You are on page 1of 20

TRANSLINE CABLE

Table Of Contents

III.AirCell® Transline Cables Pages

A) Overview and Product Description 10-13

B) Cable Selection Guide 14-15

C) Specification Sheets 16-23

D) Accessory Selection Information 24-28

9 8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
TRANSLINE CABLE
Overview

Trilogy’s AirCell® cables embody innovative, waterproof air-dielectric design, consistent manufacturing, and quality
assurance techniques in accordance with ISO-9001 procedures. The result is a coaxial cable with superior
electrical and mechanical performance that completely eliminates water migration.

Trilogy’s AirCell® Transline cable is designed for base station applications and is field proven in cellular, PCS,
ESMR, paging, broadcast, and microwave applications. AirCell® Transline cables are available with impedances of 50
Ohms in 1/2", 5/8", 7/8", 1-1/4", and 1-5/8" sizes and with impedances of 75 Ohms in 1/2", 5/8", and 7/8" sizes.

To accompany our cables,Trilogy offers a complete line of connectors, accessories, and cable assemblies for all
your wireless application needs.

AirCell® Transline cable is designed for the following applications:

PCS, Cellular, and Paging


Trilogy’s cables and connectors are ideally suited to the high performance requirements of cellular and PCS
applications. Transline cable’s excellent insertion loss,VSWR, and intermodulation characteristics enhance both
digital and analog systems. Water migration problems are non-existent because of the unique AirCell® design.
Trilogy’s high performance connectors are easily attached to form a solid watertight assembly that will provide
trouble free communications for the life of your system.

Broadcast
Having the easiest installation in the industry makes AirCell® Transline cable the best choice for radio and television
broadcast antenna feeders and for AM, FM, shortwave,VHF, and UHF frequencies.

Microwave
Trilogy’s AirCell® Transline cable is perfect for all private and PTF microwave applications. Transline cable’s superior
VSWR performance has been specifically tested for microwave applications. The cable’s strong, rugged design as
well as flexibility makes it easy to install in any climate, and its weatherproof properties result in a life
expectancy of over 15 years.

Enhanced Specialized Mobile Radio (ESMR)


The low attenuation and high shielding effectiveness of AirCell® Transline make it an ideal replacement for braided
cable. The low insertion loss of Trilogy’s AirCell® Transline cables typically provides double the coverage area for the
same transmit power, or it can provide coverage to the same area and use lower transmit power.

8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m 10
TRANSLINE CABLE
Overview

Level of Fire Retardancy


The standard Transline cable construction uses a weather-resistant, black polyethylene jacket suitable for indoor,
outdoor, or underground installations. For additional requirements regarding flame retardancy, AirCell® Transline
cables are available with a non-halogenated, flame retardant jacket, which meets the most stringent fire
retardancy requirements of UL, NEC, IEC, MSHA, and NES as shown below.

AirCell® Transline Fire Retardancy Ratings* USA Europe

Vertical Wire Flame Test UL VW1/CMX


Vertical Tray Flame Test UL 1581/CATV
Riser Cable Test UL 1666/CMR
Vertical Single Cable Test IEC 332-1
Halogen Acid Gas Test IEC 754-1
Acid Gas Test IEC 754-2
Approved for use in Underground MSHA 30 CFR
Mines as Signal Cable

*Ratings based on cable diameters and construction

Benefits of AirCell® Transline Cable


Our AirCell® Transline cable’s superior air-dielectric design and our manufacturing experience guarantee a
technically superior product with the following advantages:

Low VSWR
The unique design and precise manufacturing processes of AirCell® Transline cables offer the lowest VSWR
performance in the industry.

Low Attenuation
The patented air-dielectric design and 91% velocity of propagation of AirCell® Transline cables provide the
lowest attenuation available, which results in highly efficient signal transfer in your RF system.

High Power Capability


Due to their low attenuation and excellent thermal conductivity, AirCell® Transline cables offer a high
average power handling capability that exceeds the requirements of PCS, cellular, paging, and ESMR
applications.
Weatherproof for Stability in Outdoor Applications
AirCell® Transline cables are perfect for outdoor applications because they do not allow water migration. The
hermetically sealed, fully bonded design of AirCell® Transline cable prohibits water migration through the
cable. Trilogy guarantees this with the industry’s best warranty–15 years including cable and installation.

11 8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
TRANSLINE CABLE
Overview

AirCell® Transline cables are also protected with a rugged, black polyethylene jacket that provides abrasion
resistance and complete environmental protection.

Superior Durability
AirCell® Transline cables have superior longitudinal strength, crush resistance, and flexibility. This rugged construction
ensures that installations are trouble free and that in-service life and system reliability is maximized.

Total Shielding
The solid outer conductor of AirCell® Transline cable creates a continuous RFI/EMI shield that eliminates system
interference.

Minimized Intermodulation Generation


AirCell® Transline cable’s solid inner and outer conductors and its silver-plated connector junction virtually
eliminate intermodulation interference in applications such as PCS, cellular, and paging.

Flexibility
The totally bonded design of AirCell® Transline cable offers excellent flexibility, making them suitable for tower
and base station installations where multiple bends are needed. AirCell® Transline cables can be easily routed
because of their durability and lower bending moments.

Ease of Connectorization
Trilogy’s AirCell® Transline cables have the fastest field connectorization time in the industry. By using the AirCell®
all-in-one prep tool (see p.68 ), installing connectors on AirCell® Transline cables can be accomplished in one
easy step that requires less than two minutes. In addition, our connectorization does not require soldering or
removal of the center conductor foam. Together Trilogy’s cable and connectors are an unbeatable match that
optimize entire system performance.

Complete Product Line


AirCell® Transline cables are complemented by our compatible, high-quality connectors, hangers, grounding
systems, and other installation accessories to form a complete RF transmission line system. This means that
Trilogy Communications meets all of your transmission line needs. At Trilogy, all of our cable components are
engineered to work together. Our quality products are delivered fast and on time –saving you time and money.

8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m 12
TRANSLINE CABLE
Product Description

Transline Premium Performance Cable

Center Conductor
The center conductor of the cable consists of either a pure copper
tube or a copper-clad electrical grade aluminum wire with 10%
copper by volume which conforms to ASTM B-566, class 10A. This
lightweight conductor provides both high quality and strength.

Conductor Adhesive
The center conductor is coated with a proprietary adhesive to secure
the dielectric discs to the center conductor. This adhesive ensures
that the discs are bonded to the center conductor, which prevents
moisture migration and center conductor pull-out. In addition, this
material can easily be removed to facilitate quick connector installation.

Dielectric Discs
The dielectric discs are injection molded from virgin polyethylene
(ASTM D-1248). These discs are regularly spaced to provide structural
integrity while minimizing attenuation.

Dielectric Tube
The dielectric tube is extruded over the dielectric discs using a
virgin polyethylene (ASTM D-1248). The tube and disc materials
are bonded together, forming hermetically sealed chambers that
provide a barrier to water penetration. Since this type of dielectric
structure contains a high percentage of air, the cable attenuation
is the lowest available.

Dielectric Adhesive
The dielectric tube adhesive is composed of a proprietary polymer
that is co-extruded over the dielectric tube. The adhesive bonds
the inner dielectric tube to the aluminum outer conductor, resulting
in a strong, durable composite structure.

Aluminum Outer Conductor


The outer conductor is a continuously formed and welded premium
grade aluminum tube. In-process monitoring assures weld integrity,
maintains proper aluminum thickness, and corrects physical dimen-
sions. This conductor provides unsurpassed shielding, high crush
strength, and no intermodulation generation.

Jacket
A UV-stabilized, black, polyethylene jacket is standard (ASTM D-1248).
This jacket provides the strength and durability to meet the most
demanding conditions. Fire Retardancy: optional fire retardant jackets
are also available to meet more stringent requirements.

