Professional Documents
Culture Documents
SuperLine
SuperLine Product / Manual Catalog
Product / Manual Catalog 2018
SPMC-1805[Rev.0]
In vivo test
4 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 5
D
F
E
· Long hex design: Improved recognition
B
Improved wall thickness A Platform Diameter(Ø) 3.6 4.0 4.4 4.9 6.0 7.0
7 FX 40 07 SW 07 08 10 12 14 CS36
0.1 0.1 0.1 0.1
1.5
FX4510SW
8 FX 40 08 SW
Ø 4.0 Ø 4.0 10 FX 40 10 SW
12 FX 40 12 SW
14 FX 40 14 SW
7 FX 45 07 SW 07 08 10 12 14
0.3 0.3 0.3 0.3
1.5
※Hex driver: Use no more than 5N·cm of torque when screwing a cover screw to a fixture.
8 FX 45 08 SW
If hex is worn, slot on the head of the product can be used to rotate it.
Ø 4.4 Ø 4.5 10 FX 45 10 SW
12 FX 45 12 SW
14 FX 45 14 SW
7
8
FX 50 07 SW
FX 50 08 SW
07
1.5
08
0.4
10
0.4
12
0.4
14
0.4 GBR Healing Abutment
Ø 4.9 Ø 5.0 10 FX 50 10 SW Unit: mm, Scale 1.5 : 1
12 FX 50 12 SW
14 FX 50 14 SW
07 08 10 12 Ø 3.3
7 FX 70 07 SW 1.5 1.0 1.0 1.0
Ø 2.0
Ø 3.8
8 FX 70 08 SW Ø 3.8
Ø 7.0 Ø 5.8 GBHAB3820 3.5
10 FX 70 10 SW 2.0
FX4510SW 0.5
12 FX 70 12 SW
※Hex driver: Use no more than 10N·cm of torque when screwing a healing abutment to a fixture.
※ Note: To prevent damage to the Implant driver or fixture, do not over torque during fixture insertion. If hex is worn, slot on the head of the product can be used to rotate it.
8 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 9
Diameter Ø 4.5
Diameter G/H H Art. No.
5.0
3.5 3.0
2.0
5.0
3.5 3.0
2.0 3.5 HAB 85 20 35 E 2.0
Ø 8.5
HAB453050E 3.0 5.0 HAB 85 30 50 E
FX4510SW
5.0
Diameter G/H H Art. No. 2.0 3.5 HAB 95 20 35 E 2.0
3.5 3.0
Ø 9.5
7.0
3.0 5.0 HAB 95 30 50 E
2.0 2.0 HAB 40 20 20 E 3.5 3.0
5.0 4.0
2.0 2.0
2.0 3.5 HAB 40 20 35 E
Ø 4.0
3.0 5.0 HAB 40 30 50 E
4.0 7.0 HAB 40 40 70 E
7.0
2.0 2.0 HAB 45 20 20 E 3.5 3.0
5.0 4.0
2.0 2.0
2.0 3.5 HAB 45 20 35 E
Ø 4.5
3.0 5.0 HAB 45 30 50 E
4.0 7.0 HAB 45 40 70 E
7.0
2.0 2.0 HAB 55 20 20 E 3.5 3.0
5.0 4.0
2.0 2.0
2.0 3.5 HAB 55 20 35 E
Ø 5.5
3.0 5.0 HAB 55 30 50 E
4.0 7.0 HAB 55 40 70 E
7.0
2.0 2.0 HAB 65 20 20 E 3.5 3.0
5.0 4.0
2.0 2.0
2.0 3.5 HAB 65 20 35 E
Ø 6.5
3.0 5.0 HAB 65 30 50 E
4.0 7.0 HAB 65 40 70 E
※Hex driver: Use no more than 10N·cm of torque when screwing a healing abutment to a fixture. ※Hex driver: Use no more than 10N·cm of torque when screwing a healing abutment to a fixture.
If hex is worn, slot on the head of the product can be used to rotate it. If hex is worn, slot on the head of the product can be used to rotate it.
10 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 11
Hex Non-hex
Page 16 Page 16
Analog Analog
Long Short
Ø 4.5 / Ø 5.5 / Ø 6.5 Ø 4.5 / Ø 5.5 / Ø 6.5
Modification
※Hex driver: Use no more than 10N·cm of torque when screwing a healing abutment to a fixture.
If hex is worn, slot on the head of the product can be used to rotate it.
Cemented Restoration
12 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 13
1.5 1.5
4.0 4.0
CAB5535E DAB5535HE
FX4510SW FX4510SW
Diameter G/H Type Art. No. Type Art. No. Diameter G/H Art. No.
4.0 4.0
4.0 4.0
1.0 CAB 45 10 SE CAB 45 10 E 4.0 4.0
3.5 4.5 5.5 1.0 DAB 45 10 HE
1.0 1.5 2.5
1.5 CAB 45 15 SE CAB 45 15 E 1.5 DAB 45 15 HE 5.5
5.5
5.5
5.5
2.5 CAB 45 25 SE CAB 45 25 E 2.5 DAB 45 25 HE 5.5 5.5
Ø 4.5 Short Long 5.5
Ø 4.5 2.5 3.5 4.5 5.5
3.5 CAB 45 35 SE CAB 45 35 E 5.5 5.5 3.5 DAB 45 35 HE 1.0 1.5
5.5
5.5 5.5
4.5 CAB 45 45 SE CAB 45 45 E 3.5 4.5 5.5 4.5 DAB 45 45 HE
1.0 1.5 2.5
1.5 DAB 55 15 HE
5.5
4.0 4.0 4.0 2.5 DAB 55 25 HE 5.5
5.5
4.0 5.5
4.0
1.5 CAB 55 15 SE CAB 55 15 E 1.5 2.5 3.5 4.5 5.5 Ø 5.5 3.5 DAB 55 35 HE 5.5
5.5
3.5 4.5
2.5
2.5 CAB 55 25 SE CAB 55 25 E 4.5 DAB 55 45 HE 1.5
※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the combi abutment with fixture. ※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the dual abutment with fixture.
14 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 15
Diameter Ø 5.5
Ø 6.5 CCC 65 CS
Ø 4.5 CCC 45 C Ø 4.5 Ø 5.5 Ø 6.5
Long Ø 5.5 CCC 55 C
6.8
Ø 6.5 CCC 65 C
DAB5535NE
FX4510SW
Impression Coping
Diameter Art. No.
Diameter G/H Art. No.
Ø 4.5 Ø 5.5 Ø 6.5
Ø 4.5 CIC 45 L
1.0 DAB 45 10 NE
Ø 5.5 CIC 55 L 10.4
1.5 DAB 45 15 NE 5.5
5.5
5.5
5.5
Ø 6.5 CIC 65 L
2.5 DAB 45 25 NE 5.5 5.5
Ø 4.5 2.5 3.5 4.5 5.5
3.5 DAB 45 35 NE 1.0 1.5
4.5 DAB 45 45 NE
5.5 DAB 45 55 NE
Lab Analog
Ø 4.5 Ø 5.5 Ø 6.5
Type Diameter Art. No.
1.5 DAB 55 15 NE 4.0
Ø 6.5 CBC 65 SL
Ø 4.5 CBC 45 BL
Bridge Ø 5.5 CBC 55 BL
12.8
Ø 6.5 CBC 65 BL
※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the dual abutment with fixture.
