1- Estimation and Standard Specifications for Buildings 2015.
2- Guidelines for Detailing of Reinforcement in Concrete Structures 2016.
3- Autodesk Robot Structural Analysis and Design 2017.
1|Page
Industrial and Warehouse Steel Structure Structural Drawing
C Perforce
ألسباب مختلفة ،يعتبر الفوالذ مادة البناء المثالية للمستودعات وورش العمل والمباني
الصناعية األخرى .هناك مزايا عديدة لمباني المستودعات الصناعية .باإلضافة إلى اقتصادية
ودائمة .تو فر مباني الهياكل الفوالذية أبسط الحلول لتصميمات المباني التي تتطلب مساحات
مفتوحة كبيرة ،مع توفير مرونة كبيرة في التصميم.
لهذه األسباب ،تشكل مواد البناء الفوالذية اآلن ٪71من المباني التجارية و ٪95من المباني
انتشارا في هذا القرن ،وغالبًا ما يُنظر
ً الصناعية .أصبح الفوالذ اإلنشائي أحد أكثر مواد البناء
إليه على أنه عنصر مهم للغاية في المباني والمساكن الحديثة .وفقًا لجمعية الصلب العالمية ،تم
إنتاج أكثر من 1600مليون طن في عام ، 2016بزيادة 197مليون طن عن العام السابق .أصبح
قابالً للتطبيق ألي نوع من المشاريع ويقدم العديد من الفوائد ،والتي تعتمد عليها العديد من خطط
البناء من أجل السالمة الهيكلية.
س ّهل التبني الواسع للفوالذ (العثور عليه) ،سواء على شكل سبيكة خام أو مكونات مسبقة الصنع.
غالبًا ما يتم بيع األجزاء المصنعة عالنية من قبل الموردين (حيث تبيع العديد من المصانع محليًا
وخارجيًا) ،مما يسمح بشراء المقاطع الحديدية المعرفة من ناحية االبعاد القياسية واالنواع مباشرة ً
من االسواق لكافة الدول .بفضل هذا ،يمكن للشركات العمل بموجب مواعيد نهائية أكثر صرامة
والوصول إلى إمدادات من قطع الصلب في أي مكان في العالم.
يمكن طلب األجزاء الفوالذية بمجرد االتفاق على الخطة المعمارية ،مما يوفر الوقت الذي
سيقضي في انتظار وصولهم إلى الموقع .يوفر هذا وقتًا إضافيًا للتحقق من القياسات والعثور على
التخزين المناسب ،وهي المشكالت التي قد تؤخر عادة ً اإلنشاء لعدة ساعات.
2|Page
Industrial and Warehouse Steel Structure Structural Drawing
Picture1: Largest Abandoned Factory in the World: The Packard Factory, Detroit
3|Page
Industrial and Warehouse Steel Structure Structural Drawing
C أدى ذلك إلى إدخال أول مركبة موجهة آلية( أو ) AGVsفي الخمسينيات من القرن الماضي مصممة لتحمل
األحمال الثقيلة في المصانع والمستودعات .كانت في األساس شاحنة سحب ،لكنها لم تتطلب سائقًا أو نظام سكة
ً
مجاال مغناطيسيًا .جعل ثابتة .لقد تحركت بدالً من ذلك باتباع مسار األسالك المضمنة في األرضية التي تولد
نقل المواد الثقيلة على طول مسار محدد من AGVكحصان للجر لقد كان عمال ال يقدر بثمن يتولى المهام
المتكررة والخطيرة في كثير من األحيان ،مما يسمح للعمال بالتركيز على عمل أكثر تفصيالً أو تعقيدًا .وتم
شحن ثمار هذا العمل ،األجهزة أو األلعاب أو األجهزة اإللكترونية المنتجة ،إلى المستودعات في المدن
والبلدات في جميع أنحاء البالد وجميع أنحاء العالم.
منتصف القرن الحديث :المستودعات تكبر
لقرون ،كان وضع جميع أنواع العناصر في المستودعات يتم بواسطة األشخاص .بالتأكيد ،غالبًا ما كان هناك
نوع من األجهزة اليدوية أو الميكانيكية للمساعدة (شاحنة يدوية ،عربة آلية أو مصعد) ،ولكن كانت مهمة
العمال نقل المخزون إلى المستودع للتخزين ،واستعادته لشحنه إلى تجار التجزئة أو مباشرة للعمالء .لقد كان
وخطيرا في كثير من األحيان .اآلالت ،بالطبع ،حسنت األشياء ،لكن
ً عمال يكسر الظهر ويستغرق وقتًا طويالً
ً
تلك اآلالت تتطلب من الناس تشغيلها.
لكن في الستينيات تغير كل شيء.
شهد ذلك العقد إدخال أول أنظمة التخزين واالسترجاع المؤتمتة أو) ، ) AS / RSوالتي كانت أنظمة يتحكم
فيها الكمبيوتر وتخزن وتسترجع العناصر في المستودعات ومراكز التوزيع .صممت اإلصدارات األحدث
للتعامل مع األحمال الكبيرة على المنصات ،واستوعبت العناصر األصغر .كانت أنظمة التخزين واالسترجاع
اآللية (وما زالت) أنظمة معقدة ومكلفة للغاية ،وتتطلب عادة ً إما تغييرات ضخمة في البنية التحتية أو مرافق
جديدة تما ًما الستيعابها ،لكنها بشرت في فجر أتمتة المستودعات كما نعرفها.
وبعد ذلك ،تغير كل شيء مرة أخرى.
Picture 2: Old
brown warehouse
with sheet metal
.cladding with
street lights.
4|Page
Industrial and Warehouse Steel Structure Structural Drawing
تحتوي مجموعة الرسومات الهيكلية على مجموعات فرعية مختلفة :المالحظات العامة والمخططات
واالرتفاعات واألقسام والتفاصيل.
المالحظات العامة هي جزء من الرسومات اإلنشائية وهي تغطي الرموز المستخدمة في التصميم واللوائح
الداخلية للمبنى .عادة ال توجد تفاصيل عن هذه الرسومات .توفر المالحظات الهيكلية معلومات تتعلق بخصائص
المواد العامة (درجة الصلب أو الخشب ،قوة الخرسانة ،إلخ) أو متطلبات البناء (ضغط التربة ،إجراءات
ضا معلومات حول معايير التصميم (الجاذبية والزلزال وتحميل اللحام ،إلخ) .توفر المالحظات الهيكلية أي ً
الرياح).
توضح رسومات المخطط اإلنشائي األساس واألرضية وخطة السقف للمبنى .توفر هذه الخطط معلومات مثل
حجم وموقع العناصر الهيكلية الموجودة في الخطط المعنية.
تظهر االرتفاعات الجدران الخارجية للمبنى أو الهيكل .في رسومات االرتفاع ،يمكنك العثور على ارتفاع
المبنى (ارتفاعات األرضيات والسقف) والخصائص الهيكلية للعناصر الموجودة في الجدران والتي ال يمكن
رؤيتها في رسومات التخطيط.
تتم اإلشارة إلى مخطط األقسام في الرسومات االنشائية عرض تفاصيل دقيقة باالبعاد او مقياس رسم معتمد
وتوفر معلومات حول العناصر التي ال يمكن رؤيتها في الرسومات االنشائية .عادة ً ما يتم قطع المقاطع من
خالل الجدران أو العناصر الهيكلية غير المعتادة ويجب على ال ُمنشئ أن يكون على دراية.
توفر الرسومات التفصيلية معلومات خاصة حول كيفية إنشاء العناصر الهيكلية أو توصيلها .يمكن أن تكون
التفاصيل مرجعية في الخطط واالرتفاعات واألقسام.
5|Page
Industrial and Warehouse Steel Structure Structural Drawing
في صناعة البناء اليوم ،قبل أن يتم بناء أي شيء ،كان يتم الحلم به ورسمه وتخطيطه على شكل
مخططات .هذه الوثائق هي حقًا أساس أي مشروع بناء ولكنها موجودة منذ بعض الوقت اآلن .إذن ،من أين
ن شأت المخططات وأين تتطور اليوم؟ من بداية رسومات العصور الوسطى إلى التوثيق الرقمي الذي يجتاح
صناعة البناء اليوم ،سنستكشف أدناه كيف تطور تاريخ المخططات على مر القرون وكذلك إلى أين يتجه
مستقبل مستندات التصميم الهامة هذه.
قبل أن تتطور المخططات إلى شكلها الحديث وشكلها والغرض منها ،يبدو أن الرسومات من العصور الوسطى
هي أقدم تشكيالتها .تعد خطة سانت غال واحدة من أقدم الخطط المعمارية المعروفة الباقية .يعتبر بعض
المؤرخين أن هذا الرسم في القرن التاسع هو البداية األولى لتاريخ المخططات .في ظروف غامضة ،لم يتم
بناء الدير الموضح في الرسم .لذلك ،تستخدم مجموعة في ألمانيا هذا الرسم ،جنبًا إلى جنب مع أدوات وتقنيات
الفترة ،لمعرفة المزيد عن تاريخ العمارة.
تبدو الوثائق التي ظهرت من عصر النهضة أشبه بمخططات حديثة أكثر من تلك التي تعود إلى العصور
الوسطى .في الواقع ،استخدم المهندس المعماري والمهندس فيليبو برونليسكي حجرة الكاميرا لنسخ التفاصيل
المعمارية من اآلثار الكالسيكية التي ألهمت عمله .اليوم ،يعتبر( ) Brunelleschiليكون والد التاريخ الحديث
للمخططات .جلب مهندسو عصر النهضة الرسم المعماري كما نعرفه إلى الوجود ،بدقة وبدقة إعادة إنتاج
تفاصيل الهيكل عبر أدوات القياس والمنظور .في ذلك الوقت ،كانت هذه مهمة تستغرق وقتًا طويالً ومتخصصة
،وغالبًا ما يقوم بها رسامون متخصصون.
6|Page
Industrial and Warehouse Steel Structure Structural Drawing
C
Picture 4: drafting men at work
حصلت هذه الوثائق في الواقع على عالمتها التجارية الزرقاء في عام 1842عندما اكتشف جون هيرشل عملية
السيانوتايب .اعتمد الفنانون والعلماء بسرعة هذه الطريقة الجديدة إلعادة إنتاج المالحظات بكفاءة وبتكلفة أقل
من األساليب السابقة المتاحة .كان الحفاظ على صورة ظلية األوراق والسراخس والعينات النباتية األخرى
أسهل من أي وقت مضى.
باستخدام عملية السيانوتايب ،تم عمل رسم معماري على ورق شبه شفاف ،ثم تم وزنه ألسفل فوق ورقة أو
قطعة قماش مطلية بمزيج كيميائي حساس للضوء من فيري سيانيد البوتاسيوم وسيترات األمونيوم الحديديك.
عرضت الوثيقة للضوء .أصبحت األجزاء المكشوفة من الرسم (الخلفية) زرقاء ،بينمافي المراحل األخيرة ُ ،
منعت خطوط الرسم الورق المطلي من التعرض وبقيت بيضاء.
بينما كان الرسامون ال يزالون ينسخون الرسومات في العصر الحديث ،تطورت مجموعة متنوعة من العمليات
الكيميائية والميكانيكية إلعادة إنتاج الرسومات المعمارية من القرنين التاسع عشر والعشرين .حلت عملية
الديازو محل السيانوتايب كعملية طباعة سائدة لمعظم القرن العشرين .بدالً من الورقة الزرقاء ذات الخطوط
البيضاء ،أنتجت العملية طباعة بيضاء بخطوط زرقاء ،وكانت تُعرف أي ً
ضا باسم الرسم "األزرق" أو "الطباعة
7|Page
Industrial and Warehouse Steel Structure Structural Drawing
C البيضاء" .تستخدم أنواع الديازو عملية كيميائية مماثلة للنمط السيانوتيب .تم عمل رسم على مايلر أو سطح
عا مختلفًا من
شفاف آخر ،ووضعه على ورق مطلي كيميائيًا ،وعرضه .يسرد المعهد األمريكي للحفظ 14نو ً
العمليات إلعادة إنتاج الرسومات التي اكتشفوها مع الحفاظ على مجموعة الرسومات في مكتبة New York
.Botanical Garden
رسومات CAD
شهدت نهاية القرن العشرين تطوير تقنية الصياغة بمساعدة الكمبيوتر ( )CADوعمليات الطباعة كبيرة الحجم
التي جعلت است نساخ نسخ دقيقة متعددة من التصميم األصلي للمهندس أسهل من أي وقت مضى .على الرغم
من أن إنتاج المستندات لم يكن أبدًا بهذه السهولة ،إال أن القدرة على الطباعة على الورق بسهولة كانت بمثابة
كابوس إلدارة المستندات .اآلن ،امتألت المكاتب ببكرات ضخمة من المخططات .على النظام الورقي ،في
كل مرة يتم فيها تنفيذ تغيير في خطة البناء ،يجب استبدال المستندات القديمة .ونتيجة لذلك ،يتم إنشاء استنزاف
كبير للقوى العاملة والموارد ،ناهيك عن إعادة العمل التي ال مفر منها عندما تنزلق مجموعة قديمة عبر
الشقوق.
اليوم ،يعتمد مخطط المستقبل رقميًا .على الرغم من أن صناعة البناء ال تزال قائمة على الورق على نطاق
واسع ،إال أن هذا يتغير بسرعة .اآلن ،مع حلول التحكم في المستندات المستندة إلى مجموعة النظراء ،يتم
توزيع ملفات الرسم الرقمي على الفور من المكتب إلى الميدان .يمكن للمستخدمين تحميل الخطط إلى حلول
البرامج السحابية للبناء ،مثل ، Plan Gridوالمزامنة تلقائيًا لجميع األجهزة اللوحية الفردية للمتعاونين في
المشروع .تحل البرامج التي تتضمن ميزات مثل التحكم التلقائي في اإلصدار محل ما كان يستغرق ساعات من
وقت مهندس المشروع .اآلن ،لم يعد عمال البناء يضيعون وقتهم في فك حزم المخططات يدويًا أو إدخال
المراجعات الورقية فعليًا ورقة تلو األخرى .استفاد جميع أعضاء المشروع من أنظمة إدارة المخططات الرقمية
،من المهندسين المعماريين وفرق التصميم إلى العاملين الميدانيين على األرض .أصبحت مطاردة رؤساء
العمال والمشرفين لتسليمهم نسخة ورقية من آخر التحديثات بسرعة شيئًا من الماضي.
8|Page
Industrial and Warehouse Steel Structure Structural Drawing
C Picture 5:
Blueprint
s on Plan
Grid on a
tablet in
the field
9|Page
Industrial and Warehouse Steel Structure Structural Drawing
عادة ً ما تكون (الجملونات المسماة بإطارات البوابة) عبارة عن هياكل منخفضة االرتفاع ،تتكون من
أعمدة وعوارض أفقية أو مائلة ،متصلة بوصالت مقاومة للعزوم الناتجة عن تاثير االحمال التي تتعرض لها.
يتم توفير مقاومة مناسبة لتاثير االحمال الجانبية والعمودية من خالل صالبة الوصالت وصالبة االنحناء
لألعضاء ،والتي تزداد عن طريق التداخل المناسب أو تعميق أقسام من االعضاء االنشائية .هذا الشكل من بنية
اإلطار المستمر مستقر في مستواه ويوفر امتدادًا واض ًحا ال يعيقه الدعامة .إطارات البوابات شائعة جدًا ،في
الواقع ٪50 ،من الفوالذ اإلنشائي المستخدم في المملكة المتحدة يستخدم في بناء إطار البوابة .إنها فعالة للغاية
لتضمين كميات كبيرة ،وبالتالي فهي تستخدم غالبًا للتطبيقات الصناعية والتخزينية والتجارية وكذلك لألغراض
الزراعية .توضح هذه المقالة التفاصيل الهندسية من المقاطع الداعمة للبنية وخواص المواد االنشائية واألنواع
المختلفة إلطار البوابة واعتبارات التصميم الرئيسية.
بنية جملون إطار البوابة النموذجي
المكونات الرئيسية لمبنى مؤطر بالبوابة
يتألف مبنى إطار البوابة من سلسلة من اإلطارات المستعرضة التي يتم دعمها طوليًا .يتكون العمل الفوالذي
األساسي من أعمدة وعوارض خشبية ،والتي تشكل إطارات البوابات ،والدعامات .يمكن أن يكون اإلطار
سا من األعمدة والعوارض الرئيسية.قو ً
النهائي (إطار الجملون) إما إطار بوابة أو ترتيبًا ُم َّ
تتكون األعمال الفوالذية الثانوية ذات المقياس الخفيف من قضبان جانبية للجدران ومدادة السقف .تدعم األعمال
دورا مه ًما في تقييد األعمال الفوالذية األولية.
ضا ًالفوالذية الثانوية غالف المبنى ،ولكنها تلعب أي ً
تفصل كسوة السقف والجدران المساحة المغلقة عن البيئة الخارجية باإلضافة إلى توفير العزل الحراري
ضا تقييد شفة المدادة أو
والصوتي .يتمثل الدور الهيكلي للكسوة في نقل األحمال إلى أعمال فوالذية ثانوية وأي ً
السكة التي يتم توصيلها بها.
10 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C
Figure (1-2): The main part of the gable (main frame) - bay
يمكن إنشاء العديد من األشكال المختلفة إلطارات البوابة .تقدم أنواع اإلطارات الموضحة أدناه نظرة عامة على
أنواع إنشاء المدخل مع توضيح الميزات النموذجية .توفر هذه المعلومات تفاصيل نموذجية فقط وليس المقصود
منها فرض أي قيود على استخدام أي شكل هيكلي معين.
Pitched roof symmetrical portal frame -1إطار البوابة المتماثل للسقف المائل
تُستخدم المقاطع الحديدية القياسية العالمية عادة ً لبناء هذا النوع من إطار البوابة.
Portal frame with interior mezzanine floor -2إطار بوابة مع طابق نصفي داخلي
يحتوي هذا النوع من إطار البوابة على طابق نصفي يمتد من جانب واحد من جزء المبنى من الطريق الستيعاب
موظفي المكتب أو لتخزين إضافي.
12 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C
يمكن استخدام إطار بوابة منحدرة حيث يلزم ارتفاع واضح كبير في منتصف المسافة ولكن يجب تقليل
ارتفاع العمود الجانبي للمبنى.
ً
أطواال على وجه الخصوص ،فإن إطار بوابة السقف عبارة عن تصنيف يتكون من عوارض مكسورة تتضمن
مختلفة ومنحدرات غير متصلة .الهدف من هذا النوع من الجملونات الرغبة إلى تقليل وزن إطار البوابة القياسية
مع أغراض التصميم عن طريق تغيير أربعة معايير :موضع االلتواء ،ومنحدر قمة األفاريز ،واالمتداد
وارتفاع األعمدة .في هذا العمل ،نقترح بعض اإلرشادات التي يمكن أن تحسن القدرات التنافسية االقتصادية
لتصميمها اإلنشائي .في جميع الحاالت التي سيتم التعامل معها من اجل تصميم كفوء ،يتم وضع مفاصل إطار
البوابة فوق الشكل النظري غير المائل إلى األحمال المنتظمة .هذا يسمح بتقليل لحظة االنحناء وقوة القص ،
مع زيادة القوة المحورية .باإلضافة إلى ذلك ،تتم مقارنة أداء اإلطارات المعلقة والبوابات ذات المنحدرات
النموذجية التي تخضع لنفس شروط الحدود من حيث الكفاءة في استخدام الفوالذ .في الغالبية العظمى من
الحاالت ،تكون أنماط المنحدرات أخف من اإلطارات المنحدرة الشائعة ،وبالتالي فهي أكثر اقتصادا.
13 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C
يتأثر تصميم المباني الصناعية بعدة عوامل .يتم تقديم اإلرشادات العامة التالية لتحديد عوامل التصميم الرئيسية
والفوائد التي يوفرها البناء الفوالذي.
تُصمم المباني الصناعية عمو ًما كمرفقات توفر مساحة وظيفية لألنشطة الداخلية ،والتي قد تتضمن استخدام
الرافعات العلوية أو المعدات المعلقة ( ) overhead cranes or suspended equipmentباإلضافة إلى
توفير مساحة مكتبية أو طابق نصفي ( ) Mezzanine floorsتم تطوير أشكال هيكلية مختلفة على مدار
الثالثين عا ًما الماضية والتي تعمل على تحسين تكلفة الهيكل الفوالذي فيما يتعلق بالمساحة المتوفرة.
ومع ذلك ،في السنوات األخيرة ،تم استخدام أشكال من الهياكل التعبيرية ( ) Expressive Structureفي
التطبيقات المعمارية للمباني الصناعية ،وال سيما الهياكل المعلقة واألنبوبية .تعتبر القاعة المفردة الكبيرة السمة
الرئيسية لمعظم المباني الصناعية.
يوفر بناء ومظهر مبنى صناعي لمهندس التصميم مجموعة واسعة من التكوينات الممكنة من أجل تحقيق األفكار
المعمارية والمتطلبات الوظيفية .بشكل عام ،يحتوي المبنى الصناعي على مساحة أرضية مستطيلة قابلة للتمديد
في اتجاهه الطويل .يجب تنسيق تصميم المبنى مع المتطلبات الوظيفية ومفهوم توفير الطاقة ،بما في ذلك
اإلضاءة.
14 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C تمثل األشكال التالية للمباني الصناعية لمحة عامة عن الحلول المعمارية واإلنشائية الممكنة .تميل قاعات
المعارض ومحطات السكك الحديدية والمطارات والساحات الرياضية إلى أن تكون هياكل خاصة .ومع ذلك ،
تقتصر المشكالت العامة التالية على مخططات الطوابق "القياسية" (.) Standard Floor Plans
يتكون النظام األساسي المستخدم في مبنى صناعي من عمودين وجسور شعاعية .يمكن تعديل هذا التكوين بعدة
طرق باستخدام أنواع مختلفة من التوصيالت بين الجسور واألعمدة وقاعدة العمود .أنواع الهياكل األكثر
استخدا ًما في المباني الصناعية هي إطارات بوابات ذات قواعد أعمدة مفصلية.
توفر إطارات البوابة ثباتًا كافيًا داخل المستوى ،وبالتالي ال تتطلب سوى دعائم ( ) Bracingsلالستقرار
خارج المستوى.
يوضح الشكل 6.2مجموعة متنوعة من اإلطارات الصلبة مع قواعد أعمدة ثابتة (أ) أو مفصلية (ب).
يمكن النظر في قواعد األعمدة الثابتة عند استخدام الرافعات الثقيلة ،ألنها تنحرف بشكل أقل تحت القوى األفقية.
قواعد األعمدة المفصلية لها أساسات أصغر ووصالت أساسية بسيطة .في المثال (ج) ،يقع الهيكل جزئيًا خارج
المبنى ،وبالتالي يجب تصميم التفاصيل المتعلقة بثقب غالف المبنى بعناية .كما أن التفاصيل المعقدة في هذه
ضا معمارية.
