You are on page 1of 3

LIMITED WARRANTY AND LIMITATION OF LIABILITY

This Fluke product will be free from defects in material and workmanship for one year
from the date of purchase. This warranty does not cover fuses, disposable batteries,
or damage from accident, neglect, misuse, alteration, contamination, or abnormal
conditions of operation or handling. Resellers are not authorized to extend any other

9040 warranty on Fluke’s behalf. To obtain service during the warranty period, contact your
nearest Fluke authorized service center to obtain return authorization information,
Phase Rotation Indicator then send the product to that Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH
AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED.
FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSE-
Users Manual QUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY.
Since some states or countries do not allow the exclusion or limitation of an implied
warranty or of incidental or consequential damages, this limitation of liability may not
apply to you.
Fluke Corporation Fluke Europe B.V.
P.O. Box 9090 P.O. Box 1186
Everett, WA 98206-9090 5602 BD Eindhoven
U.S.A. The Netherlands
PN 2438546 11/99
April 2005, Rev. 3, 11/21
© 2005-2021 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.

Table of Contents

Title Page

Introduction .......................................................................................................... 1
How to Contact Fluke .......................................................................................... 1
Unpacking the 9040 ............................................................................................ 2
Safety Information ............................................................................................... 3
Symbols ............................................................................................................... 5
Elements of the 9040 .......................................................................................... 7
Determine the Rotary Field Direction .................................................................. 8
Maintaining the 9040 ........................................................................................... 9
Replacing the Fuse (9040UK only) ..................................................................... 10
Specifications ...................................................................................................... 11

i ii

9040
Users Manual

Introduction Unpacking the 9040


The Fluke 9040 Phase Rotation Indicator (the 9040 or the Product) is a handheld The 9040 is available in three configurations. Depending on your purchase, the 9040 ships
instrument designed to detect the rotary field of three-phase systems. with these items:
How to Contact Fluke • 9040
Fluke Corporation operates worldwide. For local contact information, go to our website: o 3 self-retaining test probes, 1000 V CAT II
www.fluke.com o 3 alligator clips, 1000 V CAT III/600 V CAT IV
o Users Manual
To register your product, view, print, or download the latest manual or manual supplement, • 9040UK
go to our website. o 3 fused test probes, 1000 V CAT III
Fluke Corporation o 3 alligator clips, 1000 V CAT III/600 V CAT IV
P.O. Box 9090 o Users Manual
Everett, WA 98206-9090 • 9040EUR
+1-425-446-5500 o 3 Slim-Reach™ test probes (black) 1000 V CAT III/600 V CAT IV
o 3 self-retaining test probes, 1000 V CAT II
fluke-info@fluke.com o 3 alligator clips, 1000 V CAT III/600 V CAT IV
o Users Manual
XW Warning
To prevent possible electrical shock, fire, or personal injury, do not exceed
the Measurement Category (CAT) rating of the lowest rated individual
component of a product, probe, or accessory.
If an item is damaged or missing, contact the place of purchase immediately.

1 2
Phase Rotation Indicator 9040
Safety Information Users Manual

Safety Information • Comply with local and national safety codes. Use personal protective
Caution identifies conditions and actions that may damage the 9040. equipment (approved rubber gloves, face protection, and flame-
Warning identifies conditions and actions that pose hazard(s) to the user. resistant clothes) to prevent shock and arc blast injury where
XW Warning hazardous live conductors are exposed.
• Use the product only as specified, or the protection supplied by the
To prevent possible electrical shock, fire, or personal injury:
product can be compromised.
• Read all safety information before you use the Product.
• Do not work alone.
• Carefully read all instructions.
• Do not use test leads if they are damaged. Examine the test leads for
• Use this Product indoors only. damaged insulation or exposed metal. Check test lead continuity.
• Use only current probes, test leads, and adapters supplied with the • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
Product.
• Keep fingers behind the finger guards on the probes.
• Do not use the Product above its rated frequency.
• Measurements can be adversely affected by impedances of additional
• Do not apply more than the rated voltage, between the terminals or operating circuits connected in parallel or by transient currents.
between each terminal and earth ground.
• Verify operation prior to measuring hazardous voltages (voltages above
• Do not keep the Product in operation and unattended at high 30 V ac rms, 42 V ac peak and 60 V dc).
temperatures.
• Do not use the 9040 with any of the parts removed.
• Do not use the product around explosive gas, vapor, or in damp or wet
environments.

3 4

Phase Rotation Indicator 9040


Symbols Users Manual

Symbols Table 1. Symbols (cont.)