13 8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
AirCell
® TRANSLINE CABLE

Cable Specifications Summary


50 Ohm Transline, 1/2”, 7/8”, 1-1/4" and 1-5/8” (5/8”-size cable is also available upon request)
Cable Size ½” 7/8” 1-1/4” 1-5/8”
Jacketing Product Code Product Code Product Code Product Code
Black Polyethylene Jacket AT012J50 AT078J50 AT114J50 AT158J50
Low-Smoke, Non-Halogenated, Fire
AT012FX50 AT078FX50 AT114FX50 AT158FX50
Retardant Jacket, IEC332-1
Low-Smoke, Non-Halogenated, Fire
AT012F50 - - -
Retardant Jacket, IEC332-1, MSHA
Low-Smoke, Non-Halogenated, Fire
Retardant Jacket, IEC332-1, IEC332-3C, AT012R50 AT078R50 AT114R50 AT158R50
UL-1666, CMR
Characteristics
Dia. Over Dielectric, in (mm) 0.470 (11.94) 0.968 (24.58) 1.480 (37.59) 1.871 (47.52)
Dia. Over Outer Conductor, in (mm) 0.510 (12.95) 1.012 (25.70) 1.524 (38.71) 1.888 (47.96)
Max. Dia. Over Jacket, in (mm) 0.642 (16.30) 1.142 (29.01) 1.654 (42.01) 2.035 (51.69)
Cable Weight, lb/ft (kg/km) 0.12 (0.18) 0.29 (0.43) 0.53 (0.789) 0.70 (1.037)
Min. Bend. Radius, in (mm) – Single 2 (50.8) 5 (127) 6 (152.4) 8 (203)
Min. Bend. Radius, in (mm) – Multiple 6 (152) 10 (254) 15 (381) 20 (508)
Tensile Strength, lb (kg) 465 (211) 734 (333.6) 1124 (511) 1500 (682)
Flat Plate Crush, lb/in (kg/mm) 62 (1.11) 132 (2.36) 122 (2.18) 150 (2.68)
Impedance, Ohms 50 50 50 50
Velocity of Propagation 91% 91% 91% 91%
Maximum Frequency, GHz 11 5 3.4 3
Attenuation, dB/100 ft (db/100 m)
100 MHz 0.68 (2.23) 0.33 (1.08) 0.24 (0.79) 0.18 (0.61)
150 MHz 0.84 (2.76) 0.40 (1.31) 0.29 (0.95) 0.23 (0.76)
450 MHz 1.49 (4.89) 0.73 (2.40) 0.54 (1.77) 0.42 (1.39)
894 MHz 2.15 (7.05) 1.08 (3.54) 0.81 (2.66) 0.62 (2.04)
960 MHz 2.25 (7.38) 1.12 (3.67) 0.85 (2.79) 0.64 (2.13)
1800 MHz 3.16 (10.37) 1.61 (5.28) 1.25 (4.10) 0.96 (3.02)
2000 MHz 3.38 (11.09) 1.72 (5.64) 1.33 (4.36) 1.01 (3.34)
2300 MHz 3.61 (11.80) 1.87 (6.14) 1.45 (4.76) 1.10 (3.61)
3000 MHz 4.29 (14.07) 2.20 (7.22) 1.84 (6.04) 1.36 (4.46)
Average Power Rating, kW
100 MHz 2.24 6.31 14.78 20.70
150 MHz 1.83 5.13 12.24 16.55
450 MHz 1.05 2.93 6.57 8.85
894 MHz 0.74 2.06 4.38 5.93
960 MHz 0.71 1.98 4.17 5.56
1800 MHz 0.52 1.55 2.87 3.76
2000 MHz 0.49 1.35 2.67 3.51
2300 MHz 0.46 1.25 2.44 3.20
3000 MHz 0.40 1.09 1.93 2.44

800-TRILOGY (874–5649) • 601-932-4461 • www.trilogycoax.com


8/08
AirCell
TRANSLINE CABLES
®
Cable Specifications Summary
75 Ohm Transline
Cable Size 1/2" 5/8” 7/8”

Jacketing Product Code Product Code Product Code


Black Polyethylene Jacket AT012J75 AT058J75 AT078J75
Low-Smoke, Non-Halogenated,
AT012FX75 AT058FX75 AT078FX75
Fire Retardant Jacket, IEC332-1
Low-Smoke, Non-Halogenated, Fire
AT012F75 - -
Retardant Jacket, IEC332-1, MSHA
Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1, AT012R75 AT058R75 AT078R75
IEC332-3C, UL-1666, CMR

Characteristics
Dia. Over Dielectric, in (mm) 0.470 (11.94) 0.712 (18.08) 0.961 (24.41)
Dia. Over Outer Conductor, in (mm) 0.510 (12.95) 0.760 (19.30) 1.015 (25.78)
Max. Dia. Over Jacket, in (mm) 0.652 (16.56) 0.892 (22.65) 1.147 (29.13)
Weight, lb/ft (kg/m) 0.10 (0.15) 0.20 (0.29) 0.35 (0.47)
Min. Bend. Rad. in (mm) – Single 2 (50.8) 3 (76.2) 8 (203)
Min. Bend. Rad. In (mm) – Multiple 6 (152) 8 (203) 10 (254)
Tensile Strength, lb (kg) 465 (211) 500 (227) 830 (377)
Flat Plate Crush, lb/in (kg/mm) 62 (1.11) 140 (2.50) 132 (2.36)
Impedance, Ohms 75 75 75
Velocity of Propagation 93% 93% 93%
Maximum Frequency, GHz 11 8 6

Attenuation, dB/100 ft (dB/100 m)


100 MHz 0.65 (2.13) 0.46 (1.51) 0.32 (1.05)
150 MHz 0.77 (2.53) 0.56 (1.84) 0.40 (1.31)
450 MHz 1.40 (4.59) 0.97 (3.18) 0.74 (2.43)
894 MHz 2.02 (6.63) 1.37 (4.49) 1.08 (3.54)
960 MHz 2.10 (6.89) 1.44 (4.72) 1.13 (3.71)
1800 MHz 2.86 (9.38) 1.95 (6.40) 1.62 (5.31)
2000 MHz 3.03 (9.94) 2.07 (6.79) 1.74 (5.71)
2300 MHz 3.26 (10.70) 2.29 (7.51) 1.89 (6.20)
3000 MHz 3.72 (12.2) 2.62 (8.59) 2.16 (7.09)
Average Power Rating, kW
100 MHz 1.73 3.13 5.32
150 MHz 1.45 2.68 4.51
450 MHz 0.80 1.48 2.30
894 MHz 0.56 1.05 1.58
960 MHz 0.53 1.00 1.51
1800 MHz 0.39 0.74 1.06
2000 MHz 0.37 0.70 0.98
2300 MHz 0.34 0.63 0.90
3000 MHz 0.30 0.55 0.79
800-TRILOGY (874–5649) • 601-932-4461 • www.trilogycoax.com
7/08
AirCell TRANSLINE CABLE
®