ضا أغرا ًاألنواع من الهياكل تخدم أي ً
يوضح الشكل ( 6.2أ) مثاالً على هيكل بدون مدادات ،والتي يتم تقويتها بواسطة حركة الحجاب الحاجز في
السقف والدعامات في الجدران .في الشكل ( 6.2ب) ،يتم استخدام المدادات ،مما يؤدي إلى تصميم بسيط
لكسوة السقف ،مما يقلل من االمتدادات ( ) Purlinsويعمل فقط على دعم األحمال الرأسية .قد يوفر الهيكل
عا عند النظر إليه من الداخل.
مظهرا أكثر إمتا ً
ً الذي ال يحتوي على مدادات
يوضح الشكل ( 6.2ج) دعامات شبكية والتي قد تكون مفيدة لتحقيق مسافات أكبر ،فضالً عن كونها مرغوبة
ألسباب بصرية.
15 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
الشكل يمثل
الفضاءات االقتصادية
النواع المحتملة
الجملونات البسيطة
التالية
Loadings االحمال
17 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C يجب مراعاة اإلجراءات ومجموعات اإلجراءات الموضحة في هذا القسم عند تصميم مبنى صناعي من طابق
واحد باستخدام هيكل فوالذي .ترد األحمال المفروضة والثلجية والرياح في الكود األوروبي(EN 1991-1-
1و 3-1-1-1-1و . )4-1-1991اإلجراءات والمكونات الهيكلية ذات الصلة ويوضح الشكل 7.2مخطط
الحمل النموذجي.
األحمال العمودية
حيثما أمكن ،يجب فحص أوزان الوحدات للمواد مع بيانات الشركات المصنعة .يمكن اعتبار األرقام الواردة
في الجدول 2.2نموذجية لمواد التسقيف المستخدمة في التصميم المسبق لبناء إطار البوابة .يتراوح الوزن
معبرا عنه في منطقة الخطة.
ً الذاتي لإلطار الفوالذي عادة ً من 0.2إلى 0.4كيلو نيوتن /م، 2
حمولة اسمية على كامل مساحة السطح تتراوح بين 0.1و 0.25كيلو نيوتن /متر مربع حسب المخطط اعتمادًا
على استخدام المبنى ،وما إذا كان يتم توفير نظام رش أم ال.
تحدد EN 1991-1-1و 3-القيم المميزة ألنواع مختلفة من األحمال المفروضة على األسطح:
يتم تطبيق حد أدنى للحمل يبلغ 0.6كيلو نيوتن /متر مربع (على المخطط) لمنحدرات األسطح التي تقل عن
30درجة ،حيث ال يُقصد الوصول بخالف التنظيف والصيانة.
حمولة مركزة تبلغ 0.9كيلو نيوتن -سيؤثر ذلك فقط على تصميم األلواح.
حمولة موزعة بشكل موحد بسبب تساقط الثلوج فوق مساحة السطح الكاملة .يمكن اهمالها في المناطق الجنوبية
للعراق.
18 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C تعتمد قيمة الحمولة على موقع المبنى وارتفاعه فوق مستوى سطح البحر .إذا تم استخدام إطارات بوابات متعددة
الفتحات مع منحدرات سقف ،فيجب مراعاة تأثير أحمال الثلج المركزة في الوديان.
حمولة غير موحدة ناتجة عن انجراف الثلج عبر السطح بسبب هبوب الرياح عبر سلسلة التالل من المبنى
وتسبب المزيد من الثلوج على جانب الريح .يتم أخذ هذا في االعتبار فقط للمنحدرات التي تزيد عن 15درجة
وبالتالي لن تنطبق على معظم المباني الصناعية.
نادرا ما يحدد تحميل الرياح حجم األعضاء في إطارات يتم إعطاء إجراءات الرياح بواسطة ً EN 1991‑1‑4.
البوابة أحادية االمتداد منخفضة االرتفاع حيث تكون نسبة االرتفاع :االمتداد أقل من .4 :1لذلك ،تحميل الرياح
يمكن تجاهلها عادة ً للتصميم األولي إلطارات البوابة ،ما لم تكن نسبة االرتفاع إلى االمتداد كبيرة ،أو إذا كان
الضغط الديناميكي مرتفعًا .مشترك
يمكن أن تكون قوى رفع الرياح على الكسوة عالية نسبيًا في زاوية المبنى وعند األفاريز والتالل .في هذه
المناطق ،قد يكون من الضروري تقليل التباعد بين الجسور الشعاعية والقضبان الجانبية.
قبل التصميم التفصيلي للمبنى الصناعي ،من الضروري مراعاة العديد من الجوانب مثل:
األداء الحراري وضيق الهواء البنية التحتية لإلمداد مرونة في االستخدام تحسين الفضاء
العزل الصوتي تكامل الخدمة األداء البيئي سرعة البناء
الجماليات والتأثير البصري السالمة من الحرائق الوصول واألمان توحيد المكونات
توفير الراحة لالشخاص اعتبارات االستدامة نهاية العمر وإعادة االستخدام تنسيق حدائق
اعتبارات االستدامة عامل مهم لديمومة المنشأ على سبيل المثال عند استخدام جملون لصالح حضائر
الدواجن من المهم جدا استخدام مركبات مقاومة لالمونيا لطالء مقاطع الحديد او طالئها بمادة
االيبوكسي.
19 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C توحيد المكونات من المفضل استخدام الحد االدنى للمقاطع الحديدية لالعضاء االنشائية المتماثلة في
طبيعة الخدمة لتقليل تعقيد التفاصيل االنشائية.
نهاية العمر وإعادة االستخدام تعتبر خاصية المنشأ الحديدي في اعادة تفكيكة وتركيبة في مكان مختلف
من اهم خواصه المحببة لذلك دائما مايرغب عن التصميم للوصالت االنشائية استخدام نضام الربط
عن طريق البراغي ( ( bolted connectionsلتسهيل عملية التفكيك والنقل .
الحماية من الحرائق بالنسبة للمباني الصناعية الكبيرة ،قد تلعب حجرة الحريق ً
دورا مه ًما في التصميم
،حتى لو لم يكن هناك مساحة مكتبية داخلية .من أجل منع انتشار الحريق ،يقتصر حجم المقصورة
على قيمة معينة .لذلك يجب توفير جدران النار للفصل ويجب أن تضمن مقاومة الحريق لمدة 60دقيقة
على األقل وغالبًا 90دقيقة .هذا أكثر أهمية إذا تم تخزين البضائع الخطرة في المبنى.
نظرا ألن المكتب مصمم لالستخدام من قبل عدد أكبر من األشخاص ،فإن متطلبات السالمة من ً
الحرائق أكثر صرامة .إذا كانت المكاتب تقع في الطابق العلوي من المبنى ،فستكون هناك حاجة إلى
طرق هروب إضافية (سلم طوارئ ) ويجب مراعاة تدابير مكافحة الحرائق النشطة .يجب منع انتشار
الحريق من حجرة إلى أخرى ،وهو ما يمكن تحقيقه ،على سبيل المثال من خالل (لوح مركب) بين
المكاتب والمساحة الحركة الصناعية.
C . اإلجراءات والمكونات الهيكلية ذات الصلة المباشرة مع االحمال المفترضة للتصميم: 1-2 الجدول رقم
Action Applied to
Self-weight Cladding, purlins, frames, foundation
األساس، اإلطارات، المدادات او الطراحيات، الكسوة
Snow Cladding purlins, frames, foundation
Concentrated snow Cladding, purlins, (frames), foundation
Wind Cladding purlins, frames, foundation
Wind (increase on single element) Cladding, purlins,
fixings
Wind (peak undertow) Cladding, purlins, (fixings)
Thermal actions Envelope, global structure
Service loads Depends roofing, purlins, frames
on specification
أحمال الخدمة اعتمادا على اإلطارات، المدادات او الطراحيات، التسقيف
المواصفات
Crane loads Crane rails, frame
حموالت الرافعة اإلطار، الجسر الحديدي الذي يدعم حركة الجسر الرئيسي للرافعة
Dynamic loads Global (Depends on building use and locality)
structure يعتمد على استخدام المبنى والموقع
Second order effects Wall bracings, columns
(Sway imperfections)
. أوزان نموذجية لمواد التسقيف: 2-2 الجدول رقم
Material Weight (kN/m²) Material Weight (kN/m²)
Steel roof sheeting (single 0.07 - 0.20 Composite panels (40 mm 0.10 - 0.15
skin) – 100 mm thickness)
Aluminum roof sheeting 0.04 Purlins (distributed over 0.03
(single skin) the roof area)
Insulation (boards, per 25 0.07 Steel decking 0.20
mm thickness)
Insulation (glass fiber, per 0.01 Three layers of felt with 0.29
100 mm thickness) chippings
Liner trays (0.4 mm – 0.7 0.04 - 0.07 Tiling (clay or plain 0.60 - 0.80
mm thickness) concrete)
Slates 0.40 / 0.50 Tiling (concrete 0.50 - 0.80
interlocking)
21 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
على نحو متزايد ،تم تصميم المباني الصناعية الكبيرة لالستخدامات المختلطة ،أي في معظم الحاالت يتم
توفير مساحات مكتبية و /أو غرف موظفين متكاملة للموظفين .هناك مواقع مختلفة محتملة لهذه المساحات
واالستخدامات اإلضافية ,كما موضحة في الشكل 8-2ادناه:
بالنسبة للمباني الصناعية من طابق واحد ،إنشاء مساحة منفصلة داخل المبنى وربما ارتفاع طابقين ،مفصولة
بجدران داخلية .في مبنى خارجي متصل مباشرة بالقاعة نفسها.
هذا يؤدي إل ى متطلبات تصميم المفهوم الخاص فيما يتعلق بهيكل الدعم وأداء فيزياء المبنى .إذا كانت منطقة
المكتب تقع في الطابق العلوي من المبنى الصناعي ،فيمكن تصميمها كهيكل منفصل محاط بهيكل المبنى .في
هذه الحالة ،يمكن استخدام أنظمة األرضيات من المباني التجارية ،والتي غالبًا ما تعتمد على العناصر االنشائية
المركبة.
Figure (2-8): Different possible locations for these additional spaces and uses.
22 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C األداء الصوتي خاصة في المباني الصناعية ذات عمليات اإلنتاج كثيفة الضوضاء ،يجب تحقيق فصل صارم
بين وحدة اإلنتاج ومساحات المكتب .قد يتطلب ذلك تدابير خاصة للعزل الصوتي ،اعتمادًا على عمليات اإلنتاج.
بالنسبة للمباني الصناعية ،غالبًا ما يتم تحديد المتطلبات الخاصة لخدمات البناء ،والتي قد تكون ضرورية
لتشغيل اآلالت وخطوط التصنيع .يجب أن يؤخذ تكامل الخدمة في االعتبار في مراحل التخطيط المبكرة .على
وجه الخصوص ،يجب أن يتم تنسيق موضع وحجم مجاري الهواء مع هيكل وأحكام اإلضاءة الطبيعية .يمكن
أن يؤدي استخدام األنظمة الهيكلية ،مثل الحزم الخلوية (الجسور ذات الفتحات )Rafter with opening
في الجمالونات ،إلى تسهيل تكامل الخدمات والمساعدة في تحقيق مظهر متماسك للمبنى.
يمكن أن يكون لتصميم آالت الخدمة والغرف أهمية كبيرة في المباني الصناعية .يمكن أن يوفر مركزية خدمات
المبنى ميزة الصيانة السهلة .يوضح الشكل 8-2الحلول الممكنة المختلفة لتحديد مواقع غرف الخدمة.
تعمل التهوية الطبيعية على تقليل االعتماد على أنظمة تكييف الهواء ،مما يعني بدوره تقليل انبعاثات ثاني
خيارا
ً أكسيد الكربون في المبنى .تعتمد فعالية التهوية الطبيعية على حجم واتجاه المبنى .تعتبر فتحات السقف
شائعًا للتهوية الطبيعية في المباني التي ال تحتوي على فتحات كبيرة بشكل مناسب ،ولكن يجب أن يتم وضعها
بعناية لتحقيق أقصى قدر من األداء .أصبحت أنظمة التهوية الهجينة شائعة اآلن في المباني الصناعية.
يستخدمون تهوية طبيعية في الغالب ،ولكن مع مراوح تعمل ميكانيكيًا لتحسين القدرة على التنبؤ باألداء على
نطاق أوسع من الظروف الجوية.
تستخدم أنظمة االسترداد ) (MHVRالحرارة من الهواء الدافئ الخارج لتسخين الهواء البارد أثناء دخوله
المبنى.
يتم تنفيس الهواء الدافئ من المبنى إلى جا نب الهواء النقي القادم ،مما يسمح بنقل الحرارة من الخارج إلى
الهواء الداخل .على الرغم من أن نقل الحرارة هذا لن يكون ً
فعاال بنسبة ، ٪100إال أن استخدام أنظمة
MHVRيمكن أن يقلل بشكل كبير من كمية الطاقة المطلوبة لتدفئة الهواء النقي إلى مستوى مريح .تشمل
القضايا األخرى التي قد تحتاج إلى النظر في تصميم الخدمات ما يلي:
23 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C التأثير المحتمل لعناصر الحماية الشمسية على تبادل التحكم في الرطوبة -عامل مهم للسيطرة على خزن
المواد االولية في الصناعة او المواد التي تخزن لمدة الهواء.
اشهر .
السيطرة على ضيق الهواء. استخالص الرائحة – عوامل البيئة الصحية.
العزل الصوتي – الضوضاء عامل مهم في اساليب العزل الحراري الفعالة الجواء العراق
المنشاءات الصناعية والخزينة والتي تتعلق بقدرة الصحراوية.
العاملين االداريين ذوي االعمال المكتبية للبقاء في
مكاتبهم للخدمة لفترة اطول .
تعتمد متطلبات إضاءة المباني الصناعية على نوع االستخدام .يسمح مفهوم وترتيب الفتحات لتوفير اإلضاءة
الطبيعية بالتنوع في التصميم المعماري.
تعتبر مصابيح السقف واألسطح الزجاجية ذات الجملونات شائعة ،جنبًا إلى جنب مع األشرطة الضوئية في
الواجهة (الشكل .)9.2يمكن أن تكون فتحات اإلضاءة الطبيعية بمثابة مخارج للدخان والحرارة في حالة نشوب
حريق .يمكن أن يكون لضوء النهار الطبيعي المصمم جيدًا تأثير كبير على انبعاثات الكربون في المبنى .ومع
ذلك ،فإن الكثير من ضوء النهار الطبيعي يمكن أن يؤدي إلى زيادة كبيرة في الطاقة الشمسية في الصيف ،
مما يؤدي إلى ارتفاع درجة الحرارة وزيادة فقدان الحرارة خالل الغالف في الشتاء .إن قرار استخدام ضوء
النهار الطبيعي داخل المبنى ونوع ضوء النهار المحدد لهما آثار مهمة على التصميم العام للمبنى.
24 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
يصف هذا القسم األنظمة الشائعة المستخدمة لهياكل الدعم الرئيسية في المباني الصناعية .تم وصف خصائص
أطر البوابة وكذلك هياكل األعمدة والجسور الشعاعية ،إلى جانب معلومات عن المكونات والتوصيالت
الثانوية.
عادة ً ما تكون مباني إطار البوابة عبارة عن هياكل منخفضة االرتفاع ،تتكون من (أعمدة وعوارض جسور
شعاعية رئيسية وطراحيات) أفقية أو مائلة ،متصلة بوصالت مقاومة للعزوم الناتجة عن االحمال.
يُفضل عمو ًما إطارات البوابة ذات قواعد األعمدة المفصلية ألنها تؤدي إلى أحجام أساس أصغر مقارنة بالقواعد
الثابتة .عالوة على ذلك ،تتطلب األعمدة الثابتة تفاصيل اتصال أكثر تكلفة ،وبالتالي ال يتم استخدامها في
الغالب إال إذا كان ال بد من مقاومة القوى األفقية العالية .ومع ذلك ،فإن األعمدة المثبتة لها عيوب تؤدي إلى
أوزان فوالذية أثقل قليالً بسبب انخفاض صالبة اإلطار للقوى الرأسية واألفقية.
هذا الشكل من هيكل اإلطار الصلب مستقر في مستواه الخاص ويوفر امتدادًا واض ًحا ال يعوقه دعامة .يتم تحقيق
االستقرار من خالل عمل اإلطار الصلب الذي يتم توفيره من خالل االستمرارية في الوصالت ويتم تحقيق ذلك
عادة عن طريق استخدام التدعيم ( ) Haunchعند االعمدة .
يجب توفير االستقرار في معظم الحاالت بواسطة عناصر إضافية ،مثل التصالب والمدادات
(( )Bracing and Purlinsالشكل .(10 .2باستخدام صفائح ملفوفة ،يمكن الحصول على تقوية السقف
ضا أن توفر جدران القص واستخدام
من خالل عمل الحجاب الحاجز المجهد بدون دعامة إضافية .يمكن أي ً
األعمدة ذات النهايات (الثابتة قيودًا) خارج المستوى على إطارات البوابة.
يمكن تصنيف عدد من أنواع الهياكل على نطاق واسع على أنها إطارات بوابة.
المعلومات المقدمة فيما يتعلق باالمتدادات ،وميل السقف ،وما إلى ذلك ،هي نموذجية ألشكال البناء الموضحة.
مترا عادة ً ما تكون المقاطع الفوالذية المستخدمة في هياكل إطار البوابة ذات االمتدادات من ً 12
مترا إلى ً 30
نادرا ما
عبارة عن مقاطع مدلفنة على الساخن ويتم تحديدها في الدرجات S235أو S275أو حتى ً S355.
يكون استخدام الفوالذ عالي القوة اقتصاديًا في الهياكل التي قد تتحكم فيها قابلية الخدمة (أي االنحراف) أو
معايير االستقرار في التصميم.
25 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
26 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
عا للمباني الصناعية هو إطار البوابة المتماثل أحادي المدى ،كما هو موضح أحد أكثر الهياكل شيو ً
سا في مرحلة
في الشكل .3.1ظهرت الخصائص التالية على أنها األكثر اقتصادا ،وبالتالي يمكن اعتبارها أسا ً
التصميم المبكرة:
.3درجة ميالن الجسر الشعاعي الرئيسي ( ) Angle of Rafterسقف بين ° 5و ° 6( ° 10يتم تبنيها
بشكل شائع).
.4تباعد اإلطارات ( ) Bay - Bayبين 5م و 8م (تكون المسافات األكبر المرتبطة بإطارات البوابة
ذات االمتداد األطول).
.5التضخيم االضافي ( )Haunchللجسور الشعاعية عند مفصل العمود مع الجسر( Eave to Rafter
) Kneeوإذا لزم األمر في القمة (.)Apex
يمكن استخدام الجدول 3.1كعامل مساعد للتصميم ( المسبق ) إلطارات البوابة أحادية االمتداد .يؤدي استخدام
التضخيم االضافي ( )Haunchللجسور الشعاعية والقمة على حد سواء إلى تقليل العمق المطلوب للجسور
الحديدية الشعاعية وتحقيق اتصال فعال في هذه النقاط .غالبًا ما يتم قطع الجزء الخلفي من نفس حجم المقطع
الجسر الشعاعي.
الجدول : 1.3المقاطع االولية المفترضة للجملون قبل اجراء الحسابات لتدقيقها.
Required cross section S275 - JR Frame
Roof pitch Eave height
spacing Span m
Rafter Eave angle deg. m
m
IPE 550 IPE 600 5 6 6.0 30.0
IPE 500 IPE 500 5 6 6.0 25
IPE 450 IPE 450 5 6 6.0 20
IPE 360 IPE 360 5 6 5 15
IPE 300 IPE 300 5 6 4 12
27 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C 1-3جملونات ذات شكل إطارات البوابة واستخدام المقاطع الحديدية IPE Sections
تتكون الجسور الشعاعية وأعمدة إطارات البوابة ذات المقطع IPEمن أقسام مدرفلة على شكل ، Iمع نهايات
( الجسور الشعاعية مثقوبة ومثبتة بالمسامير في األعمدة ،كما هو موضح بالتفصيل (ج) من الشكل .1.3
مقطع الحديد للعمود أثقل من مقطع الجسور الشعاعية ) ،بحيث تتبع قوة العارضة النسبية لشكل مخطط عزم
االنحناء تقريبًا أعلى العمود وعبر العارضة .عادة ً ما يتم تصميم اإلطارات بشكل بالستيكي ،وبالتالي فإن
العزوم المشار إليها هي العزوم البالستيكية تحت تحميل الجاذبية ،مع تطوير مفصالت بالستيكية إما في أعلى
العمود أو في العارضة عند الجهة الخلفية وفي العارضة بالقرب من القمة.
مع التخفيض في التحميل المباشر للسقف الذي يلجأ اليه المصممون حاليا بسبب زيادة السيطرة
النوعية الجيدة للمواد والتنفيذ ،ومع عامل تجميع الحمولة األكثر مالءمة للحمل الميت
) ،)Self-weight and Roofing loadsباإلضافة إلى مجموعة الحمل المباشر بالنسبة إلطار بوابة نموذجي
،أصبح اآلن حوالي 65في المائة فقط مما كان عليه في السابق .هذا يعني ،بالطبع ،أنه يمكن استخدام الجسور
ضا أكثر عمقًا نتيجة لذلك ،فقد يكون
الشعاعية األخف وزنا وأقسام العمود ،ولكن إذا تم جعل هذه االمقاطع أي ً
انحراف اإلطار أكبر مما كان عليه في التحميل الثقيل.
عندما يكون االنحراف حر ًجا في ظل التحميل القديم ،يمكن في مثل هذه الحالة عدم االستفادة الكاملة من تقليل
الحمل وسيكون معامل البالستيك المطلوب أكثر بكثير من 65في المائة من القيمة القديمة.
تنطبق التعليقات المذكورة أعاله على التحميل الحي باإلضافة إلى التحميل المباشر ،والذي عادة ما يكون عبارة
عن تركيبة الحمولة التي تملي اختيار أحجام العمود والجسور الشعاعية من وجهة نظر القوة .ومع ذلك ،غالبًا
ما يكون حمل الرياح الميت زائد هو التركيبة التي تحكم من وجهة نظر االنحراف الجانبي ( ) Side Sway
وقد يكون من الضروري زيادة أحجام األعضاء لتحقيق االنحرافات ضمن الحدود المسموح بها.
لألسباب المذكورة أعاله ،من المرجح أن يتم تصميم إطارات البوابة بشكل مرن Elastic Designأكثر من
التصميم البالستيكي Plastic Designفي المستقبل .في أي حال ،من الضروري إجراء تحليل مرن للتحقق
من االنحرافات.
سنعتمد في التصميم االنشائي على استخدام البرامجيات الكفوءة والتي توفر الجهد والوقت وتحقيق الدقة االعلى
وهذا الطريق الهندسي يجب ان يتوجه اليه المهندسين اليوم بشكل كامل ويوفر نظرة دقيقة للمنشا اثناء عملية
التصميم الن المنشا يتجسد امامك من الناحية الشكل الهندسي وارتباط االعضاء ببعضها اثناء العمل اضافة الى
انه يوفر ميزة التعديل بسهولة ونقل النتائج الى ملفات يمكن ان تدقق من جهات اخرى ومصادقتها الستكمال
العمل فنيا واداريا.