16 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 17
Hex Non-hex
Hex Non-hex
Page 19 Page 20
Impression Coping Pick-up Impression Coping Transfer
Open tray technique (Complicated case) Closed tray technique (Simple case)
Ø 4.0 / Ø 4.5 / Ø 5.5 / Ø 6.5 Ø 4.0 / Ø 4.5 / Ø 5.5 / Ø 6.5
Page 19, 20
Analog
Ø 4.5
Combi & Dual Abutment
Lab. Components
Art. No
Comfort Cap Impression Coping Analog Burn-out Cylinder
XSDAB 45 S CCC 45 CS CAN 45 SL
CIC 45 L CBC 45 SL CBC 45 BL Page 14, 15 Page 21 Page 26 Page 26
XSDAB 45 CCC 45 C CAN 45 LL
Dual Custom Direct-Casting Metal-Casting
XSDAB 55 S CCC 55 CS CAN 55 SL Abutment Abutment Abutment Abutment
CIC 55 L CBC 55 SL CBC 55 BL
XSDAB 55 CCC 55 C CAN 55 LL Hex / Non-hex Hex / Non-hex Hex / Non-hex Hex / Non-hex
Ø 4.5 / Ø 5.5 / Ø 6.5 Ø 4.5 / Ø 5.5 Ø 4.5 Ø 4.5
XSDAB 65 S CCC 65 CS CAN 65 SL
CIC 65 L CBC 65 SL CBC 65 BL
XSDAB 65 CCC 65 C CAN 65 LL
Page 22, 23 Page 24, 25 Page 27 Page 27
Milling Angled Ti-Temporary Plastic
Abutment Abutment Abutment Temporary
Hex / Non-hex Hex / Non-hex Hex / Non-hex Abutment
Ø 4.0 / Ø 4.5 / 15° / 25° Ø 4.5 Hex / Non-hex
Ø 5.5 / Ø 6.5 / Ø 7.5 Ø 4.5 / Ø 5.5 Ø 4.5 / Ø 5.5 / Ø 6.5
Modification Modification
21.0 21.0
Short Hex DPU 45 11 HE 17.0 17.0 Short Hex DTF 45 11 HE
15.0 15.0
11.0 11.0
Short Non-hex DPU 45 11 NE Short Non-hex DTF 45 11 NE
Ø 4.5 Ø 4.5
Long Hex DPU 45 15 HE Long Hex DTF 45 15 HE
Long Non-hex DPU 45 15 NE Long Non-hex DTF 45 15 NE
Hex Non-hex Hex Non-hex Hex Non-hex Hex Non-hex
21.0 21.0
Short Hex DPU 55 11 HE 17.0 17.0 Short Hex DTF 55 11 HE
15.0 15.0
11.0 11.0
Short Non-hex DPU 55 11 NE Short Non-hex DTF 55 11 NE
Ø 5.5 Ø 5.5
Long Hex DPU 55 15 HE Long Hex DTF 55 15 HE
Long Non-hex DPU 55 15 NE Long Non-hex DTF 55 15 NE
Hex Non-hex Hex Non-hex Hex Non-hex Hex Non-hex
21.0 21.0
Short Hex DPU 65 11 HE 17.0 17.0 Short Hex DTF 65 11 HE
15.0 15.0
11.0 11.0
Short Non-hex DPU 65 11 NE Short Non-hex DTF 65 11 NE
Ø 6.5 Ø 6.5
Long Hex DPU 65 15 HE Long Hex DTF 65 15 HE
Long Non-hex DPU 65 15 NE Long Non-hex DTF 65 15 NE
Hex Non-hex Hex Non-hex Hex Non-hex Hex Non-hex
Diameter Ø 5.5
Diameter Ø 5.5 Top view
Ø 4.5
5.5
12.0
G/H 1.0
Ø 5.5
G/H 1.5
CDAB5510HE
FX4510SW
MAB55157HE
FX4510SW
Hex Non-hex
1.0 Hex CDAB 55 10 HE
1.0 Non-hex CDAB 55 10 NE
Ø 5.5 1.0 1.0 2.0 2.0 Diameter G/H Type Art. No.
2.0 Hex CDAB 55 20 HE
2.0 Non-hex CDAB 55 20 NE 1.5 Hex MAB 45 156 HE
Hex Non-hex Hex Non-hex Ø 4.5
1.5 Non-hex MAB 45 156 NE
1.5 1.5
Hex Non-hex
※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the custom abutment with fixture. ※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the milling abutment with fixture.
22 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 23
15°
Diameter G/H Type Art. No.
3.5 3.5
※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the milling abutment with fixture. ※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the angled abutment with fixture.
24 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 25
25°
Gold
Diameter G/H Type Art. No.
12.0
Hex RAB 45 GH
G/H 1.5 Ø 4.5 1.0
Non-hex RAB 45 GN
4.5
G/H 1.0
AAB254515HE
FX4510SW
1.0 1.0
RAB45GH
FX4510SW Hex Non-hex
Ø 4.5
2.5
2.5
Hex
Non-hex
AAB 25 45 25 HE
AAB 25 45 25 NE 1.5 1.5 2.5 2.5 3.5 3.5
Metal-Casting Abutment
3.5 Hex AAB 25 45 35 HE Unit: mm, Scale 1.5 : 1
Hex Non-hex Hex Non-hex Hex Non-hex
3.5 Non-hex AAB 25 45 35 NE • Abutment screw is included.
Diameter Ø 4.5
1.0 1.0
RAB45CLH
FX4510SW Hex Non-hex
※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the angled abutment with fixture. ※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the direct casting/metal casting abutment with fixture.
26 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 27
Screw Abutment
Diameter Ø 4.5
TAB45HG
Page 31 Page 31
FX4510SW Hex Non-hex
Impression Impression
Coping Pick-up Coping Transfer
Single / Bridge Single / Bridge
Ø 4.5 / Ø 5.5 / Ø 6.5 Ø 4.5 / Ø 5.5 / Ø 6.5
Page 32
Page 32
Ti-Retaining
Screw
2.0 2.0
※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten Hex Non-hex Screw-Retained Restoration
the temporary abutment with fixture.
28 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 29
Diam
eter
Ø 5.
Diameter Ø 5.5 5
20°
G/H 3.5
G/H 2.0
※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the screw abutment with fixture. ※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the angled screw abutment with fixture.
30 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 31
Single Hex STF 55 SL Single (Hex) Bridge (Non-hex) Ti-Retaining Screw Ø 2.3
Ø 5.5
Bridge Non-hex STF 55 BL Diameter L Art. No. 5.0
Ø 5.5 Ø 5.5
Ø 2.3 5.0 SRS 18 T Ø 1.8
0.8 0.8
Overdenture Procedure
Ti-Temporary Cylinder
Diameter Type Art. No. Positioner / Mini Ball / Magnetic Attachment
Ø 4.5 Ø 5.5
Single Hex STC 45 SG
Ø 4.5
Bridge Non-hex STC 45 BG 8.7 8.7
Gold Cylinder
Abutment Level
Diameter Type Art. No.