The following symbols appear on the 9040 or in this manual. This product complies with the
Table 1. Symbols WEEE Directive marking
requirements. The affixed label
W WARNING. RISK OF DANGER. J Earth ground. indicates that you must not discard
this electrical/electronic product in
Hazardous voltage. Risk of Measurement Category IV is
X T Double Insulated. domestic household waste. Product
electric shock. applicable to test and measuring
Category: With reference to the
Conforms to requirements of
¾ circuits connected at the source
of the building’s low-voltage
~ equipment types in the WEEE
» Consult user documentation. P European Union. Directive Annex I, this product is
MAINS installation.
classed as category 9 "Monitoring
Measurement Category II is and Control Instrumentation"
Measurement Category III is
applicable to test and measuring product. Do not dispose of this
applicable to test and measuring
circuits connected directly to product as unsorted municipal
¼ ½ circuits connected to the distribution
utilization points (socket outlets waste.
part of the building’s low-voltage
and similar points) of the low-
MAINS installation.
voltage MAINS installation.

5 6

Phase Rotation Indicator 9040


Elements of the 9040 Users Manual

Elements of the 9040 Determine the Rotary Field Direction


Indicators, buttons, and jacks are shown in Figure 1. To determine the rotary field direction:
1. Connect the test probes to the end of the test leads.
2. Connect the test probes to the three mains phases.
3. Either the clockwise or counter-clockwise rotary indicator illuminates showing the type
of rotary field direction present.
XW Warning
The rotary indicator lights even if the neutral conductor, N, is connected
instead of L1, L2, or L3. Refer to the back of the 9040 for more information.

Note
The 9040 is powered from the installation under test.

bbx02f.tif
Figure 1. The 9040 Phase Rotation Indicator

7 8
Phase Rotation Indicator 9040
Maintaining the 9040 Users Manual

Maintaining the 9040 Replacing the Fuse (9040UK only)


XWWarning XW Warning
To prevent possible electrical shock, fire, or personal injury, do not operate For safe operation and maintenance of the product:
the Product with covers removed or the case open. Hazardous voltage • Use only specified replacement fuses. See Specifications section.
exposure is possible. • Before you replace the fuse, disconnect the accessory (cable or probe)
W Caution at both ends.
To prevent damage to the 9040: To replace the fuse:
• Do not attempt to repair or service the 9040 unless qualified to do so. 1. Check the fuse using a simple continuity test.
• Make sure that the relevant calibration, performance test, and service 2. Hold the probe in front of the finger guard and unscrew the tip in a counter-
information is being used. clockwise direction.
• Do not use abrasives or solvents. Abrasives or solvents will damage 3. Remove the defective fuse from the fuse holder.
the 9040 case.
The only maintenance the 9040 requires is inspection and cleaning. Periodically wipe the 4. Insert a new fuse in the fuse holder and reassemble the probe.
case with a damp cloth and mild detergent. Clean only with soap and water and remove any
residue afterwards.

9 10

Phase Rotation Indicator 9040


Specifications Users Manual

Specifications Operating Relative Humidity: Electromagnetic Compatibility:


Maximum voltage between any 15 % to 80 % International: IEC 61326-1: Industrial Electromagnetic Environment
Terminal and Earth Ground: 600 V CISPR 11: Group 1, Class A
Altitude: Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio
Power: Supplied by circuit under test. Operating: ≤2000 m frequency energy that is necessary for the internal function of the equipment itself.
Fuse: (9040 UK model only) 0.5 A, Storage: ≤2000 m Class A: Equipment is suitable for use in all establishments other than domestic and
1000 V, 50 kA, 6.3 mm x 32 mm those directly connected to a low-voltage power supply network that supplies buildings
Size: 12.4 cm x 6.1 cm x 2.7 cm used for domestic purposes. There may be potential difficulties in ensuring
Determine Rotary Field Direction:
Weight: 200 g electromagnetic compatibility in other environments due to conducted and radiated
Nominal Voltage: 40 V to 690 V ac disturbances.
(Ume) Safety:
Caution: This equipment is not intended for use in residential environments and may not
Frequency Range (fn): 15 Hz to IEC 61010-1: Pollution Degree 2 provide adequate protection to radio reception in such environments.
400 Hz IEC 61010-2-030: Measurement CAT III Emissions that exceed the levels required by CISPR 11 can occur when the equipment
Current Pickup: 1 mA 600 V/CAT IV 300 V is connected to a test object.
IEC 60925: IP40 (non-operating) The equipment may not meet the immunity requirements of this standard when test
Nominal Test Current (in each phase): leads and/or test probes are connected.
1 mA IEC 61557-7: Phase sequence Korea (KCC):Class A Equipment (Industrial Broadcasting & Communication Equipment)
Temperature: Class A: Equipment meets requirements for industrial electromagnetic wave equipment
Operating: -10 °C to +40 °C and the seller or user should take notice of it. This equipment is intended for use in
business environments and not to be used in homes.
Storage: -40 °C to +60 °C USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause
15.103.