Circuit Breakers

MOULDED CASE AND


INSULATED CASE
CIRCUIT BREAKERS:

XT2/3 MCCB TMG:


125A – 250A (50/60 Hz)

Standard Features Conformity with International Standards


• IP Rated Circuit Breakers have been designed to comply with the
• Circuit Breakers have been designed to comply international standard IEC 60947-2 as well as these other major
standards:
• Maintenance-free operation
• Exceptional characteristics under short-circuit
• Adjustable trip settings
• Clear indication of breaker status with the international
standard IEC 60947-2 costs

Optional Features
• Shunt trip
• Auxiliary contacts
• Load side extension bars

Circuit Breaker Table:

No of Poles Current (A) Frame Operation Trip Units Auxillary options


3, 4 125 Amp XT2N MO TMD / TMF 400VAC / 250V AC/DC
Shunt Trip 24VDC
3, 4 160 Amp XT2N MO TMD / TMF 400VAC / 250V AC/DC
Shunt Trip 24VDC
3, 4 200 Amp XT3N MO TMD / TMF 400VAC / 250V AC/DC
Shunt Trip 24VDC
3, 4 250 Amp XT3N MO TMD / TMF 400VAC / 250V AC/DC
Shunt Trip 24VDC

LEHE1764-01 1/4
Circuit Breakers
Circuit Breaker Table

Model XT2N XT3

Number of Poles 3, 4 3, 4

Tripping Characteristics Thermomagnetic Thermomagnetic

Rated Current (Amps) 125-160 A 200-250 A

Voltage Rating (VAC) 690 690

Rated Insulation Voltage 1000 V 800 V

Rated Impulse Withstand Voltage 8 kV 8 kV

220/230/240 V 65 65

380/415/440 V 36 36
IEC 60947-2 Icu
500 V 30 30

525 V 20 20

690 V 10 10

220/230/240 V 65 65

380/415/440 V 36 36
(50/60Hz) - kA RMS Ics 500 V 30 30

525 V 20 20

690 V 10 10

No. Operations 25000 25000


Mechanical Life
No. Hourly Operations 240 240

No. Operations 8000 8000


Electrical Life @ 415V
No. Hourly Operations 120 120

LEHE1764-01 2/4
Circuit Breakers
Trip curves with thermomagnetic trip unit

XT1 160 TMD In=16...63A XT1 160 TMD In=80...160A

t [s] t [s]
104 104

103 103

102 102

10 10

1 1

10-1 In=16A I3=450A 10-1


In=20A I3=450A
In=25A I3=450A I3=10xIn
I n=32A I3=450A
In=40A I3=450A
In=50-63A I3=10xIn

10-2 10-2
10-1 1 10 102 10-1 1 10 102
xI1 xI1

XT2 160 TMA In=1.6...160A XT3 250 TMD In=63...250A

t [s] t [s]
104 104

103 103

102 102

10 10

In=1.6...12.5 A

In=16...25 A
1 1
In=63...160 A

I3=40 A I3=10xIn
10-1 10-1
In=50 A

10-2 10-2
10-1 1 10 102 10-1 1 10 102
xI1 xI1

LEHE1764-01 3/4
Circuit Breakers
Trip curves with thermomagnetic trip unit
Trip curves for generator protection

XT2 160 TMG In=16...160A XT3 250 TMG In=63...250A

t [s] t [s]
104 104

103 103

102 102

10 10

1 1

In=63...160A In=125...250A
In=50A In=100A
In=32-40A In=80A
In=25A In=63A
10-1 In=20A 10-1
In=16A

10-2 10-2
10-1 1 10 102 10-1 1 10 102
xI1 xI1

LEHE1764-01 (04/19)

www.Cat.com/electricpower
© 2019 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, "Caterpillar Yellow", the "Power Edge" and Cat “Modern Hex” trade dress as well
as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. 4/4
Note : The Information on this Document comes from a Third Party Supplier and is not a Caterpillar Material