سنعتمد في التصميم على المقاطع االوربية للحديد وهي متوفرة في السوق المحلية ومناسبة من الناحية
االقتصادية وتحقق المتطلبات الفيزيائية المطلوبة بشدة والمناسبة الجواء البلدان الحارة ومنها العراق.
28 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
29 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
30 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C الشكل ( )1,2-3يمثالن التخطيط االولي المقترح وتوزيع االعمدة وكذلك المقاطع المقترحة اعتمادا على الجدول
( ) 3.1كمقترح مسبق سيتم تدقيقها عند اجراء التحليل االنشائي .سيتم استخدام برنامج االوتودسك روبوت
االحترافي في تحليل وتصميم الجملون للوصول الى المقاطع التي ستحقق ثالثة عموامل مهمة هي (االمان
والوظيفية واالقتصادية القصوى) وسيتم استخدام التحليل المرن .
Figure (3-3): Autodesk Robot – Geometry of Portal Frame with Euro Sections
31 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C : واالن لنضع االحمال المفترضة وحسب الجدول الذي قدمناه في الفصل الثاني
Figure (3-4): Autodesk Robot – Service Loads on Roofing Z-dir. = -0.25 KN/m2
Figure (3-5): Autodesk Robot – Imposed Loads on Roofing Z-dir. = -0.60 KN/m2
32 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
الحمل: ) لالحمال ونستخدم نوعين من تكامل الحمل وهماLoads Combinations ( بعدها اجراء
)ULS and SLS Loads Comb.( . االقصى والحمل الخدمي
Combinations
Combination Case
Combinations Name Analysis type Definition
type nature
5 (C) COMB1 Linear Combination ULS dead (1+2+3)*1.20+4*1.35
6 (C) COMB2 Linear Combination SLS dead (1+2+3+4)*1.00
33 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
34 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C سنحتاج هذا الحمل في تصميم. كيلونيوتن49.06 ) ومقدارهA-7( اعلى حمل على العمود ذو المحاور
.قواعد االعمدة الخرسانية
S S
S max S min S min(My) S min(Mz)
max(My) max(Mz) Fx/Ax (MPa)
(MPa) (MPa) (MPa) (MPa)
(MPa) (MPa)
bracing simple ( وهو يمثل242 ميكاباسكال في العضو االنشائي رقم269.80 الحظ ان اعلى اجهاد هو
لذلك يفضل, ميكاباسكال المسموح به275 ) وقريب جدا في االجهاد منL75x75x6 mm( ) وبمقطعbar
. )L75x75x8 mm( استبداله بمقطع
35 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
و7.2 الفقرتان، EN 1993-1-1 وفقًا لـ.Eurocode 1993-1-1 لم يتم تعيين حدود انحراف محددة في
قد. يجب تحديد حدود االنحراف لكل مشروع واالتفاق عليها مع العميل، ]2[ A1.4 الملحق- EN 1990
عندما يتم تحديد الحدود يجب الوفاء. حدودًا للتطبيق في البلدان الفرديةEN 1993-1-1 يحدد الملحق الوطني لـ
. قد يكون ما يلي مفيدًا عند تحديد حدود االنحراف ذات الصلة، في حالة عدم تحديد الحدود.بها
: تحديد االنحراف األفقي3.2 الجدول
Horizontal
Structure Comments
Deflection limits
Portal frames without gantry cranes, Recommended in
with walls of : industry guidance
Steel sheeting
H/100
deflection at top of column
Fiber reinforced sheeting
H/150
deflection at top of column
Brickwork يتطابق هذا الشرط مع
H/300
deflection at top of column 1 المثال رقم
Hollow concrete brickwork
H/200
deflection at top of column
Precast concrete units
H/200
deflection at top of column
Brickwork
- deflection at top of column
((H2+B2)/660)1/2
Differential deflection between two
consecutive portal frames
Precast concrete units
- deflection at top of column
((H2+B2)/330)1/2
Differential defection between two
consecutive portal frames
36 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C من نتائج المثال التصميمي فان مقدار االزاحة الجانبية للعمود باالتجاه االفقي بسبب حمل الرياح وتقريبا
%80من االحمال المفروضة هو 4.9ملم ولتدقيق ومقبولية هذه القيمة مع محددات االزاحات حسب الجدول
رقم , 3.2لذلك:
االزاحة االفقية في اعلى االعمدة مقبولة الغراض الخدمة وحماية الجدران الطابوقية من التشقق.
Vertical
Comments Structure
Deflection limits
Recommended in
Roofs with access for maintenance L/200
industry guidance
Roofs accessible to personnel other than
L/360
for maintenance
مقدار االزاحة الراسية في منطقة القمة باالتجاه العمودي بسبب االحمال المفروضة هو 31.8ملم ولتدقيق
مقبولية هذه القيمة مع محددات االزاحات حسب الجدول رقم , 3.3لذلك:
ولتدقيقه الغراض نوعية تغليف السقوف فان االزاحات العمودية فهي تعتمد على المحددات التالية:
Vertical
Comments Structure
Deflection limits
Portal frames without gantry cranes, with Recommended in
rafter slopes ≥3o industry guidance
Differential deflection relative to
adjacent frame
B/100
- metal sheeting and fiber reinforced
sheeting
- felted metal decking on purlins B/100
37 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
حالة الحد االقصى( :حالة تكوين بركة مياه ناتجة عن االمطار على السقوف ذات الميالن المنخفض)
عندما يكون منحدر السقف أقل من ، ٪5يجب إجراء حسابات إضافية للتحقق من عدم إمكانية حدوث االنهيار
بسبب وزن الماء:
إما مجمعة في أحواض يمكن أن تتشكل بسبب انحراف األعضاء اإلنشائية أو مواد التسقيف ،أو احتفظت بها
الثلوج.
Ultimate Limit States يجب أن تستند هذه الفحوصات اإلضافية إلى المجموعات الموجودة في
قد يقلل التحريف المسبق للحزم من احتمالية تجمع مياه األمطار في البرك ،بشرط أن تكون منافذ مياه األمطار
في موقع مناسب.
حالة التدقيق االضافية لبيان اقتصادية المقاطع لالعمدة والجسور الشعاعية تستخدم فيها خاصية ( Member
)Design and verificationsفي برنامج االوتودسك روبوت .
38 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
بعد ان تم تدقيق المقاطع الرئيسية واالطمئنان لسالمتها يكون الشكل االولي هو كاالتي:
39 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
عادة ً ما يخضع تصميم إطار البوابة للتحقق من األعضاء في .ULSعلى الرغم من أهمية فحوصات SLS
،إال أن اإلطارات التقليدية تكون بشكل عام صلبة بدرجة كافية لتلبية حدود انحراف .SLSيمكن تحقيق
االقتصاد في اإلطار العام باستخدام تحليل البالستيك ؛ يتطلب هذا أقسا ًما من الفئة 1أو 2في جميع األنحاء
والفئة ( 1تعني المنطقة القريبة من االتصال لمنطقة التقاء الجسر الشعاعي مع العمود )Haunchحيث
يوجد مفصل يُتوقع تدويره.
Figure (3-9): Section of Class 1 and Class 2 - Portal frame bending moments,
gravity actions
كما هو مبين في الشكل ( ، )9-3تخضع الجسور الشعاعية لعزوم انحناء عالية في مستوى اإلطار ،والتي
تختلف من عزم المسمى "هوجينج " hoggingقصوى عند التقاطع مع العمود إلى أدنى لحظة ترهل بالقرب
من القمة .كما أنها تخضع للضغط الكلي من حركة اإلطار .ال تخضع ألي من عزم محور ثانوي .على الرغم
ضا للحد من تأثيرات الهندسة المشوهة والحد من من أهمية مقاومة العضو ،إال أن صالبة اإلطار ضرورية أي ً
انحرافات SLS.لهذه األسباب ،ال يتم استخدام األعضاء عالية القوة بشكل عام في إطارات البوابة ،ولكن يتم
40 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C استخدام درجات الفوالذ األقل مع القصور الذاتي العالي .يتم تحقيق التصميم األمثل لعوارض إطار البوابة
بشكل عام باستخدام:
oمقطع عرضي بنسبة عالية من Iyyإلى Izzيتوافق مع متطلبات الفئة 1أو الفئة 2تحت ضغط االنحناء
والمحور الرئيسي المشترك.
oجزء يمتد من العمود لحوالي ٪10من امتداد اإلطار .هذا يعني عمو ًما أن الحد األقصى لعزم الركود
والترهل في طول الجسور الشعاعية.
لذلك ستكون منطقة الترخيم لمقاومة العزوم القصوى باستخدام مقاطع اضافية تزيد من عمق الجسر الشعاعي
بامتداد من منطقة اتصال الجسر الشعاعي وتقل بالعمق الى درجة العودة الى العمق االساسي للجسر الشعاعي
باستخدام الترتيب االنشائي التالي:
غالبًا ما تكون ألواح التقوية ( )Stiffener Plateللعمود مطلوبة لتقوية الويب و /أو الفلنجات ضد قوة الشد
أو الضغط في حواف الورك ،ولكن يمكن االستغناء عنها في الجملونات ذات الفضاء االصغر أو عندما يكون
قسم العمود في منطقة االرتباط ممتلئًا بدرجة كافية.
يجب أن تكون البراغي المستخدمة في الوصالت من الدرجة ( S 8.8نوع قبضة االحتكاك friction-grip
)typeبسبب قوى الت وتر العالي التي يسببها ،ولكن ال تحتاج إلى عزم كامل لنقل قوى القص في قبضة
االحتكاك .ومع ذلك ،يجب إحكام ربطها جيدًا لضمان الحمل المناسب بين أسطح التالمس.
42 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C يجب ترك سماحية مقدارها 2ملم لقطر للفتحة المخصصة لكل برغي خاص بالتثبيت للوصالت .ال تؤخذ قوى
السحب ( )Prying Forceفي االعتبار ألنه تم اعتماد نموذج الصفيحة "السميكة" .في حالة استخدام صفيحة
( )end connection plateاقل من 12ملم في السمك فيكون من المطلوب حتما اضافة صفائح تقوية
( ) stiffener plateلتدعيم اتصال الصفيحة مع المقاطع من جهتي الجسر الشعاعي وكذلك العمود تمتد افقيا
بين فتحات البراغي ,الحظ الشكل ادناه .
لنتحقق من االتصال بين العمود والجسر الشعاعي باستخدام برنامج الروبوت االحترافي.
43 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
44 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
45 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
46 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
يتم استخدام المصطلحات التالية للمكونات الموجودة في االساس في هذا الجزء من الوصالت:
القاعدة ( - )Baseالترتيب المشترك للوحة القاعدة ،ومسامير التثبيت ،واألساس الخرساني .عادة ً ما
يتم تطبيق المصطلحات المثبتة اسميًا والصلب اسميًا على أداء القاعدة ،فيما يتعلق بصالبتها.
الصفيحة القاعدية ( - )Base Plateالصفيحة الفوالذية الموجودة في قاعدة العمود ،المتصلة بالعمود
بواسطة اللحام.
تثبيت المسامير ( - )Holding down bolts or Anchorage Boltsالبراغي من خالل لوحة
القاعدة التي يتم تثبيتها في األساس الخرساني.
األساس ( - )Foundationاألساس الخرساني المطلوب لمقاومة الضغط والرفع ،وعند الضرورة ،
عزوم االنقالب.
لوحات التثبيت ( - )Anchor Plateلوحات أو زوايا تستخدم لتثبيت مسامير التثبيت في األساس.
يجب أن تكون بالحجم الذي يوفر عامل أمان مناسب ضد فشل تحمل الخرسانة.
في معظم الحاالت ،يتم توفير قاعدة مثبتة اسميًا ،بسبب صعوبة وتكلفة توفير قاعدة صلبة اسميًا مقاومة
للعزوم .ال يقتصر األمر على كون اتصال القاعدة الفوالذية أكثر تكلفة بشكل ملحوظ ،بل يجب على األساس
ضا مقاومة اللعزوم واالحمال المحورية ،مما يزيد التكاليف بشكل كبير.
أي ً
عندما يتم دعم عوارض الرافعة ( )Crane Girdersبواسطة العمود ،قد تكون هناك حاجة إلى قواعد مقاومة
العزم لتقليل االنحرافات إلى حدود مقبولة .يتم عرض تفاصيل لوحة القاعدة /األساس النموذجية في الشكل
16.3إلى الشكل .17.3
في قاعدة مثبتة اسميًا لألعمدة األكبر ،يمكن وضع البراغي بالكامل داخل ملف تعريف العمود (الشكل 16.3
(أ)) .بالنسبة لألعمدة األصغر (أقل من 400مم تقريبًا) ،تكون اللوحة األساسية أكبر بحيث يمكن تحريك
البراغي خارج الحواف (الشكل ( 16.3ب)).
يتم تحقيق قاعدة مقاومة عزوم صلبة اسميًا من خالل توفير ذراع أكبر للمسامير ولوحة قاعدة أكثر صالبة عن
طريق زيادة سماكة اللوحة كما هو موضح في الشكل .17.3قد تكون هناك حاجة أللواح مجمعة إضافية
للوصالت الثقيلة ،كما هو موضح في الشكل .18.3
47 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C
)Figure (3-16 A
)Figure (3-17
)Figure (3-16 B
)Figure (3-18
C :لنستخدم برنامج الروبوت لتصميم وصلة العمود مع االساس الخرساني وكما يلي
. لنجرب االبعاد التالية للصفيحة ونقوم بتدقيقها, )Base Plate( تحديد ابعاد الصفيحة الرئيسية
49 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
50 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
51 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
أعلى القوى األفقية التي تعمل عند قاعدة العمود هي تلك التي تعمل للخارج نتيجة االنحناء في العمود الناتج عن
التحميل الرأسي على السطح.
يمكن مقاومة ردود الفعل األفقية تجاه الخارج بعدة طرق ،من خالل:
الضغط األرضي السلبي على جانب األساس ،كما هو موضح في الشكل ( 23.3أ)
ربطة عنق مصبوبة في بالطة أرضية متصلة بقاعدة العمود ،كما هو موضح في الشكل ( 23.3ب)
رابط عبر العرض الكامل لإلطار يربط كال العمودين أسفل أو داخل لوح األرضية كما هو موضح في الشكل
( 23.3ج) و (د).
عا لمقاومة القوى األفقية هي استخدام الضغط األرضي السلبي .هذا له مزايا إلى حد بعيد الطريقة األكثر شيو ً
اقتصادية من حيث أن حجم األساس المطلوب لمقاومة االرتفاع عادة ما يكون كافيا ً لتوفير تأثير سلبي مناسب
ضد األرض .ومع ذلك ،يمكن أن تكون المقاومة السلبية لألرض المحيطة أقل مما كان متوقعًا إذا لم يتم ضغط
األرض بشكل صحيح ،ويمكن أن تقلل خنادق الصرف والخدمة بجانب اإلطار من المقاومة السلبية إلى حد
كبير.
كبديل ،يمكن أن يكون الشريط المتصل بالعمود والمصب في بالطة األرضية ،والملفوف في النهاية للسماح
صا نسبيًا .قد تؤدي هذه التفاصيل إلى بعض التشققات المحلية في بالطة األرضية ،
بالحركة الرأسية ،رخي ً
وفي حالة استخدام بالطة أرضية عالية المواصفات ،فقد يتم إبطال الضمان على اللوح.
يجب تحديد طول الشريط بمقاومة السحب النهائية المطلوبة لمقاومة القوة األفقية.
يعتبر الربط عبر العرض الكامل لإلطار المتصل بالعمود في كل جانب هو الطريقة األكثر تأكيدًا لمقاومة القوى
األفقية .إنه أكثر تكلفة من حيث المواد والعمالة ويمكن أن يتضرر من أنشطة الموقع .سيعوق الربط الكامل
العرض بشكل عام إقامة الهيكل ،والذي سيتم تنفيذه من داخل مساحة المبنى.
52 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
53 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C Lateral restraint to portal frames 3-3-3ضبط االنحراف الجانبي إلطارات البوابة
نظرا لوجود عزوم انحناء عالية عند تقاطع العمود إلى الجسر الشعاعي ،فمن الضروري توفير تقييد االلتواء
ً
الجانبي المناسب في هذه المنطقة .يمكن القيام بذلك عن طريق ربط دعامة عرضية تربط عمود باخر عادة
ماتسمى ( . )Postيتم عرض التفاصيل النموذجية في (أ) من الشكل ،3.24حيث يتم استخدام قسم مجوف مربع
أو دائري مع لوحة نهاية.
ضا قادرة
نظرا للوحة الطرفية الملحومة ،فإنها أي ً
هذا القسم خفيف ،وكذلك قوي في كل من التوتر والضغط ؛ ً
على توفير ضبط االلتواء للعمود في هذه المنطقة شديدة اإلجهاد .يتم ربط الدعامة بنظام (أنظمة) التقوية الرأسية
في أحد طرفي المبنى أو كالهما.
عندما يتطلب العمود تقييدًا جانبيًا إضافيًا في ارتفاعه ،يمكن استخدام دعامة مماثلة ،أو يمكن ربط الحافة
الداخلية للعمود بحزام متصالب ( )Bracingكما هو موضح بالتفصيل (ب) من الشكل .3.24
ضا التقييد الجانبي للعوارض الخشبية ويتم توفير ذلك عادة ً عن طريق توصيل دعامة الجسور مطلوب أي ً
الشعاعية التقليدية بالحافة العلوية أو داخل عمق قسم العارضة ,سنعلرض هذا التقييد في مخطط الجسر الشعاعي
في التفاصيل االنشائية النهائية.
54 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
االستعداد مطلوب لمقاومة العزوم واالنحرافات التي تحدث في االعمدة والجسور الشعاعية الطولية ،وبشكل
أساسي لالستعداد لتمتين المنشأ ضد ضغط الرياح وتوفير تقوية اضافية لالعضاء لألعضاء .يجب أن يتم وضع
الدعامة بشكل صحيح وأن تتمتع بالقوة والصالبة الكافية لتبرير االفتراضات التي تم إجراؤها في التحليل
وفحص األعضاء.
لنقل األحمال األفقية إلى األرض .تشمل القوى األفقية قوى الرياح والرافعات.
لتوفير إطار صلب يمكن ربط القضبان الجانبية به حتى يتمكنوا بدورهم من توفير االستقرار لألعمدة.
لتوفير ثبات مؤقت أثناء تنصيب هيكل الحديدي للمنشأ.
وفقًا لـ ، EN 1993-1-1يجب أن تفي الدعامة بمتطلبات الفقرات 5.3.1و 5.3.2و 5.3.3للتحليل الشامل
والعيوب داخل نظام التدعيم.
قد يكون موقع التمتين عند أحد طرفي المبنى أو كالهما ،حسب طول الهيكل او في وسط المبنى وكذلك في
كل جزء بين فواصل التمدد (عند حدوث ذلك).
يمكن استخدام مقطع حديد الزواية ( )L-Sectionالمتقاطعة (داخل جدار تجويف البناء) كتدعيم (كما هو
موضح في الشكل .)25.3في هذه الحالة ،يُفترض أن األعضاء القطريين المتوترين فقط هم األكثر فعالية.
Figure (3-25): Typical cross bracing system using angles as tension members
55 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C Single central braced bay التمتين لفضاء مركزي مركزي واحد
ال يحظى مفهوم توفير لتقييد فضاء واحد بالقرب من مركز الهيكل (الشكل )3.26بشعبية بسبب الحاجة إلى
بدء االتنصيب للهيكل من منطقة الفضاء المقيد والعمل على طول المبنى بالكامل من تلك النقطة .ومع ذلك ،
تتمتع الدعامة في منتصف المبنى بميزة أنها تسمح بالتمدد الحراري الحر للمبنى ،وهو أمر ذو قيمة خاصة في
كبيرا جدًا .وال يعتبر التوسع الكلي مشكلة
مواقع مثل الشرق األوسط حيث يكون نطاق درجة الحرارة اليومية ً
بشكل عام .إذا تم استخدام فتحة مركزية (استخدام مداخل من منتصف الجملون) ،فقد يكون من الضروري
توفير دعامة مؤقتة إضافية في الخلجان النهائية للمساعدة في التنصيب.
Figure (3.26): Typical cross bracing at center of the structure to allow free thermal
expansion
عندما يكون من الصعب أو المستحيل تقوية اإلطار رأسيًا بواسطة دعامة تقليدية ،فمن الضروري إدخال اعمدة
اضافية باتجاه متعامد مع االعمدة الرئيسية لمقاومة العزوم في االرتفاعات.
إطار مقاوم للعزم في واحد أو أكثر من الفضاءات ،كما هو موضح في الشكل .3.27
استخدام االرتفاع الكامل لمقاومة القوى الطولية ،مع وجود اتصال مقاوم للعزم غالبًا في الفضاءات
النهائية ،حيث يتم تدوير عمود النهاية بمقدار 90درجة لتوفير مزيد من الصالبة في االتجاه الطولي
،كما هو موضح في الشكل .27.3هذا الترتيب ممكن فقط إذا كان اإلطار النهائي (الجملون) مبنيًا من
ترتيب شعاع وعمود ،بدالً من إطار بوابة.
56 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
Figure (3.27): Individual, local sway frames and Hybrid frame along the full length
of the building
57 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
يتم وضع التمتين للسقوف في المستوى األفقي ،أو في مستوى السطح .الوظائف األساسية هي:
لنقل قوى الرياح األفقية من أعمدة الجملونات إلى التمتين الراسي ( )Vertical Bracingفي الجدران
لنقل أي قوى سحب تشكلها الرياح على السطح إلى التمتين الراسي.
لتوفير الثبات أثناء التنصيب للمنشأ.
وفقًا لـ ، EN 1993-1-1يجب أن تفي الدعامة بمتطلبات الفقرات 5.3.1و 5.3.2و 5.3.3للتحليل الشامل
والعيوب داخل نظام التدعيم.
استخدام مقاطع حديد الزاوية ليس شائعًا في الهياكل الحديثة ،ولكن الزوايا المتقاطعة لها ميزة في أن األعضاء
القطرية صغيرة نسبيًا ألنها قد تكون مصممة لمقاومة التوتر ( )Simple Barsفقط (الشكل .)28.3
Figure (3-28): Plan view showing both end bays braced using crossed angle
sections
لذلك فان المصممون في العراق يميلون الى استخدام مقاطع حديد الزاوية في التمتين والتصالب مع الربط مع
العمود والجسور الشعاعية بواسطة لحام صفائح بارزة من جسم العمود والجسر وتمتلك ثقوب للتثبيت بواسطة
البراغي مع حديد الزاوية .الحظ استكمال المثال التصميمي ,الشكل (.)3.29
58 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
59 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
Figure (3-31): Plan and Vertical Bracing of Portal Frame using L-section
60 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
61 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
62 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
63 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
64 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
65 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C 4-3الجملونات ذات االتصال الثابت مع االسس Portal Frame with Fixed Connection
بالنسبة للقواعد المثبتة تثبيتا اليقاوم العزوم في نقطة االتصال بين صفيحة العمود واالساس الخرساني
( ، )Pinned Connectionيتم تجاهل أي عزم عند قاعدة العمود ويتم تصميم القاعدة للقوى المحورية وقوى
القص فقط في قاعدة العمود .قد يكون اثنان من البراغي كافيين لمقاومة قوى الشد ،لكن استخدام أربعة مسامير
كما هو موضح في المثال التصميمي رقم 1السابق ،يسمح للحفارات بالوقوف وسحب األعمدة بسهولة أكبر.