Ø 4.5 Ø 5.5 Impression
Single Hex SGC 45 SL
Ø 4.5
Bridge Non-hex SGC 45 BL Page 35 Page 37
12.0 12.0
Single Hex SGC 55 SL Positioner Mini Ball
Ø 5.5 Impression Impression
Bridge Non-hex SGC 55 BL
Coping Coping
Ø 4.5 Ø 3.5
Burn-out Cylinder
Diameter Type Art. No. Page 36 Page 37
Ø 4.5 Ø 5.5 Positioner Mini Ball Page 38, 39
Single Hex SBC 45 SL
Ø 4.5 Socket Female Socket / Magnetic Assay
Bridge Non-hex SBC 45 BL Metal / Plastic O-ring Dome type / Flat type
12.0 12.0
Ø 4.05 / Ø 4.85 Ø 4.5 / Ø 5.5
Single Hex SBC 55 SL
Ø 5.5
Bridge Non-hex SBC 55 BL
Positioner Positioner
Unit: mm, Scale 1.5 : 1 Unit: mm, Scale 1.5 : 1
Positioner Abutment
Diameter G/H Art. No. Positioner Abutment
3.0 4.0
1.0 2.0
1.0 PAB 35 10 Type Application Art. No.
2.0 PAB 35 20 Blue 1,000gf MSHP Tilting Type
3.0 PAB 35 30 Tilting Orange 500gf MSMP
type
Ø 3.5 4.0 PAB 35 40 Ivory 300gf MSLP Retention Force 100gf 300gf 500gf 1,000gf
±10°
5.0 PAB 35 50 5.0 6.0 7.0
White 100gf MSOP
6.0 PAB 35 60
Blue 1,000gf MSHPN
7.0 PAB 35 70 Non
Non Tilting Type
tilting Orange 500gf MSMPN
type Ivory 300gf MSLPN
Retention Force 100gf 300gf 500gf 1,000gf
±5° White 100gf MSOPN
0.5
Ø 6.5 0.5 FSMH
Positioner Analog Ø 3.5
※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the positioner abutment with fixture.
36 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 37
2.9
2.0
G/H 2.0 G/H 2.0
BPF3 MGT4520D
BAB352018 MKP4520D
FX4510SW FX4510SW
Female Socket
Diameter Retention Force Art. No. Ø 4.05 Ø 4.85
Ø 4.05 300~500gf BPF 3 2.9 3.3
※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the mini ball abutment with fixture.
38 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 39
Diameter Ø 4.5
1.5
G/H 2.0
MGT4515
MKP4520
FX4510SW
Magnetic Assay
SuperLine Surgical Full Kit UXNF
Application Diameter H Art. No.
Kit Includes
Ø 4.5 1.5 MGT 45 15 Ø 4.5 Ø 4.5 Ø 5.5 Ø 5.5
MKP 45
Ø 4.5 2.0 MGT 45 20 First Guide Drill Second Guide Drill Final Drill Hand-piece Adapter
1.5 2.0 1.5 2.0
XLD2229 XLD2235 XLD2629 XLD2635 XFD3435 XFD3835 XFD4335 XFD4835 XFD5831 XFA27H XFA32H
(Stopper) (Stopper)
Implant Keeper Diameter
Parallel Pin Countersink Ratchet Adapter
Diameter G/H Art. No.
1.0 MKP 45 10
2.0 MKP 45 20 1.0 2.0 3.0 4.0 5.0 6.0
3.0 MKP 45 30
Ø 4.5
4.0 MKP 45 40
XPP162220 T XCS3629SW XCS4029SW XCS4529SW XCS5029SW XCS6029SW XCS7029SW XFA26W XFA32W
5.0 MKP 45 50
6.0 MKP 45 60 MF Path Pin Final Drill(s) Hex Drill
Driver Extension
1.0 MKP 55 10
2.0 MKP 55 20 1.0 2.0 3.0 4.0 5.0
3.0 MKP 55 30 6.0
Ø 5.5
4.0 MKP 55 40 XMFPA2
XFD3429 XFD3829 XFD4329 XFD4829
5.0 MKP 55 50 XHD26T XDE
6.0 MKP 55 60
※Note: It is recommended to keep the torque level at 25~30 N·cm to tighten the magnetic abutment with fixture.
40 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 41
MF TOOL
H/P
XLD2231
Ratchet
XFD3431 XFD3831 XFD4331 XFD4831 XFD5831
XLD2207 XLD2607 XFC3607 XFC4007 XFC4507 XFC5007
Second Guide Drill Countersink Ratchet
Parallel Pin
XRCA1
5.5 7
Ø 2.2 Ø 1.7
Ø 2.2 Ø 1.7
8 10 12 14 16
26
First Guide Drill Ø 2.2 Ø 1.7
Ø 2.2 Ø 1.7
Kit Includes 41
5.5 7
Ø 2.6 Ø 2.35
Ø 2.6 Ø 2.35
8 10 12 14 16
26
Second Guide Drill Ø 2.6 Ø 2.35
Ø 2.6 Ø 2.35
XLD2235 XLD2635 XLDST06 XLDST08 XLDST10 XLDST12 XLDST14 Diameter L Art. No.
29
26 XLD 26 07 Ø 2.6 Ø 2.35
Final Drill Stopper 29 XLD 26 29
Stopper - Final Drill / 34, 38 31
34 38
31 XLD 26 31 Ø 2.6 Ø 2.35
Ø 2.6
33 XLD 26 33 33
41
XFD3435 XFD3835 XFDST06 XFDST08 XFDST10 XFDST12 XFDST14
0.7 8 10 12 14
0.7 8 10 12
0.7 8 10 12 14 16
29
Final Drill
Ø 2.9 Ø 2.5
Diameter L Art. No.
Ø 3.35 Ø 2.85
0.7 8 10 12 14
Ø 2.9 XFD 34 41
Final Drill Ø 3.35 XFD 38 41 Ø 3.85 Ø 3.3
Ø 2.9 Ø 2.5 41
Diameter L Art. No. Ø 3.85 XFD 43 41
Ø 4.4 Ø 3.8
Ø 2.9 XFD 34 31
Ø 3.35 Ø 2.85 Ø 4.4 XFD 48 41
41
Ø 3.35 XFD 38 31 Ø 3.85 Ø 3.3
Ø 3.85 31 XFD 43 31
Ø 4.4 Ø 3.8 0.5 8 10 12 14
Ø 4.4 XFD 48 31
Ø 5.4 XFD 58 31 Harvest Drill l Stopper
Ø 5.4 Ø 4.35 Ø 2.85
Diameter L Art. No.
