Why Are Transformers Rated in kVA, and not in kW?


Digital Electronics Electron Electronics & Electrical

Transformers are always rated in kVA instead of kW. Let's see why it is so.

Reason 1
The first reason is the power loss in the transformer. As, the copper loss or I2R loss
depends on the current and the iron or core loss depends upon the voltage of the
transformer. Thus, the total losses in a transformer depend upon volt-ampere (VA)
only and not on the power factor of the load. That is why the transformer rating is
given in kVA and not in kW.

Reason 2
At the time of designing a transformer, the manufacturer does not know which kind
of load (inductive or capacitive or resistive) will be connected in future. Also, the
power factor depends upon the load. In actual practice, the pure inductive (lagging)
and pure capacitive (leading) loads do not exist, i.e., every load has some resistance
even it is inductive or capacitive. Hence, the practical loads draw both active and
reactive powers from the supply.

For example, an induction motor has windings which are inductive and also possess
some resistance. Thus, it draws both active power (kW) and reactive power (kVAR) so
that the total power drawn by the motor is the phasor sum of kW and kVAR, which is
equal to kVA. Also, the current drawn by the load depends upon the power factor of it,
which is not determinant to the manufacturer at the time of designing. Due to this
reason a transformer is always rated in kVA so that it can be used for any kind load
(lagging or leading).

Reason 3
The temperature rise of a transformer is directly proportional to the apparent power
(kVA) which flows through it. This is also a principle factor behind that the rating of
the transformer is given in kVA and not in kW.

Important – In actual practice, those electrical devices which act as the source (such
as alternator, transformer) always rated in kVA to make their operation independent
of the load power factor while the electrical devices which act as the load (e.g.,
motors) always rated in kW and draw the current from the source according to their
power factor.

Manish Kumar Saini


Published on 16-Aug-2021 12:45:18

Related Questions & Answers


Why are Hindu saints buried and not cremated?
Why Don't Transformers Work on DC Supply?
Harmonics in Three Phase Transformers
Different Types of Transformers and Their Applications
Parallel Operation of Transformers – Reasons and Conditions
Why are the keys on the keyboard not arranged in alphabetical order?
Why are people interested in rumors and gossips?
Why are Indian women cricket matches not getting the broadcasters?
Six-Phase Star Connection and Diametrical Connection of Transformers
Why are petrol prices not decreased in India when international prices of crude oil
are low?
Why and how are Python functions hashable?
Why is Greenland called as island and not a continent?
Why do our eyelashes and eyebrows does not grow continuously?
Why are NULL pointers defined differently in C and C++?
Why should we not use ++, -- operators in JavaScript?

Previous Page Next Page

Advertisements

About us
Terms of use
Cookies Policy
FAQ's
Helping
Contact

© Copyright 2021. All Rights Reserved.

We make use of cookies to improve our user experience. By using this website, you agree with our
Cookies Policy.

Agree

Learn more

You might also like