ضا اتصال لمقاومة العزوم ،حيث يشير مصطلح العزوم إلى تحميل االنحناء) عمود القاعدة الثابت (يسمى أي ً
هو أكثر من اتصال قاعدة االتصال البسيط ( .)Pinned Connectionتتميز هذه القاعدة بصالبة كبيرة وستقوم
بتطبيق أحمال أفقية ورأسية والعزوم على األساسات .الصالبة اإلضافية في القاعدة وفي األعمدة ،تعني أقل
صالبة مطلوبة من باقي أعضاء المبنى .قد تحتاج األساسات إلى أن تكون أكبر من تلك المستخدمة للقاعدة
ضا بسبب األلواح اإلضافيةالمثبتة بسبب هذه العزوم .يمكن أن يكون تركيب أعمدة القاعدة الثابتة أكثر صعوبة أي ً
ضا أعمدة مستقيمةالموجودة على العمود وقضبان التثبيت المطلوبة .يجب أن تكون أعمدة القاعدة الثابتة أي ً
وتكون عادة ً أعمق في قاعدتها مقارنة بالقاعدة المثبتة .عادة ما تكون أعمدة القاعدة الثابتة متوقفة أسفل األرضية
66 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C النهائية .يمثل الرسم الخاص بعمود القاعدة الثابت ،الموجود إلى اليسار ،مجرد مثال لما يمكن أن تبدو عليه
اللوحة األساسية .هناك عدد قليل من الخيارات لهذه الحالة اعتمادًا على حجم المبنى والتحميل.
67 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C في هذه المرحلة ،يكون اختيار المالك بين قبول (أمر تغيير كبير) من المقاول لتغييراألساس أو معركة مطولة
مع الشركة المصنعة للمباني المعدنية .كان من الممكن تجنب كليهما بسهولة من خالل إدراج جملة واحدة في
رسومات العقد والمواصفات" :يجب أن يكون ألعمدة البناء الهيكلي (الحديدية) في اعمال الهندسة قواعد
مثبتة بشكل بسيط ولن تنقل أي عزوم إلى األساسات".
عادة ً ما تُعتبر قاعدة األعمدة ذات االثنين واألربعة براغي دعامة مثبتة اسميًا في التحليل الهيكلي .ومع ذلك ،
يمكن االستفادة من صالبة القواعد المثبتة اسميًا لتقليل انحرافات اإلطار وتقليل تأثيرات التشوهات في المقاطع.
68 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
مثال تصميمي رقم : 2يراد تصميم مصنع لالثاث بابعاد 55:متر طول و 40متر عرض ,المنشأ اليحوي
على رافعات لالثقال والمواد الخام واستخدام مقاطع حديد اوربية .
سرعة الرياح للمنطقة 30متر/ثانية وقابلية تحمل التربة 10طن /م 2ويراد مخططات انشائية للتصنيع في
المعامل وتركيبها في الموقع.
تحتاج المخططات الى المصادقة من مكاتب استشارية معتمدة من وزارة التخطيط لذا يتطلب تثبيت كافة
المعلومات وخواص المواد المستخدمة مع المدونات التي استخدمت في التصميم على اساسها .لذلك سنبدأ بلوحة
المعلومات العامة التي تكون دائما في بداية اللوحات.
69 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
70 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
71 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
72 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
73 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
74 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
عندما تكون الرافعة ذات سعة منخفضة نسبيًا (حتى 20طنًا) ،يمكن تثبيت األقواس على األعمدة لدعم الرافعة.
قد يكون من الضروري استخدام عضو ربط أو قواعد أعمدة ثابتة لتقليل انحراف العمود .قد تكون الحركة
الخارجية لإلطار على مستوى سكة الرافعة ذات أهمية حاسمة لعمل الرافعة.
بالنسبة للرافعات الثقيلة ،من المناسب دعم قضبان الرافعة على أعمدة إضافية ،والتي قد تكون مرتبطة بعمود
اإلطار بواسطة دعامة بسبب مشاكل عدم االستقرار.
75 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
76 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
77 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
78 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
عندما نحتاج الى جملونات بعرض كبير نسبيا كما في المسابح والمالعب الرياضية المغلقة فيمكن استخدام
جسور شعلعية منحنية .
هذا االجراء لطيف من الناحية المعمارية ولكنه يسبب عدة مشاكل تقنية واقتصادية وهي:
اليمكن استخدام الرافعات الثقيلة لعرض جملون يزيد على 25متر بسبب شدة انحراف وتشوه -1
الجسور الشعاعية.
صعوبة ثني المقاطع القياسية للجسور اثناء التصنيع ,وتحتاج الى دقة عالية لمطابقة الجسور -2
للفضاءات المتعاقبة.
نحتاج خفض االرتفاع بسبب االنحناء ويكون هذا االجراء من خالل خفض ارتفاع االعمدة الجانبية. -3
تكون الجسور ثقيلة خاصة مع الفضاء الذي يزيد على 30متر مما يلزم تكوين فتحات في الجسور -4
لتخفيف الوزن ,بالرغم من ان هذه الفتحات تكون مفيدة لمد البنى التحتية لالنابيب التبريد ةاالنارة
والتغذية الكهربائية العامة.
79 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C
يراد تصميم جملون كمعارض فنية بابعاد 20متر عرض و 35متر طول وكان التصميم المعماري يضهر
فيه السقف كمنحني للجمالية .
80 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
81 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
82 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
يتكون إطار البوابة المنحدرة من سلسلة من الجسور الشعاعية المتالية والمرتبطة مع بعضها ومثبتة بوصالت
ترخيم للمقطع (كما في الشكل .)4.2يمكن استخدامه عند الحاجة إلى مساحة كبيرة واضحة ولكن يجب تقليل
ارتفاع العمود للمبنى .قد يكون المنحدر المربوط حالً اقتصاديًا حيث توجد حاجة لتقييد اعمدة وسطية تعيق
وضيفة المبنى الذي يرغب بان يكون مفتوحا للحركة بدون عوائق.
طيا مثال تصميمي لجملون أطار البوابة المنحدرة الجسور الشعاعية وهو غير منتظم االبعاد ويشكل تحديا في
التصميم والتصنيع تم تنفيذه في مدينة بغداد الحبيبة.
83 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
84 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
85 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
86 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
87 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
Eaves and Rafters for Axis (16)
C
88 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
89 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
90 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
91 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
92 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
93 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
Eaves and Rafters for Axis (12)
C
94 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
95 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
96 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
97 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
98 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
99 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
100 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
طا وثيقًا في ديمومة المنشأ الخزني والصناعي ،ألن األضرار الناتجة ترتبط الحماية الحرارية والرطوبة ارتبا ً
عن الرطوبة غالبًا ما تكون نتيجة نقص العزل الحراري أو تثبيت االنهاءات بشكل غير صحيح .في اإلنشاءات
متعددة األسطح أو الجدران ،يجب منع اختراق الرطوبة عن طريق تركيب حاجز مانع لتدفق البخار على الجلد
الداخلي للهيكل .تكون هياكل الجدران مقاومة للبخار على كال الجانبين ،مثل األلواح العازلة ،وتمنع انتشار
البخار .ولهذا السبب ،يجب تنظيم الرطوبة في القاعة من خالل إجراءات تكييف الهواء.
يجب حماية االعضاء االنشائية المالمسة للتربة مثل االسس واالجزاء االنشائية المرتبطة معها مثل صفيحة
القاعدة والستدات وهناك اجراءات يمكنك مالحظتها في الشكل ادناه.
يمكن أن يؤثر تصميم وتفاصيل الهيكل على متانة أي طالء واقي مطبق عليه .يصعب حماية الهياكل المصممة
بالعديد من المكونات الهيكلية الصغيرة والمثبتات أكثر من األسطح المسطحة الكبيرة .تشمل القضايا الرئيسية
التي يجب مراعاتها ما يلي:
يمكن العثور على إرشادات عامة للوقاية من التآكل من خالل تفاصيل التصميم الجيدة في BS EN ISO
، 12944-3وترد أدناه بعض اإلجراءات والواجبات النموذجية للمباني ذات اإلطارات الفوالذية.
102 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
ال يعني مصطلح مقاومة الحريق بالضرورة أن العنصر االنشائي ال يمكن أن يحترق أبدًا :إنه يتعلق باألداء
المقاس في ظل ظروف محددة لالختبار والتقييم .ال تسمح ميزة مقاومة الحريق بأن تكون العناصر المعالجة
غير متأثرة تما ًما بأي حريق ،حيث إن المواد التقليدية ليست محصنة ضد تأثيرات الحريق بكثافة و /أو مدة
كافية.
يتم استخدام مقاومة الحريق في المنشاءات الصناعية والخزنية لتقليل تصاعد الحريق الذي قد يحدث مع فشل
الدعامات الهيكلية وارتفاع درجة حرارة أوعية الضغط .قد يؤدي الضرر الذي يمكن أن تحدثه النيران في وقت
مبكر جدًا إلى إضافة وقود كبير إلى النار.
لذلك ،فإن الغرض من مقاومة الحريق هو كسب الوقت .الطريقة التقليدية للحماية من الحريق هي صب
الخرسانة في الموقع أو الجونيت .يتم استخدام مواد مقاومة للحريق أخرى ،مثل األسمنت خفيف الوزن ،
واأللواح األسمنتية الجاهزة ،والطالء المنتفخ بدرجة أقل ،في المقام األول في المناطق التي تعتبر أقل خطورة
وحيث يكون تقليل الوزن فائدة كبيرة.
الطالءات المنتفخة هي مواد شبيهة بالطالء تكون خاملة عند درجات حرارة منخفضة ولكنها توفر العزل نتيجة
لتفاعل كيميائي معقد عند درجات حرارة تتراوح عادة ً بين 200و 250درجة مئوية .في درجات الحرارة هذه
لن تتأثر خصائص الفوالذ .ونتيجة لهذا التفاعل فإنها تنتفخ وتوفر طبقة موسعة من الفحم منخفض التوصيل.
يمكن تقسيم الطالءات المنتفخة إلى عائلتين واسعتين :األغشية الرقيقة واألغشية السميكة .تكون مواد األغشية
الرقيقة إما ذات أساس مذيب أو مائي وتستخدم بشكل أساسي في حرائق المباني .تم تطوير الطالءات الغشائية
السميكة في األصل للصناعات البحرية والهيدروكربونية ولكن تم تعديلها لالستخدام في المباني.
تطبيق الطالءات
الرقيقة المنتفخة
خارج الموقع
103 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
أمرا شائعًا جدًا ,تستخدم األلواح على نطاق واسع يعتبر التداخل بين األلواح والطالءات الرقيقة المنتفخة ً
للحماية من الحرائق الهيكلية في المملكة المتحدة .يتم استخدامها حيث يكون نظام الحماية مرئيًا وأينما يكون
مظهرا نظيفًا ومعبأًا ولديها مزايا إضافية تتمثل في أن التطبيق عبارة عن تجارة جافة
ً مخفيًا .إنها توفر للمحدد
وقد ال يكون لها تأثيرات كبيرة على األنشطة األخرى .كما يتم تصنيع األلواح في المصنع ويمكن ضمان
السماكات .عالوة على ذلك ،يمكن تطبيق األلواح على األعمال الفوالذية غير المطلية.
توجد على نطاق واسع عائلتان لحماية اللوحة ،خفيفة الوزن وثقيلة الوزن .عادة ً ما تكون األلواح خفيفة الوزن
250-150كجم /م 3وال تكون مناسبة عادة ً للتشطيبات الزخرفية .يتم استخدامها عادة ً عندما ال تكون الجماليات
3
مهمة وأرخص من نظائرها من الوزن الثقيل .يتراوح وزن األلواح الثقيلة عادة بين 700و 950كجم /م
(يجب على المصممين االنشائيين اخذ هذا الحمل ضمن االعتبارات) وستقبل بشكل عام التشطيبات الزخرفية.
يتم استخدامها عادة حيث تكون الجماليات مهمة.
يمكن استخدام كال النوعين من األلواح في ظروف خارجية محدودة ولكن يجب طلب مشورة الشركة المصنعة.
تتوفر إرشادات مفصلة حول تركيب أنظمة حماية اللوحة من جمعية الحماية من الحرائق المتخصصة
يعتبر التداخل بين األلواح يمكن تشكيل األلواح حول أشكال معقدة
أمرا
والطالءات الرقيقة المنتفخة ً
شائعًا جدًا
104 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
عا في المملكة المتحدة .تتميزتستخدم الحماية بالرش على نطاق واسع في الواليات المتحدة ولكنها أقل شيو ً
ضا أن التكاليف ال تزيد بشكل كبير مع بميزة أنها يمكن استخدامها لتغطية األشكال والتفاصيل المعقدة وأي ً
الزيادات في سمك الحماية .هذا ألن الكثير من تكلفة التطبيق في العمالة والمعدات وأقلية في تكلفة المواد .يمكن
ضا استخدام بعض المواد في التطبيقات الخارجية وتطبيقات الحرائق الهيدروكربونية. أي ً
ضا ،يعد التطبيق تجارة رطبة وقد يكون لذلك تأثيرات على البخاخات ليست مناسبة لألغراض الجمالية .أي ً
عمليات الموقع األخرى .قد يتعين تخصيص بدل في حساب تكلفة المتطلبات المحتملة لمنع الرش الزائد .تتوفر
إرشادات مفصلة حول تركيب أنظمة الحماية من الرش من جمعية الحماية من الحرائق المتخصصة
تم تطوير أنظمة مرنة للحماية من الحرائق كاستجابة للحاجة إلى مادة حماية من الحرائق سهلة التطبيق يمكن
استخدامها في األشكال والتفاصيل المعقدة ولكن عندما يكون التطبيق تجارة جافة .هناك عدد محدود من
الشركات المصنعة لهذه المنتجات .يظهر تثبيت البطانية في الصورة المصاحبة.
105 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
لسنوات عديدة ،كانت الجسور الحديدية ذات الفتحات الشبكية المتعددة المصنعة عن طريق شق ولحام العوارض
واألعمدة المدلفنة على الساخن (الحزم المصقولة والخلوية) ،محمية من الحريق على أساس عامل المقطع
للقسم الرئيسي زائد .٪20اعتمد هذا على نتائج عدد من االختبارات على الجسور الشعاعية في الجملونات التي
أظهرت زيادة طفيفة في معدل التسخين مقارنة بالمقاطع المدلفنة على الساخن .عندما تم تطوير عملية تصنيع
الجسور الشعاعية الخلوية من الصفائح ،تم اإلبقاء على قاعدة الـ .٪20تم أخذ درجة الحرارة المحددة
االفتراضية ل الجسور الشعاعية الخلوية على أنها مماثلة للحزم المدلفنة على الساخن التي تحمل ألوا ًحا خرسانية
،أي 620درجة مئوية للطالء الرقيق المنتفخ و 550درجة مئوية للرش واأللواح.
ومع ذلك ،بمرور الوقت ،أظهرت االختبارات اإلضافية أن الجسور الشعاعية يمكن أن تعرض آليات فشل
معقدة في الحريق .تم اآلن تطوير فهم أفضل لهذه اآلليات ،ومن هذا المنطلق ،أصبح من الواضح أن االفتراض
بأن درجة الحرارة المحددة لهذه الحزم هي نفسها لألقسام غير المثقوبة غير صحيحة .وبدالً من ذلك ،فقد ثبت
أن هندسة الحزمة تحدد درجة الحرارة المحددة وأن كل حزم خلوية تحتاج إلى تقييم بنا ًء على مزاياها الخاصة.
الحلول المعممة (أو العالمية) ليست مناسبة.
106 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
Material Design Properties for Structural Steel S235, S275, S355, S420, S450,
S460 according to EN1993-1-1 §3.2.6
107 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C
EN10025-5 Hot rolled products - Normalized/normalized rolled wieldable fine
grain structural steels
Symbol Description S235 W S355 W
fy (MPa) Yield strength 235 355
fu (MPa) Ultimate strength 360 490
EN10025-6 Hot rolled products - High yield strength structural steels in the
quenched and tempered condition
Symbol Description S460 Q/QL/QL1
fy (MPa) Yield strength 460
fu (MPa) Ultimate strength 570
EN10210-1 Hot finished structural hollow sections - Non-alloy and fine grain
steels
Symbol Description S235 H S275 H S355H S275NH/NLH
fy (MPa) Yield strength 235 275 355 275
fu (MPa) Ultimate strength 370 430 510 390
EN10219-1 Cold formed welded structural hollow sections - Non-alloy and fine
grain steels
Symbol Description S235 H S275 H S355H S275NH/NLH
fy (MPa) Yield strength 235 275 355 275
fu (MPa) Ultimate strength 360 430 510 370
Structural Steel Strength Properties for elements with nominal thickness 40 mm < t
≤ 80 mm
108 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C
EN10025-3 Hot rolled products - Normalized/normalized rolled wieldable fine
grain structural steels
Symbol Description S235N/ S275 S355 S460 N/NL
NL N/NL N/NL
fy (MPa) Yield strength 255 335 390 430
fu (MPa) Ultimate strength 370 470 520 540
EN10210-1 Hot finished structural hollow sections - Non-alloy and fine grain
steels
Symbol Description S235 H S275 H S355H S275NH/NLH
fy (MPa) Yield strength 215 255 335 255
fu (MPa) Ultimate strength 340 410 490 370
:مالحظات
109 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C على الساخن .درجات الصلب التي تحمل التصنيف " ، "Hوفقًا لمعيار EN 10219-1قابلة للتطبيق
على المقاطع المجوفة الهيكلية المشكلة على البارد .انظر التفاصيل أدناه للحصول على وصف لمعيار
ENذي الصلة.
-2تتميز درجات الصلب الفرعية JRو J0و J2و K2بقدرة الفوالذ على التصرف بطريقة مطيلة
وبالتالي تجنب الكسر الهش ،خاصة في درجات الحرارة المنخفضة .تتميز صالبة كسر الفوالذ في
EN 1993-1-10من حيث قيمة ) ، KV (Tأي طاقة الصدم بالجول [ ]Jالمطلوبة لكسر عينة
Charpy V-notchعند درجة حرارة اختبار معينة -T. Subيتوافق الصف JRمع KVبحد أدنى
J 27عند درجة حرارة الغرفة ( 20 +درجة مئوية) .تتوافق الدرجة الفرعية J0مع حد أدنى من KV
يبلغ J 27عند 0درجة مئوية .تتوافق الدرجة الفرعية J2مع حد أدنى من KVيبلغ J 27عند 20-
درجة مئوية.
-3يستمد الصلب خصائصه المادية من مزيج من التركيب الكيميائي والعمل الميكانيكي والمعالجة
الحرارية .التركيب الكيميائي أساسي للخصائص الميكانيكية للصلب .يمكن أن تؤدي إضافة سبائك مثل
الكربون والمنغنيز والنيوبيوم والفاناديوم إلى زيادة القوة .ومع ذلك ،فإن إضافات السبيكة هذه تزيد
من تكلفة الفوالذ ،ويمكن أن تؤثر سلبًا على الخصائص األخرى (مثل الليونة والصالبة وقابلية اللحام).
ضا إلى تعزيز الليونة ،ويمكن تحسين المتانة بإضافة
يمكن أن يؤدي الحفاظ على مستوى الكبريت منخف ً
النيكل .ومن ثم ،فقد تم اختيار التركيب الكيميائي لكل مواصفات الصلب بعناية لتحقيق الخصائص
المطلوبة.
-4ربما تكون قوة الخضوع هي الخاصية األكثر أهمية التي سيحتاج المصمم إلى استخدامها أو تحديدها.
كان تحقيق قوة مناسبة مع الحفاظ على الخصائص األخرى هو القوة الدافعة وراء تطوير عمليات
تصنيع ودرفلة الفوالذ الحديثة .على سبيل المثال فوالذ S355عبارة عن فوالذ إنشائي بأقل مقاومة
للخضوع ( )ReHتبلغ 355نيوتن /مم .2الرقم المذكور في التسمية هو قيمة مقاومة الخضوع للمادة
التي يصل سمكها إلى 16مم .يجب أن يالحظ المصممون أن مقاومة الخضوع تقل مع زيادة سماكة
اللوح أو المقطع .يوجد في الجدول أدناه مثال للفوالذ الشائع في .EN 10025-2
Steel > 16 > 40 > 63 > 80 > 100
grade ≤ 16 ≤ 40 ≤ 63 ≤ 80 ≤ 100 ≤ 150
)Nominal thickness (mm
S275 275 265 255 245 235 225
S355 355 345 335 325 315 295
S460 460 440 420 400 390 390
110 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C -5في العراق ،يتم الحصول على القيم االسمية لقوة الخضوع ) (fyللصلب اإلنشائي من الوثائق
المصاحبة للحديد المستورد ،وبالتالي القيم المميزة المستخدمة في حسابات التصميم ،من خالل اعتماد
قيم مقاومة الخضوع الدنيا ) (ReHمباشرة من معايير المنتج هذه .غالبًا ما يستخدم الفوالذ S275في
اغلب المنشاءات للبنايات الصناعية والخزنية في العراق ،حيث تتحكم الصالبة بدالً من القوة في
التصميم ،أو عندما يكون االجهاد او التعب ( )fatigueهو حالة التصميم الحاسمة .يستخدم الفوالذ
S355بشكل أساسي في تطبيقات جسور الطرق السريعة ،حيث إنه متوفر بسهولة ،ويعطي عمو ًما
التوازن األمثل بين الصالبة والقوة .يمكن أن يوفر الفوالذ S460مزايا عندما يكون الوزن الذاتي أم ًرا
بالغ األهمية أو يحتاج المصمم إلى تقليل سماكة األلواح .ومع ذلك ،فإن استخدام مثل هذا الفوالذ ال
يمنح أي فوائد في التطبيقات التي يكون فيها التعب أو الصالبة أو عدم استقرار األعضاء النحيلة للغاية
هو االعتبار الرئيسي للتصميم .كما أن هذا الفوالذ غير متوفر بسهولة في العراق والبلدان المجاورة.
111 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
بالنسبة للوحات ،عادة ً ما تكون الفئة Aإلى EN 10029كافية .الفئة Aهي اإلعداد االفتراضي في
EN 10025-2ويتم تأكيد اختيارها في مواصفات أعمال المنشاءات الخزنية والصناعية .تزداد تفاوتات
السماكة في الصنف Aبالسمك االسمي على النحو التالي:
في ادناه شكال يمثل بعض حاالت االرضية الخرسانية المسلحة لقاعة الجملون الخاصة بالخزن او الفعاليات
الصناعية .