Cable Specifications
50 Ohm Transline Cable 1/2˝
Description Product Number
Attenuation and Average Power
Standard Cable Frequency Attenuation Avg. Pwr.
½”, Black Polyethylene Jacket AT012J50 MHz dB/100 ft dB/100m kW
Fire Retardant Jacket 30 0.37 1.21 4.11
½”, Low-Smoke, Non-Halogenated, 50 0.48 1.57 3.18
AT012FX50
Fire Retardant Jacket, IEC332-1 88 0.63 2.06 2.39
½”, Low-Smoke, Non-Halogenated, 100 0.68 2.23 2.24
Fire Retardant Jacket, IEC332-1, MSHA
AT012F50
108 0.69 2.26 2.16
Riser Rated Cable
150 0.84 2.76 1.83
½”, Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, UL-1666, CMR, AT012R50 174 0.88 2.88 1.70
IEC332-1, IEC332-3C 200 0.98 3.22 1.58
Physical Dimensions 300 1.21 3.97 1.29
Center Dia., in (mm) 0.188 (4.78) 400 1.41 4.63 1.11
Dia. Over Dielectric, in (mm) 0.470 (11.94) 450 1.49 4.89 1.05
Dia. Over Outer Conductor, in (mm) 0.510 (12.95) 500 1.57 5.15 1.00
Max. Dia. Over Jacket, in (mm) 0.642 (16.30) 512 1.59 5.22 0.98
Center Conductor Copper-Clad Aluminum 600 1.73 5.68 0.91
Outer Conductor Solid Aluminum 700 1.88 6.17 0.84
800 2.03 6.66 0.78
Electrical Characteristics 824 2.05 6.73 0.77
Maximum Frequency, GHz 11 894 2.15 7.05 0.74
Peak Power Rating, KW 32 960 2.25 7.38 0.71
DC Res, Ohms/1000 ft (1000m) 1000 2.29 7.51 0.70
Center 0.46 (1.51) 1250 2.57 8.43 0.62
Outer 0.45 (1.48) 1500 2.85 9.35 0.57
DC Breakdown, kV 3.2 1800 3.16 10.37 0.52
Capacitance, pF/ft (m) 22.3 (73.16) 1900 3.27 10.73 0.50
Inductance, mH/ft (m) 0.056 (0.184) 2000 3.38 11.09 0.49
Jacket Spark, kV RMS 8 2300 3.61 11.80 0.46
Typical VSWR 1.3 3000 4.29 14.07 0.40
Impedance, Ohms 50
Velocity of Propagation 91%
Standard conditions:
Mechanical Characteristics o
For attenuation, VSWR 1.0, ambient temperature 20 C
o
Min. Bend. Rad., in (mm) – Single 2 (50.8) (68 F)
Min. Bend. Rad., in (mm) – Multiple 6 (152) For average power, VSWR 1.0, ambient temperature
o o o o
40 C (104 F), inner conductor temperature 100 C (212 F),
Cable Weight, lb/ft (kg/m) 0.12 (0.18) no solar loading
Bending Moment, ft.lb (N.m) 7.5 (10.2)
Tensile Strength, lb (kg) 465 (211)
Flat Plate Crush, lb/in (kg/mm) 62 (1.11)
Number of Bends 20
Temperature, oF (oC)
Recommended Install -40 to 170 (-40 to 77)
NEW
Recommended Storage -94 to 170 (-70 to 77)
Operating -40 to 170 (-40 to 77)

800-TRILOGY (874–5649) • 601-932-4461 • www.trilogycoax.com 8/08


AirCell TRANSLINE CABLE
®

Cable Specifications
50 Ohm Transline Cable 5/8˝
Description Product Number
Attenuation and Average Power
Standard Cable Frequency Attenuation Avg. Pwr.
5/8”, Black Polyethylene Jacket AT058J50 MHz dB/100 ft dB/100m kW
Fire Retardant Jacket 30 0.28 0.92 8.36
5/8”, Low-Smoke, Non-Halogenated, 50 0.36 1.17 6.46
AT058FX50 88 0.46 1.50 4.86
Fire Retardant Jacket, IEC332-1
Riser Rated Cable 100 0.50 1.64 4.56
5/8”, Low-Smoke, Non-Halogenated, 108 0.52 1.70 4.38
Fire Retardant Jacket, UL-1666, CMR, AT058R50 150 0.62 2.03 3.71
IEC332-1, IEC332-3C 174 0.66 2.16 3.45
Physical Dimensions 200 0.72 2.36 3.21
Center Dia., in (mm) 0.283 (7.9) 300 0.88 2.89 2.61
Dia. Over Dielectric, in (mm) 0.712 (18.08) 400 1.01 3.31 2.26
Dia. Over Outer Conductor, in (mm) 0.760 (19.30) 450 1.08 3.54 2.13
Max. Dia. Over Jacket, in (mm) 0.892 (22.65) 500 1.14 3.74 2.02
Center Conductor Solid Copper Tube 512 1.15 3.77 1.99
Outer Conductor Solid Aluminum Tube 600 1.23 4.04 1.84
700 1.35 4.43 1.70
Electrical Characteristics 800 1.45 4.76 1.58
Maximum Frequency, GHz 7 824 1.48 4.86 1.56
Peak Power Rating, KW 65 894 1.54 5.05 1.50
DC Res, Ohms/1000 ft (1000m) 960 1.60 5.25 1.44
Center 0.36 (1.18) 1000 1.64 5.38 1.41
Outer 0.25 (0.82) 1250 1.86 6.10 1.26
DC Breakdown, kV 5 1500 2.07 6.79 1.15
1800 2.31 7.58 1.04
Capacitance, pF/ft (m) 22.3 (73.16)
1900 2.39 7.84 1.01
Inductance, mH/ft (m) 0.056 (0.184)
2000 2.47 8.10 0.99
Jacket Spark, kV RMS 8
2300 2.72 8.92 0.92
Typical VSWR < 1.1
3000 3.24 10.63 0.80
Impedance, Ohms 50
Velocity of Propagation 91%
Standard conditions:
Mechanical Characteristics o
For attenuation, VSWR 1.0, ambient temperature 20 C
o
Min. Bend. Rad., in (mm) – Single 3 (76.2) (68 F)
Min. Bend. Rad., in (mm) – Multiple 8 (203) For average power, VSWR 1.0, ambient temperature
o o o o
40 C (104 F), inner conductor temperature 100 C (212 F),
Cable Weight, lb/ft (kg/m) 0.25 (0.38) no solar loading
Bending Moment, ft.lb (N.m) 21 (28.5)
Tensile Strength, lb (kg) 920 (417)
Flat Plate Crush, lb/in (kg/mm) 140 (2.50)
Number of Bends 20
Temperature, oF (oC)
Recommended Install -40 to 170 (-40 to 77) NEW
Recommended Storage -94 to 170 (-70 to 77)
Operating -40 to 170 (-40 to 77)

800-TRILOGY (874–5649) • 601-932-4461 • www.trilogycoax.com 8/08


AirCell TRANSLINE CABLE
®

Cable Specifications
50 Ohm Transline Cable 7/8˝
Description Product Number
Attenuation and Average Power
Standard Cable Frequency Attenuation Avg. Pwr.
7/8”, Black Polyethylene Jacket AT078J50 MHz dB/100 ft dB/100m kW
Fire Retardant Jacket 30 0.17 0.56 11.60
7/8”, Low-Smoke, Non-Halogenated, 50 0.23 0.75 8.95
AT078FX50 88 0.31 1.02 6.73
Fire Retardant Jacket, IEC332-1
Riser Rated Cable 100 0.33 1.08 6.31
7/8”, Low-Smoke, Non-Halogenated, 108 0.34 1.12 6.07
Fire Retardant Jacket, UL-1666, CMR, AT078R50 150 0.40 1.31 5.13
IEC332-1, IEC332-3C 174 0.44 1.44 4.76
Physical Dimensions 200 0.47 1.54 4.44
Center Dia., in (mm) 0.383 (9.73) 300 0.59 1.94 3.61
Dia. Over Dielectric, in (mm) 0.968 (24.58) 400 0.69 2.26 3.11
Dia. Over Outer Conductor, in (mm) 1.012 (25.70) 450 0.73 2.40 2.93
Max. Dia. Over Jacket, in (mm) 1.142 (29.01) 500 0.78 2.56 2.78
Center Conductor Solid Copper Tube 512 0.79 2.59 2.74
Outer Conductor Solid Aluminum Tube 600 0.86 2.82 2.53
700 0.94 3.08 2.33
Electrical Characteristics 800 1.01 3.31 2.18
Maximum Frequency, GHz 5 824 1.03 3.38 2.15
Peak Power Rating, KW 90 894 1.08 3.54 2.06
DC Res, Ohms/1000 ft (1000m) 960 1.12 3.67 1.98
Center 0.47 (1.54) 1000 1.15 3.77 1.94
Outer 0.20 (0.64) 1250 1.30 4.27 1.73
DC Breakdown, kV 6.7 1500 1.45 4.76 1.57
1800 1.61 5.28 1.55
Capacitance, pF/ft (m) 22.3 (73.16)
1900 1.67 5.48 1.53
Inductance, mH/ft (m) 0.056 (0.184)
2000 1.72 5.64 1.35
Jacket Spark, kV RMS 8
2300 1.87 6.14 1.25
Typical VSWR < 1.1
3000 2.20 7.22 1.09
Impedance, Ohms 50
Velocity of Propagation 91%
Standard conditions:
Mechanical Characteristics o
For attenuation, VSWR 1.0, ambient temperature 20 C
o
Min. Bend. Rad., in (mm) – Single 5 (127) (68 F)
Min. Bend. Rad., in (mm) – Multiple 10 (254) For average power, VSWR 1.0, ambient temperature
o o o o
40 C (104 F), inner conductor temperature 100 C (212 F),
Cable Weight, lb/ft (kg/m) 0.29 (0.43) no solar loading
Bending Moment, ft.lb (N.m) 26 (35.1)
Tensile Strength, lb (kg) 734 (333.6)
Flat Plate Crush, lb/in (kg/mm) 132 (2.36)
Number of Bends 20
Temperature, oF (oC)
Recommended Install -40 to 170 (-40 to 77) NEW
Recommended Storage -94 to 170 (-70 to 77)
Operating -40 to 170 (-40 to 77)

