TAP CHANGERS SERIES 086

DT-086 DT_086_2020_REV_00 Pag. 1/16


SUMMARY
TAP CHANGERS TYPE 086

REF. REV. DESCRIPTION CONNECTION CURRENT VOLTAGE N° POS. PAG.


086 01 Introduction 3,4

086-01 00 Code construction 5


086-04-01 02 Three phase tap changer Bridge 150 A / 200 A 24 kV 2-7 6
086-04-02 02 Three phase tap changer Bridge 300 A 24 kV 2-7 7
086-04-03 02 Three phase tap changer Bridge 150 A / 200 A 36 kV 2-7 8
086-04-04 00 Three phase tap changer Bridge 300 A 36 kV 2-7 9

086-02 00 Fixed contacts 150 A / 200 A / 300 A 10

086-120-01 02 Drive handle 2-7 11


086-120-02 02 Assembling sequence diagram 12
086-130-01 03 Drive wheel 2-7 13
086-130-02 03 Assembling sequence diagram 14
086-140-01 01 Drive handle 2-7 15
086-140-02 01 Assembling sequence diagram 16

DT-086 DT_086_2020_REV_00 Pag. 2/16


INTRODUCTION
TAP CHANGERS TYPE 086

MAIN CHARATERISTIC
This is a de-energized three-phase tap changer. It means all switching manoeuvre must be performed after disconnecting transformer
by the electrical net opening the sectionalizing switches, both HV and LV side, so transformer becomes off-circuit.
In the catalogue are performed the standard appliances and devices.
On request is possible to satisfy special requirements as:
- Single-phase tap changer
- Multi-stage tap changers.

DIMENSION
All dimension reported in the following pages are in millimeters (mm).

MODIFICATIONS
In case we need to modify some particulars, in order to improve the quality of our products, C.A.P.T. firma reserve an option to
change without a previous warning. Substantial modification will be surely communicated.

TRANSFORMER OIL
All our tap changers are suitable to work in oil immersed transformers according to standard IEC 60296. In case user need to use
specific oil (silicon, synthetic or vegetal) it is necessary consulted C.A.P.T. technical office who verify the functionality of tap in all the
mechanicals, electrical and chemical characteristics.

INSULATION MATERIAL
The insulating materials used are:
Bakelized paper for the 3 boards and epoxy fiberglass pipe for shaft drive.

GASKET
The standard gaskets supplied by C.A.P.T. for all drives are suitable for use in mineral oil according to IEC 60296 at operating
temperatures between -25°C and +105°C and in air at temperatures between -25°C and +40°C.
On request, depending on the conditions of use C.A.P.T. can provide gaskets suitable for lower temperatures up to -60°C or higher
up to +200°C.

MECHANICAL CHARACTERISTICS
On this rotary tap-changer type 086 fixed contacts are mounted in three insulating boards, parallel to the drive shaft; moving contacts
are installed on the cylindrical drive shaft. The three boards are fixed to the base aluminium support.

CHANGING OVER
A numbering disk is provided to mark each position with precision. For any operation is necessary to lift the blocking pin and turn the
knob to the new position; after that once the knob is facing its new one position, it drops automatically into the respective hole by the
action of a spring. The control knob is marked with the inscription:
“WARNING: DO NOT OPERATE WHILE THE TRANSFORMER IS ENERGIZED”.

POSITION:
Standard from 2 to 7 positions

VOLTAGES
Voltage classes are allowed:

Earth withstand voltage


Voltage class
Industrial frequency 50 Hz Impulse 1/50
kV kV kV
24 50 125
36 70 170

DT-086 DT_086_2020_REV_00 Pag. 3/16


INTRODUCTION
TAP CHANGERS TYPE 086

CURRENT
150 A / 200 A / 300 A.

METALLIC PARTS
The metal components of drive can be supplied on request with GEOMET® treatment.

FIXED CONTACTS
Copper fixed contacts type M8 for 150 A, M10 for 200 A and M12 for 300 A.
On request contacts can be silver-plated or tin-plated.

