
M2 = 8.81 kNm
34 - 12 x (M1/M2) = 34
16.27 < 34, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.74
r = 72.17 mm
Klux /r = 27.69
M1 = 0 kNm
M2 = -23.09 kNm
34 - 12 x (M1/M2) = 34
27.69 < 34, Column not slender along B
Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
Pt Calculated = 1.29
Reinforcement Provided = 8-#16
Load Angle = Tan-1(Muy/Mux)
= 69.11 deg
MRes = 24.71 kNm
( φ ) MCap = 65 kNm
Capacity Ratio = MRes/ MCap
= 0.38 < 1
Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 9
[5] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4:
Critical Load Combination = kN
LL) +(LOAD 2: EZ)
Nu = 251.11 kN
Muy = 0 kNm
Vuy = -8.6171 kN
λ = 1
φ = 0.65
deff = 442 mm
ρw = 0.006
mm = 17.51 kNm
Vcy Permissible = 184.74 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm
General Data
Column No. : C8
Level : 3.1m To 6.1m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy415 N/sqmm
Consider Ductile = No
Column B = 250 mm
Column D = 500 mm
Clear Cover = 50 mm
Clear Floor Height @ lux = 2700 mm
Clear Floor Height @ luy = 2700 mm
No Of Floors = 1
No Of Columns In Group = 1
Load Data
Analysis Reference No. = 95
Critical Analysis Load Combination : 9
[5] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD
Load Combination =
2: EZ)
Critical Location = Bottom Joint
Put = 88.63 kN
Muxt = 58.62 kNm
Muyt = -2.48 kNm
Vuxt = -1.64 kN
Vuyt = -39.37 kN
Pub = 101.19 kN
Muxb = -59.47 kNm
Muyb = 2.45 kNm
Vuxb = -1.64 kN
Vuyb = -39.37 kN
Along B
Q = 0.006
0.006< 0.05, Column shall be designed as non-sway frame
(Braced)
Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 18.71
M1 = 58.62 kNm
M2 = -59.47 kNm
34 - 12 x (M1/M2) = 45.83
18.71 < 45.83, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.72
r = 72.17 mm
Klux /r = 26.94
M1 = 2.45 kNm
M2 = -2.48 kNm
34 - 12 x (M1/M2) = 45.84
26.94 < 45.84, Column not slender along B
Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))
Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 7
[3] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4:
Critical Load Combination = kN
LL)
Nu = 100.67 kN
Muy = 44.05 kNm
Vuy = -32.3509 kN
λ = 1
φ = 0.65
deff = 442 mm
ρw = 0.006
mm = 37.03 kNm
Vcy Permissible = 84.94 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm
NOTES:
1. Density of concrete assumed as 25 kN/Cum.
Definitions Of Terms: :
Ratio of flexural stiffness of beam section to flexural
1. αf =
stiffness of slab.
Ratio of torsional stiffness of edge beam section to
2. βt =
flexural stiffness of slab.
3. Φt = Strength reduction factor.
4. As = Area of Tension reinforcement required in sqmm.
5. As,min = Min area of flexural reinforcement in sqmm.
Area of longitudinal reinforcement provided at given
6. AstPrv =
section in sqmm.
Total area of longitudinal reinforcement calculated at a
7. Ast =
given section in sqmm.
8. b = Width of the Slab in mm.
9. B1 to B4 = Width of beams around slab in mm.
10. Cc = Effective Cover to tension reinforcement in mm.
11. deff = Effective depth of slab in mm.
12. D1 to D4 = Depth of beams around slab.
13. Mu = Factored Bending Moment at a section in kNm.
14. Ptmin = Minimum percentage steel as per clause 10.
15. PtPrv = Provided percentage steel.
16. Vc = Nominal shear strength provided by concrete in kN.
17. Vu = Factored Shear Force at a section in kN.
18. Vud = Design Shear Force in kN.
Length of clear span in direction that moment are
19. Ln =
being determined in mm.
20. L2 = Length of adjacent span of Ln in mm.
21. lb1 to lb2 = Moment of inertia of beams around slab in mm4.
cross-sectional constant to define torsional properties
22. CA and CB =
of slab and beam.
Code References :
ACI 318M:2011
Slab No. : S2
Level = 3.1m
Design Code = ACI 318 - 2011
Grade Of Concrete = C21
Grade Of Steel = Fy275
Clear Cover = 20.000 mm
Long Span, Ly = 1.900 m
Short Span, Lx = 1.600 m
Imposed Load = 2.400 kN/sqm
Live Load, Qk = 1.900 kN/sqm
Slab Thickness = 100.000 mm
Effective Depth Along LX, Deffx = 75.000 mm
Effective Depth Along LY, Deffy = 65.000 mm
Self Weight = 2.500 kN/sqm
Total Load, TL (ultimate) = 8.920 kN/sqm
Span = 2-Way
Load Combination = 1.2 DL + 1.6 LL
Design Moments:
Short Span Positive Moment At Midspan -
M1 = 0.201 kNm
Area Of Reinforcement = 10.818 kN/sqmm
Required (BM)
Reinforcement Provided = #10 @ 150 C/C
= 524.000 kN/sqmm
Short Span Negative Moment At Continuous Support -
M2 = N.A. kNm
Area Of Reinforcement = N.A. kN/sqmm
Required (BM)
Reinforcement Provided = N.A.