800-TRILOGY (874–5649) • 601-932-4461 • www.trilogycoax.com 8/08


AirCell TRANSLINE CABLE
®

Cable Specifications
50 Ohm Transline Cable 1-1/4˝
Description Product Number
Attenuation and Average Power
Standard Cable Frequency Attenuation Avg. Pwr.
1-1/4”, Black Polyethylene Jacket AT114J50 MHz dB/100 ft dB/100m kW
Fire Retardant Jacket 30 0.12 0.39 29.57
1-1/4”, Low-Smoke, Non-Halogenated, 50 0.16 0.52 22.18
AT114FX50 88 0.22 0.72 16.13
Fire Retardant Jacket, IEC332-1
Riser Rated Cable 100 0.24 0.79 14.78
1-1/4”, Low-Smoke, Non-Halogenated, 108 0.25 0.82 14.19
Fire Retardant Jacket, UL-1666, CMR, AT114R50 150 0.29 0.95 12.24
IEC332-1, IEC332-3C 174 0.32 1.05 11.09
Physical Dimensions 200 0.34 1.12 10.44
Center Dia., in (mm) 0.590 (14.98) 300 0.43 1.41 8.25
Dia. Over Dielectric, in (mm) 1.480 (37.59) 400 0.51 1.67 6.96
Dia. Over Outer Conductor, in (mm) 1.524 (38.71) 450 0.54 1.77 6.57
Max. Dia. Over Jacket, in (mm) 1.654 (42.01) 500 0.58 1.90 6.12
Center Conductor Solid Copper Tube 512 0.59 1.94 6.01
Outer Conductor Solid Aluminum Tube 600 0.64 2.10 5.54
700 0.70 2.30 5.07
Electrical Characteristics 800 0.76 2.49 4.67
Maximum Frequency, GHz 3.4 824 0.77 2.53 4.61
Peak Power Rating, KW 211 894 0.81 2.66 4.38
DC Res, Ohms/1000 ft (1000m) 960 0.85 2.79 4.17
Center 0.30 (0.99) 1000 0.87 2.85 4.08
Outer 0.12 (0.42) 1250 0.99 3.25 3.58
DC Breakdown, kV 9 1500 1.11 3.64 3.20
1800 1.25 4.10 2.87
Capacitance, pF/ft (m) 22.3 (73.16)
1900 1.29 4.23 2.76
Inductance, mH/ft (m) 0.056 (0.184)
2000 1.33 4.36 2.67
Jacket Spark, kV RMS 8
2300 1.45 4.76 2.44
Typical VSWR < 1.1
3000 1.84 6.04 1.93
Impedance, Ohms 50
Velocity of Propagation 91%
Standard conditions:
Mechanical Characteristics o
For attenuation, VSWR 1.0, ambient temperature 20 C
o
Min. Bend. Rad., in (mm) – Single 6 (152.4) (68 F)
Min. Bend. Rad., in (mm) – Multiple 15 (381) For average power, VSWR 1.0, ambient temperature
o o o o
40 C (104 F), inner conductor temperature 100 C (212 F),
Cable Weight, lb/ft (kg/m) 0.53 (0.789) no solar loading
Bending Moment, ft.lb (N.m) 50 (67.5)
Tensile Strength, lb (kg) 1124 (511)
Flat Plate Crush, lb/in (kg/mm) 122 (2.18)
Number of Bends 20
Temperature, oF (oC)
Recommended Install -40 to 170 (-40 to 77) NEW
Recommended Storage -94 to 170 (-70 to 77)
Operating -40 to 170 (-40 to 77)

800-TRILOGY (874–5649) • 601-932-4461 • www.trilogycoax.com 8/08


AirCell TRANSLINE CABLE
®

Cable Specifications
50 Ohm Transline Cable 1-5/8˝
Description Product Number
Attenuation and Average Power
Standard Cable Frequency Attenuation Avg. Pwr.
1-5/8”, Black Polyethylene Jacket AT158J50 MHz dB/100 ft dB/100m kW
Fire Retardant Jacket 30 0.09 0.33 39.16
1-5/8”, Low-Smoke, Non-Halogenated, 50 0.13 0.43 30.16
AT158FX50
Fire Retardant Jacket, IEC332-1 88 0.17 0.57 24.87
Riser Rated Cable 100 0.18 0.61 20.67
1-5/8”, Low-Smoke, Non-Halogenated, 108 0.19 0.64 20.00
Fire Retardant Jacket, UL-1666, CMR, AT158R50
IEC332-1, IEC332-3C 150 0.23 0.76 16.55
Physical Dimensions 174 0.25 0.82 12.65
Center Dia., in (mm) 0.728 (18.49) 200 0.27 0.89 14.09
Dia. Over Dielectric, in (mm) 1.871 (47.52) 300 0.33 1.10 11.19
Dia. Over Outer Conductor, in (mm) 1.888 (47.96) 400 0.39 1.29 9.47
Max. Dia. Over Jacket, in (mm) 2.035 (51.69) 450 0.42 1.39 8.85
Center Conductor Solid Copper Tube 500 0.44 1.46 8.31
Outer Conductor Solid Aluminum Tube 512 0.45 1.49 8.19
600 0.49 1.62 7.46
Electrical Characteristics 700 0.54 1.78 6.80
Maximum Frequency, GHz 3 800 0.58 1.93 6.26
Peak Power Rating, KW 315 824 0.59 1.97 6.24
DC Res, Ohms/1000 ft (1000m) 894 0.62 2.04 5.93
Center 0.22 (0.72) 960 0.64 2.13 5.56
Outer 0.10 (0.33) 1000 0.67 2.20 5.46
DC Breakdown, kV 11 1250 0.75 2.47 4.75
Capacitance, pF/ft (m) 22.3 (73.16)
1500 0.85 2.80 4.23
Inductance, mH/ft (m) 0.056 (0.184)
1800 0.96 3.02 3.76
Jacket Spark, kV RMS 8
1900 0.99 3.26 3.62
Typical VSWR < 1.1
2000 1.01 3.34 3.51
Impedance, Ohms 50
Velocity of Propagation 91% 2300 1.10 3.61 3.20
3000 1.36 4.46 2.44
Mechanical Characteristics
Min. Bend. Rad., in (mm) – Single 8 (203)
Standard conditions:
Min. Bend. Rad., in (mm) – Multiple 20 (508) o
For attenuation, VSWR 1.0, ambient temperature 20 C
Cable Weight, lb/ft (kg/m) 0.70 (1.037) o
(68 F)
Bending Moment, ft.lb (N.m) 60 (81) For average power, VSWR 1.0, ambient temperature
o o o o
Tensile Strength, lb (kg) 1500 (682) 40 C (104 F), inner conductor temperature 100 C (212 F),
no solar loading
Flat Plate Crush, lb/in (kg/mm) 150 (2.68)
Number of Bends 20
Temperature, oF (oC)
Recommended Install
Recommended Storage
-40 to 170 (-40 to 77)
-94 to 170 (-70 to 77)
NEW
Operating -40 to 170 (-40 to 77)