MOVING CONTACTS
They are made of copper. On request, contacts can be supplied silver plated or tin-plated.

CODES
To identify tap changer type by series and code, proceed like example below reported:
SERIES: 086 CODE: 04.110.215
086- .04 .110 .2 1 5
Family Type Distance between phases Voltage 24 kV Current 150 A Number of positions N°5
L = has to be determined with order
Please also specify type of control knob.

DRYING PROCESS
Different drying treatment can be process by customer: oven, in a vacuum autoclave, vapour-phase or other. In this process is
normally included tap changer too. The maximum temperature suggested by C.A.P.T. for our tap changers is 100°C-120°C for
24-36 hours.

WHEN CONTACT C.A.P.T.


In the following cases please contact C.A.P.T.
- for temperature condition higher/lower then suggest
- for hard environment conditions, with possibility of snow or sand storming, or in potential seismic area.

DT-086 DT_086_2020_REV_00 Pag. 4/16


DETC THREE-PHASE TAP CHANGERS SERIES 086

- CODE CONSTRUCTION

086 - 04 . 110 . 2 1 7 FM

SERIES

TAP CHANGER TYPE

NUMBERS OF DECKS
. Simple three-phase
D Double three-phase
T Triple three-phase

VOLTAGE
2 x 24 kV (BIL= 125 kV)
3 x 36 kV (BIL= 170 kV)

CURRENT
1 x 150 A
2 x 200 A
3 x 300 A
4 x 400 A

NUMBER OF POSITIONS
From 2 to maximum 7 positions.

CONTACTS SURFACE TREATMENT


F Fixed contacts silver plated
M Moving contacts silver plated
FM Fixed and moving contacts silver plated
FS Fixed contacts tin plated
MS Moving contacts tin plated
FMS Fixed and moving contacts tin plated

086-01
Rev. 00 - 07/04/2017

DT-086 Pag. 5/16


DETC ROTARY THREE-PHASE TAP CHANGERS SERIES 086 TYPE 04.110

- De-energized operation
- For oil immersed transformer
- Bridge connection
- 24 kV
- 150 A / 200 A
- From 2 to 7 positions
- Regulation 2,5% per position Dimension in mm

475
139,4 115,6
TANK WALL (A) 18
(B) 42
X

O 25
q 10

X
quote L-130 FIXED CONTACTS 150 A or 200 A
(See catalog page 086-01 Ref. 1 and Ref. 2)

Drive 060-86.120

Thickness 5
or 060-86.130
or 060-86.140 44 110 110 82
20 346 20
386

(A) 44
(B) 76
30
11 (2x) 11 (2x)
O 30
O 24

120
90
=
(A) 30 (A) 38
(B) 62 (B) 62

L ≥195, ≤ 249 (with A)


L ≥ 250 (with B)

130
= =
70

45° (8x)

195
125

15
50

View X
~ 7,3

= =
56

086-04-01
Rev. 02 - 07/06/2017

DT-086 Pag. 6/16


DETC ROTARY THREE-PHASE TAP CHANGERS SERIES 086 TYPE 04.130

- De-energized operation
- For oil immersed transformer
- Bridge connection
- 24 kV
- 300 A
- From 2 to 7 positions
- Regulation 2,5% per position Dimension in mm

575
169,4 145,6
(A) 18
TANK WALL (B) 42

O 25
q 10

quote L-160 X
FIXED CONTACTS 300 A
(See catalog page 086-01 Ref. 3)

Drive 060-86.120

Thickness 5
or 060-86.130
or 060-86.140 44 130 130 76
20 380 20
420

(A) 44
(B) 76
30
11 (2x) 11 (2x)
O 30
O 24

100
70
=
(A) 30 (A) 38
(B) 62 (B) 62

L ≥225, ≤ 279 (with A)


L ≥ 280 (with B)

130
= =
70

45° (8x)