= N.A. kN/sqmm
Long Span Positive Moment At Midspan -
M3 = 0.172 kNm
Area Of Reinforcement = 10.706 kN/sqmm
Required (BM)
Reinforcement Provided = #10 @ 150 C/C
= 524.000 kN/sqmm
Long Span Negative Moment At Continuous Support -
M4 = 0.211 kNm
Area Of Reinforcement = 13.152 kN/sqmm
Required (BM)
Reinforcement Provided = #10 @ 150 C/C
= 524.000 kN/sqmm
Shear Check :
Along Short Span
Vsx (TL(ultimate) x Lx / 4) = 3.568 kN
Nominal Shear, Vc = 58.428 kN
> 3.568 Slab Is Safe In Shear
Along Long Span
Vsy (TL(ultimate) x Lx / 2 x (1 = 4.131 kN
- (Lx / (2 x Ly))))
Nominal Shear, Vc = 50.637 kN
> 4.131 Slab Is Safe In Shear
Design Moments:
Short Span Positive Moment At Midspan -
M1 = 0.663 kNm
Area Of Reinforcement = 28.250 kN/sqmm
Required (BM)
Reinforcement Provided = #10 @ 185 C/C
= 425.000 kN/sqmm
Short Span Negative Moment At Continuous Support -
M2 = 1.231 kNm
Area Of Reinforcement = 52.568 kN/sqmm
Required (BM)
Reinforcement Provided = #10 @ 185 C/C
= 425.000 kN/sqmm
Long Span Positive Moment At Midspan -
M3 = 2.168 kNm
Area Of Reinforcement = 104.017 kN/sqmm
Required (BM)
Reinforcement Provided = #10 @ 185 C/C
= 425.000 kN/sqmm
Long Span Negative Moment At Continuous Support -
M4 = N.A. kNm
Area Of Reinforcement = N.A. kN/sqmm
Required (BM)
Reinforcement Provided = N.A.
= N.A. kN/sqmm
Distribution Reinforcement @ 0.18% -
Area Of Reinforcement = 171.000 sqmm
Required
Reinforcement Provided = #10 @ 185 C/C
= 425.000 kN/sqmm
Shear Check :
Along Short Span
Vsx (TL(ultimate) x Lx / 4) = 7.140 kN
Nominal Shear, Vc = 74.009 kN
> 7.140 Slab Is Safe In Shear
Along Long Span
Vsy (TL(ultimate) x Lx / 2 x (1 = 8.788 kN
- (Lx / (2 x Ly))))
Nominal Shear, Vc = 66.218 kN
> 8.788 Slab Is Safe In Shear
Definitions:
1. A = Plan area of footing base in sqmm
2. Ast (min) = Area of longitudinal reinforcement as per code cl. 7.12.2.1
in sqmm
3. Ast Prv = Area of tensile reinforcement provided in sqmm
4. Ast Rqd = Area of longitudinal reinforcement from bearing moment
and minimum % steel provided by user and as per code cl
7.12.2.1 in sqmm
5. Av = Area of shear reinforcement required in sqmm
6. AvPrv = Area of shear reinforcement provided in sqmm
7. A1 = Bearing area of footing at slope of 1:2 in sqmm
8. A2 = C/s Area of column in sqmm
9. B = Width of footing base in mm
10. Beff = Effective width of footing in mm
11. Boff = Footing offset along B in mm
12. BoffB = Footing offset along B above column in plan
13. BoffT = Footing offset along B below column in plan
14. B1 = Width of sloped footing at top in mm
15. ColOff = Column offset in sloped footing in mm
16. D = Depth of footing in mm
17. d = Effective Depth of footing in mm
18. Dfd = Depth of founding layer in m
19. Dw = Ground water level in m
20. Ec = Modulus of elasticity of concrete in N/sqmm
21. Es = Modulus of elasticity of steel in N/sqmm
22. Foss = Safety factor against sliding
23. Fosu = Safety factor against uplift
24. Fst = Stress in steel in N/sqmm
25. F'c = Characteristic strength of concrete in N/sqmm
26. L = Length of footing base in mm
27. Leff = Effective length of footing in mm
28. Loff = Footing offset along L in mm
Code References:
ACI 318M:2011
Sr.No. Item Clause / Table
1. Ptmax : 10.3.5
2. Ptmin : 7.12.2.1/10.5.4
3. Vc : 11.11.2.1
4. Av : 11.4.7.2
5. Max Stirrup Spacing : 11.4.5.1
6. Vs : 11.4.7.9
Deff = 217 mm
Beff = 750 mm
SPu = 265.96 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 6.23 kNm
Ast Rqd = 619 sqmm
Ast (min) = 619 sqmm
Ast Prv = 4 - #20 @ 300
= 1257 sqmm
Distributed Across Total Width
Deff = 201 mm
Leff = 1000 mm
SPu = 265.96 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 8.31 kNm
Ast Rqd = 825 sqmm
Ast (min) = 825 sqmm
Ast Prv = 5 - #20 @ 300
= 1571 sqmm
Deff = 217 mm
Beff = 750 mm
SPu = 265.96 kN/sqm
Vu = SPu X (Loff - d) X B
= 6.58 kN
φVc = 117.31 kN
Vu < φVc
= 201 mm
Critical Analysis Load = 15
Combination
Critical Load Combination = [30] : 1.2 (LOAD 3: DL)
+1.6 (LOAD 4: LL)
Pu = 199.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 265.96 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 201 mm
Leff = 1000 mm
SPu = 265.96 kN/sqm
Vu = SPu X (Boff - d) X L
= 13.03 kN
φVc = 107.05 kN
Vu < φVc
Deff = 209 mm
Leff = 709 mm
Beff = 459 mm
SPu = Average Pressure
= 265.96 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 112.92 kN
φVn = 838.996 kN
φVc = 553.738 kN
No Shear Reinforcement
Vu < φVc
Required
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column Area
= 2900.63 kN
Φ1Pnb > Pu, Hence Safe.