800-TRILOGY (874–5649) • 601-932-4461 • www.trilogycoax.com 8/08


AirCell TRANSLINE CABLE
®

Cable Specifications
75 Ohm Transline Cable 1/2˝
Description Product Number
Attenuation and Average Power
Standard Cable Frequency Attenuation Avg. Pwr.
½”, Black Polyethylene Jacket AT012J75 MHz dB/100 ft dB/100m kW
Fire Retardant Jacket 30 0.35 1.15 3.21
½”, Low-Smoke, Non-Halogenated, 50 0.45 1.48 2.50
AT012FX75
Fire Retardant Jacket, IEC332-1 88 0.61 2.00 1.84
½”, Low-Smoke, Non-Halogenated,
AT012F75 100 0.65 2.13 1.73
Fire Retardant Jacket, IEC332-1, MSHA
108 0.67 2.20 1.68
Riser Rated Cable
½”, Low-Smoke, Non-Halogenated, 150 0.77 2.53 1.45
Fire Retardant Jacket, UL-1666, CMR, AT012R75 174 0.85 2.79 1.32
IEC332-1, IEC332-3C 200 0.92 3.02 1.22
Physical Dimensions 300 1.14 3.74 0.99
Center Dia., in (mm) 0.123 (3.12) 400 1.32 4.33 0.85
Dia. Over Dielectric, in (mm) 0.470 (11.94) 450 1.40 4.59 0.80
Dia. Over Outer Conductor, in (mm) 0.510 (12.95) 500 1.48 4.86 0.76
Max. Dia. Over Jacket, in (mm) 0.652 (16.56) 512 1.50 4.92 0.75
Center Conductor Copper-Clad Aluminum 600 1.63 5.35 0.69
Outer Conductor Solid Aluminum
700 1.76 5.77 0.64
800 1.91 6.27 0.59
Electrical Characteristics
824 1.94 6.36 0.58
Maximum Frequency, GHz 11
894 2.02 6.63 0.56
Peak Power Rating, KW 32
960 2.10 6.89 0.53
DC Res, Ohms/1000 ft (1000m)
1000 2.15 7.05 0.52
Center 1.09 (3.58)
1250 2.39 7.84 0.47
Outer 0.46 (1.51)
1500 2.60 8.53 0.43
DC Breakdown, kV 3.2
1800 2.86 9.38 0.39
Capacitance, pF/ft (m) 14.9 (48.9)
Inductance, mH/ft (m) 0.082 (0.269) 1900 2.94 9.65 0.38
Jacket Spark, kV RMS 8 2000 3.03 9.94 0.37
Typical VSWR 1.3 2300 3.26 10.70 0.34
Impedance, Ohms 75 3000 3.72 12.20 0.30
Velocity of Propagation 93%

Mechanical Characteristics Standard conditions:


o
Min. Bend. Rad., in (mm) – Single 2 (50.8) For attenuation, VSWR 1.0, ambient temperature 20 C
o
(68 F)
Min. Bend. Rad., in (mm) – Multiple 6 (152) For average power, VSWR 1.0, ambient temperature
o o o o
Cable Weight, lb/ft (kg/m) 0.10 (0.15) 40 C (104 F), inner conductor temperature 100 C (212 F),
no solar loading
Bending Moment, ft.lb (N.m) 7.5 (10.2)
Tensile Strength, lb (kg) 465 (211)
Flat Plate Crush, lb/in (kg/mm) 62 (1.11)
Number of Bends 20
Temperature, oF (oC)
Recommended Install -40 to 170 (-40 to 77)
NEW
Recommended Storage -94 to 170 (-70 to 77)
Operating -40 to 170 (-40 to 77)

800-TRILOGY (874–5649) • 601-932-4461 • www.trilogycoax.com 8/08


AirCell TRANSLINE CABLE
®

Cable Specifications
75 Ohm Transline Cable 5/8˝
Description Product Number
Attenuation and Average Power
Standard Cable Frequency Attenuation Avg. Pwr.
5/8”, Black Polyethylene Jacket AT058J75 MHz dB/100 ft dB/100m kW
Fire Retardant Jacket 30 0.25 0.82 5.76
5/8”, Low-Smoke, Non-Halogenated, 50 0.32 1.05 4.50
AT058FX75 88 0.43 1.41 3.35
Fire Retardant Jacket, IEC332-1
Riser Rated Cable 100 0.46 1.51 3.13
5/8”, Low-Smoke, Non-Halogenated, 108 0.48 1.57 3.00
Fire Retardant Jacket, UL-1666, CMR, AT058R75 150 0.56 1.84 2.68
IEC332-1, IEC332-3C 174 0.60 1.97 2.40
Physical Dimensions 200 0.65 2.13 2.22
Center Dia., in (mm) 0.185 (4.7) 300 0.79 2.59 1.82
Dia. Over Dielectric, in (mm) 0.712 (18.08) 400 0.91 2.99 1.58
Dia. Over Outer Conductor, in (mm) 0.760 (19.30) 450 0.97 3.18 1.48
Max. Dia. Over Jacket, in (mm) 0.892 (22.65) 500 1.03 3.38 1.40
Center Conductor Copper Clad Aluminum 512 1.04 3.41 1.38
Outer Conductor Solid Aluminum Tube 600 1.11 3.64 1.30
700 1.20 3.94 1.20
Electrical Characteristics 800 1.30 4.27 1.11
Maximum Frequency, GHz 8 824 1.32 4.33 1.09
Peak Power Rating, KW 38 894 1.37 4.49 1.05
DC Res, Ohms/1000 ft (1000m) 960 1.44 4.72 1.00
Center 0.46 (1.51) 1000 1.47 4.82 0.99
Outer 0.23 (0.76) 1250 1.62 5.31 0.89
DC Breakdown, kV 4.75 1500 1.77 5.81 0.81
1800 1.95 6.40 0.74
Capacitance, pF/ft (m) 14.9 (48.9)
1900 2.01 6.59 0.72
Inductance, mH/ft (m) 0.083 (0.273)
2000 2.07 6.79 0.70
Jacket Spark, kV RMS 8
2300 2.29 7.51 0.63
Typical VSWR < 1.1
3000 2.62 8.59 0.55
Impedance, Ohms 75
Velocity of Propagation 93%
Standard conditions:
Mechanical Characteristics o
For attenuation, VSWR 1.0, ambient temperature 20 C
o
Min. Bend. Rad., in (mm) – Single 3 (76.2) (68 F)
Min. Bend. Rad., in (mm) – Multiple 8 (203) For average power, VSWR 1.0, ambient temperature
o o o o
40 C (104 F), inner conductor temperature 100 C (212 F),
Cable Weight, lb/ft (kg/m) 0.20 (0.29) no solar loading
Bending Moment, ft.lb (N.m) 21 (28.5)
Tensile Strength, lb (kg) 500 (227)
Flat Plate Crush, lb/in (kg/mm) 140 (2.50)
Number of Bends
Temperature, oF (oC)
20
NEW
Recommended Install -40 to 170 (-40 to 77)
Recommended Storage -94 to 170 (-70 to 77)
Operating -40 to 170 (-40 to 77)