31
Ø 3.3
Ø 2.85 XFH 34 35
Ø 3.3 XFH 38 35 Ø 3.85
35
Ø 3.85 XFH 43 35
Ø 4.4
Ø 4.4 XFH 48 35
0.7 8 10 12 14 16
35
Final Drill
Diameter L Art. No. Ø 2.9 Ø 2.5
0.5 6 7.5
Ø 3.6 Ø 2.85
Ø 2.9 XFD 34 33 Ø 3.35 Ø 2.85 Final Drill l For Short Drill
Ø 3.35 XFD 38 33 Diameter L Art. No. Ø 4.0 Ø 3.3
33 Ø 3.85 Ø 3.3
Ø 3.85 XFD 43 33
Ø 3.6 XFC 36 07 Ø 4.5 Ø 3.85
Ø 4.4 XFD 48 33 Ø 4.4 Ø 3.8
Ø 4.0 XFC 40 07
33
Ø 4.5 XFC 45 07 Ø 5.0 Ø 4.4
27
Ø 5.0 XFC 50 07
Ø 6.0 Ø 4.4
Ø 6.0 XFC 60 07
Ø 7.0 XFC 70 07
Ø 7.0 Ø 5.4
27
※Note: Drill speed 1,000rpm, 30~45 N·cm with irrigation ※Note: Drill speed 1,000rpm, 30~45 N·cm with irrigation
46 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 47
0.7 67
Stopper l For first guide drill, second guide drill
Countersink Diameter Drilling Depth L Art. No.
Diameter L Art. No. Ø 3.6
14 4.6 XLDST 14
Ø 3.6 29 XCS 36 29 SW Ø 4.0 12 6.6 XLDST 12
4.6
Ø 4.0 29 XCS 40 29 SW 10 8.6 XLDST 10 6.6 8.6 10.6 12.6 14.6
Ø 4.5
Ø 4.5 29 XCS 45 29 SW Ø 4.45 08 10.6 XLDST 08 16.6
Ø 7.0
14 4.6 XFDST 14
67
12 6.6 XFDST 12
Condensing Drill 10 8.6 XFDST 10
4.6 6.6 8.6 10.6 12.6 14.6
Diameter L Art. No. Ø 3.6
Ø 5.14 08 10.6 XFDST 08 16.6
14 4.6 XFDST 14 L
31
12 6.6 XFDST 12 L
4.6
10 8.6 XFDST 10 L 6.6 8.6 10.6 12.6
Round Bur Ø 5.14 08 10.6 XFDST 08 L
14.6 16.6
※Note: 1. Countersink Drill & Round Bur speed 1,000rpm, 30~45 N·cm with irrigation
2. Condensing Drill speed 20~60rpm, 30~45 N·cm with irrigation
48 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 49
24
26
26
30
29
32
Angled Hex Driver
Path Pin
26
Diameter L Art. No. Ø 1.6
Drill Extension
Slot Driver
Diameter L Art. No. Ø 3.0
0.6
Type L Art. No.
Ø 3.0 26 XDE 26
17
17 SDA 17 R
Ratchet
25 SDA 25 R 0.6
Driver Ø 12.0
25 Type Diameter Art. No.
6
Manual Ø 12.0 XHDHT
50 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 51
XFDST08
Hand-piece 20 XMAA 1 20
Ratchet 21 XMA 21 W
21
Ratchet 21 IPST 21 W
21
XNTW
XRT332035 XRT372035 XED331035D XRT064025 XRT084025 XST083025 XFDST 02 XFDST 04 XFDST 06 XFDST 08
XDGL XSE1L
XSE3L
Tissue Punch
Diameter L Art. No.
Ø 4.0
Ø 4.0 27 XTS 40
27
XSE4L
52 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 53
XRT083025
DASK Drill
Sinus Elevation Instrument
XSE1L
Stopper
XSE3L
Osteotome
Osteotome compresses the bone laterally, providing denser bony interface
DASK Drill rather than removing valuable bone from the surgical site.
0 2 4 6 8 10 12
DASK Drill #1 XRT 33 20 35
Crestal Ø 3.7
DASK Drill #2 XRT 37 20 35
Approach
DASK Drill #3 XED 33 10 35 D
0 1 2 4 6 8 10 12
Ø 3.3 Ø 1.6
XOF 20 A1 XOF 20 B1
Ø 8.0
XOF 34 A1 XOF 34 B1
XOF 38 A1 XOF 38 B1
Ø 8.0 Ø 6.6
XOF 43 A1 XOF 43 B1
0 1.5 3 XOF 48 A1 XOF 48 B1
08 10.6 XFDST 08
Osteotome l Final drill type l Scale 0.4 :1 Type A Type B
06 12.6 XFDST 06 10.6 12.6 14.6
Ø 5.14 16.6
Type ØA ØB Art. No. ØA ØB ØA ØB
04 14.6 XFDST 04
02 16.6 XFDST 02 Ø 1.7 Ø 2.8 XOF 20 A1
XOF 20 A1 XOF 20 B1
Ø 2.3 Ø 2.8 XOF 34 A1
Ø 2.7 Ø 3.2 XOF 38 A1
Type A
Ø 2.8 Ø 3.8 XOF 43 A1
(Convex)
Ø 3.0 Ø 4.3 XOF 48 A1 XOF 34 A1 XOF 34 B1
TN Brush
Ø 1.7 Ø 2.8 XOF 20 B1
Ø 2.3 Ø 2.8 XOF 34 B1
XOF 38 A1 XOF 38 B1
Ø 2.7 Ø 3.2 XOF 38 B1
TN Brush Type B
33
Ø 2.8 Ø 3.8 XOF 43 B1
(Concave)
Diameter Art. No. 7 9
Ø 3.0 Ø 4.3 XOF 48 B1
2
Ø0.8 TN-0.8
Ø 0.8 XOF 43 A1 XOF 43 B1
Ø1.0 TN-1.0
Ø 1.0
Ø1.3 TN-1.3
XOF 48 A1 XOF 48 B1
Ø 1.3
56 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 57
Trephine Bur
0 2 4 6 8 10
• Excellent fine cutting
• Strong engagement when attaching the trephine to cortical bone
• Cut-outs facilitates ease of harvest retrieval 14
• 5 scale marks on the Trephine drill from 2mm to 10mm
• Easy harvesting Adapter For screw abutment
37
Type Art. No. 20
Hand-piece XMAA1
Trephine Kit Torque Wrench XMA 21W
21
XIT
Kit Includes
Ø 9.0 Ø 8.0
GST 85
Ø 10.0 Ø 9.0
COD
58 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 59
Ø 3.2
2.80
Ø 0.55
2.80 GMT3225
Pin case | Pin 10ea included
Membrane Pin
XIP
L Art. No. with insertion tool
125.0 GMNT
Hex Driver
Type L Art. No.
S/T 15 XHD 15 15
25
L/T 30 XHD 30 T 30
Membrane Screws
Unit: mm, Scale 1 : 2 Adapter
Type L Art. No.
XNTW
Screw case | Screw 10ea included
60 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 61
Hex Driver
Hex L Art. No.
13 XHD 13 13 15
21
15 XHD 15 28
1.28
21 XHD 21
Hex 1.28
28 XHD 28
XPK
Reamer Guide
Application Diameter Art. No. Ø 4.5
For Combi & Dual Abutment
Diameter G/H Art. No. Ø 4.5 CRG 45 L
Combi / Dual Ø 5.5
Ø 5.5 CRG 55 L
1.5 PDAB 45 15 Abutment
Ø 6.5 CRG 65 L
2.5 PDAB 45 25 4.5
5.5 Ø 6.5
3.5
2.5
Ø 4.5 3.5 PDAB 45 35 1.5
1.5 2.5 3.5 4.5 5.5
4.5 PDAB 45 45
Application Type Art. No. Bridge
5.5 PDAB 45 55
Screw Bridge SRG BL
1.5 PDAB 55 15
Abutment Single SRG SL Single
2.5 PDAB 55 25 3.5 4.5
5.5
2.5
1.5 5.5
Ø 5.5 3.5 PDAB 55 35 1.5 2.5 3.5 4.5
4.5 PDAB 55 45
5.5 PDAB 55 55
1.5 PDAB 65 15
Reamer Handle Scale 0.5 : 1
2.5 PDAB 65 25
5.5
Ø 6.5 3.5 PDAB 65 35 1.5
2.5
3.5 4.5
CRH
3.5 4.5 5.5
1.5 2.5
4.5 PDAB 65 45
5.5 PDAB 65 55
PGSSK PGSCK
XIH
Screw Remover
Single Standard (5ea)
L Art. No.
