Professional Documents
Culture Documents
DX - A New Gauge Panel Manaul Without Jog Switch
DX - A New Gauge Panel Manaul Without Jog Switch
Overview
Machine condition is displayed in the letter information display
department. The information display department is divided into
two menus. One is main menu for the user and the other is a
special menu for the specialist. These menus can be changed
from normal display mode by the combination of selector button.
AM
H H
E F
C C
rpm
S USB
1
EX1501577
Figure 11
Access Method
1. Proceed to the user menu using the menu/ESC button on
the front of the dashboard.
2. Select the user menu from the launch menu.
PM PM
User Menu
H H
E F
C C Machine State Machine Gauge Panel
Configuration Configuration
rpm
S USB S USB
Escape Method
1. Press the ESC button to move to the normal display screen.
2. If 20 seconds have passed without the operation of the
button, the normal display screen will be displayed.
3. Turning "OFF" the starter switch to cut off power, you will
move to the normal display screen.
User Menu
PM
Use the and buttons and move the cursor to see a User Menu
reversed display on the desired menu. Then, press the
button to select the menu.
Machine State Machine Configuration Gauge Panel
Configuration Machine State Machine Gauge Panel
Configuration Configuration
Press the ESC button to return to the previous screen.
S USB
WARNING
EX1402099
Figure 13
A. Monitoring
Monitoring
The monitoring screen displays the information on Front Pump Pressure Rear Pump Pressure Battery Voltage
machine pump pressure, voltage, fuel level, etc.
bar bar bar
Monitoring, press the button to display the Engine Dial Voltage Fuel Level Engine Speed
Monitoring screen.
bar v %
screen.
FG018483
Figure 15
B. Filter/Oil Information
PM
The screen displays the information on filter/oil use Machine State
time, replacement period, and remaining time.
Monitoring
At the machine state, if the cursor is placed on the
Filter/Oil Information
filter/oil information, press the button to display
the filter/oil information. Machine Information
S USB
EX1402087
Figure 16
the dashboard and press the button on the front Air Cleaner
TIME: 0 hr CHANGE: 2000hr
of the dashboard. A window for resetting/changing REMAIN: 2000hr 0 %
Air Cleaner
TIME:
Fuel Filter
0 hr CHANGE: 2000hr
REMAIN: 2000hr 0 %
Return Filter
TIME: 41 hr CHANGE: 1400hr
REMAIN: 1359hr 2 %
EX1301407
Figure 18
Air Cleaner
Reset Operation
TIME: 0 hr
Hour?
CHANGE: 2000hr
REMAIN: 2000hr 0 %
Return Filter
TIME: 41 hr CHANGE: 1400hr
REMAIN: 1359hr 2 %
EX1301408
Figure 19
Filter/Oil Information
Fuel Filter
TIME: 40hr CHANGE: 2000hr
REMAIN: 1960hr 2 %
Air Cleaner
TIME:
Fuel Filter
0 hr CHANGE: 2000hr
CHANGE:
REMAIN: 2000hr 2000 hr 0 %
Return Filter
TIME: 41 hr CHANGE: 1400hr
REMAIN: 1359hr 2 %
EX1301409
Figure 20
Air Cleaner
Change Period?
After the exchange period change screen pops up,
TIME: 0 hrCHANGE: 2000hr
REMAIN: 2000hr 0 %
press the button on the front of the dashboard Engine Oil Filter
\HV QR
TIME: 0 hr CHANGE: 100hr
and the exchange time will start flashing. REMAIN: 100hr 0 %
Return Filter
Next, change the exchange period using the and TIME: 41 hr
REMAIN: 1359hr
CHANGE: 1400hr
2 %
buttons on the front of the dashboard.
EX1301410
With the replacement period change being
Figure 21
completed, press the button to create a pop-up
window to select the period change.
Use the and buttons to locate it at YES. Then,
press the button to change the replacement
period.
Use the and buttons to locate it at NO. Then,
press the button to allow the pop-up window to
disappear without the replacement period not being
changed.
Replacement Period
Kind Minimum Available Change Value By
Basic Setup Value
Setup Value Step
Fuel Filter 500 100 50
Air Cleaner 2,000 1,000 50
Engine Oil Filter 500 100 50
Return Filter 1,000 100 50
Pilot Filter 500 100 50
Engine Oil 500 100 50
Hydraulic Oil 4,000 1,000 50
Coolant Water 2,000 1,000 50
Symbol Description
Icon
EX1300858
Figure 22
F
E period starts!
Replacement
C E F C
rpm
S USB
EX1402088
Figure 23
WARNING
F
E period is exceeded!