800-TRILOGY (874–5649) • 601-932-4461 • www.trilogycoax.com 8/08


AirCell TRANSLINE CABLE
®

Cable Specifications
75 Ohm Transline Cable 7/8˝
Description Product Number
Attenuation and Average Power
Standard Cable Frequency Attenuation Avg. Pwr.
7/8”, Black Polyethylene Jacket AT078J75 MHz dB/100 ft dB/100m kW
Fire Retardant Jacket 30 0.18 0.59 9.46
7/8”, Low-Smoke, Non-Halogenated, 50 0.23 0.75 7.41
AT078FX75 88 0.30 0.98 5.68
Fire Retardant Jacket, IEC332-1
Riser Rated Cable 100 0.32 1.05 5.32
7/8”, Low-Smoke, Non-Halogenated, 108 0.34 1.12 5.01
Fire Retardant Jacket, UL-1666, CMR, AT078R75 150 0.40 1.31 4.51
IEC332-1, IEC332-3C 174 0.43 1.41 3.96
Physical Dimensions 200 0.46 1.51 3.70
Center Dia., in (mm) 0.248 (6.30) 300 0.60 1.97 2.84
Dia. Over Dielectric, in (mm) 0.961 (24.41) 400 0.70 2.30 2.43
Dia. Over Outer Conductor, in (mm) 1.015 (25.78) 450 0.74 2.43 2.30
Max. Dia. Over Jacket, in (mm) 1.147 (29.13) 500 0.78 2.56 2.18
Center Conductor Copper Clad Aluminum 512 0.79 2.59 2.16
Outer Conductor Solid Aluminum Tube 600 0.87 2.85 1.96
700 0.94 3.08 1.81
Electrical Characteristics 800 1.02 3.35 1.67
Maximum Frequency, GHz 6 824 1.04 3.41 1.64
Peak Power Rating, KW 68 894 1.08 3.54 1.58
DC Res, Ohms/1000 ft (1000m) 960 1.13 3.71 1.51
Center 0.26 (0.85) 1000 1.16 3.81 1.49
Outer 0.15 (0.49) 1250 1.30 4.26 1.31
DC Breakdown, kV 6.4 1500 1.45 4.76 1.17
1800 1.62 5.31 1.06
Capacitance, pF/ft (m) 14.9 (48.9)
1900 1.68 5.51 1.02
Inductance, mH/ft (m) 0.083 (0.273)
2000 1.74 5.71 0.98
Jacket Spark, kV RMS 8
2300 1.89 6.20 0.90
Typical VSWR < 1.1
3000 2.16 7.09 0.79
Impedance, Ohms 75
Velocity of Propagation 93%
Standard conditions:
Mechanical Characteristics o
For attenuation, VSWR 1.0, ambient temperature 20 C
o
Min. Bend. Rad., in (mm) – Single 8 (203) (68 F)
Min. Bend. Rad., in (mm) – Multiple 10 (254) For average power, VSWR 1.0, ambient temperature
o o o o
40 C (104 F), inner conductor temperature 100 C (212 F),
Cable Weight, lb/ft (kg/m) 0.35 (0.47) no solar loading
Bending Moment, ft.lb (N.m) 35 (47.5)
Tensile Strength, lb (kg) 830 (377)
Flat Plate Crush, lb/in (kg/mm) 132 (2.36)
Number of Bends 20
Temperature, oF (oC) NEW
Recommended Install -40 to 170 (-40 to 77)
Recommended Storage -94 to 170 (-70 to 77)
Operating -40 to 170 (-40 to 77)

800-TRILOGY (874–5649) • 601-932-4461 • www.trilogycoax.com 8/08


TRANSLINE CABLE

Hardware and Accessories


Accessories for AirCell® Transline Cable, 1/2"
Description Product Code Description Product Code

A. Cable Hoisting and Attachment Metal Snips- Each MT-646


Banding Kit- Each MT-647
Hoisting Grips Trapeze Kits- Each
Lace-Up Hoisting Grips- Each HG-12 12" wide MT-357-12
Pre-Laced Hoisting Grips- Each HG-12L 24"wide MT-357-24
Tie Wraps- Pkg. of 50 TW-50
Coax Support Blocks
Mini Coax Support Blocks- Pkg. of 10 CB-12
B.Weatherproofing
Large Coax Support Blocks- Pkg. of 10 CB-12L 3M Cold Shrink Weatherproofing Kits
Mounting Hardware Kits for Support Blocks Splices:
Galvanized. One Block- Pkg. of 10 HK-SSCB 1/2" to 1/2" CS-U1212
Galvanized.Two Blocks- Pkg. of 10 HK-DSCB Main Feed to Jumper:
Galvanized.Three Blocks- Pkg. of 10 HK-TSCB 7/8" to 1/2" CS-U1278
Stainless Steel. Starter Kit- Pkg. of 10 HK-SCBL 1 5/8" to 1/2" CS-U1258
Stainless Steel. Extender Kit- Pkg. of 10 HK-ECBL
Universal Weatherproofing Kit WK-U
Adaptors
Round Member Adaptors- Pkg. of 10 Assorted Tapes and Mastics- Each
1"-2" (RM-A100) 2"-3" (RM-A200 Electrical Tape. 3/4" x 44’ roll MT-464
3"-4" (RM-A300) 4"-5" (RM-A400) Electrical Tape. 2" x 66’ roll MT-465
Universal Round Member Adaptors Electrical Tape. 2" x 20’ roll MT-465-1
Galvanized Version- Pkg. of 10 RM-USBG Mastic Tape. 3 3/4" x 2’ roll MT-469-2
Stainless Steel Version- Pkg. of 10 RM-USBS Vinyl-baked Mastic Tape. 2" x 3’ roll MT-2228
Universal Round Member Hardware- Pkg. of 10 RM-BU C. Cable Entry
Universal Stainless Steel Angle Adaptors- Pkg. of 10 AA-U/AA-US
Stainless Steel Angle Adaptors- Pkg. of 10 AA-SL Tube Entry Kits- Each
Aluminum Angle Adaptors- Pkg. of 10 AA-AM 12" Long MT-101
Universal Stand-Off Adaptors- Pkg. of 10 18" Long MT-102
Universal Version, Galvanized: 24" Long MT-103
1"-2" (SA-UG100) 2"-3" (SA-UG200)
3"-4" (SA-UG300) 4"-5" (SA-UG400) Cushion Plugs and Inserts
Universal Version, Stainless Steel: Cushion Plugs- Pkg. of 5 CP-12
1"-2" (SA-US100) 2"-3" (SA-US200) Cushion Inserts- Each
3"-4" (SA-US300) 4"-5" (SA-US400) Rectangular Port Cushion with 6 holes for 1/2" RC-12
Snap-In Version, Galvanized: Standard Port Cushion with 1 hole for 1/2" SC-12-1
1"-2" (SA-SG100) 2"-3" (SA-SG200) Standard Port Cushion with 2 holes for 1/2" SC-12-2
3"-4" (SA-SG300) 4"-5" (SA-SG400) Standard Port Cushion with 3 holes for 1/2" SC-12-3
Snap-In Version, Stainless Steel: Standard Port Cushion with 4 holes for 1/2" SC-12-4
1"-2" (SA-SS100) 2"-3" (SA-SS200) Entry Panels* EP-XXX
3"-4" (SA-SS300) 4"-5" (SA-SS400) BA-XXX

Hangers D. Ground Kits


Stainless Steel Butterfly Hangers-Pkg. of 10 BH-12 Standard Ground Kits- Each GK-S12AC
Stainless Steel Clip Hangers- Pkg. of 10 CH-12
Universal Snap-in Hangers- Pkg. of 10 SH-U12 Mounting Hardware
Crimping Tool- Each MT-639
Banding Hardware
1/2" Stainless Steel Banding, 100’ RolL MT-640
Tools
1/2" All-in One Cable Prep Tool- CT01250AIO
1/2" Stainless Steel Buckle Clamps- Pkg. of 100 MT-641
High Leverage Cable Cutter- Each TC63050
1/2" Galvanized Banding, 100’ RolL MT-642
Tubing Cutter- Each TC1000
1/2" Galvanized Buckle Clamps- Pkg. of 100 MT-643
Knife-Box Cutter- Each TC10099
C-2 Banding Tool MT-644
Cable Markers- Pkg. of 10 CM-12X*-2
12oz. Hammer MT-645

* Please Refer to Hardware and Accessories for full line of these products

8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m 24
TRANSLINE CABLE
Accessory Selection Information/Product Code

Accessories for AirCell® Transline Cable, 5/8"