25 T Art. No.
25 XRFS 2 S
22
33 XRFS 2
33 2.5 XSG 34 35 S
8 ° Guide XRSG 8
Cantilever Multi-Ready (5ea)
11° XRFRTF
45
8° XRFRTO 8
25
2.5 T
Abutment Hex Remover
L Art. No. 7
* Apply tooth mediodistal average width
20 XRHR 20 20
25 XRHR 25
25
GREK
GSEK
Ridge Spreader
Crestal Drill Ø2.5
Diameter L Art No. Ø1.3
Ø3.5
Ø2.3
Lateral Drill
Ø6.0
32
Diameter L Art No.
28
Ø6.0 28 GRT 06 50 28
Ø6.0 40 GRT 06 50 40
Harvest Drill
Ø6.0
Diameter L Art No. Ø3.0
5 3
40 Ø3.0 29 GHD 30 29 29
GSE 1L
Ø8.0 25 GDS 80 25
25
GSE 2L
Bone Chisel
GSE 3L 5
Art No. GBC 18 45 13 t1.8
7
9
11
13
130
GSE 4L
66 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 67
GIGK XGSFK
Spacer
Width Art No.
5.0 GSP 05
7.0 GSP 07
Ø5.0 Ø7.0 Ø9.0 Ø11.0
9.0 GSP 09
11.0 GSP 11
12.0 10.0
Multi Guide
Prosthetic Procedure 1 91
Abutment Level - Dual Abutment 92
Abutment Level - Combi Abutment 95
Proshtetic Procedure 2 97
Fixture Level - [Pick-up Type] _Dual Abutment 98
Fixture Level - [Transfer Type]_Dual Abutment 101
Fixture Level - [Transfer Type]_Milling Abutment 104
Fixture Level - [Pick-up Type]_Angled Abutment 106
Fixture Level - Direct-Casting Abutment 108
Fixture Level - Metal-Casting Abutment 109
Fixture Level - [Pick up Type]_Temporary Abutment 110
Surgical Drill Sequence I During Fixture Insertion, 70N·cm Torque at 50rpm is Recommended
· Countersink drill is used in cases with dense cortical bone.
· If the bone density is D1~D2, it is recommended to countersink after final drill.
· The actual diameter of the Countersink drill is 0.1mm larger than the fixture platform.
Drilling Sequence Guide (Final Drill)
XLD2235
XLD2635
XFD3435
XFD3835
XFD4335
XFD4835
Final Drill
XFD5831
Countersink
First Second
Guide Drill Guide Drill
3.6 4.0 4.5 5.0 3.6 4.0 4.5 5.0 6.0 7.0 7.0
14mm
12mm
10mm
8mm
Platform Ø 3.6
Platform Ø 4.5
Platform Ø 5.0
Depth Indication
Platform Ø 6.0 · Use the depth gauge after first drill / First guide drill to check depth of drilling.
· Place the depth gauge against the wall of the osteotomy.
Platform Ø 7.0
72 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 73
Condensing Drill
First Second
Guide Drill Guide Drill
3.6 4.0 4.5 5.0 3.6 4.0 4.5 5.0 6.0 7.0 7.0
Platform Ø3.6
Platform Ø4.0
Platform Ø4.5
Platform Ø5.0
Platform Ø6.0
Platform Ø7.0
74 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 75
Platform: Ø3.6 / Body: Ø3.6 (1000rpm / 30~45N·cm) Platform: Ø4.9 / Body: Ø5.0 (1000rpm / 30~45N·cm)
First Second Final drill Countersink First Second Final drill Final drill Final drill Final drill Countersink
guide drill guide drill Ø3.6 Ø3.6 guide drill guide drill Ø3.6 Ø4.0 Ø4.5 Ø5.0 Ø5.0
FX 3610 SW FX 5010 SW
Ø3.6 0.5mm Ø4.9 0.5mm
10mm 10mm
Ø3.6 Ø5.0
Platform: Ø4.0 / Body: Ø4.0 (1000rpm / 30~45N·cm) Platform: Ø6.0 / Body: Ø5.0 (1000rpm / 30~45N·cm)
First Second Final drill Final drill Countersink First Second Final drill Final drill Final drill Final drill Countersink
guide drill guide drill Ø3.6 Ø4.0 Ø4.0 guide drill guide drill Ø3.6 Ø4.0 Ø4.5 Ø5.0 Ø6.0
FX4010 SW FX 6010 SW
0.5mm Ø6.0 0.5mm
Ø4.0
10mm 10mm
Ø4.0 Ø5.0
Platform: Ø4.4 / Body: Ø4.5 (1000rpm / 30~45N·cm) Platform: Ø7.0 / Body: Ø7.0 (1000rpm / 30~45N·cm)
First Second Final drill Final drill Final drill Countersink First Second Final drill Final drill Final drill Final drill Countersink Final drill Countersink
guide drill guide drill Ø3.6 Ø4.0 Ø4.5 Ø4.5 guide drill guide drill Ø3.6 Ø4.0 Ø4.5 Ø5.0 Ø6.0 Ø7.0 Ø7.0
FX 45010 SW FX 7010 SW
Ø4.4
0.5mm Ø7.0 0.5mm
10mm 10mm
Ø4.5
Ø6.0
76 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 77
Cover Screw
Healing Abutment
Caution_ When opening the fixture pack,
hold the fixture container upward
and engage the adapter into the
fixture.
Warnings
Dental Implant surgery and restoration involve complex dental procedures. Appropriate and adequate training in proper
technique is strongly recommended prior to use.
By hand-piece By ratchet • Improper medical examination and/or treatment plan can result in implant failure and/or loss of supportive bone.
20rpm / 35 N·cm
• Improper initial stability and/or excessive occlusal forces during healing period may lead to osseointergration failure.
• Excessive insertion torque may lead to mechanical failure or implant biologic failure due to bone compression and necrosis.
• When forces or loads are greater than its design, implant or abutment fracture could happen. Therefore clinicians should
Directions Using the Hand-piece / Ratchet Adapter make careful decisions with regards to clinical treatment planning to minimize the risk of fracture. Appropriate implant
quantity, occlusal interface and a nightguard are essential. Potential excessive loading conditions may include the following:
01 Inadequate number of implants are placed.
02 Implant width and/or length are inappropriate for a treatment site.
03 Prosthesis which has excessive cantilever length due to inadequate biomechanical design
04 C
ontinuous occlusal force are generated by incomplete connection between implant and abutment and/or abutment
screw loosening.
05 D
irect Casting Abutment angles are greater than 30° from the vertical axis of the implant.
Direct Abutments are not for angulation.
