You are on page 1of 2

Chiller selection Software

Version 4.37 (21-AOUT-2007) - Copyright © 2000-2007, Carrier Corp.

* Project
Date 2/8/2013 12:24:39 PM
Location
Company name
Contact name
CARRIER reference

* Product 30HXY100A-PH3-opt60
Range 30HXC Phase3 Option60 (460-3-60)

* List of the options selected :


Option 33 or 34A (90-10 CU/NI condenseur) - Sea water

Gross capacity 312 kW


Unit absorbed power 75 kW
Compres. Input power 75 kW
C.O.P. 4.14
No of capacity steps 3
Minimum step 40 %
Refrigerant R134a
Expansion valve EXV

* Evaporator
Fluid Water
Leaving T. 7 °C
Delta T. 5 K
Entering T. 12 °C
Flow rate 14.9 L/s
Evaporator pressure drop 73 kPa
Fouling factor 0.04403 m²-K/kW
Max operating pressure 1000 kPa

* Condenser
Fluid Sea water
Entering T. 32 °C
Delta T. 4 K
Leaving T. 36 °C
Flow rate 22.9 L/s
Pressure drop 71 kPa
Fouling factor 0.088 m²-K/kW
Max operating pressure 1000 kPa

T.H.R. 384 kW

* No of compressors 1
Compressor type screw
Compressor motor speed 58.4 r/s
Starter type WYE/DELTA

* Volts/Phases/Hertz 460-3-60
Power Factor (at max power) 0.85
Maximum current drawn 147 A (U nom.)
Maximum starting current 269 A
Voltage limits 414/506 V

* Operating weight 2110.0 kg


Refrigerant charge 83 kg
Length/Width/Height 2794 mm
950 mm
1930 mm

* Acoustic power (dB ref. 1e-12 W) (Full load)


Octave band (Hz)
125 250 500 1K 2K 4K 8K Global
Lw 79 84 83 96 97 91 82 100
Lw(A) 63 75 80 96 98 92 81 101
Global Acoustic power dB(A), according to EUROVENT standard = 101

Average acoustic pressure (dB ref. 2e-5 Pa). Distance 5 m


Octave band (Hz)
125 250 500 1K 2K 4K 8K Global
Lp 52 57 56 69 70 64 55 74
Lp(A) 36.2 48.7 53 69 71 65 54 74
Global pressure level in dB(A) = 74