Description Product Code Description Product Code

A. Cable Hoisting and Attachment Metal Snips- Each MT-646


Banding Kit- Each MT-647
Hoisting Grips Trapeze Kits- Each
Lace-Up Hoisting Grips- Each HG-58 12" wide MT-357-12
Pre-Laced Hoisting Grips- Each HG-58L 24"wide MT-357-24
Tie Wraps- Pkg. of 50 TW-50
Adaptors
Round Member Adaptors- Pkg. of 10 B.Weatherproofing
1"-2" (RM-A100) 2"-3" (RM-A200)
3"-4" (RM-A300) 4"-5" (RM-A400) Universal Weatherproofing Kit WK-U
Universal Round Member Adaptors
Galvanized Version- Pkg. of 10 RM-USBG Assorted Tapes and Mastics- Each
Stainless Steel Version- Pkg. of 10 RM-USBS Electrical Tape. 3/4" x 44’ roll MT-464
Universal Round Member Hardware- Pkg. of 10 RM-BU Electrical Tape. 2" x 66’ roll MT-465
Universal Stainless Steel Angle Adaptors- Pkg. of 10 AA-U/AA-US Electrical Tape. 2" x 20’ roll MT-465-1
Stainless Steel Angle Adaptors- Pkg. of 10 AA-SL Mastic Tape. 3 3/4" x 2’ roll MT-469-2
Aluminum Angle Adaptors- Pkg. of 10 AA-AM Vinyl-baked Mastic Tape. 2" x 3’ roll MT-2228
Universal Stand-Off Adaptors- Pkg. of 10
Universal Version, Galvanized: C. Cable Entry
1-2" (SA-UG100) 2-3" (SA-UG200)
3-4" (SA-UG300) 4-5" (SA-UG400) Tube Entry Kits- Each
Universal Version, Stainless Steel: 12" Long MT-101
1-2" (SA-US100) 2-3" (SA-US200) 18" Long MT-102
3-4" (SA-US300) 4-5" (SA-US400) 24" Long MT-103
Snap-In Version, Galvanized:
1-2" (SA-SG100) 2-3" (SA-SG200) Cushion Plugs and Inserts
3-4" (SA-SG300) 4-5" (SA-SG400) Cushion Inserts- Each
Snap-In Version, Stainless Steel: Standard Port Cushion with 1 hole for 5/8" SC-58-1
1-2" (SA-SS100) 2-3" (SA-SS200)
3-4" (SA-SS300) 4-5" (SA-SS400) Entry Panels* EP-XXX
Hangers BA-XXX
Stainless Steel Butterfly Hangers- Pkg. of 10 BH-58 D. Ground Kits
Universal Snap-in Hangers- Pkg. of 10 SH-U58
Standard Ground Kits- Each GK-S58AC
Banding Hardware
1/2" Stainless Steel Banding, 100’ Roll MT-640 Mounting Hardware
1/2" Stainless Steel Buckle Clamps - Pkg. of 10 MT-641 Crimping Tool- Each MT-639
1/2" Galvanized Banding, 100’ Roll MT-642
1/2" Galvanized Buckle Clamps - Pkg. of 10 MT-643 Tools
C-2 Banding Tool MT-644 1/2" All-in One Cable Prep Tool CT05850AIO
12oz. Hammer MT-645 High Leverage Cable Cutter- Each TC63050
Tubing Cutter- Each TC1000
Knife-Box Cutter- Each TC10099
Cable Markers- Pkg. of 10 CM-12X*-2

* Please Refer to Hardware and Accessories for full line of these products

25 8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
TRANSLINE CABLE
Accessory Selection Information/Product Code

Accessories for AirCell® Transline Cable, 7/8"


Description Product Code Description Product Code

A. Cable Hoisting and Attachment Metal Snips- Each MT-646


Banding Kit- Each MT-647
Hoisting Grips Trapeze Kits- Each
Lace-Up Hoisting Grips- Each HG-78 12" wide MT-357-12
Pre-Laced Hoisting Grips- Each HG-78L 24"wide MT-357-24
Tie Wraps- Pkg. of 50 TW-50
Coax Support Blocks
Mini Coax Support Blocks- Pkg. of 10 CB-78 B.Weatherproofing
Large Coax Support Blocks- Pkg. of 10 CB-78L 3M™ Cold Shrink™ Weatherproofing Kits
Mounting Hardware Kits for Support Blocks- Splices:
Galvanized. One Block- Pkg. of 10 HK-SSCB 7/8" to 7/8" CS-U1278
Galvanized.Two Blocks- Pkg. of 10 HK-DSCB Main Feed to Jumper:
Galvanized.Three Blocks- Pkg. of 10 HK-TSCB 7/8" to 1/2" CS-U1278
Stainless Steel. Starter Kit- Pkg. of 10 HK-SCBL
Stainless Steel. Extender Kit- Pkg. of 10 HK-ECBL Universal Weatherproofing Kit WK-U

Adaptors Assorted Tapes and Mastics- Each


Round Member Adaptors- Pkg. of 10 Electrical Tape. 3/4" x 44’ roll MT-464
1"-2" (RM-A100) 2"-3" (RM-A200) Electrical Tape. 2" x 66’ roll MT-465
3"-4" (RM-A300) 4"-5" (RM-A400) Electrical Tape. 2" x 20’ roll MT-465-1
Universal Round Member Adaptors Mastic Tape. 3 3/4" x 2’ roll MT-469-2
Galvanized Version- Pkg. of 10 RM-USBG Vinyl-baked Mastic Tape. 2" x 3’ roll MT-2228
Stainless Steel Version- Pkg. of 10 RM-USBS C. Cable Entry
Universal Round Member Hardware- Pkg. of 10 RM-BU
Universal Stainless Steel Angle Adaptors- Pkg. of 10 AA-U/AA-US Tube Entry Kits- Each
Stainless Steel Angle Adaptors- Pkg. of 10 AA-SL 12" Long MT-101
Aluminum Angle Adaptors- Pkg. of 10 AA-AM 18" Long MT-102
Universal Stand-Off Adaptors- Pkg. of 10 24" Long MT-103
Universal Version, Galvanized:
1-2" (SA-UG100) 2-3" (SA-UG200) Cushion Plugs and Inserts
3-4" (SA-UG300) 4-5" (SA-UG400) Cushion Plugs- Pkg. of 5 CP-78
Universal Version, Stainless Steel: Cushion Inserts- Each
1-2" (SA-US100) 4-5" (SA-US400) Rectangular Port Cushion with 4 holes for 7/8" RC-78
Snap-In Version, Galvanized: Standard Port Cushion with 1 hole for 7/8" SC-78-1
1-2" (SA-SG100) 2-3" (SA-SG200) Standard Port Cushion with 2 holes for 7/8" SC-78-2
3-4" (SA-SG300 4-5" (SA-SG400) Standard Port Cushion with 3 holes for 7/8" SC-78-3
Snap-In Version, Stainless Steel: Standard Port Cushion with 4 holes for 7/8" SC-78-4
1-2" (SA-SS100) 2-3" (SA-SS200) Entry Panels* EP-XXX
3-4" (SA-SS300) 4-5" (SA-SS400) BA-XXX
D. Ground Kits
Hangers
Stainless Steel Butterfly Hangers- Pkg. of 10 BH-78 Standard Ground Kits- Each GK-S78AC
Stainless Steel Clip Hangers- Pkg. of 10 CH-78
Universal Snap-in Hangers- Pkg. of 10 SH-U78 Mounting Hardware
Crimping Tool- Each MT-639
Banding Hardware
1/2" Stainless Steel Banding, 100’ Roll MT-640 Tools
1/2" Stainless Steel Buckle Clamps- Pkg. of 10 MT-641 1/2" All-in One Cable Prep Tool CT07850AIO
1/2" Galvanized Banding, 100’ Roll MT-642 High Leverage Cable Cutter- Each TC63050
1/2" Galvanized Buckle Clamps- Pkg. of 10 MT-643 Tubing Cutter- Each TC1000
C-2 Banding Tool MT-644 Knife-Box Cutter- Each TC10099
12oz. Hammer MT-645 Cable Markers- Pkg. of 10 CM-78X*-2

* Please Refer to Hardware and Accessories for full line of these products

8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m 26
® TRANSLINE CABLE

AirCell
Accessories for AirCell® Transline Cable, 1-1/4"
Accessory Selection Information/Product Code