P = 204.20 kN
Mx = 0 kNm
My = 0 kNm
P/A = 218.4 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Maximum Soil Pressure = 218.4 kN/sqm
Allowable Soil Pressure = 1.33x300 kN/sqm
= 399 kN/sqm
Deff = 217 mm
Beff = 850 mm
SPu = 256.16 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 9.8 kNm
Deff = 201 mm
Leff = 1100 mm
SPu = 256.16 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 12.68 kNm
Ast Rqd = 907 sqmm
Ast (min) = 907 sqmm
Ast Prv = 5 - #20 @ 300
= 1571 sqmm
Distributed Across Total Length
Deff = 217 mm
Beff = 850 mm
SPu = 256.16 kN/sqm
Vu = SPu X (Loff - d) X B
= 18.07 kN
φVc = 124.61 kN
Vu < φVc
= 201 mm
Critical Analysis Load = 15
Combination
Critical Load Combination = [30] : 1.2 (LOAD 3: DL)
+1.6 (LOAD 4: LL)
Pu = 239.51 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 256.16 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 201 mm
Leff = 1100 mm
SPu = 256.16 kN/sqm
Vu = SPu X (Boff - d) X L
= 27.90 kN
φVc = 114.69 kN
Vu < φVc
Deff = 209 mm
Leff = 709 mm
Beff = 459 mm
SPu = Average Pressure
= 256.16 kN/sqm
Vu = { N - Pcr(axial)[ (Cx + d) X
(Cy + d)]}
= 156.15 kN
φVn = 838.996 kN
φVc = 553.738 kN
No Shear Reinforcement
Vu < φVc
Required
Load Combinations
(L / C):
1. (LOAD 3: DL) +(LOAD 4: LL)
2. 0.6 (LOAD 3: DL) +0.71 (LOAD 1: EX)
3. 0.6 (LOAD 3: DL) +0.71 (LOAD 2: EZ)
4. 0.6 (LOAD 3: DL) -0.71 (LOAD 1: EX)
5. 0.6 (LOAD 3: DL) -0.71 (LOAD 2: EZ)
6. (LOAD 3: DL) +(LOAD 4: LL) +0.71 (LOAD 1: EX)
7. (LOAD 3: DL) +(LOAD 4: LL) +0.71 (LOAD 2: EZ)
8. (LOAD 3: DL) +(LOAD 4: LL) -0.71 (LOAD 1: EX)
9. (LOAD 3: DL) +(LOAD 4: LL) -0.71 (LOAD 2: EZ)
10. 0.9 (LOAD 3: DL) +(LOAD 1: EX)
Footing No = FC2
Column No = C2
Design Code = ACI 318M - 2011
Depth of founding layer = 1.2 m
Density of Soil = 18 kN/cum
Soil Bearing Capacity = 300 kN/sqm
Permissible SBC Increase for EQ = 33 %
Permissible SBC Increase for Wind = 33 %
Live Load Reduction = 0 %
Design cross section by = Average pressure
Footing Type : Pad
Footing Size (L X B X D) : 1000mm X 750mm X 300mm
Effective Self Weight = 5.63 kN
Footing No = FC8
Column No = C8
Design Code = ACI 318M - 2011
Depth of founding layer = 1.2 m
Density of Soil = 18 kN/cum
Soil Bearing Capacity = 300 kN/sqm
Permissible SBC Increase for EQ = 33 %
Permissible SBC Increase for Wind = 33 %
Live Load Reduction = 0 %
Design cross section by = Average pressure
Footing Type : Pad
Footing Size (L X B X D) : 1100mm X 850mm X 300mm
Effective Self Weight = 7.01 kN