INSTALLATION
RS232
The following steps describe how to properly install the cables for an RS232 StratosH application. The scanner/Diva
scale must then be configured to match the host’s RS232 parameters. Cable installation alone does not guarantee
that the StratosH will communicate properly with the host system.
2. Plug the 10-pin RJ45 end of the RS232 interface cable (MLPN 57-57000x-N-3) into the 10-pin socket labeled
Scanner RS232 to Host, on the bottom of the StratosH.
3. Connect the other end of the RS232 cable to the proper communication port on the host device.
4. Plug the dual interface cable (MLPN 57-57000x-N-3) into the 10-pin socket labeled, Scale RS232 to Host, on
the bottom of the StratosH.
5. Connect the other end of the dual interface cable (MLPN 57-57000x-N-3) to the appropriate communication port
on the host’s scale device.
6. Plug the optional remote display cable** into the 10-pin socket labeled, Scale to Display, on the bottom of the
StratosH.
7. Plug the dual interface cable (MLPN 57-57000x-N-3) into the 10-pin socket labeled, Scale RS232 to Host, on the
bottom of the StratosH.
8. Connect the other end of the dual interface cable (MLPN 57-57000x-N-3) to the appropriate communication port
on the host’s scale device.
Plug the optional remote display cable** into the 10-pin socket labeled, Scale to Display, on the bottom of the
StratosH.
9. Connect AC power to the transformer. If the AC outlet is equipped with an on/off switch, turn the power on.
³ 9 9 9 9 9 8
³ 9 9 9 9 5 3
³ 9 9 6 0 4 5 This will “save” the changes in the scale memory. The scale will reset and begin normal
operation.
³ 9 9 6 0 1 5
³ 9 9 6 0 4 5 This will “save” the changes in the scale memory. The scale will reset and begin normal
operation.
***The scanner & scale are now configured for Dual Cable Serial Data. ***
Testing
Open MetroSet
Select MetroSet2 configuration & Utility Software from the drop down menu.