112 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
لطالما نوقش قرار تحديد موقع مثبط /حاجز البخار في اتصال مباشر مع الجانب السفلي للبالطة .ومع ذلك
،فقد أظهرت التجربة أن أعلى مستوى من الحماية ألغطية األرضيات أو الطالءات أو بيئات البناء يتم
توفيره عندما يتم وضع مثبط /حاجز البخار في اتصال مباشر مع اللوح .إن وضع الخرسانة في اتصال
مباشر مع مثبط /حاجز البخار يلغي احتمالية احتباس الماء من مصادر مثل المطر أو المعالجة أو التنظيف
أو الضغط داخل مسار الملء .يمكن للحشو المبلل أو المشبع فوق مثبط /حاجز البخار أن يطيل بشكل كبير
الوقت المطلوب لتجف البالطة إلى مستوى مقبول لمصنعي أغطية األرضيات والمواد الالصقة والطالء.
ضا كطريق لدخول الرطوبة والسفر طبقة تعبئة محصورة بين مثبط البخار /الحاجز والخرسانة تعمل أي ً
بحرية أسفل البالطة.
نظرا ألن أداء البالطة على األرض يعتمد على سالمة نظام دعم التربة ،يجب إيالء اهتمام خاص لمتطلبات ً
إعداد الموقع ،بما في ذلك عامل الرص للتربة .في معظم الحاالت ،تكون نتائج مستوى الرص أكثر داللة
على قدرة نظام دعم التربة على تحمل التحميل مقارنة بنتائج االختبارات الموضعية لمحتوى الرطوبة أو
الكثافة .عادة ً ما تُستخدم طبقة رقيقة من المواد المتدرجة الحبيبية القابلة للضغط كمواد تصنيف دقيقة للتحكم
بشكل أفضل في سماكة الخرسانة وتقليل االحتكاك بين المادة األساسية والبالطة.
يجب استخدام وصالت العزل حيثما كانت الحرية الكاملة للحركة الرأسية واألفقية مطلوبة بين األرضية
وعناصر البناء المجاورة .يجب استخدام مفاصل العزل عند التقاطعات مع الجدران التي ال تتطلب قيودًا
جانبية من البالطة أو األعمدة أو أسس المعدات أو القواعد أو نقاط تقييد أخرى مثل المصارف وغرف
التفتيش واألحواض والساللم .يمكن أن يتكون مفصل العزل من مادة صاج أو مادة مفصلية مسبقة التشكيل
تفصل عنصرين خرسانيين متجاورين ؛ أحد األمثلة على ذلك هو المكان الذي تتاخم فيه اللوح مع الحائط.
عندما يحد مفصل العزل من االنكماش ،يجب استخدام لوح رغوة مرن مغلق الخلية ) مثل الفلين
اوالستايربور) بسماكة تتالءم مع حركة االنكماش المتوقعة.
يجب أن تمتد مادة الوصلة إلى العمق الكامل للبالطة أو أسفل قاعها بقليل لضمان الفصل التام .عندما يكون
حشو المفصل مرئيًا بشكل غير مقبول ،أو عندما تكون هناك ظروف رطبة أو متطلبات صحية أو للتحكم
في مناطق تجمع الغبار ،يمكن إزالة الجزء العلوي من الحشو المسبق التشكيل وسد المفصل باستخدام مادة
مانعة للتسرب من اللدائن المرنة .ثالث طرق إلنتاج عمق موحد نسبيًا لعمق مانع التسرب هي:
113 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C منشارا للقص على العمق المراد إزالته .أدخل الحشو في المكان المناسب .بعد أن تصلبً oاستخدم
الخرسانة ،استخدم مفك براغي أو أداة مشابهة وقم بإزالة الجزء العلوي.
oقطع شريط من الخشب يساوي العمق المطلوب لمانع التسرب المشترك .ثبت الشريط الخشبي على
الحشو ال ُمشكل مسبقًا وقم بتثبيت التجميع في المكان المناسب .قم بإزالة شريط الخشب بعد أن تصلب
الخرسانة.
oاستخدم حشو مفصل مسبق الصب مع جزء علوي قابل لإلزالة.
المعوضة
ّ ارجع إلى ACI 223Rللحصول على إرشادات حول فواصل العزل لأللواح باستخدام الخرسانة
لالنكماش.
-4فواصل البناء -توضع فواصل البناء في بالطة لتحديد مدى مواضع الخرسانة الفردية ،بشكل عام بالتوافق
مع تخطيط المفصل المحدد مسبقًا .إذا تم قطع صب الخرسانة لفترة كافية لتصلب الخرسانة الموضوعة ،
فيجب استخدام مفصل البناء .إذا أمكن ،يجب أن تكون فواصل البناء على بعد 5أقدام ( 1.5م) أو أكثر من
أي مفاصل أخرى تكون متوازية .في المناطق غير الخاضعة لحركة المرور ،يكون مفصل المؤخرة مناسبًا
عادةً .في المناطق المعرضة لحركة المرور الصعبة ،أو األحمال الثقيلة ،أو كليهما ،يوصى باستخدام
الوصالت ذات المسامير .ال يوصى باستخدام الوصالت ذات المفاتيح عند الحاجة إلى نقل الحمولة ألن
جانبي مجرى المفتاح يفقدان االتصال عند فتح المفصل بسبب انكماش التجفيف.
114 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C APPENDIX D:
This example covers the design of a portal frame for a single-storey building, using
the elastic method of global analysis. Only gravity loads are covered in this example.
The frame uses hot rolled I sections for rafters and columns.
يتم. باستخدام الطريقة المرنة للتحليل الشامل، يغطي هذا المثال تصميم إطار البوابة لمبنى من طابق واحد
المدلفنة على الساخن للجسور الشعاعيةI يستخدم اإلطار أقسام.تغطية أحمال الجاذبية فقط في هذا المثال
.واألعمدة
2. Frame geometry
The cladding to the roof and walls is supported by purlins and side rails. The purlins
have been provisionally located at intervals of between 1500 mm and 1800 mm as
shown. The side rails are provisionally located at intervals of no more than 2000
mm. The rafter and column verifications may require these locations to be modified.
115 | P a g e
C
Industrial and Warehouse Steel Structure
3. Loads EN 1991-1-1
G = Gself-weight + Groof
116 | P a g e
For an internal frame: Groof = 0,30 × 7,20 = 2,16 kN/m
Industrial and Warehouse Steel Structure Structural Drawing
The characteristic value for snow loading on the roof for a specific location in a
given country at certain altitude has been calculated as:
sk = 0,618 kN/m²
qk = 0,4 kN/m2
117 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
For simplicity, the wind actions are not considered in this example.
Therefore, the critical design combination for choosing the member size is: γG
G + γQ Q
Where:
The snow loads are greater than the imposed loads on the roof, therefore
Q = 4,45 kN/m
4. Preliminary sizing
Rafter load = 1,35( 2,16 + self-weight )+1,5 x 4,45 = 9,6 kN/m + self-weight
118 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
In order to evaluate the sensitivity of the frame to 2nd order effects, the buckling
amplification factor, αcr, has to be calculated. This calculation requires the
deflections of the frame to be known under a given load combination.
According to the code, if the axial compression in the rafter is significant then αcr is
not applicable. In such situations, Appendix B of this document recommends the use
of αcr,est instead.
NEd is the design axial load at ULS in the rafter, noted NR,Ed in this example.
Lcr is the developed length of the rafter pair from column to column.
119 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
Therefore the axial compression in the rafter is significant and αcr from
EN 1993-1-1 is not applicable.
For a pitched roof frame: αcr,est = min(αcr,s,est; αcr,r,est) , αcr,r,est only needs to
be checked for portal frames of 3 or more spans. When assessing frame stability,
allowance can be made for the base stiffness.
In this example, a base stiffness equal to 10% of the column stiffness has been
assumed to allow for the nominally pinned bases. To calculate αcr, a notional
horizontal force is applied to the frame and the horizontal deflection of the top of the
columns is determined under this load. The notional horizontal force is:
The horizontal deflection of the top of the column under this force is obtained from
the elastic analysis as 1,6 mm.
120 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
First order elastic analysis may be used and second order effects do not need to be
allowed for.
The total reactions for the structure to determine HEd and VEd.
121 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C
Therefore the initial sway imperfections have to be taken into account.
This force is applied at the top of each column, in combination with the permanent
and variable actions.
For the ULS analysis, the bases are modeled as pinned. Otherwise the base details
and foundation would need to be designed for the resulting moment. The following
figure shows the internal forces on the frame subject to the ULS loads including the
equivalent horizontal forces.
The cross-section resistance and the buckling resistance are verified for each
member. Sections 7.1and 7.2 provide a summary of the checks carried out for each
member of the frame.
122 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C The resistance of the cross-section has to be verified in accordance with Section 6.2
of EN 1993-1-1.
In addition, bending and shear interaction, as well as bending and axial force
interaction must be verified.
The rafters and the columns must be verified for out-of-plane buckling between
restraints and in plane buckling.
The buckling checks due to the interaction of axial force and bending moment are
carried out using Expressions 6.61 and 6.62 from EN 1993-1-1.
Expression (6.61) is used to verify in-plane buckling, and expression (6.62) is used
to verify out-of-plane buckling.
123 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
124 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
When shear force and bending moment act simultaneously on a cross-section, the
shear force can be ignored if it is smaller than 50% of the plastic shear resistance.
Therefore the effect of the shear force on the moment resistance may be neglected.
When axial force and bending moment act simultaneously on a cross-section, the
axial force can be ignored provided the following two conditions are satisfied:
Therefore the effect of the axial force on the moment resistance may be neglected.
125 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
If the tension flange is restrained at discreet points between the torsional restraints
and the spacing between the restraints to the tension flange is small enough,
advantage may be taken of this situation. In order to determine whether or not the
spacing between restraints is small enough, Annex BB of EN 1993-1-1 provides an
expression to calculate the maximum spacing. If the actual spacing between
restraints is smaller than this calculated value, then the methods given in Appendix
C of this document may be used to calculate the elastic critical force and the critical
moment of the section.
In this case the restraint to the tension flange is provided by the side rails. These side
rails are spaced at 1900 mm. The limiting spacing as given by Annex BB of EN
1993-1-1 is:
126 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C C1 is a factor that accounts for the shape of the bending moment diagram. C1 values
for different shapes of bending moment diagrams .For a linear bending moment
diagram, C1 depends on the ratio of the minimum and the maximum bending
moments in the segment being considered.
The ratios of bending moments for the middle and bottom segments of the column
(without considering the haunch) are as follows:
C1 = 1,31 is the most onerous case and therefore this is the case that will be analyzed.
Therefore the normal design procedure must be adopted and advantage may not be
taken of the restraints to the tension flange.
Firstly the whole column is verified. If the flexural buckling, lateral torsional
buckling and interaction checks are satisfied for the length of the whole column, no
further restraints are required. Otherwise, intermediate torsional restraints will be
introduced to the column, or the column size increased.
127 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
The restraint must be at a side rail position, since bracing from the side rail to the
inner flange is used to provide the torsional restraint.
As previously, the flexural buckling and the lateral torsional buckling checks are
carried out separately before proceeding to verify the interaction between the two.
128 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
EN 1993-1-1 §6.3.2.2
129 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
EN 1993-1-1
§6.3.3(4)
EN 1993-1-1 Annex B Table
B.2
130 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
EN 1993-1-1 §6.3.1.3
EN 1993-1-1 §6.3.1.2
131 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
132 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
In Section 7.4 it has been demonstrated that the cross-sectional resistance of the
section is greater than the applied forces. The out-of-plane and in-plane buckling
checks have been verified in Sections 7.5 and 7.6 for the appropriate choice of
restraints along the column. Therefore it is concluded that the IPE 500 section in
S355 steel is appropriate for use as columns in this portal frame.
133 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
134 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C
EN 1993-1-1 §6.2.4
EN 1993-1-1 §6.2.9
135 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
136 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
8. Hunched length
The haunch is fabricated from a cutting of an IPE 550 section. Checks must be
carried out at end and quarter points, as indicated in the figure below.
137 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C From the geometry of the haunch, the following properties can be obtained for each
of the cross-sections 1 to 5, as shown in Table below.
The section properties are calculated normal to the axis of the section.
For simplicity, the section properties above have been calculated assuming a
constant web thickness of 9,4 mm and neglecting the middle flange. The actual and
the equivalent cross-sections are shown in the following figure for cross-section
No.1:
For cross-section No.1 the values of NEd and MEd are taken at the face of the column.
138 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
The web can be divided into two webs, and classified according to the stress and
geometry of each web. The upper section (i.e. the rafter) is called the upper web and
the lower section (i.e. the cutting) is called the lower web.
Upper web
By inspection the upper web will be Class 3 or better, because it is mostly in tension.
Lower web
The distance from the bottom flange to the elastic neutral axis is:
z = 451,4 mm
139 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
140 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
9. Deflections
The horizontal and vertical deflections of the portal frame subject to the
characteristic load combination, as per Expression 6.14 of EN 1990 are as follows:
141 | P a g e
Industrial and Warehouse Steel Structure Structural Drawing
C
References
1. Duoc T. Phan, James B.P. Lim, Tiku T. Tanyimboh, R. Mark Lawson. (2013).
EFFECT OF SERVICEABILITY LIMITS ON OPTIMAL DESIGN OF
STEEL PORTAL. Journal of Constructional Steel Research.
2. Ghada El-Mahdy, Maged Tawfick Hanna. (2019). Sway and No-Sway Behaviour
of Pitched Roof Portal Frames Composed of Cold-Formed Steel Sections. The
British University in Egypt.
3. Joseph F. Neuber Jr., Chair ; Patrick J. Harrison, Vice Chair, Dennis C. Ahal.
(2015). Guide to Concrete Floor and Slab Construction. ACI University.
5. (March 27, 2013). Practical deflection limits for single storey buildings. NCCI.
B B
PROJECT 1 A3
C C
D D
E E
F F
G G
IPE 200
H H
J J
K SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
ISSUE MODIFICATION BY CHK APV DATE
PROJECT
SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm 6.0000
DRAWING TITLE
6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
Pl-2
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
R-5
1.00
Pl-2 Pl-2
R-4
R-2
R-6 ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
Pl-1 ITEM DESCRIPTION MATERIAL QTY. REMARKS
R-1 0.4000
B R-3 B
Br. 3 Br. 3
0.1600
PROJECT 1 A3
0.9000 E-2
Br. 3
E-3 Br. 3
C C
7.827
Br. 3 Br. 3
E-1
6.000
Br. 3 Br. 3
D D
E E
Pl-3
19.650
20.000
F F
Stiffener
40x40x8 mm Bolts and Anchorage Stiffener
100x100x12 mm
PL 250x780x20mm
0.040 0.040 S275 Bolts for Connections 0.050
PL 300x550x24mm
S275
Pl-1
0.5717 Washer F844
0.120 0.120
A307 Gr. B
0.550 0.130
0.780 0.780 0.0996
0.160
0.250 0.250
0.100 0.200
PL-1
E-1
J Area of plate t (20 mm) = 0.195 m2 0.027
0.134 J
0.250
5.9899 6.0000 0.080
0.068
0.0530
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A A
APEX SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
RAFTER 1 RAFTER 2 0.3554 ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
R-5
5.0785 ITEM DESCRIPTION MATERIAL QTY. REMARKS
B R-2 B
4.3938 0.3500 R-4
5.0168
R-6 PROJECT 1 A3
0.700 R-1 0.3500
R-3
0.3310
C 4.4074 5.0764 C
0.3260
4.3938 5.0189
D D
0.3260 R-4
0.6728 4.4084
0.2500
E R-1 E
0.2500
5.0785
R-5
0.2500
F F
4.3938
R-2
0.2500
5.0189
R-6
G G
4.4074 Plate ( t = 12 mm) Area = 4.1699 m2
R-3
J J
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm SQ. 7.5x7.5x0.4 cm
Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000
DRAWING TITLE
60.000
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A A
APEX SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
RAFTER
B B
PROJECT 2 A3
C C
4.0000
D D
8.0000
E E
4.0000
3.0000
F F
20.0000
G G
B - P6
H H
Br. 9 0.5798 Br. 9 Br. 9 0.5798 Br. 9
B - P6 B - P4
1.1000 1.1000
Br. 9 Br. 9 B - P6 Br. 9 B - P4 Br. 9 B - P5
IPE200
J 1.1000 1.1000 J
Tube100x75x3 mm Tube100x75x3 mm
Br. 9 Br. 9 Br. 9 Br. 9 B - P5
B - P4
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
6.0000 Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
0.2995
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
Br. 4
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
Br. 9 Br. 9
Br. 12 Br. 12
Br. 9 Br. 9
Post Post
Br. 12
Br. 9
ITEM DESCRIPTION MATERIAL QTY. REMARKS
Br. 9 Br. 2 Br. 2 Br. 9
Post Post
Br. 6 Br. 6
B Br. 9 Br. 7 Br. 6
Br. 12 Br. 12
PROJECT 2 A3
UPE 80 Br. 2 Br. 2 UPE 80
0.1015 0.1015
Br. 12 Br. 12
Br. 8 Post Post Br. 8
Post Post
Br. 3 Br. 3
Br. 2 Br. 2
0.1135 Br. 5 Br. 5 0.1135
Br. 1 Br. 1
Br. 3 Br. 3
6.0000 6.0000
Post Post
D D
Br. 1 Br. 1
3.1999 3.1999
E 19.6000 E
Br. 11 Br. 11
Br. 10 Br. 10
F F
SHS 70x3 mm
1.0000
G 2.9261 G
1.0000 IPE400
2.9261
POST
2.9261
H H
7.8383
J
IPE400 J
6.0000
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
0.2995
BASE PLATE (FIXED) FINISHED FLOOR LEVEL
L CLIENT PROJECT No. L
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A POSTS RAFTERS AND COLUMNS BARS SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
PLATES AND PARTS
Tube 100x100x3 mm
For Column Bracing For Rafter supporting Purlins ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
0.1500
L75x75x8 mm Post - P2 Post - P1 0.1500 0.1238
IPE400
ITEM DESCRIPTION
IF IN DOUBT - ASK
MATERIAL QTY. REMARKS
0.0965 0.0750
0.1700
0.0434
B 0.2000
0.0504 0.0803
0.1700
B
Br. 1 0.0817 Br. 9 0.1500 Post
BASE PLATE
6.5718
For Column side Rail
No. EACH FRAME:
L75x75x8 mm Br. 10 Ra. to Ra. : 8
D 0.1400
0.6997
D
No. EACH FRAME:
Br. 3 0.0750
0.0800
0.0080 Column : 16 0.0600
A307 Gr. B
E 0.0600 E
0.1001 0.1001
Br. 4
0.1001 0.1001
0.0250 6.5389
0.1001 0.1001 No. EACH FRAME:
Column : 2
0.8500
No. EACH FRAME:
0.2131 0.2131 BASE PLATE Ra. to Ra. : 4
Br. 11
F COLUMN BRACING - bar L75x75x8 mm
F
0.3000
t = 20 mm 0.0801 0.1397 0.0801
B - P3 0.0264
No. EACH FRAME: 0.2200 0.1396
0.0489
Co. to Ra. : 2
Ra. to Ra. : 6
0.1800
G Br. 5 G
1.0000 No. EACH FRAME:
Co. to Co. : 4
0.0797 0.0797
Front Rails - bar Tube100x75x3 mm
0.3746
1.1385 0.1200 0.0800
B - P4 0.0424
0.0100 0.0100
4.2470
For Column and Rafter Connections
Br. 6 Bolts and Anchorage
Bolts for Connections
1.0000 A307 Gr. B
J J
0.3241
A307 Gr. B A307 Gr. B Front Rails - bar
Washer F844 A307 Gr. B
Tube100x75x3 mm
STRUCTURAL DESIGN
0.9850 Dr Luay M. Al-Shather
B - P5
No. EACH FRAME:
0.0996
K
For Roof Bracing
An. 1 3.3827 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
0.0100 0.0998 0.1004 02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
0.0504
0.0452
01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
0.0387
ISSUE MODIFICATION BY CHK APV DATE
0.0775 0.1450 0.1385
Br. 7 0.2225
PROJECT
0.0100
0.1600 A307 Gr. A 80Ksi Front Rails - bar
No. EACH FRAME:
Rafters : 4 Washer F844
0.3000
L 0.0100
Tube100x75x3 mm CLIENT PROJECT No. L
For Roof Bracing
B - P6
0.0452
0.0502
0.0504 0.1600
0.0424
0.5699
0.0387
DRAWING TITLE
Br. 8
0.0725
0.1500 4.0970
0.1600
An. 2 DRAWN BY CHECKED BY APPROVED BY DRAWING No.
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 IPE400
6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
UPE 80 0.1238 Tube 100x100x3 mm 0.0587 REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A PL t = 12 mm
Tube 100x100x3 mm 0.1000 SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
0.1069 0.1700
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
19.6000 19.6000 19.6000
0.1500
Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br.
Br.44
Rafter 1
0.1800
ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
ITEM DESCRIPTION MATERIAL QTY. REMARKS
0.0046
Br. 4
0.0046
Br.
Br.44
PROJECT 2 A3
C 6.0000 6.0000 6.0000
C
D D
6.0000 6.0000 6.0000
E E
6.0000 6.0000 6.0000
F F
G G
POST LOCATION ON THE ROOF BRACING ON THE ROOF PURLINS LOCATION ON THE ROOF
Br. 4
0.0587
0.0200
Br. 9 0.1000
0.1001
Br. 12
Br. 9 0.0100
0.1001
0.0387
0.0387
t = 20 mm
0.3000 0.1500
4.7641
0.9850
0.0850 0.0850
0.3746
1.1385
L IPE400
CLIENT PROJECT No. L
0.1238 0.1238
0.1203
Br. 2 Br. 2 0.1203
0.1211
0.6392 0.5695 0.1158 DRAWING TITLE
1.1385
CUT TWO PARTS
0.9985 2.7503 1.0154 0.3746
M 4.7641 DRAWN BY
SCALE
CHECKED BY
DATE
APPROVED BY
SHEET SIZE
DRAWING No.
JOB No.