Replacement
C E F C
rpm
C. Machine Information
PM
This is used to check the machine name, engine type Machine State
and attachment options.
Monitoring
At the machine state, if the cursor is placed on the
Filter/Oil Information
machine information, press the button to access
the machine information screen. Machine Information
EX1402090
Figure 25
Machine Information
Engine
EX1402091
Figure 26
S USB
EX1402100
Figure 27
Attachment Setting
Camera Setting
S USB
EX1402092
Figure 28
S USB
EX1402093
Figure 29
EX1402095
Figure 31
screen.
If the system is set up as the owner's password
S USB
EX1402096
locked, access the attachment setting list screen by
using owner's password input screen. Figure 32
3 4 5 6 7 8 9 : ; <
Enter Owner Password
EX1301416
Figure 33
EX1402097
Figure 34
On the attachment setting list screen, when cursor is 5. 1800 rpm 95 lpm 250 bar
up relevant items.
User Setting Max Flow 78 osp
The cursor movement order goes like this: 0 .
53 453
1) One Way Setting
Attachment Use Max E/G Limit Max EX1402101
Flow Min Flow User Setting Max Flow Figure 36
2) Two-way Setting
Attachment Use Max E/G Limit Max
Flow Min Flow User Setting Max Flow
Attachment Use
One Way Setting 1
The attachment use is designed to determine Hqdeohg Button Type
Attachment Use Qrw#Xvh
whether relevant attachments are used or not. Max E/G Limit 5333 usp Max Press(ATT) Qrw#Xvh
If set up as enable, the relevant attachment can be Max Flow(Pump) 573 osp Max Flow(ATT) 453 osp
2 Pump Option Qrw#Xvh Min Flow(ATT)
used. Currently Selected Item! 53 osp
If set up as disable, the relevant attachment cannot User Setting Max Flow 78 osp
be used. 0
63 673
.
S USB
EX1402103
Figure 38
No 2 Camera
Press the ESC button to return to the previous
screen. No 3 Camera
S USB
EX1402104
Figure 39
camera.
On Off
Normal Mirror
EX1301421
Figure 40
EX1301422
Figure 41
EX1402105
Press the ESC button to return to previous screen.
Figure 42
A. Password Setting
PM
Password Setting Gauge Panel Configuration
An owner passwords can be set. Password Setting
S USB
EX1501517
Figure 43
1) Password entry
Owner Password
When the password entry screen appears, use
the keypad to enter the password and move to
the settings screen.
The default password is "1111".
How to enter the password 3 4 5 6 7 8 9 : ; <
Use the and buttons to select digits from 0 Enter Owner Password
to 9 below, and press the button to input the
password.
EX1301416
If the password is input incorrectly, use the
Figure 44
button on the lower right to delete the input
password.
Owner Password
IMPORTANT
If the password is input incorrectly three
times in a row, you will be redirected to the Password Error!
main screen and the system will not start for
the next 10 minutes. 3 4 5 6 7 8 9 : ; <
Enter Owner Password
EX1301433
Figure 45
Unlocked
Engine Startup
1 Minute
5 Minute
Password Change
Figure 46 EX1402107
Password change
Owner Password Change
To change the owner password, select
password change with the keypad.
3 4 5 6 7 8 9 : ; <
Enter Password
EX1301435
Figure 47
Locked
Unlocked
Engine Startup
Password Set
1 Minute
5 Minute
Password Change
EX1402108
Figure 48
S USB
EX1402109
Figure 50
S USB
EX1402194
Figure 51
80%.
80 %
Press the ESC button to return to the previous
screen. C
E F
C
EX1501518
Figure 52
S USB
EX1402110
Figure 53
EX1404851
Figure 54
S USB
EX1404973
Figure 55
E F
C C
rpm
S PLAY
EX1404974
Figure 56
EX1402182
Figure 57
S
EX1404975
Figure 58
D. Time Setting
PM
On the Gauge Panel configuration screen, when Gauge Panel Configuration
cursor is placed on time setting, press the button
Password Setting
to access the time setting.
Brightness Setting
Use the and buttons and locate the cursor at a Default Screen Setting
S USB
EX1402106
Figure 59
When the time setting is completed, locate cursor to DATE 2014 / 10 / 29 SET
S USB
EX1402112
Figure 61
EX1301448
Figure 62
P Pilot Filter
rpm
S USB
EX1402113
Figure 63
F. Unit Setting
PM
On the Gauge Panel configuration screen, when Gauge Panel Configuration
cursor is placed on unit setting, press the button
Brightness Setting
to access the unit setting.