195
125

15
50

View X
~ 7,3

= =
56

086-04-02
Rev. 02 - 07/04/2017

DT-086 Pag. 7/16


DETC ROTARY THREE-PHASE TAP CHANGERS SERIES 086 TYPE 04.130

- De-energized operation
- For oil immersed transformer
- Bridge connection
- 36 kV
- 150 A / 200 A
- From 2 to 7 positions
- Regulation 2,5% per position Dimension in mm

575
169,4 145,6

TANK WALL (A) 18


(B) 42

O 25
q 10

quote L-160 X

FIXED CONTACTS 150 A or 200 A


(See catalog page 086-01 Ref. 1 and Ref. 2)

Drive 060-86.120
or 060-86.130
or 060-86.140

Thickness 5
44 130 130 76
20 380 20
420
(A) 44
(B) 76
30
11 (2x) 11 (2x)
O 30
O 24

100
70
=
(A) 30 (A) 38
(B) 62 (B) 62

L ≥225, ≤ 279 (with A)


L ≥ 280 (with B)

130
= =
70

45° (8x)

245
175

15
90

View X
~ 7,3

= =
56

086-04-03
Rev. 02 - 07/04/2017

DT-086 Pag. 8/16


DETC ROTARY THREE-PHASE TAP CHANGERS SERIES 086 TYPE 04.150

- De-energized operation
- For oil immersed transformer
- Bridge connection
- 36 kV
- 300 A
- From 2 to 7 positions
- Regulation 2,5% per position Dimension in mm

615
169,4 145,6
TANK WALL (A) 18
(B) 42

X
q 10

O 25
quote L-160
X

FIXED CONTACTS 300 A


(See catalog page 086-01 Ref. 3)

Drive 060-86.120
or 060-86.130
or 060-86.140

Thickness 5
44 150 150 76
20 420 20
460
(A) 44
(B) 76
30
11 (2x) 11 (2x)
O 30
O 24

100
70
=
(A) 30 (A) 38
(B) 62 (B) 62

L ≥225, ≤ 279 (with A)


L ≥ 280 (with B)

130
= =
70

45° (8x)

245
175

15
90

View X
~ 7,3

= =
56

086-04-04
Rev. 00 - 07/04/2017

DT-086 Pag. 9/16


COPPER FIXED CONTACTS SERIES 086

- 150 A / 200 A / 300 A

Dimension in mm

38,27

O 10
12 25
65
28

M 8

Threaded contact 150 A, (Ref. 1)

38,27

O 12
25
12
72
35

M 10

Threaded contact 200 A, (Ref. 2)

38,27

O 14
25
12
77
40

M 12
Threaded contact 300 A, (Ref. 3)

086-02
Rev. 00 - 07/04/2017

DT-086 Pag. 10/16


DRIVE TYPE 060-86.120

- Drive handle on tank wall


- From 2 to 7 positions

Dimension in mm

101 O 36
51 50 19,2

60
95
D D

13
A
2

O 50
22

B C
30

44 (with A)
76 (with B)
(A) 30
(B) 62

q 10 O 24
O 38
100

45°

A) Hole ø8,5 for padlock.


B) N°2 gasket OR 3081
C) Steel 11SMnPb37 stuffing box to be welded to the transformer tank wall.
D) N°2 Pin stopper
- Handle is composed by stuffing box, inox-steel index disc and aluminium handle with mechanical block on the position.

086-120-01
Rev. 02 - 07/04/2017

DT-086 Pag. 11/16


DRIVE TYPE 060-86.120

- Assembling sequence diagram


- Drive handle on tank wall
- From 2 to 7 positions

Dimension in mm

TRANSFORMER TANK WALL

+0,250
0
F

O 38 H12
E

C
LIST COMPONENTS IN THE ASSEMBLY ORDER
A) Stuffing box to be welded on the transformer
B tank wall. Made in steel 11SMnPb37

B) N°1 O-ring 3081

A
C) Stainless steel numbering disk
with N°2 pin stopper

D) N° 3 stainless steel washers M4 ISO7089


G E) N° 3 stainless steel screws M4x8 ISO4017

H F) Knob group supplied already assembled

G) N°1 O-ring 3081


I
M
H) Washer for shaft ø20 DIN 988

I) Seeger for shaft ø20 UNI 7435

L) Joint for connection of the square shaft

M) N°1 stainless steel screw M6x35 ISO4762


L
N) N°1 stainless steel washer M6 ISO7089
N O) N°1 metal-block nut M6 DIN 980V
O