M
A3
14 15 16
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A 0.7002 A
SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
1 2 3 4 5 IPE400
6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
UPE 80 0.1238
Tube 100x100x3 mm 0.0587 REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A PL t = 12 mm
Tube 100x100x3 mm 0.1000 SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
0.1069 0.1700
0.1015 0.1238 0.1001
0.1700 0.1203
0.1001
Br. 13 Post
Post 0.1001
Br. 3
Br. 2 0.2131 ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
0.1135 0.1019 0.1500 0.1500
0.3730
IF IN DOUBT - ASK
Br. 1 0.2000
0.0965 0.0504
0.0857 ITEM DESCRIPTION MATERIAL QTY. REMARKS
t = 12 mm
B 0.0100
B
1.2000
Br. 1 0.3730
IPE400
Br. 2
Br. 3 0.0800
L 75x75x8 mm
Br. 2
PROJECT 2 A3
C
Br. 3 2.6082 Br. 3
2.4878 C
2.9260
Rafter 1
Br. 8 Br. 7
D D
0.1800
0.1238
Br. 3
0.1203
0.0600
0.6997
6.0000 6.0000
Post
0.0605 0.1895 0.2000 0.1895 0.0602
0.4000 0.2800
E E
0.0600
Br. 1
0.0250
Br. 3 Br. 2
Br. 10 6.0000
L75x75x8 mm
F F
0.1800
0.0135
0.1800
Br. 8 Br. 7
2.4999
IPE400 : MASS 66.30 KG/m
Rafter 1
G G
ROOF BRACING -
RAFTER 1
Br. 4
H H
Br. 11 Br. 9
Br. 12
Br. 9
Br. 10
Br. 9
COLUMN PARTS
Br. 2 Br. 8 Post
0.6292 Br. 9 Br. 6
J J
L75x75x8 mm Br. 9
Br. 4 STRUCTURAL DESIGN
Br. 7
Dr Luay M. Al-Shather
Br. 2
Mobile: +00964 (07822234399)
IPE400
2.7361 Luay.albothabhak@uokufa.edu.iq
Post
5.6910
L 0.0850
4.9686 0.0850 CLIENT PROJECT No. L
0.1203 0.1203
DRAWING TITLE
0.1211 0.1211
0.1158 0.1158
M
COLUMN BRACING
4.9686 SCALE DATE SHEET SIZE
A3
JOB No.
M
14 15 16
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A 0.7002 A
SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
1.0000 Br. 9
1.0000 Br. 9
Br. 12 Br. 12
1.0000 Br. 9
Br. 2 Br. 2
IF IN DOUBT - ASK
1.0000 Br. 4
Br. 9 Br. 2 Br. 2
Br. 4
1.0000 Br. 9
Br. 7 Br. 7
SHS 70x3 mm
ITEM DESCRIPTION MATERIAL QTY. REMARKS
1.0000 Br. 9
Br. 12
Br. 2
3.5834 3.5834
Br. 2
Br. 12
B 1.0000 Br. 9
Post Post
Br. 9
B
1.0000 Br. 9
Br. 2
Post Br. 6 Br. 6 Post
Br. 2 Br. 9
1.0000 Br. 9
Br. 7 Br. 7
Br. 9
PROJECT 3 A3
Br. 2 Br. 2
Br. 9
Br. 9
Br. 2
3.5834 IPE450 3.5834
Br. 2
Br. 9
Br. 9
Br. 8 Br. 8
Post Post
Br. 3
0.1135
Post
Br. 2
Br. 6
3.5834 3.5834 Br. 6
Post
Br. 2
Br. 3
0.1135
Br. 1 Br. 1
1.2000 1.2000
C Br. 2 Br. 2
C
Br. 3 Br. 3
7.7513
IPE450
Br. 3 Br. 3
D
Br. 1 Br. 1
E E
BASE PLATE (FIXED) FINISHED FLOOR LEVEL
Br. 10 Br. 10
24.5500
F 25.0000 F
0.0925
G G
6.1187
0.7797
1.0000 Br. 7
1.0000 Br. 9
1.6040
1.0000 Br. 9
Br. 12
0.0925
H H
1.0000 Br. 9
Br. 2
Post
3.5834
Br. 8
1.0000 Br. 9
Br. 2
Br. 7
0.3390
Br. 9
Br. 9
Br. 2
6.1187
Br. 8
J
Post
6.1187 J
Br. 6
0.7002 0.0925
6.1187 STRUCTURAL DESIGN
Dr Luay M. Al-Shather
1.0000 Br. 9 Br. 8
Mobile: +00964 (07822234399)
1.0000 Br. 9
Br. 12
0.5969 Luay.albothabhak@uokufa.edu.iq
1.0000 Br. 9
Br. 2
K 1.0000 Br. 9 Br. 8 Post
0.0925 03
02
PIPE SUPPORTS NOT ADDED
ERECTION MARKS NOT ADDED.
MP
MP
PH
PH
08.02.09
19.01.09
K
1.0000 Br. 9
Br. 9
Br. 2
Br. 7
3.5834 01
ISSUE
VALVE/REST PLATFORMS NOT ADDED
MODIFICATION
MP
BY
PH 22.12.08
CHK APV DATE
PROJECT
Br. 9
2.3575
Br. 2
Br. 7
6.1187
Post
2.0385 6.1187 0.8728
Br. 6
L CLIENT PROJECT No. L
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
0.0200
PROJECT 3 A3
Br. 2
0.1135
0.1001
Br. 1
1.2000
1.0001 1.0001
0.2131
C C
Br. 2
t = 20 mm
0.2131
Br. 3
D D
0.1800
Br. 4
0.0600
0.7497
E E
0.0605 0.2020 0.2250 0.2020 0.0602
Br. 3
0.4000 0.2800
6.0000
Post
F 0.0600 F
0.0250
Br. 1
H H
J 0.4500 J
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
0.4675 1.9113
L CLIENT PROJECT No. L
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
FOR INTERNAL USE ONLY
IR
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
RAFTER
ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
ITEM DESCRIPTION MATERIAL QTY. REMARKS
B APEX B
PROJECT 4 A3
C C
4.0000
D D
6.000
E 4.0000 E
3.250
F F
26.000
G G
Br. 9 Br. 9
Br. 9 Br. 9
Br. 2 Br. 2
Br. 8 Post Post Br. 8
Br. 9 Br. 9
Br. 9 Br. 9
Br. 7 Br. 7
Br. 9 Br. 2 Br. 2 Br. 9
Br. 12 Br. 12
Br. 9 Br. 9
Br. 9 Br. 9
Br. 7 Br. 7
Br. 2 Br. 2
Br. 9 Br. 9
Br. 9 Br. 9
Br. 2 Br. 2
Br. 8 Br. 8
Br. 2 Br. 2
Br. 6 Br. 6
Br. 1 Br. 1
Br. 2 Br. 2
J J
Br. 3 Br. 3
03 MP PH 08.02.09
Br. 3 Br. 2 Br. 2 Br. 3
DRAWING TITLE
26.0000
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A A
0.3549 0.3549 SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
2.2000
6.0000
B 0.0605 0.2020 0.2250 0.2020 0.0602
B
0.2800 1.2500
PROJECT 4 A3
0.0600
Stiffener
t = 12 mm
26.0000
C
0.2000 A307 Gr. A 80Ksi
C
0.0250
Br. 10
both way
1.2500 1.2500
0.6000 An. 2
0.1720
both way 12db ( 0.192 )
4.5000
D 0.3000 D
2.2000 2.2000
1.2500 1.2500
SUB-BASE 30 cm
sec. in footing
5.3806 5.3806 2.0000 2.0000 5.3806 5.3806
POSTS RAFTERS AND COLUMNS BARS
6.0000
E E
2.2000
Post
5.6354
No. EACH FRAME:
Co. to Co. : 4
Ra. to Ra. : 8
6.0000 ROOF BRACING BARS
F F
0.0800 B - P1
0.0296
2.2000 2.2000
1.2500 1.2500
6.5718
No. EACH FRAME:
Ra. to Ra. : 8
G 6.0000 0.0296 G
0.0503 B - P2
2.2000 2.2000
6.5389
1.2500 1.2500
1.2500 1.2500
No. EACH FRAME:
Co. to Co. : 4
2.2000 2.2000
1.2500 1.2500
Front Rails - bar
L Tube100x75x3 mm
CLIENT PROJECT No. L
B - P6
4.5000 0.0424
2.2000 2.2000
4.0970 DRAWING TITLE
1.2500 1.2500
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4
0.1500
Br. 4 Br.
Br.44
SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A A
0.3549 0.3549 SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
0.9999 0.9999
1.0000 Br. 9 Br. 9
1.0000
1.0000 Br. 9 Br. 12 Br. 12 Br. 9
1.0000
0.8755 1.0000 Br. 9
Br. 2
Br. 8 Post Post Br. 8
Br. 2
Br. 9
1.0000 0.8755
1.0000 Br. 9
Br. 9
Br. 2 Br. 2
Br. 9
Br. 9
1.0000 ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
1.0000 Br. 9
Br. 7 1.7730 1.7730 Br. 7
Br. 9
1.0000 ITEM DESCRIPTION MATERIAL QTY. REMARKS
1.0000 Br. 9
Br. 12
Br. 2 Br. 2
Br. 12
Br. 9
1.0000
1.0000 Br. 9
2.0385 5.5342 5.5342 2.0385
Br. 9
1.0000
B 1.0000 Br. 9 Post Br. 6 Br. 6 Post Br. 9
1.0000 B
1.0000 Br. 9 Br. 2 Br. 2 Br. 9
1.0000
1.0000 Br. 9 Br. 7 Br. 7 Br. 9
1.0000
PROJECT 2 A3
Br. 2 Br. 2
Br. 9 Br. 9
0.3390 Br. 9
Br. 2 Br. 2
Br. 9
0.3390
Br. 8 Br. 8
Br. 2 Br. 2
0.1135 0.1135
Br. 6 Br. 6
Br. 1 Br. 1
1.2000 1.2000
C Br. 2 Br. 2
C
Br. 3
7.9889 Br. 3
Br. 3 Br. 3
6.0000
D Br. 1 Br. 1
D
Br. 3 Br. 2 Br. 2 Br. 3
0.4500 0.4500
E E
Br. 10 Br. 10
26.0000
F F
Post
0.9996
1.0000
Br. 13
Br. 3 Br. 9
Br. 2
0.1135
1.0000 Br. 9 Br. 12
Br. 1
0.8755 1.0000 Br. 9
Br. 2
Br. 8
1.0000 Br. 9
G Br. 2
1.0000 Br. 9
Br. 7 1.7730 G
1.0000 Br. 9
Br. 12
Br. 2
Br. 3
1.0000 Br. 9
Br. 2
0.1000
0.1114
1.0000 Br. 9
Br. 2
Br. 7
0.3390
Br. 9
0.1001
Br. 9
Br. 2
0.1001
H Post
Br. 8
H
Br. 6 0.1001
1.0001 1.0001
Br. 3 0.2131
6.0000
Post
0.0250
J 0.0602
0.2131
t = 20 mm J
Br. 1
0.2020 0.0797
0.0100
0.0801
0.0800
STRUCTURAL DESIGN
0.0803
0.1500
0.1238 0.1700
0.7497 0.2250
Dr Luay M. Al-Shather
Mobile: +00964 (07822234399)
0.0797
0.0434
0.0100
0.3000
0.1397
0.0750
0.1700 0.0600
0.1200
0.2020
0.2800 0.0600
0.1396
Luay.albothabhak@uokufa.edu.iq
0.1385
0.0801 0.1720 0.1800
K 0.0605
0.2200
0.5200
0.5699
Br. 4 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
0.4000
02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
01 MP PH 22.12.08
0.0600
0.7497 ISSUE
VALVE/REST PLATFORMS NOT ADDED
MODIFICATION BY CHK APV DATE
PROJECT
0.1001 0.1001 0.1001 0.2131 0.2131 0.3241
0.1600
0.4500 0.0504
0.0504
0.1600
0.0605 0.2020 0.2250 0.2020 0.0602
0.4000
0.2225 0.1500 0.1500
0.0998
0.0502
0.0725 0.2800
0.0775
L 1.0000
1.1385
0.04520.0387
0.0100 0.0100
0.0100
0.04520.0387
CLIENT PROJECT No. L
0.0080
0.1114 0.1001 0.1001 0.1001 0.2131 0.2131
0.3730
0.0504 0.9850
1.0000
0.0100 0.1400 0.0800
0.1500
0.1800
0.0484 0.0857 0.0750
0.1000
0.0939
0.0965 0.0817
0.0250
Br. 10
0.3746
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A APEX SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4
0.1500
Br. 4 Br.
Br.44
SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
4.5000 4.5000
19.8000
19.6000
ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
Br. 4 Br. 4 Br. 4
IF IN DOUBT - ASK
Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4
Rafter 1
B B
6.0000 6.0000
L75x75x8 mm L75x75x8 mm
PROJECT 2 A3
0.1800
Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br.
Br.44
Rafter 1
0.0046 0.0046
C C
6.0000 6.0000 6.0000
45.0000
F F
G G
Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br. 4 Br.
Br.44
6.0000
4.5000 4.5000
H H
Tube 100x100x3 mm
Post - P2 Post - P1
J Post
J
5.6354
0.0264
0.0296
0.0489 STRUCTURAL DESIGN
2.9261 2.9261 2.9258 L75x75x8 mm Dr Luay M. Al-Shather
Br. 8 Br. 7 Br. 7 Br. 8
0.0503
Mobile: +00964 (07822234399)
L75x75x8 mm
Luay.albothabhak@uokufa.edu.iq
L75x75x8 mm
Br. 8 Br. 7
DRAWING TITLE
COLUMN BRACING - bar
DRAWN BY CHECKED BY APPROVED BY DRAWING No.
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A APEX SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
RAFTER
B B
PROJECT 5 A3
C C
4.0000
8.0000
D D
4.0000
3.0000
E E
1.000
1.000 Br. 9 Br. 9
1.000 Br. 9
Br. 12
Br. 9
1.000 Br. 9
Post Post
Br. 9
1.000 Br. 9
Post Post
Br. 9
Br. 9 Br. 9
Br. 9 Br. 9
Post Post
Br. 3 Br. 3
Br. 2 Br. 2
Br. 1 Br. 1
G G
1.200
Br. 2 Br. 2
Br. 3 Br. 3
Rail Block Rail Block
Br. 2 Br. 2
DETAIL DETAIL
A Stiffener t =1.2cm both side A
1.500
Br. 2 Br. 2
H 0.260
H
2Stiffener t =1.2cm 2Stiffener t =1.2cm
Post Post
Br. 3 Br. 3
8.000
J J
Br. 3 Br. 3
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
1.500 Br. 1 Br. 1
Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
Br. 2 Br. 2
Br. 2 Br. 2
Post Post
L 0.025 0.025
CLIENT PROJECT No. L
DRAWING TITLE
14.600
M
15.000 DRAWN BY CHECKED BY APPROVED BY DRAWING No.
M
SCALE DATE SHEET SIZE JOB No.
A3
14 15 16
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
B B
1.000 Br. 9
Post Post
Br. 9
1.000
A307 Gr. B
Br. 9 Br. 9
1.000
1.000
Br. 9
Br. 9 Br. 9
Br. 9
PROJECT 5 A3
Post Post
Br. 9 Br. 9
Br. 9 Br. 9
C 0.102
A307 Gr. B
Post Post A307 Gr. B
0.102 C
Br. 12 Br. 12
Post Post
Br. 3 Br. 3
Br. 2 Br. 2
Br. 1 Br. 1
1.200 0.050
Br. 2 Br. 2
D
Br. 3
CRANE BRIDGE - Capacity 5 Tons Br. 3
D
Br. 2
0.015 Br. 2
1.500 0.400
Br. 2 Br. 2
E 0.260 0.300 E
Post Post
Br. 3 Br. 3
Packer Shims
Bracket upper
1.500 Br. 2
ANGLE 4x4x0.5"
Locknut
flange
Br. 2
F
8.000 Rail Block
0.1900
F
Rail Girder IPE400 - S275 JR
Locknut
S275 JR
6.470
Bracket IPE450 - S275 JR
0.1905
DETAIL Stiffener t =1.2cm both side
A Stiffener t =1.2cm both side
G 1.500 G
Br. 1
Br. 2
0.4500 Br. 1
Br. 2
Br. 2 Br. 2
Post Post
Br. 3 Br. 3
1.987
J 0.025
0.025 0.025
0.025
J
Br. 10 Br. 10
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
Mobile: +00964 (07822234399)
14.600 Luay.albothabhak@uokufa.edu.iq
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1.120
1.520
X8 X8 X8 X8 X8 X8 X8
B3
B3
B3
1.120
PROJECT 6 A3
1.520 1.520
7.099
1.520 1.520
5.980 X8 X8 X8 X8 X8 X8 X8 X8 5.980
C C
2.940 2.940
C26 C25 C24 C23 C22 C21 C20 C19 C18 C17 C16 C15 C14 C13 C12 C11 C10
6.6123 6.6123 6.6123 6.6123 6.6123 6.6123 6.6123 6.6123 6.6123 6.6123 6.6123 6.6123 6.6123 6.6123 6.6123 5.5100
104.6945
D D
Pipe 120x60x3mm
m IPE 500m
Pipe 120x60x3mm IPE 500m m
m IPE 500m
0.405
m
0.405 IPE 500m m
IPE 500m
m 1.520
1.520 IPE 500m
IPE 600mm
1.120 X5 X6 X6 X5 1.120
IPE 600mm
X7 X7 1.120
IPE 600mm
1.520 1.520
E 1.520
10.481 7.099 E
IPE 220mm
IPE 220mm
IPE 220mm
IPE 220mm
IPE 220mm
IPE 220mm
IPE 220mm
IPE 600mm
IPE 220mm
IPE 600mm
9.0000
9.0000
1.520 1.520
1.520
5.980
X5 X5 X6 X6 5.980
X7 X7 5.980
2.940 2.940
2.940
F 9.9999
11.9999 42.0000
F
53.9999
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 5.0000
B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B2 0.405
Pipe (120x60x3)mm Pipe (120x60x3)mm Pipe (120x60x3)mm Pipe (120x60x3)mm Pipe (120x60x3)mm 1.520
G Purlins Purlins Purlins Purlins Purlins
G
W1 X3 W2 X3 W3 X3 W4 B1 W5 X3 W6 X3 W7 X3 W8 X4 1.120
Pipe (120x60x3)mm
Purlins Main
Pipe (120x60x3)mm
Purlins
1.520
9.0000
Door
1.520
X3 X3 X3 X3 6.0000
6x6m X3 X3 X3 X4 5.980
2.9750
2.940
C1 C2 C3 C4 C3 C4 C3 C5 C5 C4 C3 C4 C3 C4 C3 C6 C7
H 42.0000 6.0000 47.0000
H
95.0000
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
21.650 Mobile: +00964 (07822234399)
11.250 Luay.albothabhak@uokufa.edu.iq
1 17
L CLIENT PROJECT No. L
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
9.9999 9.9999
ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
4.9999 5.0000 4.9999 5.0000
2.00 2.00
ITEM DESCRIPTION MATERIAL QTY. REMARKS
1.25
B 1 1.50 1.50
1 B
0.95 1.25 0.95
5.0000 5.0000
12.316
2
0.60
2.00
1.50
0.95
2 PROJECT 6 A3
6.0000 6.0000
0.60
15.095 2.00
C 3 1.50
3 C
0.95
6.0000 6.0000
4 1.50 1.50
4
0.95 0.95
6.0001 6.0001
D 5 1.50 1.50
5 D
0.95 0.95
23.432
6 6
6.0000
0.60 6.0000
E 26.211 2.75
E
7 1.50
7
0.95
6.0000 6.0000
28.989
8 8
6.0000 6.0000
F F
31.768 2.75 2.75
9 1.50 1.50
9
0.95 0.95
6.0000 6.0000
95.0000 0.60 95.0000
0.60
34.547
10 10
G 6.0000 6.0000
G
37.326
11 11
6.0000 6.0000
40.105
12 12
H 0.60
H
6.0000 6.0000
13 1.50 1.50
13
0.95 0.95
45.663
6.0000 6.0000
3.663 2.00
14 1.50
14
J 0.95
J
6.0000 6.0000
48.442
6.442 2.75
STRUCTURAL DESIGN
15
0.95
1.50
15 Dr Luay M. Al-Shather
0.60 0.60
Mobile: +00964 (07822234399)
51.221 6.0000
0.60
6.0000
Luay.albothabhak@uokufa.edu.iq
9.221 42.0000
2.00 2.75
K 16 1.50 1.50
16 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
0.95 0.95
02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
5.9999 5.9999
5.9999 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 5.9999 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000 6.0000
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
5.000
1
5.510
X2
5.000
1
PROJECT 6 A3
C25 C6
2 2
X1 X1
6.612
6.000 6.000
C C
C24 C3
3 3
X1 X1
6.612
6.000 6.000
C23 C4
4 4
X1 X1
6.612
D 6.000 6.000 D
C22 C3
5 5
X1 X1
6.612
6.000 6.000
C21 C4
6 6
X1 X1
E 6.612 E
6.000 6.000
C20 C3
7 7
X1 X1
6.612
6.000 6.000
C19 C4
8 8
F X1 X1 X1 X1 X1 F
6.612
104.695
6.000 6.000
C18 C5
9 9
X1 X1 X1 X1 X1 X1
6.612
6.000 6.000
95.000 95.000
C17 C5
G 10 10 G
X1 X1
6.612
6.000 6.000
C16 C3
11 11
X1 X1
6.612
6.000 6.000
H 12
C15 C4
12 H
X1 X1
6.612
6.000 6.000
C14 C3
13 13
X1 X1
6.612
6.000 6.000
J C9 J
C13 C4
14 14
X1 X1
6.612
6.000 6.000
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
15
C12 C9 C3
15
Mobile: +00964 (07822234399)
6.612
X1 X1 Luay.albothabhak@uokufa.edu.iq
6.000 6.000
K 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
C11 C9 C2
16 16 01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
X1 X1 X1 X1 X1 X1 X1 X1 X1 ISSUE MODIFICATION BY CHK APV DATE
6.612
PROJECT
6.000 6.000
C10 C8 C1
17 17
6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000 6.000
L 6.000 6.000 CLIENT PROJECT No. L
12.000 42.000 12.000 42.000
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
B B
PROJECT 6 A3
C C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
0.619
D D
9.290
9.262
9.256
9.221
9.195
9.187
9.153
9.129
9.118
9.062
9.084
8.996
9.025
8.958
8.929
8.892
8.863
7.607
8.796
8.825
8.759
8.729
8.692
8.663
8.596
8.626
8.559
8.530
8.463
8.493
8.426
8.397
8.359
8.330
8.264
8.293
8.226
8.131
8.197
8.160
8.064
8.093
8.027
7.997
7.960
7.940
7.884
7.894
7.829
7.827
7.761
7.773
7.718
7.662
7.694
7.627
7.560
7.494
7.427
7.360
7.294
7.227
7.161
7.094
7.028
6.961
6.894
6.828
6.761
6.695
6.628
6.562
6.495
6.429
6.362
6.296
6.229
6.163
6.096
6.029
5.963
5.896
5.830
5.763
5.697
5.630
5.564
5.497
5.431
5.364
5.297
5.231
5.164
5.098
5.031
4.965
4.898
4.832
4.765
4.699
4.623
4.543
4.463
4.383
4.303
4.220
E E
5.371
F F
0.590
5.148
0.820
5.278
5.119
4.989
4.961
5.306
3.060
1.160
3.881
3.852
3.722
3.694
3.535
3.564
3.377
3.406
3.247
3.219
3.089
1.952
1.793
1.635
0.820
1.476
1.318
9.121
9.149
8.991
8.962
8.833
8.804
8.646
8.674
8.487
8.516
8.357
8.329
8.171
8.199
8.041
7.855
7.696
7.538
7.379
7.221
7.062
7.062
7.090
6.904
6.903
6.932
6.774
6.745
6.745
6.615
6.587
6.587
6.428
6.428
6.457
6.270
6.270
6.298
6.140
6.140
7.220
5.320
5.161
5.003
4.819
4.686
8.012
4.528
6.112
4.369
4.235
G G
3.160
3.160
3.160
3.160
1 17
H H
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
0.400 0.940
1.975
1.975
1.975
1.975
1.975
1.975
1.975
1.975
J J
3.015
6.135
6.135
6.135
STRUCTURAL DESIGN
3.160
3.160
3.160
3.160
3.160
3.160
3.160
3.160
Main
Door
Dr Luay M. Al-Shather
6x6m Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
Tube 120x60x3mm
R3 R2
R4 R1 ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
R5 ITEM DESCRIPTION MATERIAL QTY. REMARKS
B B
X5 X6 X5
7.099 X5
9.000 PROJECT 6 A3
X6
C C
C10 C31 C8 C30 C28 C29 C29 C28 C27 C1
