Sensitivity: : <± 30% (50KeV-1.3MeV).


rm response time: ≤ 3 seconds
Weight: 130g (without batteries)
Dimensions: 150mm x 73mm x 31mm
the relative basic error: <± 10%

Mainly used to detect the radiation measurement of rays.

Radiation survey meter radiation monitor Usage

Mainly used to detect the radiation measurement of χ rays, γ rays and β rays.It is widely used in the field of non-destructi
ve testing, nuclear submarines, isotope applications, and hospitals cobalt treatment, nuclear power plants around the resi
dents of the background radiation level monitoring.

Radiation survey meter radiation monitor Features

1, high sensitivity, stable and reliable.

2, large LCD, and the Chinese characters display functions, state display at a glance.

Tenlee Group Piezotronics Inc


Products:distance meter,thermometer,anemometer,noice meter/voice level meter,vibration meter,
hygrothermograph,thickness gauge, meg ohm meter
Email: sales@e-tenlee.com WEB: http://www.t-measurement.com
3, the measurement of radiation dose rate, display dose rate, the cumulative dose and storage accumulated dose, multiple
dose rate alarm threshold to choose the level select measurement time according to the size of the dose rate and accurac
y requirements, generally measuring the time to choose the 02s, measured dose select small background dose 10,20 seco
nds.

4, specialized design background test, testing instruments are in working order, to facilitate the self-inspection and metro
logy department examination.

5, with a cumulative dose of memory function, can be permanently stored data after power is not lost.

6, low power consumption, small size, easy to carry.

7, the instrument is simple, easy to use.

8.Within the measuring range can be fixed or preset alarm thresholds, audible and visual alarm exceeds the threshold or
blocked to prevent excessive dose, to protect the safety of staff

9, the instrument has a storage function of cumulative dose. Memory data after power permanent preservation is not lost,
1,000,000 storage erase.

Radiation survey meter radiation monitor Parameters

applicable radiation occasion γ, χ, β-ray.


the measuring range: dose rate: 0.000usv/h-5msv/h
Cumulative dose: 6 LCD 000.000-999.999msv
Sensitivity: <± 30% (50KeV-1.3MeV).
the relative basic error: <± 10% (137Cs Yuen 662 KeVγ, of radiation 1msv / h).
Alarm response time: ≤ 3 seconds
The threshold dose rate alarm: alarm threshold is 0.5,1.0,2.5,10,30,50 usv / h.
low battery voltage indication: Power marked the full three cell battery power is about 2.8V-3.2V
Power marked the two cell battery power is about 2.5V-2.8V

Power marked the one-cell battery is about 2.1V-2.5V,


The power label-free cell battery below 2.1V in less power status.
work environment requirements: Temperature: -10 - +50 °C
Humidity: 90% (non-condensing)