You are on page 1of 4
© INNER" Flexible Cooling Solutions IN , ny Ce eh) FLEXIBLE INSULATION DUCTS Environment Friendly AHU & HVAC Solutions * Top quality solutions for all your HVAC construction needs. Two distinct cores serve a range of pressure requirements from residential to medium commercial systems, * Flexible duct products for both residential and commercial HVAC applications that provide the most economical solution to your air-handling needs. + Formaldehyde-tree insulation for improved indoor air quality Available as 1) Insulated Flexible Duct 2) Non Insulated Flexible Duct Flexible Duct * Flexible ducting or ‘Flex’ is used to transport hot or cold air from the unit into your home and vice versa through the grills or diffusers, * Itis highly convenient for attaching supply air outlets to rigid duct work. with long zip ties or metal band claps. * Flexible ducts can speed up installation by reducing the number of joints in @ run and eliminating the need for elbows and offsets. * Itis multiple aluminium, polyester laminated ducting with an encapsulated high tensile steel wire helix. * Easy to install over round or oval ducting due to high flexibility * No special tools required for cutting or fixing, * Tested for Fire Resistance. No toxic gas emission in case of fire. * Lower cost due to faster installation, transport and logistics, INSULATED FLEXIBLE DUCT - TECHNICAL DETAILS Te comven emi | teamed aunt mao paps yard cassie wi Peay, ovosbe are Selvin Outer Construction Material The outer vagour barrier is a bi-directional reinforced metalized vapour barrier that will not unravel. Insulation Tikes 25mm, 38 mm and 5m Insulation Density 16 Kgitn? and 24 Kit? Revalue 42, 6and 8 ft*FhiBTU Mac Postive Pressure Rting| Damier 4"to 167-10" WG, Dieter 18° to 207-6" WG ac Negative Pressure | Dametor4t 20°12" WG Mac Velocity 5000 fom Temperature Range 20 a 250F Fire Properties Fire spread index ss than 25, Smoke developed index ess than SO Vigour Transmission Rating | 0.1 USPerm Standard Logit 6A (mat) Dinter rr insted ve IN-LEX ie NON INSULATED FLEXIBLE DUCT - TECHNICAL DETAILS ler Corsucton Maat | Rf crs ord fainted song piyster Fm and encpsuaed witha Ten, caroson resistance (uier Construction Materal | The outer vapour barer is abi-deconal enforced metalzed vapour bari hat wil rot unravel. ‘Max Positive PresoueRating| _Diamater "to 16°-10" WG, Diameter 18to20"-6" WG Max. Negative Pressure Diameter to 20°" WG Max. Velocty 500m “Ternperature Range “20 10250 Fre Properties | Fre spread indox~ess han 25, Smoke developed index — less than 50 ‘Vapour Transmission Ratg | 041 US Perm ‘Standard Length 16.4 (6 meter) Diarrter—ID "1020" Insulated No APPLICATIONS AND BENEFITS * INFLEX® insulated/non insulated flexible ducts are thermally insulated, fully-lined, designed for low-to-medium pressure cooling and heating HVAC systems. It can be used in supply or return sections and is an economical solution for handling misalignment between system components and ducting around obstacles where fabricated & fitted Gl ducts are difficult and costly to use. © tis equally suitable for new jobs or retrofit works and especially useful for system extensions or changing, Conditioned zones, now or in the future. Compliance to NFPA standards allows overcoming the 14” length limitation in conmRsdORRdR: TEFEN BG ERAY RR UUF tin seAReORS 29/06/2022 * tis a highly efficient part of total duct system because the smooth liner, the ample insulation and tough outer vapour barrier provide excellent air flow, thermal insulation and double air seal. * Its widely used in short term installation projects where installation is to be done switly FEATURES INFLEX® strives to satisfy not only contractors, engineers and consultants but also the end users & their Indioor Air Quality (IAQ). * Highly Energy Efficient & Thermally Stable ‘* Minimum Friction Loss * Good Acoustic Performance + Highly Resistant To Microbial Growth * Fire Retarclant Materials Used In Construction *» Light Weight * Easily Expands Over Fittings * Convenient Packaging & Handling * Even Airflow + Extremely Strong * Easy Installation * Corrosion Resistant * Low Maintenance * High Tensile Strength © Durable Finish + Dimensionally Strong * Weather Resistant Minimum Friction Loss ‘= Tear And Puncher Resistant SL 0c. Ref.: IE/C/INFLEX FLEXIBLE DUCTS /01, Rev 1, update on 29/06/2022 AHMEDABAD le-csd@innerengineering.co.in BARODA. le.contacts @innereng.com SURAT jestejas @innerengineering.co.in PUNE le-pune@innerengineering.co.in MUMBAI je mumbai@innereng.com INDORE jemp@innerengineering.co.in BHOPAL le-bhopal@innereng.com RAJASTHAN Jerajastan@innereng.com ANAND. jeanand@innereng.com CHHATTISGARH je.chattisgarh@innereng.com RETAIL SALES leretailsales@innerengineering.co.in KUTCH iesrajkot' Goa le.goa@innereng.com eur aca ee ;nereng.com ooododoooddoaddaddod INNER ENGINEERING PRODUCTS & SYSTEMS PVT LTD INNER’ Samed ae ENGINEERING on, Pn Aci MN Sp gy yy OS re tn DESIGN + COMFORT INSULATION "194 Antigone PtP er nr VE, Cat 1800 572 7963 ie.inquiry@innerengineering.co.in eee eae Stem een nC ere eee a RO kaiser hacia cn alae ae nua Rea ery

You might also like