17
12.000 42.000
54.000
D 70
D
60 9.000
8.921
65
65 47 47
60 86
1.050 1.050
PL t = 12 mm 5.649 0.50
0.50
S275 both side
66 26 69 68
60 60 71 67
1.15
22 1.15
1NO. Rafter IPE 500mm MKD R1
23 50
48 48
70 47
24 21 67
12.015
11.936 50 0.50
65
48 58
60 65
86 2.50 1.15
1.050 1.050 2.50
5.885 2.752 3.406
PL t = 12 mm 3.406
S275 both side
66 27 69 66 72
73 50
1NO. Rafter IPE 500mm MKD R2 48 50
25 70 50
67 49 1
11.936
12.015
9.00 2 3
9.00 9.00
3.406
11.285
3.406 3.406 3.406 65
2.50
86 65 49
1.050 1.050
3.406 3.406 3.406 3.406 PL t = 12 mm 5.649 48
3.931 51 51 51 51 51
S275 both side
66 26 69 68 51 51
71 67 48
0.25
1NO. Rafter IPE 500mm MKD R4 0.42 0.80 77 0.42
0.25 0.80 77 0.42 0.80 77 0.42
70
48 48 58 58 11.571 1NO. Column IPE 600mm MKD C1 1NO. Column IPE 600mm MKD C8 1NO. Column IPE 600mm MKD C10
62 63 62 63 62 11.491
63 63 63 65
0.255 0.255 0.255 0.255
65
0.25 0.25 0.25 0.25 0.25 86
1.050 1.050
PL t = 12 mm 5.651
1NO. Column IPE 220mm 1NO. Column IPE 220mm 2NO. Column IPE 220mm 2NO. Column IPE 220mm 1NO. Column IPE 220mm S275 both side 67 69
71 28 68
MKD C31 MKD C30 MKD C29 MKD C28 MKD C27
1NO. Rafter IPE 500mm MKD R5
F F
Tube 120x60x3mm
R8 R7
G R9 R6 G
R10
9.000
H 7.540 H
C11 C9 C2
16
42.000
9.221
J J
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
65
70 67
9.000
8.921
Mobile: +00964 (07822234399)
86
1.050
PL t = 12 mm
1.050
65 47
0.50
0.50
47
Luay.albothabhak@uokufa.edu.iq
S275 both side
66 29 69 68
71 67
1.15
1.15
2NO. Rafter IPE 500mm MKD R6
50 47
K 67 70
12.015
49
0.50
03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
11.936
65
65
50
1.15
02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
86
1.050
PL t = 12 mm
1.050
3.406
2.50
2.50 01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
S275 both side
66 30 69 66 72
73
1NO. Rafter IPE 500mm MKD R7 50
50 ISSUE MODIFICATION BY CHK APV DATE
70 50 4
67
11.936
12.015
9.00
1
9.00
2
9.00
2.50 PROJECT
65 52
65 49
86 52 49 56
1.050 1.050 2.50
2.50
PL t = 12 mm 7.540
S275 both side
66 30 69 66
73 72
PL t = 12 mm
S275 both side
1NO. Rafter IPE 500mm MKD R8
70 67
3.406
PL t = 12 mm 2.50 3.406
S275 both side
9.000 PL t = 12 mm
8.921 S275 both side
65
65
86 49
1.050 1.050
L 71
PL t = 12 mm
S275 both side
66 29 69 68 67
49
51 51 51 51 51 51
51
0.25
56
CLIENT PROJECT No. L
0.25
0.42 0.80 77 0.80 77 77
1NO. Rafter IPE 500mm MKD R9 0.42 0.42 0.80 0.42
67 70 1NO. Column IPE 600mm MKD C2 1NO. Column IPE 600mm MKD C11
3NO. Column IPE 600mm MKD C9
8.757
8.678
65
65
86
1.050 1.050
PL t = 12 mm
71
S275 both side
31 69 68 DRAWING TITLE
1NO. Rafter IPE 500mm MKD R10
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
R12 R12 Pipe 120x60x3mm
R13 R11
R14 ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
ITEM DESCRIPTION MATERIAL QTY. REMARKS
B B
D D
70 67
9.000
8.921
65
65 47
86
1.050 1.050
PL t = 12 mm 0.50 47
S275 both side 29 69 68
71 67
1.15 0.50
8NO. Rafter IPE 500mm MKD R11
50
49 1.15
70
12.015
11.936
65
E 86
1.050
65
1.050 2.50
50
5
E
3.406
PL t = 12 mm
S275 both side 30 69 72
73 50 2.75
7NO. Rafter IPE 500mm MKD R12
70 1
67 9.00
9.000
8.921
65
52 7.980
65 2.50
86 PL t = 12 mm
1.050 1.050 S275 both side
PL t = 12 mm
S275 both side
67 29 69 68 2.50
71 67 3.406
F 71
S275 both side 69 67 32 68
0.42
0.25
0.80 77 1NO. Column IPE 600mm MKD C12 F
6NO. Column IPE 600mm MKD C3
1NO. Rafter IPE 500mm MKD R14
Tube 120x60x3mm
R12 R12
G R15 R11 G
R16
H 9.000 H
8.420
C13 C9 C4 14
42.000
J J
45.663
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
PL t = 12 mm
1.050 1.15 0.50
ISSUE MODIFICATION BY CHK APV DATE
S275 both side 29 69 50 56
71 67 68 67 49 1.15
PROJECT
1NO. Rafter IPE 500mm MKD R15
70
50
3.130 2.50
3.051
65 3.406
6
3.406
65
86 2.50
1.050 1.050 50
1 8.420
33 9.00
3.406 PL t = 12 mm 3.406
S275 both side
49 DRAWING TITLE
51 51 56
51 51
0.25
0.25
0.42 0.80 77 0.80 77 0.42
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
Tube 120x60x3mm
R17 R12
R18 R11 ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
ITEM DESCRIPTION MATERIAL QTY. REMARKS
B B
PROJECT 6 A3
8.860 9.000
C C
C14 C3
13
0.884 42.000
42.884
D D
70
47
12.015
11.936 0.079
65 0.230 1.210 1.210 1.210 1.210 1.210 1.210 1.210 1.210 1.210 0.816
0.50
0.010 0.010
65
86 2.250 2.500
1.394
1.050 1.050
0.079
0.470 1.15
PL t = 12 mm
0.470
56
S275 both side 30 69 67 72
E 73
1NO. Rafter IPE 500mm MKD R17
50
E
70 7
9.895
65 0.343 1.210 1.210 1.210 1.210
9.816
1.210 1.210 1.210 1.003
0.079
3.406
2.50
86
0.018
4.730
6.395
1.395
0.010
65
2.500
1.050 1.050
0.079 3
0.450
PL t = 12 mm 0.470
2.50
3.406
F F
56 51
51
0.25
0.80 77 0.42
G G
R20 R11
H H
9.300 9.000
C15 12
J C4 J
40.105
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
3.406
A3
14 15 16
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
R22 R11 ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
ITEM DESCRIPTION MATERIAL QTY. REMARKS
B B
9.740 9.0000
PROJECT 6 A3
C C
C16 C3
11
37.326
D D
47
0.50
70
12.015
11.936 1.15
65
65
86
1.050 1.050
50 56
PL t = 12 mm
S275 both side 67 30 69 67 72 9
73
E 3.406
E
70 PL t = 12 mm
4.268 S275 both side
4.189
65 9.740
65
86 2.50
1.050 1.050 59
PL t = 12 mm
75
S275 both side 36 67
74
2.50
51
51
0.25
F 0.80 77 0.42
F
1NO. Column IPE 600mm MKD C16
R23
H H
10.180 9.0000
J C17 C5
10 J
K 47
03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
70
9.000 0.50 02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
8.921
65
65
47
1.15 01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
86
1.050
PL t = 12 mm
1.050 0.50
ISSUE MODIFICATION BY CHK APV DATE
S275 both side 29 69 68 67
71 66 1.15
50
50 PROJECT
2NO. Rafter IPE 500mm MKD R23 10 56
2.595
2.50
70
2.50
12.015
11.936
65 3.406
PL t = 12 mm
65
86 50 S275 both side
1.050 1.050
10.180
PL t = 12 mm 86
S275 both side 30 69 72
9.00 2.50
66 66
L 67 73
1NO. Rafter IPE 500mm MKD R24
59
CLIENT PROJECT No. L
2.50
70
13.441
13.362 PL t = 12 mm 2.50 3.406
65 S275 both side
86
65 DRAWING TITLE
1.050 1.050
PL t = 12 mm 66 67 37 67 69
67 73 S275 both side 72 51 56
51
1NO. Rafter IPE 500mm MKD R25 51 51
0.25
0.42 0.80 77 0.80 77 0.42
2NO. Column IPE 600mm MKD C5 1NO. Column IPE 600mm MKD C17 DRAWN BY CHECKED BY APPROVED BY DRAWING No.
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
B B
10.621
PROJECT 6 A3
9.0000
C C
C18 C5
9
17.021
D D
47
70
9.000 0.50
8.921
65
65
86 1.15
1.050 1.050
PL t = 12 mm
S275 both side 29 69 68 67
71 66
50
1NO. Rafter IPE 500mm MKD R26
11
E 2.50
56
E
70
12.015
11.936
65
65 PL t = 12 mm
86 S275 both side 3.406
1.050 1.050
PL t = 12 mm 2.75
S275 both side 66 30 69 66 72
67 73
1NO. Rafter IPE 500mm MKD R27
10.621
59
70
10.627
10.548
65
65 2.50
86
1.050 1.050 3.406
PL t = 12 mm 67 38 69
S275 both side 66 72
F 67 73
1NO. Rafter IPE 500mm MKD R28
67
F
51
51
0.25
0.80 77 0.42
R6
H
11.061 H
9.0000
J C19 C4
8 J
86
65 1.15 ISSUE MODIFICATION BY CHK APV DATE
1.050 1.050
PL t = 12 mm
S275 both side
67
66
30 69 66 72
PROJECT
67 73
1NO. Rafter IPE 500mm MKD R29 50
12
2.50
56
7.814
7.735
65
65
86 PL t = 12 mm
1.050 1.050 S275 both side
L 67 73
PL t = 12 mm
S275 both side 39 69 67 72 2.50
3.406
CLIENT PROJECT No. L
1NO. Rafter IPE 500mm MKD R30
59
11.061
56
51
51 DRAWN BY CHECKED BY APPROVED BY DRAWING No.
0.25
0.80 77 0.42
M 1NO. Column IPE 600mm MKD C19 SCALE DATE SHEET SIZE JOB No.
M
A3
14 15 16
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
R31 Pipe 120x60x3mm ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
R11
R11 ITEM DESCRIPTION MATERIAL QTY. REMARKS
B B
11.501
12.168 PROJECT 6 A3
9.0000
9.0000
C C
7 C22 C3 5
C20 C3 20.653
26.211
D D
47
0.50 47
0.50
1.15
1.15
70 50
67
12.015 13 70 50
11.936
65 11.360
2.50 11.281 15
65 65
86
1.050 1.050 65 2.50
86
1.050 1.050
PL t = 12 mm 56
S275 both side 30 69 72
73 67 67 PL t = 12 mm
S275 both side 42 69 72
1NO. Rafter IPE 500mm MKD R31 73 67 67
PL t = 12 mm
S275 both side 1NO. Rafter IPE 500mm MKD R35
56
E 2.50
3.406
PL t = 12 mm
S275 both side
E
2.50
70 40
5.000
4.921
65 11.501
3.406
65
86
1.050 1.050 59
PL t = 12 mm 2.50
S275 both side 69 72 12.168
73
2.50
59
1NO. Rafter IPE 500mm MKD R32
3.406
3.406
51 2.50
51
0.25
0.80 77 0.42
G R34 G
R33 Pipe 120x60x3mm
R36 Pipe 120x60x3mm
R11 R23
H 11.941 11.728 H
9.0000
9.0000
C21 C4
6 4
J C23 C4 J
23.432 17.874
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
47
0.50
47
K 1.15
03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
0.50
2.50 67
70 50 ISSUE MODIFICATION BY CHK APV DATE
PL t = 12 mm 8.546
30 69 72 8.467 16
73
S275 both side
2.50
3.406
82 81
80 79
1NO. Rafter IPE 500mm MKD R34
L 2.50 59
CLIENT PROJECT No. L
11.941 59
2.50
11.728
3.406
2.50
3.406 DRAWING TITLE
56
51
51
0.25 56
51
0.80 77 0.42 51
0.25
0.80 77 0.42
1NO. Column IPE 600mm MKD C21
DRAWN BY CHECKED BY APPROVED BY DRAWING No.
1NO. Column IPE 600mm MKD C23
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
Pipe 120x60x3mm ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
R38 IF IN DOUBT - ASK
Pipe 120x60x3mm
B B
11.288
10.848 9.0000
PROJECT 6 A3
9.0000
C C
C25
2
C6
C24 C3
3
15.095 12.316
D D
47
47
0.50
47 0.50
1.15
70 70
50 50
14.704
11.890
11.811 54 50
65 14.625 17 65
18
65 2.50 86 65 2.50
86 1.050 1.050
1.050 1.050
56
56 PL t = 12 mm
E 73
PL t = 12 mm
S275 both side
67
44
66
69 68
67 73
67 S275 both side 45 66 76
69 68 76 67
3.406
2.50
E
1NO. Rafter IPE 500mm MKD R37 PL t = 12 mm 50
S275 both side 1NO. Rafter IPE 500mm MKD R38 PL t = 12 mm
S275 both side
1 3.406
9.00
2.50 3.406
2.50
53
2.50
10.848
11.288
59
59
3.406
PL t = 12 mm
2.50 S275 both side
2.50
3.406
54
3.406
51
51
0.25
0.42 0.80 77
56
F 51
51 1NO. Column IPE 600mm MKD C6 51
51
0.25
F
0.25
0.80 77 0.42
0.80 77 0.42
0.020
0.020 0.400 0.020
0.070
0.020
0.100 0.050 0.150
0.560
0.300 0.250 0.150
0.800 0.050
32NO. Stiffener base plate for
1.157
0.100 Cutting 2x2cm 304NO. Stiffener base plate for 0.050 0.150 0.150 IPE 220 Column 10mm Thick. MKD 62
0.050
0.580 IPE 600 Column 16mm Thick. MKD 51 0.050
0.160 0.200
G Pipe 120x60x3mm
0.420
0.160
0.220
328NO. IPE 600 Column support
plate 12mm Thick. MKD 50
8NO. Base Plate 20mm Thick.
Connection with IPE220 MKD 61 G
R39 1NO. Stiffener plate for
0.050
0.270 0.455
0.250 0.258 0.984
0.190 0.040 0.470
0.020 0.090 Cutting 2x2cm
0.090 0.200
0.020 0.220 0.140 0.270 1.050 1.050
0.040
1.160
0.150 0.030 0.030 328NO. IPE 500 Rafter support
16NO. Stiffener base plate for 0.270 plate 12mm Thick. MKD 69 1NO. Stiffener plate for
8NO. Cap Plate 12mm Thick. 1NO. Stiffener plate for
IPE 220 Column 10mm Thick. MKD 63 IPE 500 Rafter 16mm Thick. MKD 80
Connection with IPE220 MKD 60 IPE 500 Rafter 10mm Thick. MKD 81
0.140
0.050 0.050
0.120
H
10.481 9.0000 0.300
0.200
0.300
0.200
0.080
0.140
0.080
0.100
0.150
0.090
0.988
H
0.040 1NO. Stiffener plate for
0.040 0.035 0.035 Apex connection12mm Thick. MKD 86
0.130 132NO. Stiffener end plate for IPE 500 Rafter 10mm Thick. MKD 80
66NO. Plate Thick. 16mm Beam (Eave Top) IPE 220 beam10mm Thick. MKD 83
IPE 600 and over gate connection MKD 82
2.500
0.466 2.500
2.950
5.0000 5.0000
3.108
0.487
J 2.470
2.615
J
0.159 23NO.Knee Connection Haunch MKD 71 0.485
9.9999
26NO.Knee Connection Haunch MKD 68
25NO.Knee Connection Haunch MKD 72
0.163
Dr Luay M. Al-Shather
Mobile: +00964 (07822234399)
0.012 2.470
3.108 0.159
2.950
0.159 0.018
0.500 0.025 0.485
0.500 0.466 0.466
Luay.albothabhak@uokufa.edu.iq
0.485
0.487
0.500 0.487 0.500
47 0.021
60 2.470 0.012 0.163 2.615
47 0.50
3.108 12NO.Knee Connection Haunch MKD 71 13NO.Knee Connection Haunch MKD 72
0.50
K 1.15
13NO.Knee Connection Haunch MKD 68
03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
1.15
70 78 78 78 56
50 50
02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
9.546 56 78
65
9.466
54
19
78 1.956
01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
65 20 54
86 2.50 78
1.050
4.636
1.050
2.250
0.012 1.853 0.091
0.076
2.460
2.226 0.159
ISSUE MODIFICATION BY CHK APV DATE
PL t = 12 mm
S275 both side
46 69 68 3.406
2.50
73 76 76 3.406 3.406
0.485
0.500 0.466
PROJECT
0.125 0.500 0.487
50 0.021
1NO. Rafter IPE 500mm MKD R39 9.226 9.208
PL t = 12 mm
S275 both side
3.406 2.225
59 1 1.865 0.091
9.00 2.384
28NO.Knee Connection Haunch MKD 73
64 64 0.125
59
64
64 2.75
75
2.50
53 64
10.481
64
53
0.011
74
0.147
IPE500 CUTTING 1.907
3.406
3.406 3.406
PL t = 12 mm
TO TWO HAUNCH PLATE 0.466
0.125
2.282
S275 both side 0.487
L 2.50
3.406
0.025
2.250
2.225 1.865 0.022
0.125 CLIENT PROJECT No. L
56 0.019 2.384
78 78 56 78
0.500
63 62 51 0.485 1NO.Knee Connection Haunch MKD 75
51 78 0.485
0.255 0.25
0.25 61 0.250 78
0.42 0.80 77 1NO.Knee Connection Haunch MKD 74
78 51 2.225 0.025
1NO. Column IPE 220mm 51 0.25
MKD C32 1NO. Column IPE 600mm MKD C7 0.80
77
0.42
14NO.Knee Connection Haunch MKD 73
Plate and Haunch Details DRAWING TITLE
1NO. Column IPE 600mm MKD C26
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
9.00
9.00
8.09 7.99
0.60 0.60
8.75 8.75
9.00 8.09
10.151 9.00 ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
4NO. IPE 600mm MKD 2
IF IN DOUBT - ASK
10.151
0.600
6.189 ITEM DESCRIPTION MATERIAL QTY. REMARKS
10.811
11.061
10.591 7.099
0.600
10.591
11.251
11.501
6.630
0.5m Strap 3mm Thick.
GUTTER
GUTTER
1.5mm
PROJECT 6 A3
0.600
7.290
11.031
7.540
C 11.691
Sandwich C
11.941
7.070
Tube 50x100x3 mm Panel 50 mm 180m Water Gutter 1.5mm Thick.
1NO. IPE 600mm MKD 14
0.600
7.730
11.258
7.980
7.510
0.600
11.918
12.168
Sandwich
7.510 Panel 50 mm
1NO. IPE 600mm MKD 15
0.600
10.818
8.420
D 0.600
11.478
7.950
0.220
0.010
0.025 0.220
0.100
folded plate 1.5mm
D
11.728 IPE500-S275
7.950 0.025
1NO. IPE 600mm MKD 16 A307 Grade A 0.270
60 Ksi
10.378
1NO. IPE 600mm MKD 7 0.130
Sandwich panel
9.938 0.173
Stiffener 150x90x12 mm
9.300 0.100 two side 0.300 0.300 0.140
0.090
0.080
0.130
1NO. IPE 600mm MKD 8 0.150
0.040 0.035 0.035
9.938
E 0.600
10.598
8.830
PL t = 12 mm -S275 E
10.848 both side
8.830
1NO. IPE 600mm MKD 18
0.600
9.571 9.490 All Rafter-Rafter
9.740 and Apex Connection Knee Connection
1NO. IPE 600mm MKD 9
9.571
9.270
0.600
10.231
10.481
9.270
0.20
1NO. IPE 600mm MKD 19
0.600
9.930
10.175
1.25
1NO. IPE 600mm MKD 10
9.00
F 8.09
2.595
9.711 F
0.60
8.75 3.00
6.015 1.25
9.00 9.711 brick wall
2NO. IPE 600mm MKD 86 0.600
10.371
10.621
0.30 0.30
0.60 0.60 0.60 0.60
0.60 LEAN CONCRETE 0.60
WELL COMPACTED C15 -100mm
SUB-BASE 300mm 0.60
WELL COMPACTED WELL COMPACTED
SUB-BASE 300mm 1.25 SUB-BASE 300mm
8.921 0.079
2.75
G 10.548 0.079
0.500
5.649
Tie Beam Details
2.00
G
0.190
0.500 0.079 8.921
9.000
0.079 10.548
10.627 2NO. IPE 500mm MKD 26 0.90 Tie
6db
Tie:
2.75 2.00
1NO. IPE 500mm MKD 38
11.936 0.079 0.52 0.4400
PL 1 t = 12 mm
0.079 11.936 WELDED WELDED S275
both side
0.500 12.015 0.600 0.600
PL 1
0.079 7.735
2NO. Rafter IPE 500mm MKD 27 1.50 0.52 1.50 0.52
7.814
0.95 PL 2
0.90 PL 1 PL 2
1NO. IPE 500mm MKD 39
11.491 0.079
0.30
0.500
0.190 5.651
Main Bars 0.95 0.95 Column Splice
0.079 0.60
H 0.500
4.921 0.079 11.491
11.571
0.500
RC PEDESTAL C35
2.108 0.079 0.079 8.921
9.000
0.500
77 61
0.079 2.108
2.187
16NO. IPE 500mm MKD 29 51 62
0.800
1NO. IPE 500mm MKD 41 0.400
11.281 0.079
0.500
63
0.079 11.936
BASE PLATE 800x420 mm BASE PLATE 800x420 mm 0.850
0.500 25mm Thick. Base Plate 1 Connection with IPE600 20mm Thick. Base Plate 2 Connection with IPE220 THICK 25 mm 0.450
12.015 THICK 25 mm
0.079 11.281 0.300
0.470
0.30 0.30
J 11.360 17NO. Rafter IPE 500mm MKD 30
J
1NO. IPE 500mm MKD 42
A307-GRADE A
0.60 0.60 38NO. 8mm Thick. plate for IPE600 base plate 8NO. 8mm Thick. plate for IPE220 base plate
Washer F844
8.678 0.079
8 mm Thick. plate for center Anchor bolt
0.500
0.900 0.600 WELL COMPACTED WELL COMPACTED
STRUCTURAL DESIGN
8.467 0.079 8.678 SUB-BASE 300mm SUB-BASE 300mm
0.079
8.757
0.500
3.130
K 0.079 14.625
14.704
3.051 0.079 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
0.500
0.079 3.051
02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
1NO. IPE 500mm MKD 44 3.130
0.500
9.816 0.079 PROJECT
0.500
0.079 11.811
11.890 0.079 9.816
9.895
7.002 0.079
L 0.079
0.190
9.466
4.636
7.082
CLIENT PROJECT No. L
9.546 1NO. IPE 500mm MKD 35
0.500
0.079 4.189
4.268 DRAWING TITLE
1NO. IPE 500mm MKD 36
13.362 0.079
0.500
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
7.670
A 3.835 3.835 0.270
0.135
SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
0.025 0.025 0.0594 5.956
0.0693 0.0693
0.140 0.1400
0.0323 0.0323
0.100 0.1187
0.220
0.050 0.050 0.1828
0.0436
32NO. Bracing plate 10mm Thick. 112NO. Bracing plate 10mm Thick.