086-120-02
Rev. 02 - 07/04/2017

DT-086 Pag. 12/16


DRIVE TYPE 060-86.130

- DRIVE WHEEL ON TANK WALL


- FROM 2 TO 7 POSITIONS

Dimension in mm

58
96
F F
C
16

O 50
22
2

E
D
30

44 (with A)
76 (with B)
(A) 30
(B) 62

q 10 O 24
O 38
O 100
45°

150

C) Hole Ø9,5 for padlock with shackle thickness Ø min: 5, Ø Max: 9.


D) N°2 gasket OR 3081
E) Steel 11SMnPb37 stuffing box to be welded to the transformer tank wall.
F) N°2 Pin stopper
- Handle is composed by stuffing box, inox-steel index disc and aluminium handle with mechanical block on the position.

086-130-01
Rev. 03 - 15/05/2019

DT-086 Pag. 13/16


DRIVE TYPE 060-86.130

- ASSEMBLING SEQUENCE DIAGRAM


- DRIVE WHEEL ON TANK WALL
- FROM 2 TO 7 POSITIONS

Dimension in mm

TRANSFORMER TANK WALL

+0,25
0
O 38 H12
E

C LIST COMPONENTS IN THE ASSEMBLY ORDER


A) Stuffing box to be welded on the transformer
tank wall. Made in steel 11SMnPb37
B
B) N°1 O-ring 3081

C) Stainless steel numbering disk


A with N°2 pin stopper

D) N° 3 stainless steel washers M4 ISO7089


G
E) N° 3 stainless steel screws M4x8 ISO4017

H F) Knob group supplied already assembled

G) N°1 O-ring 3081


I
M H) Washer for shaft ø20 DIN 988

I) Seeger for shaft ø20 UNI 7435


N L) Joint for connection of the square shaft

O L M) N°1 stainless steel screw M6x35 ISO4762

N) N°1 stainless steel washer M6 ISO7089

O) N°1 metal-block nut M6 DIN 980V

086-130-02
Rev. 03 - 13/05/2019

DT-086 Pag. 14/16


DRIVE TYPE 060-86.140

- Drive handle on tank wall


- From 2 to 7 positions

Dimension in mm

O 23,7

36
O 4,25

57
B C
O 50

21
B
30

44 (with A)
76 (with B)
(A) 30
(B) 62

q 10
O 24
O 38
120

B) N°2 gasket OR 3081


C) Steel stuffing box to be welded to the transformer tank wall.

- Handle is composed by stuffing box, aluminium index disc and aluminium handle with mechanical block on the position.

086-140-01
Rev. 01 - 07/04/2017

DT-086 Pag. 15/16


DRIVE TYPE 060-86.140

- Assembling sequence diagram


- Drive handle on tank wall
- From 2 to 7 positions

Dimension in mm

TRANSFORMER TANK WALL

+0,25
F

0
O 38 H12
E

LIST COMPONENTS IN THE ASSEMBLY ORDER


B A) Stuffing box to be welded on the transformer
tank wall. Made in steel 11SMnPb37

B) N°1 O-ring 3081


A
C) Aluminium numbering disk with N°2 pin stopper

D) N° 3 stainless steel washers M4 ISO7089


G E) N° 3 stainless steel screws M4x8 ISO4017

H F) Knob group supplied already assembled

G) N°1 O-ring 3081


I M
H) Washer for shaft ø20 DIN 988

I) Seeger for shaft ø20 UNI 7435

L) Joint for connection of the square shaft

L M) N°1 stainless steel screw M6x35 ISO4762


N
N) N°1 stainless steel washer M6 ISO7089
O O) N°1 metal-block nut M6 DIN 980V

P) Stainless steel lock pin

086-140-02
Rev. 01 - 07/04/2017

DT-086 Pag. 16/16