Connection
06 Occlusal interferences causing excessive lateral forces
07 Patient parafunctions such as bruxism
08 Inadequate dental laboratory casting procedures
09 Improper prosthesis fit
10 Trauma from patient habits or accidents
SuperLine Hand-piece Ratchet The Hand-piece Adapter/Ratchet Adapter must be connected
11 Excessive marginal bone loss caused by inadequate bone width and/or advanced periimplantitis
Adapter Adapter firmly together with the internal hex inside the fixture
78 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 79
Cleaning
1 Rinse instruments immediately after use under running tap water (<40°C) for a minimum of one (1) minute to remove all
PROSTHESIS MANUAL
debris including extraneous body fluids, bone debris and tissue.
2 S oak all instruments immediately after rinsing in an enzymatic cleaning solution* for 10 to 20 minutes
(Do not soak overnight).
* Follow manufacturer’s instructions and observe recommended cleaning solution concentrations (enzymatic
detergent with a pH level between 7-10 and temperature not to exceed 40°C). Do not use incompatible cleaning
solutions to clean instruments.
3 F or internal irrigation drills, use a 1mL syringe and a 25 gauge needle to clean the drill irrigation hole with a minimum of
0.2 mL of the prepared cleaning solution. Repeat this step two (2) more times for a total of three (3) rinses.
4 Scrub with a soft brush for a minimum of 1 (one) minute to remove any debris inside the drill irrigation hole.
5 R
inse the instruments under running tap water (<40°C) for a minimum of 1 minute. Use a 1mL syringe and a 25 gauge
needle with a minimum of 0.2 mL of tap water to forcefully flush inside the drill irrigation hole. Repeat flushing of drill
irrigation hole two (2) more times for a total of three (3) flushings.
6 P
lace instruments into an ultrasonic cleaner with neutral detergent**. Keep instruments inside the ultrasonic bath for
15 minutes using a frequency of 25-50 kHz. Ensure multiple instruments placed within the bath remain separated.
** Follow manufacturer’s instructions and observe recommended neutral detergent solution concentrations (neutral
detergent with a pH level between 7-10 and temperature not to exceed 40°C). Do not use incompatible neutral
detergent solutions to clean instruments.
7 R
inse instruments thoroughly with running tap water (<40°C) for a minimum of 1 (one) minute until all traces of neutral
detergent solution are removed. Rinse inside drill irrigation hole using a 1mL syringe and a 25 gauge needle with a
minimum of 0.2 mL of tap water. Repeat rinsing drill irrigation hole two (2) more times for a total of three (3) rinses.
8 G
ently wipe instruments with a soft lint-free cloth or place the instruments in a drying cabinet (60°C for less than 10
hours) until fully dry. Blow residual water from drill irrigation hole using a 1mL syringe and a 25 gauge needle.
Visually inspect instruments in a well-lit area to ensure they are clean, dry and free of residue.
9 Clean instrument trays with a germicidal cleaner prior to returning instruments into Kit.
10 Always check for damage or corrosion after rinsing and drying.
Sterilization
Dentium recommends either the Pre-vacuum or Gravity autoclave methods for sterilization under the conditions described
below. However, autoclave performance can affect the efficacy of this process. Healthcare facilities should validate their
sterilization processes employing the actual equipment and operators that routinely sterilize instruments.
All autoclaves/sterilizers should be regularly validated, maintained and checked in accordance with EN 285/EN 13060, EN
ISO 17665, ANSI AAMI ST79 to ensure compliance with these and related standards. Make sure packaging is suitable for
steam sterilization.
One-Piece Two-Pieces
(15°)
Types of Abutment (Abutments are available in various diameters & gingival heights)
Hex Non-hex Hex Non-hex Hex Non-hex
· Dual Abutment Cylinder Metal-Casting Abutment Temporary Abutment
Abutment level
· Combi Abutment
Abutment Level Fixture Level
· Dual Abutment
· Dual Milling Abutment · Straight abutments are Dual and Combi Abutment.
· Angled Abutment (15°/25°) · Depending on the insertion angle and position of the fixture, the Angled or Direct / Metal - Casting Abutment may be
Fixture level used.
· Direct-Casting Abutment
· Metal-Casting Abutment · The Screw Abutment can be used when prosthesis retrieval is anticipated.
· Temporary Abutment (Plastic & Titanium)
· Screw Abutment
Screw retained (Abutment level)
· Angled Screw Abutment (15°/ 30°)
· Positioner Attachment
· Ball Attachment For denture use
· Magnetic Attachment
82 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 83
Prosthetic part
Transmucosal part
· It is possible to take an impression at both fixture level and abutment level. Combi Abutment
(A Dual Abutment may be interchanged with a Combi Abutment)
· For abutment level impressions, the same prosthetic procedures apply to both Dual and Combi Abutments.
· For fixture level impressions, the abutment selection takes place on the master model. · The Combi Abutment is used when the implant position is optimal.
· For fixture level impressions, a precise positioning jig for abutment may be required. · If the abutment selection is made in the mouth, gauge the thickness of mucosa with the depth gauge to measure the
· Either hex or non-hex abutments may be used, according to operator's preference. gingival height thus allowing the appropriate abutment height.
· The Impression is taken with the snap cap.
* I f a cement retained restoration requires retrieval, cutting a hole in the occlusal surface would allow access to the screw · When using the Combi Abutment, it remains in the mouth after the impression is taken.
to permit removal. (Do not remove or change its position)
· Tighten abutment screw to 25 - 35 N·cm. (retighten again before seating final prosthesis).
* If the Combi Abutment is too long it can be adjusted 1.5mm to the bottom of the laser mark on the vertical stack of the
Hex / Non-hex abutment. The Combi Abutment has a short analog for the 1.5mm adjustment.
* A resin jig can be made to record the reduction if reduced more the 1.5mm.
Hex Non-hex
Diameter G/H Vertical Angle A° Ø6.5 1.5mm, 2.5mm, 3.5mm, 4.5mm, 5.5mm 7°
15° 25°
Angled Abutment
Custom Abutment
· Impression is taken at fixture level. · The Angled Abutment is recommended when the restoration path of insertion is unfavorable in either anterior or
· When using a non-hex abutment a precise seating jig should be used. posterior sites.
· Retention force can be increased through milling process.
Milling Abutment
· Impression is taken at fixture level.
· When using a non-hex abutment a precise seating jig should be used.
· Either hex or non-hex abutments may be used, according to operators preference.
* I f a cement retained restoration requires retrieval, cutting a hole in the occlusal surface would allow access to the screw
for removal.
Ø4.0 1.0mm
Ø4.5 1.5mm
Ø5.5 1.5mm, 2.5mm Hex / Non-hex
Ø6.5 1.5mm, 2.5mm, 3.5mm
Ø7.5 2.5mm, 3.5mm
86 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 87
Ø4.5
Plastic Temporary Ø5.5 2.0mm Hex / Non-hex
Ø6.5
Metal-Casting Abutment
· Equivalent results for a fraction of the price
· Our highly affordable metal alloy replaces expensive gold to alleviate financial burden to all.
* Diagram above indicates the minimum height required for SuperLine prosthetic abutment.
Dual Abutment
· Preparation of the abutment top is possible as follows.