Description Product Code Description Product Code

A. Cable Hoisting and Attachment C-2 Banding Tool MT-644


12oz. Hammer MT-645
Hoisting Grips Metal Snips- Each MT-646
Lace-Up Hoisting Grips- Each HG-114 Banding Kit- Each MT-647
Pre-Laced Hoisting Grips- Each HG-114L Trapeze Kits- Each
12" wide MT-357-12
Coax Support Blocks 24"wide MT-357-24
Mini Coax Support Blocks- Pkg. of 10 CB-114 Tie Wraps- Pkg. of 50 TW-50
Large Coax Support Blocks- Pkg. of 10 CB-114L
Mounting Hardware Kits for one 1 1/4" Support Blocks- B.Weatherproofing
Galvanized. One Block- Pkg. of 10 HK-SSCB158
Galvanized.Two Blocks- Pkg. of 10 HK-DSCB158 3M Cold Shrink Weatherproofing Kits
Galvanized.Three Blocks- Pkg. of 10 HK-TSCB158 Splices:
Stainless Steel. Starter Kit- Pkg. of 10 HK-SCBL158 1 1/4" to 1 5/8" CS-U12158
Stainless Steel. Extender Kit- Pkg. of 10 HK-ECBL158 Main Feed to Jumper:
1 1/4" to 1/2" CS-U12158
Adaptors
Round Member Adaptors- Pkg. of 10 Universal Weatherproofing Kit WK-U
1"-2" (RM-A100) 2"-3" (RM-A200)
3"-4" (RM-A300) 4"-5" (RM-A400) Assorted Tapes and Mastics- Each
Universal Round Member Adaptors Electrical Tape. 3/4" x 44’ roll MT-464
Galvanized Version- Pkg. of 10 RM-USBG Electrical Tape. 2" x 66’ roll MT-465
Stainless Steel Version- Pkg. of 10 RM-USBS Electrical Tape. 2" x 20’ roll MT-465-1
Universal Round Member Hardware- Pkg. of 10 RM-BU Mastic Tape. 3 3/4" x 2’ roll MT-469-2
Universal Stainless Steel Angle Adaptors- Pkg. of 10 AA-U/AA-US Vinyl-baked Mastic Tape. 2" x 3’ roll MT-2228
Stainless Steel Angle Adaptors- Pkg. of 10 AA-SL
Aluminum Angle Adaptors- Pkg. of 10 AA-AM C. Cable Entry
Universal Stand-Off Adaptors- Pkg. of 10
Universal Version, Galvanized: Tube Entry Kits- Each
1-2" (SA-UG100) 2-3" (SA-UG200) 12" Long MT-101
3-4" (SA-UG300) 4-5" (SA-UG400) 18" Long MT-102
Universal Version, Stainless Steel: 24" Long MT-103
1-2" (SA-US100) 2-3" (SA-US200)
3-4" (SA-US300) 4-5" (SA-US400) Cushion Plugs and Inserts
Snap-In Version, Galvanized: Cushion Plugs
1-2" (SA-SG100) 2-3" (SA-SG200) Cushion Inserts
3-4" (SA-SG300) 4-5" (SA-SG400) Rectangular
Snap-In Version, Stainless Steel: Standard Port Cushion with 1 hole for 1-1/4" SC-114-1
1-2" (SA-SS100) 2-3" (SA-SS200)
3-4" (SA-SS300) 4-5" (SA-SS400) Entry Panels* EP-XXX
BA-XXX
Hangers D. Ground Kits
Stainless Steel Butterfly Hangers- Pkg. of 10 BH-114
Stainless Steel Clip Hangers- Pkg. of 10 CH-114 Standard Ground Kits- Each GK-S114/158AC
Universal Snap-in Hangers- Pkg. of 10 SH-U114
MOUNTING HARDWARE
Banding Hardware Crimping Tool- Each MT-639
1/2" Stainless Steel Banding, 100’ Roll MT-640
1/2" Stainless Steel Buckle Clamps- Pkg. of 100 MT-641 TOOLS
1/2" Galvanized Banding, 100’ Roll MT-642 1/2" All-in One Cable Prep Tool CT15850AIO
1/2" Galvanized Buckle Clamps- Pkg. of 100 MT-643 High Leverage Cable Cutter- Each TC63050
Tubing Cutter- Each TC1000
Knife-Box Cutter- Each TC10099
Cable Markers- Pkg. of 10 CM-158X*-2

* Please Refer to Hardware and Accessories for full line of these products

27 8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
TRANSLINE CABLE
Accessory Selection Information/Product Code

Accessories for AirCell® Transline Cable, 1-5/8"


Description Product Code Description Product Code

A. Cable Hoisting and Attachment C-2 Banding Tool MT-644


12oz. Hammer MT-645
Hoisting Grips Metal Snips- Each MT-646
Lace-Up Hoisting Grips- Each HG-158 Banding Kit- Each MT-647
Pre-Laced Hoisting Grips- Each HG-158L Trapeze Kits- Each
12" wide MT-357-12
Coax Support Blocks 24"wide MT-357-24
Mini Coax Support Blocks- Pkg. of 10 CB-158 Tie Wraps- Pkg. of 50 TW-50
Large Coax Support Blocks- Pkg. of 10 CB-158L
Mounting Hardware Kits for one 1 5/8" Support Blocks- B.Weatherproofing
Galvanized. One Block- Pkg. of 10 HK-SSCB158
Galvanized.Two Blocks- Pkg. of 10 HK-DSCB158 3M Cold Shrink Weatherproofing Kits
Galvanized.Three Blocks- Pkg. of 10 HK-TSCB158 Splices:
Stainless Steel. Starter Kit- Pkg. of 10 HK-SCBL158 1 5/8" to 1 5/8" CS-U12158
Stainless Steel. Extender Kit- Pkg. of 10 HK-ECBL158 Main Feed to Jumper:
1 5/8" to 1/2" CS-U1258
Adaptors
Round Member Adaptors- Pkg. of 10 Universal Weatherproofing Kit WK-U
1"-2" (RM-A100) 2"-3" (RM-A200)
3"-4" (RM-A300) 4"-5" (RM-A400) Assorted Tapes and Mastics- Each
Universal Round Member Adaptors Electrical Tape. 3/4" x 44’ roll MT-464
Galvanized Version- Pkg. of 10 RM-USBG Electrical Tape. 2" x 66’ roll MT-465
Stainless Steel Version- Pkg. of 10 RM-USBS Electrical Tape. 2" x 20’ roll MT-465-1
Universal Round Member Hardware- Pkg. of 10 RM-BU Mastic Tape. 3 3/4" x 2’ roll MT-469-2
Universal Stainless Steel Angle Adaptors- Pkg. of 10 AA-U/AA-US Vinyl-baked Mastic Tape. 2" x 3’ roll MT-2228
Stainless Steel Angle Adaptors- Pkg. of 10 AA-SL
Aluminum Angle Adaptors- Pkg. of 10 AA-AM C. Cable Entry
Universal Stand-Off Adaptors- Pkg. of 10
Universal Version, Galvanized: Tube Entry Kits- Each
1-2" (SA-UG100) 2-3" (SA-UG200) 12" Long MT-101
3-4" (SA-UG300) 4-5" (SA-UG400) 18" Long MT-102
Universal Version, Stainless Steel: 24" Long MT-103
1-2" (SA-US100) 2-3" (SA-US200)
3-4" (SA-US300) 4-5" (SA-US400) Cushion Plugs and Inserts
Snap-In Version, Galvanized: Cushion Plugs- Pkg. of 5 CP-158
1-2" (SA-SG100) 2-3" (SA-SG200) Cushion Inserts- Each
3-4" (SA-SG300) 4-5" (SA-SG400) Rectangular Port Cushion with 2 holes for 1-5/8" RC-158
Snap-In Version, Stainless Steel: Standard Port Cushion with 1 hole for 1-5/8" SC-158-1
1-2" (SA-SS100) 2-3" (SA-SS200)
3-4" (SA-SS300) 4-5" (SA-SS400) Entry Panels* EP-XXX
BA-XXX
Hangers D. Ground Kits
Stainless Steel Butterfly Hangers- Pkg. of 10 BH-158
Stainless Steel Clip Hangers- Pkg. of 10 CH-158 Standard Ground Kits- Each GK-S158AC
Universal Snap-in Hangers- Pkg. of 10 SH-U158
MOUNTING HARDWARE
Banding Hardware Crimping Tool- Each MT-639
1/2" Stainless Steel Banding, 100’ Roll MT-640
1/2" Stainless Steel Buckle Clamps- Pkg. of 100 MT-641 TOOLS
1/2" Galvanized Banding, 100’ Roll MT-642 1/2" All-in One Cable Prep Tool CT15850AIO
1/2" Galvanized Buckle Clamps- Pkg. of 100 MT-643 High Leverage Cable Cutter- Each TC63050
Tubing Cutter- Each TC1000
Knife-Box Cutter- Each TC10099
Cable Markers- Pkg. of 10 CM-158X*-2

* Please Refer to Hardware and Accessories for full line of these products

8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m 28

You might also like