88 NO. Roof bracing angle 100x100x8mm MKD X1 for X1 bracing angle MKD 66 for X1 bracing angle MKD 67
0.0601
ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
0.0700
0.0347
0.140
IF IN DOUBT - ASK
0.100 0.050 0.050 0.0394
4NO. Bracing plate 10mm Thick. ITEM DESCRIPTION MATERIAL QTY. REMARKS
2 NO. Roof bracing angle 100x100x8mm MKD X2 for X2 bracing angle MKD 76
4.956
B 6.900 0.220
B
0.135
3.450 3.450 0.270 0.0641
0.025 0.025 0.0641
0.0641
PROJECT 6 A3
0.140 0.140
0.0332 0.0332
0.100 0.050 0.050 0.1282 0.0450
0.0653
0.140 0.140 0.300
0.0326 0.0326
0.100 0.050 0.050 0.1297 0.0433 2 Stiffener t = 10 mm
0.1835
0.040
2NO. Bracing plate 10mm Thick. 12NO. Bracing plate 10mm Thick.
8 NO. Wall bracing angle 100x100x8mm side wall 54m MKD X5 for X5 bracing angle MKD 55 for X5 bracing angle MKD 48
83 83
0.025
3.450
6.900
3.450
0.025 0.270
0.0663
0.135
0.0655
16NO. Beam IPE 220mm MKD B1
0.0663
D D
0.140 0.140
0.0309 0.0309
0.100 0.050 0.050 0.1309 0.0437
0.1827
8 NO. Wall bracing angle 100x100x8mm side wall 54m MKD X6 4NO. Bracing plate 10mm Thick. 8NO. Bracing plate 10mm Thick.
for X6 bracing angle MKD 57 for X6 bracing angle MKD 58
5.830
85
82
0.135
2.915 2.915 0.270
0.025 0.025
82
0.0652
0.0660
0.0660
0.100
0.140
0.0345 0.0345
0.140
4.988
0.0391
0.050 0.050 0.1304
4.956
0.1918
0.200
PL t = 16 mm
4 NO. Wall bracing angle 100x100x8mm side wall 10m MKD X7 4NO. Bracing plate 10mm Thick. 8NO. Bracing plate 10mm Thick. IPE220
for X7 bracing angle MKD 64 for X7 bracing angle MKD 78
0.300
2 Stiffener t = 10 mm
0.040
7.670
83 83
0.135
3.835 3.835 0.270
0.025 0.025 0.0643
E 0.140
0.0318
0.0643
0.0318
0.0643
0.140
14NO. Bracing plate 10mm Thick. 32NO. Bracing plate 10mm Thick.
30 NO. Wall bracing angle 100x100x8mm side wall 104.6945m MKD X8 for X8 bracing angle MKD 59 for X8 bracing angle MKD 56
0.300
2 Stiffener t = 10 mm
0.040
F F
83 83
16NO. Beam IPE 220mm MKD B3
0.120
0.060
0.035 5.925
0.075
11.995
5.925 0.035
IPE 220 Main Beam Details
159NO. 120x60x3mm blue color Purlin pipe MKD P1
BILL OF QUANTITIES
G G
0.060
0.120
22NO.120x60x3mm red color Purlin pipe MKD P2 1 IPE 600X220 - S275 M 370
0.060
0.120 2 IPE 500X200 - S275 M 700
H
0.1225
0.075
5.925
6.1575
0.035
3 IPE 220X110 - S275 M 310 H
21 NO.120x60x3mm green color Purlin pipe MKD P3
0.125
0.060
0.080
0.080
14 SCREW M16X5CM PIECE 850
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
B B
PROJECT 7 A3
C C
D D
0.2000
IPE200
0.0160 0.2000
E E
0.0160
F F
0.1400 0.1400
0.1800
BOX1
0.4000 0.2800 IPE200
0.3000
Stiffener Plate t = 12 mm
THIS VALUE - OTHERWISE FOOTINGS SHOULD BE RE - DEIGN Stiffener Plate t = 12 mm
Plate t = 20 mm
G 0.4000 S275
0.3000
Plate t = 20 mm
S275
G
Plate t = 20 mm
Plate t = 20 mm
S275
S275
H H
J J
IPE200
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
F.L Anchorage
Stiffener Plate t = 12 mm
Plate t = 20 mm
F.L Anchorage
Stiffener Plate t = 12 mm
Plate t = 20 mm
Plate t = 16mm
S275
Mobile: +00964 (07822234399)
S275
S275
Epoxy Grouting
Epoxy Grouting
Luay.albothabhak@uokufa.edu.iq
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A 1 2 3 4 5 6 7 SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
F1 F1 F1
IF IN DOUBT - ASK
ITEM DESCRIPTION MATERIAL QTY. REMARKS
B B
5.000
B
F1 F1
PROJECT 7 A3
C 5.000 C
F1 F1
0.6000
5.000
D D
F1 F1
5.000
E 2.0000
E
F2
F1 F1
E 2.0000
40.000
5.000
F F
F1 F1
5.000
G F1 F1 G
G
5.000
F1 F1
H H H
5.000
F1 F1 F1
I
J J
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
0.1400 0.1400
FOUNDATIONS LAYOUT 2.0000 Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
0.2000 F2
Stiffener Plate t = 12 mm 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09
K BOX1
2.0000 K
0.0160 0.2000 0.2000 02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
0.0200
0.4000 0.2800 01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
F1 ISSUE MODIFICATION BY CHK APV DATE
0.0160 0.100 2.0000
0.0250 PROJECT
Stiffener Plate t = 12 mm 1.2500
Plate t = 20 mm
0.4000 S275
Plate t = 12 mm
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
B B
PROJECT 7 A3
C C
D D
E E
F F
IPE 180 IPE 180 IPE 180 IPE 180 IPE 180 IPE 180 IPE 180 IPE 180 IPE 180
1.0000
G G
5.0000
6.700
H H
1
5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000 5.0000
Number Length (m) Unit weight (kG/m) Bar weight (kG) Total weight (kG) Painting area (m2)
J J
Total per sections
BOX1_1 21 126.00 92.47 11651.85 11652 100.80 STRUCTURAL DESIGN
Dr Luay M. Al-Shather
IPE 180 112 560.16 18.81 10534.04 10534 390.96 Mobile: +00964 (07822234399)
IPE 200 120 777.36 22.37 17388.06 17388 597.17 Luay.albothabhak@uokufa.edu.iq
DRAWING TITLE
C30 Number Thickness (mm) Unit weight (kG/m2) Area (m2) Volume (m3) Total weight (kG)
RC Slab 1 169.39 423.70 520.00 88.08 220325 DRAWN BY CHECKED BY APPROVED BY DRAWING No.
M Total 520.00 88.08 220325 SCALE DATE SHEET SIZE JOB No.
M
A3
14 15 16
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7
ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
6.000
PROJECT 7 A3
5.000
C A
C
1 2 3 4 5 6 7
D D
SANDWICH PANEL 5 cm
1.000
1.2000
1.0000
6.000
E 4.8000 5.000 E
B
13.000 12.000 12.000 12.000 12.000
F F
1 2 3 4 5 6 7
SANDWICH PANEL 5 cm
1.000
1.2000
G G
1.0000
6.000
4.8000 5.000
H C H
13.000 12.000 12.000 12.000 12.000
1 2 3 4 5 6 7
J J
SANDWICH PANEL 5 cm
1.000
STRUCTURAL DESIGN
1.2000 Dr Luay M. Al-Shather
1.0000
Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
6.000
K 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
4.8000 5.000
02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
ISSUE MODIFICATION BY CHK APV DATE
PROJECT
D
13.000 12.000 12.000 12.000 12.000
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3
ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
ITEM DESCRIPTION MATERIAL QTY. REMARKS
PROJECT 7 A3
5.000
C TRUSS A C
B IPE 200
5.000
D D
TRUSS A
5.000
E E
TRUSS A
F 5.000 F
G G
5.000
TRUSS A
F
15
H H
5.000
TRUSS A 30 cm
G
J J
5.000
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
Mobile: +00964 (07822234399)
TRUSS A Luay.albothabhak@uokufa.edu.iq
K
H 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
12.8000 02
01
ERECTION MARKS NOT ADDED.
VALVE/REST PLATFORMS NOT ADDED
MP
MP
PH
PH
19.01.09
22.12.08
ISSUE MODIFICATION BY CHK APV DATE
12.000 PROJECT
5.000
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
0.40 PROJECT 8 A3
C
0.40 C
i
D 0.530 D
B
0.130
Cover
- 40 mm for non exposed to weather
- 50 mm for exposed to weather d
shrinkage Bar
both side for beam depth more
25 mm or 1.33 max. agg. size than 700 mm
use As (sh) = 0.08 As @ spacing RC SLAB 9 cm C25
Min. clear spacing large of : 300 mm
- 25 mm
E - bar diameter
- 1.33 of max. aggregate size
both way shear conn. E
As [ Tension reinforcement ]
Bar sizes should
not differ more than
two sizes
B
B AS longitudinal
0.40
H
G Ag concrete Ag concrete G
AS longitudinal
0.50
H H
J J
STRUCTURAL DESIGN
0.6011 0.6988 Dr Luay M. Al-Shather
DRAINAGE GATTER
Mobile: +00964 (07822234399)
DRAINAGE GATTER
Luay.albothabhak@uokufa.edu.iq
0.9000 0.8000
0.5000 0.6000
K PIPE 4"
03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
0.9905 02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
3.0000
01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
PIPE 4"
3.0000 3.0000
ISSUE MODIFICATION BY CHK APV DATE
PROJECT
5.0000
6.0000
3.0000
L 3.0000 3.0000 3.0000
CLIENT PROJECT No. L
DRAWING TITLE
6.9333 1.4667 4.0000 1.4667 6.9333
0.5634 1.0000 2.0000 2.6964 2.5973 1.4655 2.5777 2.9059 2.0004 2.1092
0.9057
21.000 20.8000
DRAWN BY CHECKED BY APPROVED BY DRAWING No.
FRONT VIEW OF STRUCTURE
M SCALE DATE SHEET SIZE JOB No.
M
BACK VIEW OF STRUCTURE
A3
14 15 16
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
0.9905 PROJECT 8 A3
PIPE 4"
3.0000 3.0000
C
SUNFACE MARKET C
NAJAF
6.0000
D D
E E
0.5634 1.0000 2.0000 2.6964 2.5973 1.4655 2.5777 2.9059 2.0004 2.1092
0.9057
21.000
F F
FRONT VIEW OF STRUCTURE
0.6011 0.6988
G DRAINAGE GATTER G
PIPE 4"
H 3.0000 H
J 5.0000 J
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
3.0000 Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
QC
JS
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
TUBE 10x10x0.3 cm
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A TUBE 10x5x0.2 cm SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
B B
A B C E A B C E A B C E
1 1 1 0.5000
4.0000 0.9000
4.0000
C
5.1660 5.1660 5.1660 0.5000
SUNFACE MARKET C
2 2
HP 8" HP 8" HP 8" HP 8"
2 NAJAF
4.9667 4.9667 4.9667
D D
HP 8" HP 8" HP 8" HP 8"
3 3 3
4 4 4
1.9000 1.1000
E E
1.1000 SUB GRADE
CONCRETE
4.9667 4.7726 4.9667 UNDER [W.C]
4.9667
THICK 20 CM
1.1000 REINFORCED
WITH BRC
1.7500
HP 8" HP 8" HP 8" HP 8"
5 5 5 1.7500
F F
HP 8" HP 8" HP 8" HP 8"
6 6 6
8 8 8
H H
HP 8" HP 8" HP 8" HP 8"
9 9 9
0.5000
10 10 10
J J
11 18
10
9
8
STRUCTURAL DESIGN
4.9667 7 4.9667 4.9667
6
5
4
3
2 HP 8" HP 8"
1.0000 Dr Luay M. Al-Shather
11
1
11 11
0.5000
Mobile: +00964 (07822234399)
1.8379 Luay.albothabhak@uokufa.edu.iq
4.9667
K 4.9667 4.9667 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
4.4639
0.8000
02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
HP 8" HP 8" 01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
12 12 ISSUE MODIFICATION BY CHK APV DATE
12
PROJECT
5.1200 5.1200
4.9667 4.9667 4.9667
PLAN +0.00
DRAWN BY CHECKED BY APPROVED BY DRAWING No.
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
TUBE 10x10x0.3 cm THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A TUBE 10x5x0.2 cm SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
B B
PROJECT 8 A3
C
SUNFACE MARKET C
NAJAF
D D
E E
IPE160
HP 8
IPE160
IPE160
F F
ISO VIEW
G G
4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 5.1660
4.9667
H H
3.0000
IPE200 IPE200 IPE200 IPE200 IPE200 IPE200 IPE200 IPE200 IPE200 IPE160 IPE160 IPE160
J J
3.0000
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
A Mobile: +00964 (07822234399)
5.1660 4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 4.9667 Luay.albothabhak@uokufa.edu.iq
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
TUBE 10 x5 x 0.2 cm SANDWICH PANEL 5 cm THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
TUBE 10 x10 x 0.3 cm
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A TUBE 10 x10 x 0.3 cm A
DRAINAGE GATTER
IPE240 IPE240 SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
0.8000
0.5000
IPE240
0.9905
PIPE 4" 3.0000 ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
IPE240 IPE240 ITEM DESCRIPTION MATERIAL QTY. REMARKS
B 6.0000
IPE160 5.0000 IPE160 B
3.0000
PROJECT 8 A3
1
12 6.9333 1.4667 4.0000 1.4667 6.9333
20.8000
C 21.000
AXES 1-1
20.8000
SUNFACE MARKET C
0.9905 0.9905
8.000
120x12 - 331
3.0000
300.000
6.0000 6.0000
E E
3.0000
11 10
6.9333 6.9333 6.9333
20.8000
21.000
F F
AXES 10-10
G
0.8000
0.5000 0.40 0.40 G
0.9905
CO PLATE
t=0.8 mm
PIPE 4"
purlin
H 3.0000
H
0.60
13 2.3700 2.0001 2.5633 6.9333 2.8334 2.0000 2.1000 BASE PLATE 35x35x2.0 cm
0.40 MAIN REINFORCEMENT
12 12 mm
RC PEDESTAL
J J
0.40 0.40
0.040
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
Mobile: +00964 (07822234399)
Six Anchorage Six Anchorage
Luay.albothabhak@uokufa.edu.iq
Concrete C25
K 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09 K
0.20 0.20 0.530
02
01
ERECTION MARKS NOT ADDED.
VALVE/REST PLATFORMS NOT ADDED
MP
MP
PH
PH
19.01.09
22.12.08
ISSUE MODIFICATION BY CHK APV DATE
PROJECT
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A A B C E SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
A B C E
20.8000
20.8000
TRUSS
6.9333 6.9333 6.9333
ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
6.9333 6.9333 6.9333
IPE240 IPE240 IF IN DOUBT - ASK
1
IPE240 IPE240 ITEM DESCRIPTION MATERIAL QTY. REMARKS
1
B B
5.1660
5.1660
2
IPE240
TRUSS
IPE240
PROJECT 8 A3
IPE240 IPE240
2
SUNFACE MARKET
4.9667
C TRUSS
C
4.9667
3
3
IPE240 IPE240 IPE240
NAJAF
4.9667
4.9667 TRUSS
D D
4
IPE240 IPE240 IPE240
4
4.9667
4.9667 TRUSS
5
IPE240 IPE240 IPE240
E 5 E
4.9667
4.9667 TRUSS
6
IPE240 IPE240 IPE240
6
F 4.9667 F
4.9667 TRUSS
7
IPE240
7
4.9667
4.9667 TRUSS
G G
8
IPE240
8
4.9667
4.9667 TRUSS
9
H IPE240 H
9
4.9667
4.9667
TRUSS
10
IPE240
10
J J
4.9667
4.9667
TRUSS
STRUCTURAL DESIGN
11 Dr Luay M. Al-Shather
11 Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
4.9667
4.9667
4.9667
TRUSS
DRAWING TITLE
BEAMS LAYOUT BEAMS LAYOUT 1ST
G.F ELEVATION .F ELEVATION +6.00
DRAWN BY CHECKED BY APPROVED BY DRAWING No.
M
+3.00 M
SCALE DATE SHEET SIZE JOB No.
A3
14 15 16
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
A B C D E F REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A 20.0000 SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
4.0098 4.1587 3.6630 4.1587 4.0098
B B
Hole 22 mm
TAPERED COLUMN
0.2000 0.3000
Base Plate
t = 20 mm
12@200 mm
0.6000
PROJECT 9 A3
0.9000 0.1323 0.1355 0.1323
0.0500
An.1
12@150 mm
0.5000
6.0000
C C
Hole 22 mm
0.25000.1500
IPE160 COLUMN
Base Plate
t = 16 mm
1.8000
0.1000 0.1000
0.9000 0.3000
0.0500
6.0000
D D
0.1000 0.1000
E 6.0000
1.2000 E
0.5200
An.1
An. 1
0.1385
F 12@150 mm F
6.0000
0.9000 1.8000
60.0000
G G
6.0000
A B C D E F
H H
6.0000
J 6.0000 J
6.0000
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
20.0000
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
PROJECT 9 A3
C C
7.9995
7.9995
2.6208
2.6208
D D
0.6000 0.6000
0.6000 0.6000
1.8000 1.8000
20.0000
1.8000 1.8000
20.0000
A B C D E F A B C D E F
E 4.0098 4.1587 3.6630 4.1587 4.0098 4.0098 4.1587 3.6630 4.1587 4.0098 E
POST 7.5x7.5x0.3 cm
1.5314
POST 7.5x7.5x0.3 cm
F IPE 160
F
7.9995
1.5328
2.9200
2.6208 2.6208
G G
H H
A B C D E F A B C D E F
4.0098 4.1587 3.6630 4.1587 4.0098 4.0098 4.1587 3.6630 4.1587 4.0098
J J
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
7.9995 7.9995 Mobile: +00964 (07822234399)
Luay.albothabhak@uokufa.edu.iq
DRAWING TITLE
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
THIS DRAWING IS COPYRIGHT AND IS ISSUED ON CONDITION THAT IT IS NOT COPIED,
REPRODUCED OR DISCLOSED TO A THIRD PARTY WITHOUT THE CONSENT IN WRITING OF
A SOIL INVESTIGATION SHOULD BE FOUND FOR ANY STRUCTURAL DESIGN - OTHERWISE FOUNDATIONS SHOULD BE RE-DESIGN
A
A B C D E F A B C D E F
4.0098 4.1587 3.6630 4.1587 4.0098 4.0098 4.1587 3.6630 4.1587 4.0098
ALL DIMENSIONS IN METERS UNLESS STATED OTHERWISE - DO NOT SCALE
IF IN DOUBT - ASK
ITEM DESCRIPTION MATERIAL QTY. REMARKS
B B
POST 7.5x7.5x0.3 cm
POST 7.5x7.5x0.3 cm
1.5314
PROJECT 9 A3
IPE 160
7.9995
1.5328
C 6.0000 C
IPE 160 IPE 160
2.9200
2.6208 2.6208
1.8000 1.8000
D 20.0000
1.8000 0.9000 0.9000
20.0000
0.9000 0.9000 1.8000
D
E 0.0160
0.1002
E
0.0160
0.1001
0.1002
0.4500
0.1001 0.1298
0.0160 0.2642
0.4500 0.1298 0.1002 0.1199
0.1199
0.0160
0.1002
R0.1000
0.1001 0.1802
1.0222 0.4500
0.1298 Rafter Part 3
0.1199 0.0160
0.1002
0.2824
0.6263 0.1001 0.4000
0.1298
0.4500
F 0.1802
R0.1000
0.1199
F
Rafter Part 2
0.0160
0.1002 0.3028
0.1001
0.4000
0.1298
0.4500
Rafter Part 1
0.1199
G G
0.1150
0.1150
0.4781
0.1580 0.2200
H H
0.2155
0.1002
0.1001 0.5200
2.0000
0.4500
0.1298
Bolt 20 mm
2.0000
Hole 22 mm 0.1199 A307
0.1385
0.0300
J J
3.0572
1.2000
STRUCTURAL DESIGN
Dr Luay M. Al-Shather
6.0000 6.0000
Mobile: +00964 (07822234399)
5.5710
Luay.albothabhak@uokufa.edu.iq
5.5707
6.0000
2.0000 03 PIPE SUPPORTS NOT ADDED MP PH 08.02.09
K K
02 ERECTION MARKS NOT ADDED. MP PH 19.01.09
01 VALVE/REST PLATFORMS NOT ADDED MP PH 22.12.08
ISSUE MODIFICATION BY CHK APV DATE
PROJECT
2.2673
L 2.5698 1.5064 CLIENT PROJECT No. L
Hole 22 mm
TAPERED COLUMN
0.320
Base Plate
t = 20 mm DRAWING TITLE
0.3000
0.5000
0.3000
0.3097 An.1
Web Plate Back Flange Front Flange DRAWN BY CHECKED BY APPROVED BY DRAWING No.
0.2200 Plate Plate
0.2200 EAVE Part 1,2,3
M SCALE DATE SHEET SIZE JOB No.
M
A3
14 15 16
Elast
Foam
IMcW
Buff
Proj
Fab
WH
SP
JS
QC
IR
FOR INTERNAL USE ONLY
BOOK
Structural engineers began to design more
and more standard-size offerings to meet
demand and soon pre-fabrication was no
longer possible. At this time, still well before
the computer age, the process came to be
known as the “pre-engineered” metal
buildings industry. Today, the metal building
industry boasts a capability of producing
buildings for virtually any low-rise, non-
residential end use. These building designs
are performed quickly by industry engineers,
who have vast knowledge of the building
codes utilized in the United States. The
custom design practice allows for economy in