Default Power Mode Setting
Time Setting
Service Phone Number Setting
Unit Setting
S USB
EX1402114
Figure 64
Temperature: °C
Pressure edu nji2 䶫 svl PSd
Pressure: bar
Flux osp jsp
Flow rate: lpm
Speed np2k psk
Speed: km/h
EX1301449
Figure 65
Entering/Accessing Menus
When normal mode screen is displayed, if auto idle selector
button (1, Figure 66), up arrow button (2, Figure 66) and camera
mode selector button (3, Figure 66) are pressed simultaneously
for more than 3 seconds, normal mode screen (Figure 67) will AM
E F
C C
rpm
S USB
1 2 3
EX1501516
Figure 66
E F
C C
rpm
WE1400701
Figure 67
S USB
EX1501519
Figure 68
Exiting/Escaping Menus
1. If the ESC button is pressed the special menu screen will
be returned to the normal mode screen.
2. If this special menu is "ON" without any activity, for more
than 20 seconds, it will return to the normal mode screen.
3. After the turning starter switch to "OFF" position, turn it
back to "ON" position, and the normal mode screen
displayed once again.
EX1501520
Figure 69
Monitoring
PM
1. Entering Submenus: When cursor is located on Monitoring
"Monitoring" of special menu screen, press the button
Machine Analog
and the "Monitoring" will be displayed.
Machine Digital
2. Exiting Submenus: If the ESC button is pressed display will User Selection Signal
be turned to previous screen.
S USB
EX1501521
Figure 70
Submenu Selections
EX1501522
Figure 71
Machine Digital
Preheating (Mechanical)
Start up Switch
Pressure Switch-Py
Pressure Switch-Px
Engine Oil Pressure Switch
Relief Pressure S/V
High Speed S/V
Starter Relay
EX1501523
Figure 72
S USB
EX1501524
Figure 73
S USB
EX1501578
Figure 74
0
1 19 Sec
EX1301616
Figure 75
The maximum limit of the graph data setting is 7. Rear Pump Press.
Boom Cylinder Press.
Px Pressure You can select up to 7
Py Pressure items!
Alternator Voltage
Battery Voltage
Engine Dial Volt.
EX1301617
Figure 76
S USB
EX1501579
Figure 77
S USB
EX1501580
Figure 78
FMI Description
0 Data Valid but Above Normal Operational Range - Most Severe Level
1 Data Valid but Below Normal Operational Range - Most Severe Level
2 Data Erratic, Intermittent or Incorrect
3 Voltage Above Normal, or Shorted to High Source
4 Voltage Below Normal, or Shorted to Low Source
5 Current Below Normal or Open Circuit
6 Current Above Normal or Grounded Circuit
7 Mechanical System Not Responding or Out of Adjustment
8 Abnormal Frequency or Pulse Width or Period
9 Abnormal Update Rate
10 Abnormal Rate of Change
11 Root Cause Not Known
12 Bad Intelligent Device or Component
13 Out of Calibration
14 Special Instructions
15 Data Valid but Above Normal Operating Range - Least Severe Level
16 Data Valid but Above Normal Operating Range - Moderately Severe Level
17 Data Valid but Below Normal Operating Range - Least Severe Level
18 Data Valid but Below Normal Operating Range - Moderately Severe Level
19 Received Network Data in Error
20 Data Drifted High
21 Data Drifted Low
31 Condition Exists
S USB
EX1501581
Figure 81
EX1501527
Figure 82
WE1400760
Figure 83
EX1501528
Figure 84
S USB
EX1501529
Figure 85
Q Q
3 4 5 6 7 8 9 : ; <
Enter Service Password
EX1301634
Figure 86
Option Setting
Program Update
Machine Information Delete
Version Information
S USB
EX1501530
Figure 87
WE1400760
Figure 88
S USB
EX1501531
Figure 89
2. Option Setting
Option Setting
• Attachment Option
When a cursor is located in check box of one-way or Attachment Option One Way Two Way
two-way, press the button on panel and then, the
check box light turns "ON". Two Pump Option Not Use
EX1501550
Figure 90
3. Program Update
Entering Submenus: When a cursor is located in "Program Machine Configuration
Update" of special menu screen (Figure 91) press the Option Setting
button on panel and "Program Update Screen" will be Program Update
displayed (Figure 92).
Machine Information Delete
Version Information
S USB
EX1501551
Figure 91
Program Update
WE1500394
Figure 92
EX1501553
Figure 94
5. Version Information
Entering Submenus: When a cursor is located in "Version Machine Configuration
Information" of special menu screen (Figure 95) press the
Option Setting
button on panel and "Version Information Screen" will
Program Update
be displayed (Figure 96).
Machine Information Delete
Version Information
S USB
EX1501554
Figure 95
Version Information
EX1501555
Figure 96