You are on page 1of 12

Conventional

Product Range
• Comply with EN54-2/4 CE

• Metallic Enclosure

• 4 - 8 Zone Capacity

• Supports Max. 32 Detectors in Each Zone

• Smart Battery Charging System

• 2x 500mA Sounder Output

• 1x Fire Relay, 1x Error Relay – NO/NC

EN54-2 / EN54-4 • Key Lock to Prevent Unauthorized Access


1922-CPR-1523
• 2x 12V 7Ah Battery

CFAS-404 Conventional Fire Alarm Panel, 4 Zone


CFAS-408 Conventional Fire Alarm Panel, 8 Zone
• Comply with EN54-7

• Optical Light Scatter Detection

• 2 LED Indicator Enables 360° View

• Special Software Algorithms to Prevent Faulty Alarms

• Metallic Cage to Prevent Entrance Foreign Objects

• Easy to Clean Smoke Chambers


EN54-7 • Pollution Warning by LED Indicator
1922-CPR-1529

OSD-3230 Conventional Smoke Detector


• Comply with EN54-5

• Designed with 2pcs NTC to Ensure Precise Measurement

• Supports Fixed Heat Detection, A2S

• 2 LED Indicator Enables 360° View

• Special Software Algorithms to Prevent Faulty Alarms

EN54-5
1922-CPR-1528

HD-3240 Conventional Fixed Heat Detector


• Comply with EN54-7 and EN54-5

• Supports Optical Smoke and Fixed Heat Detection

• Designed with 2pcs NTC to Ensure Precise Measurement

• 2 LED Indicator Enables 360° View

• Special Software Algorithms to Prevent Faulty Alarms

• Easy to Clean Smoke Chambers

EN54-7 / EN54-5 • Pollution Warning by LED Indicator


1922-CPR-1527

MD-3250 Conventional Multi Detector


• LPCB Approved, CE – UKCA Certified

• Comply with EN54-7 and EN54-5

• 4 Types of Detector

• Optical Smoke Detector

• Fixed Heat Detector, A2S

• Rate of Rise Heat Detector, A2R

• Multi Detector, Smoke and Fixed Heat

New Conventional Detectors


• Comply with EN54-11

• Resettable, Non-Glass Break

• Flush and Surface Mounting

• Supports MCPC-0165 Protection Cover

• Includes Reset Key

• NO/NC Connection Support


EN54-5
1922-CPR-1522

MCP-3165 Conventional Manual Call Point


• Comply with EN54-3

• 100dB ±2 Sound Level

• Type A - IP21C Protection Class

• UL94 non-flammable Polycarbonate Plastic Enclosure

• 15mA Alarm Consumption

• RED or White Color Options

EN54-5 • Internal Usage - Wall Mount


1922-CPR-1525

SND-3191R Conventional Sounder, Red


SND-3191W Conventional Sounder, White
• Comply with EN54-3 and EN54-23

• 100dB ±2 Sound Level

• W-2,4-4 Coverage

• Type A - IP21C Protection Class

• UL94 non-flammable Polycarbonate Plastic Case

• 19mA Alarm Consumption

• RED or White Color Options


EN54-5
1922-CPR-1524 • Internal Usage - Wall Mount

STTR-3192R Conventional Sounder With Beacon, Red


STTR-3192W Conventional Sounder With Beacon, White
• EN54-23 Certified

• Type A - IP21C Protection Class

• W-2,4-4 Coverage

• UL94 non-flammable Polycarbonate Plastic Case

• 6mA Alarm Consumption

• RED or White Color Options


EN54-5 • Internal Usage - Wall Mount
1922-CPR-1531

STR-3193R Conventional Beacon, Red


STR-3193W Conventional Beacon, White