Analog Analog
Gingival Height Preparable Amount
Long Short
1.5mm 2.0 Ø 4.5 / Ø 5.5 / Ø 6.5 Ø 4.5 / Ø 5.5 / Ø 6.5
2.5mm 3.0
3.5mm 4.0
4.5mm 5.0
5.5mm 6.0 Burn-out Cylinder
Modification
Direct-Casting Abutment & Metal-Casting Abutment
· The Screw Abutment cannot be modified, however the Casting Abutment can be modified for interarch distance, taking
reduction into consideration of the height of the retaining screw.
Cemented Restoration
92 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 93
Gold
Crown
Porcelain
Crown
Chairside LabSide
Remove the Healing Abutment after Dual Abutment (Hex / Non-hex) Select the Dual Abutment by diameter Insertion of Combi Abutment analog Make sure analog seats securely into the Soft tissue model
formation of soft tissue. and gingival height. into impression impression cap. (line up the flat side of
analog to the flat side of the cap)
Retighten after 15 minutes Seat the plastic cap over the abutment. Injection of impression material Fabrication of master cast Seat burn-out cylinder securely Consider distance of opposing teeth,
Tighten it to 25~30N·cm. into analog. Modify burn-out cylinder to its proper
heigh if needed.
Impression taking Cap comes off into the impression Fabrication of provisional restoration Fabrication of burn-out cylinder and Completion of wax-up Fabrication of metal framework
or insertion of comfort cap plastic bar in preparation for wax-up
94 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 95
Chairside
Trimming of the extended margin by Metal framework and reamer Reamer is used to eliminate “Lip” caused
using the rubber wheel by ‘snap-on’ mechanism.
Second stage surgery Following the 2nd stage surgery, soft tissue Choose abutment with gingival height
(uncovering) is healed around the Healing Abutment. then tighten it to 25~30N·cm.
Healing Abutment should be selected Re tighten after 15 minutes.
according to the size of abutment.
SCRP: Once an access hole has been created, it can be converted to a SCRP (Screw & Image of combi Impression coping and Snap-on the plastic impression coping Impression taking
Cemented Retained Prosthesis). abutment assembly with the same sized diameter abutment Injection of impression material
Final prosthesis Access hole is made when burn-out Extended margin around the metal Impression taking Inner-surface of impression Extended margin around the metal
framework due to ‘snap-on’ mechanism
cylinder is used to do the wax-up. framework due to ‘snap-on’ mechanism
Chairside
Trim extended margin by rubber wheel Metal framework and reamer Eliminate the lip remnant caused by
‘snap-on’ mechanism by reamer.
Seating of Lab analog Confirm analog is secured in snap cap Soft tissue model
Fabrication of master cast Placement of burn-out cylinder Consider the distance of opposing teeth,
modify burn-out cylinders to its proper
height.
96 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 97
Connect the plastic bar in the middle of Wax-up Completed framework Hex Non-hex
the trimmed burn-out cylinders to help Hex Non-hex
support the resin pattern. Wax pattern
may have shrinkage.
Impression Coping Pick-up Impression Coping Transfer
Open tray technique (Complicated case) Closed tray technique (Simple case)
Ø 4.0 / Ø 4.5 / Ø 5.5 / Ø 6.5 Ø 4.0 / Ø 4.5 / Ø 5.5 / Ø 6.5
Trimming the extended margin Metal framework and reamer Removal of lip remnant with reamer
with a rubber wheel caused by ‘snap-on’ mechanism Analog
Ø 4.5
*If the combi analog is trimmed due to limited inter-occlusal space in the lab, make a Insertion of final prosthesis and
reduction jig. Then a slight modify of the abutment in the oral cavity may be necessary to occlusal adjustment
the height of the jig.
Modification Modification
Fixture Level [Pick-up Type]_Dual Abutment Fixture Level [Pick-up Type]_Dual Abutment
[Multiple Units] [Multiple Units]
Porcelain
Crown
LabSide LabSide
Open tray impression (pick-up) Connect lab analog with Soft tissue model Fabrication of master cast
impression coping.
Apply adhesive on open tray. Injecting the impression material Connect a proper abutment After surveying abutment milling is Fabrication of positioning jig
(Individual tray) possible if necessary.
Impression taking Remove the screw before removing the Inner surface of impression Fabrication of the cap with pattern resin Wax-up Metal framework
impression tray.
100 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 101
Fixture Level [Pick-up Type]_Dual Abutment Fixture Level [Transfer Type]_Dual Abutment
[Multiple Units] [Multiple Units]
Final prosthesis Use positioning jig to transfer the Insertion of the final prosthesis and
abutment in model to oral cavity then occlusal adjustment
tighten it to 25~30N·cm.
Retighten after 15 minutes.
* In the process of seating the prosthesis, the prosthesis can be rebounded by gingival tissue.
In this case it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
Formation of access hole with long trans- Wax-up Metal framework Second stage surgery (Uncovering) Soft tissue formed around Transfer type impression coping
fer coping screw Healing Abutment
SCRP- Chairside
Seating the impression coping which has Impression of fixture level Injection of impression material
the same diameter as (No x-ray necessary for confirmation)
Healing Abutment
Final prosthesis Use positioning jig to transfer the Insertion of final prosthesis and
abutment in model to oral cavity then adjustment of occlusion
tighten it to 25~30N·cm.
Retighten after 15 minutes.
* In the process of seating the prosthesis, the prosthesis can be rebounded by gingival tissue.
In this case it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
Fixture Level [Transfer Type]_Dual Abutment Fixture Level [Transfer Type]_Dual Abutment
[Multiple Units] [Multiple Units]
Clinical Procedure
Gold
Crown
Porcelain
Crown
Seat the cap with pattern resin Completion of wax-up Completion of metal framework
Chairside
Final prosthesis built up on the Use positioning jig to transfer the Insertion of final prosthesis,
LabSide framework with porcelain abutment in model to oral cavity then adjust occlusion place lab wax into open-
tighten it to 25~30N·cm. ing of abutment to protect
Retighten after 15 minutes. screw head then cement.
SCRP- Labside
Impression coping and analog Make sure the impression coping is fully Soft tissue model
connection. And insert impression seated into the impression
coping into the impression.
Make an access hole in the resin cap by Completed wax-up Metal framework
using the long open tray transfer screw.
SCRP- Chairside
Fabrication of master cast Soft tissue condition after the of Measuring gingival height with
impression coping depth gauge
Final prosthesis built up on the Use positioning jig to transfer the Insertion of final prosthesis and occlusal
framework with porcelain abutment in model to oral cavity then adjustment. Place wax into opening of
tighten it to 25~30N·cm. the abutment prior to sealing with
Retighten after 15 minutes. composite.
* In the process of seating the prosthesis, the prosthesis can be rebounded by gingival tissue.
Selection of Dual Abutment of proper Verify by surveying the selected abutment. Fabrication of positioning jig In this case it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
diameter and gingival height (Milling of the abutment is possible if necessary)
104 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 105
Fixture Level [Transfer Type]_Milling Abutment Fixture Level [Transfer Type]_Milling Abutment
[Single Unit] [Single Unit]
Healing Abutment Impression Coping Transfer Type Fixture Level Impression Closed Tray
Chairside
Selection of appropriate Dual Milling Abutment after milling process Fabrication of positioning jig
Abutment
Chairside
* In the process of seating the prosthesis, the prosthesis can be rebounded by gingival tissue.
In this case it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
Fixture Level [Pick-up Type]_Angled Abutment Fixture Level [Pick-up Type]_Angled Abutment
[Single Unit] [Single Unit]
Impression coping with analog Soft tissue formation and fabrication Unscrew then separate impression from
connections of master model the model.
Chairside
Master cast Select an Angled Abutment. Modification of Angled Abutment &
fabrication of positioning jig
Pick-up type impression coping Placement of pick-up impression Injecting impression material
Laboratory Procedure
Final prosthesis Insertion of the Angled Insertion of final prosthesis and
Abutment using positioning jig occlusal adjustment
LabSide LabSide
Placement of Direct-Casting Abutment Completed custom abutment Fabrication of positioning jig Placement of Metal-Casting Abutment Completed custom abutment Fabrication of positioning jig
Fabrication of pattern resin cap Wax-up Metal framework Fabrication of pattern resin cap Wax-up Metal framework
Chairside Chairside
Final prosthesis Insertion of custom abutment using Insertion of final prosthesis and Final prosthesis Insertion of custom abutment using Insertion of final prosthesis and
positioning jig occlusal adjustment positioning jig occlusal adjustment
110 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 111
Screw Abutment
Angled Screw
Screw
Abutment
Abutment
Hex / Non-hex
Ø 4.5 / Ø 5.5
20°
Ø 4.5 / Ø 5.5
Analog
Ø 4.5 / Ø 5.5
Ti-Retaining
Screw
Screw-Retained Restoration
112 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 113
Abutment Level [Transfer Type]_Screw Abutment Abutment Level [Transfer Type]_Screw Abutment
[Multiple Units] [Multiple Units]
LabSide LabSide
Select and seat an appropriate Screw Tighten it to 25~30N·cm. Retighten after Connecting impression coping with Position impression coping and analog Soft tissue model
Abutment with delivery holder. 15 minutes with Screw Abutment adaptor. Screw Abutment analog assembly in the exact location of the
impression
Screw Abutment transfer copings Placement of impression copings Injecting impression material Fabrication of master cast Removal of impression coping Connect the Screw Abutment cylinder
(abutment level) then tighten it with ti-retaining screw.
Impression taking Inner-surface of impression Placement of comfort cap on Consider the distance with opposing Connect the plastic bar in the middle of Wax-up
Screw Abutment teeth, then trim cylinder to its trimmed burn-out cylinders to help
appropriate height. support the wax pattern. Wax pattern
may have shrinkage.
114 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 115
Metal framework Removal of lip remnant in the interior of Completion of metal framework
metal framework by using reamer
In case of the following: In order to unscrew, form access hole on Unscrew, then remove the prosthesis
screw loosing Prosthesis repair the occlusal surface using bur. from the oral cavity.
Both cemented prosthesis and Finish the repair then seat it inside the Tighten the prosthesis with
abutment are removed. oral cavity. 25~30N·cm by a screw driver.
* It is recommended that the abutment screw is
retightened after 15 minutes.
Fill the access hole with cotton. Fill the access hole with resin. Final prosthesis
116 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 117
Remove the screw completely with screw Apply cement to the prosthesis. Place it back into the patient’s mouth. Positioner Mini Ball Magnetic
driver and remove prosthesis Abutment Abutment Implant Keeper
from the patient’s mouth. Ø 3.5 Ø 3.5 Dome type / Flat type
Ø 4.5 / Ø 5.5
Abutment Level
Impression
After the cement setting, unscrew and Finish the repair and seat it inside Tighten the prosthesis with
remove the excessive cement. the patient’s mouth. 25~30N·cm with a screw driver. Positioner Mini Ball
Impression Impression
Adding to the Interproximal Contact Surface due to Prosthesis Loosening Coping Coping
Ø 4.5 Ø 3.5
Contact adding with resin on the Insert the prosthesis in the oral cavity
prepared under space. and screw it in. Afterwards, perform light
curing, then polish the contact area. Positioner Mini Ball
* It is recommended that the abutment screw is Socket Female Socket / Magnetic Assay
retightened after 15 minutes.
Metal / Plastic O-ring Dome type / Flat type
Ø 4.05 / Ø 4.85 Ø 4.5 / Ø 5.5
Position the prosthesis in the mouth and Positioner Attachment Mini Ball and Socket Attachment Magnetic Attachment
tighten the screw with 25~30N·cm, then for Overdenture for Overdenture for Overdenture
fill up the access hole.
118 SuperLine Product / Manual Catalog SuperLine Product / Manual Catalog 119
Positioner Positioner
Chairside Case 1
Chairside
Connect the Positioner Abutment onto Affix the impression coping on the Take Impression for the production of
the fixture. Positioner Abutment. individual tray.
Secure spaces for the female sockets. Place the “block out spacer” on the Connect the metal socket onto the Posi-
Positioner Abutment in the patient’s tioner Abutment.
mouth.
Produce the individual tray for After connecting the Positioner Take the final impression with the pre-
denture impression. Abutment and the impression coping pared individual tray.
together, apply the impression material.
Apply a small amount of resin into the Position the denture in the mouth and Remove the white plastic socket (100gf)
space created for the metal socket. wait until the resin is completely set. using the positioner tool and assemble
with the regular plastic socket giving
the desired retention force (300, 500 or
1000gf).
After the impression material is set, Image of the set final impression
discard the individual tray. (with impression coping)
Labside
Secure spaces for the female sockets. Place the “block out spacer” on the Connect the metal socket onto the Posi-
Positioner Abutment in the patient’s tioner Abutment.
mouth.
Positioner Analog Insert the Positioner Analog into the Create the master model.
embedded impression coping.
Secure spaces for the female sockets. Connect the female sockets to the Apply small amount of the resin
Mini Ball Abutments in the intra-oral. into the secured area.
Create holes for the placement Place the “block out spacer” on the Connect the metal socket onto the Posi-
of the metal sockets. Positioner Abutment in the intraoral. tioner Abutment.
Position the denture in the oral cavity and Female sockets are placed After polishing, the overdenture
wait until the resin is completely set. in the denture. is completed.
Create holes for placement Connect the female sockets to the Examine the interference between
of female sockets. Mini Ball Abutments in the intra-oral. inner surface of the holes and the
female sockets.
Apply additional resin around the Apply resin around the metal socket. After polishing, the overdenture is
metal socket where there is a shortage completed.
of resin.
Apply the resin into the holes and Female sockets are placed Apply resin around the female sockets.
wait until it is completely set. in the denture.
After Healing Abutment removal Connect implant keeper with fixture and Implant keepers connected with Create holes for the placement of Examine the interference between inner Position the denture in the mouth and
tighten it with 25~30N·cm. the fixtures the magnets. surface of the holes and apply small amount of resin into the hole.
the magnets.
Position the magnetic assay on the Secure spaces for the magnetic assays. Examine the interference between inner
implant keeper. divot of the denture and the magnets. Wait until the resin is completely set. After setting, remove denture from Add the resin around the magnets.
the mouth.
Case 1 Chairside
Apply some of resin around the After the resin is completely set,
magnetic assays. remove excess. After polishing, the
overdenture is completed.